Volumn 20, Issue 6, 2011, Pages 846-859

Pedicle screw insertion accuracy with different assisted methods: A systematic review and meta-analysis of comparative studies

Author keywords

Accuracy; Computer tomography; Fluoroscopy; Navigated spine surgery; Pedicle screw

Indexed keywords

ACCURACY; COMPUTER ASSISTED TOMOGRAPHY; FLUOROSCOPY; HUMAN; META ANALYSIS; PEDICLE SCREW; PEDICLE SCREW INSERTION; PRIORITY JOURNAL; REVIEW; SCOLIOSIS; SPINE SURGERY; SYSTEMATIC REVIEW; THREE DIMENSION FLUOROSCOPY; TWO DIMENSION FLUOROSCOPY; BONE SCREW; COMPUTER ASSISTED SURGERY; INTERNAL FIXATOR; METHODOLOGY; RADIOGRAPHY; SPINE; SPINE FUSION;

EID: 80052564997     PISSN: 09406719     EISSN: 14320932     Source Type: Journal    
DOI: 10.1007/s00586-010-1577-5     Document Type: Review
Times cited : (285)

References (61)
  • 1
    • