1
-
-
0033798463
-
The haemolytic, icteric and lipemic sample recommendations regarding their recognition and prevention of clinically relevant interferences
-
Guder W.G., da Fonseca-Wollheim F., Heil W., Schmitt Y.M., Töpfer G., Wisser H., et al. The haemolytic, icteric and lipemic sample recommendations regarding their recognition and prevention of clinically relevant interferences. J Lab Med 2000, 24:357-364.
-
(2000)
J Lab Med
, vol.24
, pp. 357-364
-
-
Guder, W.G.1
da Fonseca-Wollheim, F.2
Heil, W.3
Schmitt, Y.M.4
Töpfer, G.5
Wisser, H.6
-
2
-
-
0021431651
-
Direct spectrophotometry of serum hemoglobin: an Allen correction compared with a three-wavelength polychromatic analysis
-
Noe D.A., Weedn V., Bell W.R. Direct spectrophotometry of serum hemoglobin: an Allen correction compared with a three-wavelength polychromatic analysis. Clin Chem 1984, 30:627-630.
-
(1984)
Clin Chem
, vol.30
, pp. 627-630
-
-
Noe, D.A.1
Weedn, V.2
Bell, W.R.3
-
3
-
-
0026604380
-
Methods for measuring plasma hemoglobin in micromolar concentration compared
-
Fairbanks V.F., Ziesmer S.C., O'Brien P.C. Methods for measuring plasma hemoglobin in micromolar concentration compared. Clin Chem 1992, 38:132-140.
-
(1992)
Clin Chem
, vol.38
, pp. 132-140
-
-
Fairbanks, V.F.1
Ziesmer, S.C.2
O'Brien, P.C.3
-
4
-
-
0002427925
-
A method for determination of hemoglobin in plasma by near-ultraviolet spectrophotometry
-
Harboe M. A method for determination of hemoglobin in plasma by near-ultraviolet spectrophotometry. Scand J Clin Lab Invest 1959, 11:66-70.
-
(1959)
Scand J Clin Lab Invest
, vol.11
, pp. 66-70
-
-
Harboe, M.1
-
5
-
-
70349484951
-
Multicenter evaluation of the hemolysis index in automated clinical chemistry systems
-
Lippi G., Luca Salvagno G., Blanckaert N., Giavarina D., Green S., Kitchen S., et al. Multicenter evaluation of the hemolysis index in automated clinical chemistry systems. Clin Chem Lab Med 2009, 47:934-939.
-
(2009)
Clin Chem Lab Med
, vol.47
, pp. 934-939
-
-
Lippi, G.1
Luca Salvagno, G.2
Blanckaert, N.3
Giavarina, D.4
Green, S.5
Kitchen, S.6
-
6
-
-
70349492209
-
Hemolysis index: quality indicator or criterion for sample rejection?
-
Plebani M., Lippi G. Hemolysis index: quality indicator or criterion for sample rejection?. Clin Chem Lab Med 2009, 47:899-902.
-
(2009)
Clin Chem Lab Med
, vol.47
, pp. 899-902
-
-
Plebani, M.1
Lippi, G.2
-
7
-
-
11144334591
-
Automated processing of serum indices used for interference detection by the laboratory information system
-
Vermeer H.J., Thomassen E., de Jonge N. Automated processing of serum indices used for interference detection by the laboratory information system. Clin Chem 2005, 51:244-247.
-
(2005)
Clin Chem
, vol.51
, pp. 244-247
-
-
Vermeer, H.J.1
Thomassen, E.2
de Jonge, N.3
-
8
-
-
0029801957
-
Lipid interference in the determination of the concentration of haemoglobin in plasma using the ACA SX analyzer
-
Hofmann M., Kaufhold S., Henkel E., Oellerich M. Lipid interference in the determination of the concentration of haemoglobin in plasma using the ACA SX analyzer. Eur J Clin Chem Clin Biochem 1996, 34:811-816.
-
(1996)
Eur J Clin Chem Clin Biochem
, vol.34
, pp. 811-816
-
-
Hofmann, M.1
Kaufhold, S.2
Henkel, E.3
Oellerich, M.4
-
9
-
-
0031474786
-
Plasma hemoglobin measurement techniques for the in vitro evaluation of blood damage caused by medical devices
-
Malinauskas R.A. Plasma hemoglobin measurement techniques for the in vitro evaluation of blood damage caused by medical devices. Artif Organs 1997, 21:1255-1267.
-
(1997)
Artif Organs
, vol.21
, pp. 1255-1267
-
-
Malinauskas, R.A.1
-
10
-
-
0021045350
-
A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in Clinical Chemistry, Part I
-
Passing H., Bablok W. A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in Clinical Chemistry, Part I. J Clin Chem Clin Biochem 1983, 21:709-720.
-
(1983)
J Clin Chem Clin Biochem
, vol.21
, pp. 709-720
-
-
Passing, H.1
Bablok, W.2
-
11
-
-
10344253270
-
A simple spectrophotometric method for the quantification of residual haemoglobin in platelet concentrates
-
Cookson P., Sutherland J., Cardigan R. A simple spectrophotometric method for the quantification of residual haemoglobin in platelet concentrates. Vox Sang 2004, 87:264-271.
-
(2004)
Vox Sang
, vol.87
, pp. 264-271
-
-
Cookson, P.1
Sutherland, J.2
Cardigan, R.3
-
12
-
-
34548331332
-
Measurements of free hemoglobin and hemolysis index: EDTA- or lithium-heparinate plasma?
-
Unger J., Filippi G., Patsch W. Measurements of free hemoglobin and hemolysis index: EDTA- or lithium-heparinate plasma?. Clin Chem 2007, 53:1717-1718.
-
(2007)
Clin Chem
, vol.53
, pp. 1717-1718
-
-
Unger, J.1
Filippi, G.2
Patsch, W.3
|