-
1
-
-
84875874468
-
Incidence of and risk factors for superior facet violation in minimally invasive versus open pedicle screw placement during transforaminal lumbar interbody fusion: a comparative analysis
-
Lau, D., Terman, S.W., Patel, R., La Marca, F., Park, P., Incidence of and risk factors for superior facet violation in minimally invasive versus open pedicle screw placement during transforaminal lumbar interbody fusion: a comparative analysis. J Neurosurg Spine 18 (2013), 356–361.
-
(2013)
J Neurosurg Spine
, vol.18
, pp. 356-361
-
-
Lau, D.1
Terman, S.W.2
Patel, R.3
La Marca, F.4
Park, P.5
-
2
-
-
46149126169
-
Pedicle screw insertion: computed tomography versus fluoroscopic image guidance
-
Fu, T.S., Wong, C.B., Tsai, T.T., Liang, Y.C., Chen, L.H., Chen, W.J., Pedicle screw insertion: computed tomography versus fluoroscopic image guidance. Int Orthop 32 (2008), 517–521.
-
(2008)
Int Orthop
, vol.32
, pp. 517-521
-
-
Fu, T.S.1
Wong, C.B.2
Tsai, T.T.3
Liang, Y.C.4
Chen, L.H.5
Chen, W.J.6
-
3
-
-
80052588107
-
Comparison study between C-arm X-ray and 3D-CT in guiding thoracolumbar pedicle screw fixation
-
Huang, Y., Kong, R., Fang, S.Y., Yu, D.W., Li, S.M., Zhang, B., et al. Comparison study between C-arm X-ray and 3D-CT in guiding thoracolumbar pedicle screw fixation. Shandong Med J 49 (2009), 5–7.
-
(2009)
Shandong Med J
, vol.49
, pp. 5-7
-
-
Huang, Y.1
Kong, R.2
Fang, S.Y.3
Yu, D.W.4
Li, S.M.5
Zhang, B.6
-
4
-
-
33846886691
-
Clinical accuracy of cervicothoracic pedicle screw placement: a comparison of the “open” lamino-foraminotomy and computer-assisted techniques
-
Lee, G.Y., Massicotte, E.M., Rampersaud, Y.R., Clinical accuracy of cervicothoracic pedicle screw placement: a comparison of the “open” lamino-foraminotomy and computer-assisted techniques. J Spinal Disord Techn 20 (2007), 25–32.
-
(2007)
J Spinal Disord Techn
, vol.20
, pp. 25-32
-
-
Lee, G.Y.1
Massicotte, E.M.2
Rampersaud, Y.R.3
-
5
-
-
84872394906
-
Accuracy of lower cervical pedicle screw placement with assistance of distinct navigation systems: a human cadaveric study
-
Tian, W., Liu, Y., Zheng, S., Lv, Y., Accuracy of lower cervical pedicle screw placement with assistance of distinct navigation systems: a human cadaveric study. Eur Spine J 22 (2013), 148–155.
-
(2013)
Eur Spine J
, vol.22
, pp. 148-155
-
-
Tian, W.1
Liu, Y.2
Zheng, S.3
Lv, Y.4
-
6
-
-
84902486394
-
Accuracy of pedicle screw placement in scoliosis surgery: a comparison between conventional computed tomography-based and O-arm-based navigation techniques
-
Kotani, T., Akazawa, T., Sakuma, T., Koyama, K., Nemoto, T., Nawata, K., et al. Accuracy of pedicle screw placement in scoliosis surgery: a comparison between conventional computed tomography-based and O-arm-based navigation techniques. Asian Spine J 8 (2014), 331–338.
-
(2014)
Asian Spine J
, vol.8
, pp. 331-338
-
-
Kotani, T.1
Akazawa, T.2
Sakuma, T.3
Koyama, K.4
Nemoto, T.5
Nawata, K.6
-
7
-
-
78649284471
-
Comparison of the clinical accuracy of cervical (C2-C7) pedicle screw insertion assisted by fluoroscopy, computed tomography-based navigation, and intraoperative three-dimensional C-arm navigation
-
Liu, Y.J., Tian, W., Liu, B., Li, Q., Hu, L., Li, Z.Y., et al. Comparison of the clinical accuracy of cervical (C2-C7) pedicle screw insertion assisted by fluoroscopy, computed tomography-based navigation, and intraoperative three-dimensional C-arm navigation. Chinese Med J 123 (2010), 2995–2998.
-
(2010)
Chinese Med J
, vol.123
, pp. 2995-2998
-
-
Liu, Y.J.1
Tian, W.2
Liu, B.3
Li, Q.4
Hu, L.5
Li, Z.Y.6
-
8
-
-
61549092238
-
Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort
-
Nottmeier, E.W., Seemer, W., Young, P.M., Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort. J Neurosurg Spine 10 (2009), 33–39.
-
(2009)
J Neurosurg Spine
, vol.10
, pp. 33-39
-
-
Nottmeier, E.W.1
Seemer, W.2
Young, P.M.3
-
9
-
-
3042805099
-
Navigation using fluoro-CT technology: concept and clinical experience in a new method for intraoperative navigation
-
Gruetzner, P., Wentzensen, A., Waelti, H., Hebecker, A., Nolte, L.P., Wentzensen, A., Navigation using fluoro-CT technology: concept and clinical experience in a new method for intraoperative navigation. Eur J Trauma 30 (2004), 161–170.
-
(2004)
Eur J Trauma
, vol.30
, pp. 161-170
-
-
Gruetzner, P.1
Wentzensen, A.2
Waelti, H.3
Hebecker, A.4
Nolte, L.P.5
Wentzensen, A.6
-
10
-
-
80052564997
-
Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies
-
Tian, N.F., Huang, Q.S., Zhou, P., Zhou, Y., Wu, R.K., Lou, Y., et al. Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies. Eur Spine J 20 (2011), 846–859.
-
(2011)
Eur Spine J
, vol.20
, pp. 846-859
-
-
Tian, N.F.1
Huang, Q.S.2
Zhou, P.3
Zhou, Y.4
Wu, R.K.5
Lou, Y.6
-
11
-
-
79951676298
-
A comparison of CT-based navigation techniques for minimally invasive lumbar pedicle screw placement
-
Wood, M., Mannion, R., A comparison of CT-based navigation techniques for minimally invasive lumbar pedicle screw placement. J Spinal Disord Techn 24 (2011), E1–E5.
-
(2011)
J Spinal Disord Techn
, vol.24
, pp. E1-E5
-
-
Wood, M.1
Mannion, R.2
-
12
-
-
35348900058
-
A comparison of two techniques in image-guided thoracic pedicle screw placement: a retrospective study of 37 patients and 277 pedicle screws
-
Lekovic, G.P., Potts, E.A., Karahalios, D.G., Hall, G., A comparison of two techniques in image-guided thoracic pedicle screw placement: a retrospective study of 37 patients and 277 pedicle screws. J Neurosurg Spine 7 (2007), 393–398.
-
(2007)
J Neurosurg Spine
, vol.7
, pp. 393-398
-
-
Lekovic, G.P.1
Potts, E.A.2
Karahalios, D.G.3
Hall, G.4
-
13
-
-
84893337997
-
The accuracy of pedicle screw placement using intraoperative image guidance systems
-
Mason, A., Paulsen, R., Babuska, J.M., Rajpal, S., Burneikiene, S., Nelson, E.L., et al. The accuracy of pedicle screw placement using intraoperative image guidance systems. J Neurosurg Spine 20 (2014), 196–203.
-
(2014)
J Neurosurg Spine
, vol.20
, pp. 196-203
-
-
Mason, A.1
Paulsen, R.2
Babuska, J.M.3
Rajpal, S.4
Burneikiene, S.5
Nelson, E.L.6
-
14
-
-
42449121048
-
Navigated pedicle screw placement: experimental comparison between CT- and 3D fluoroscopy-based techniques
-
Geerling, J., Gosling, T., Gosling, A., Ortega, G., Kendoff, D., Citak, M., et al. Navigated pedicle screw placement: experimental comparison between CT- and 3D fluoroscopy-based techniques. Comput Aided Surg 13 (2008), 157–166.
-
(2008)
Comput Aided Surg
, vol.13
, pp. 157-166
-
-
Geerling, J.1
Gosling, T.2
Gosling, A.3
Ortega, G.4
Kendoff, D.5
Citak, M.6
-
15
-
-
0033562611
-
Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery
-
Slomczykowski, M., Roberto, M., Schneeberger, P., Ozdoba, C., Vock, P., Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery. Spine 24 (1999), 975–982.
-
(1999)
Spine
, vol.24
, pp. 975-982
-
-
Slomczykowski, M.1
Roberto, M.2
Schneeberger, P.3
Ozdoba, C.4
Vock, P.5
-
16
-
-
34848838276
-
Current concepts and applications of computer navigation in orthopedic trauma surgery
-
Kendo, D., Citak, M., Hüfner, T., Chaudhary, S., Krettek, C., Current concepts and applications of computer navigation in orthopedic trauma surgery. Cent Eur J Med 2 (2007), 392–403.
-
(2007)
Cent Eur J Med
, vol.2
, pp. 392-403
-
-
Kendo, D.1
Citak, M.2
Hüfner, T.3
Chaudhary, S.4
Krettek, C.5
-
17
-
-
79955769676
-
Minimally invasive pedicle screw fixation utilizing O-arm fluoroscopy with computer-assisted navigation: feasibility, technique, and preliminary results
-
Park, P., Foley, K.T., Cowan, J.A., Marca, F.L., Minimally invasive pedicle screw fixation utilizing O-arm fluoroscopy with computer-assisted navigation: feasibility, technique, and preliminary results. Surg Neurol Int, 1, 2010, 44.
-
(2010)
Surg Neurol Int
, vol.1
, pp. 44
-
-
Park, P.1
Foley, K.T.2
Cowan, J.A.3
Marca, F.L.4
-
18
-
-
33748079472
-
Does computer-assisted spine surgery reduce intraoperative radiation doses?
-
Gebhard, F.T., Kraus, M.D., Schneider, E., Liener, U.C., Kinzl, L., Arand, M., Does computer-assisted spine surgery reduce intraoperative radiation doses?. Spine 31 (2006), 2024–2027.
-
(2006)
Spine
, vol.31
, pp. 2024-2027
-
-
Gebhard, F.T.1
Kraus, M.D.2
Schneider, E.3
Liener, U.C.4
Kinzl, L.5
Arand, M.6
-
19
-
-
67649226406
-
Intraoperative 3D imaging: value and consequences in 248 cases
-
Kendoff, D., Citak, M., Gardner, M.J., Stübig, T., Krettek, C., Hüfner, T., Intraoperative 3D imaging: value and consequences in 248 cases. J Trauma 66 (2009), 232–238.
-
(2009)
J Trauma
, vol.66
, pp. 232-238
-
-
Kendoff, D.1
Citak, M.2
Gardner, M.J.3
Stübig, T.4
Krettek, C.5
Hüfner, T.6
|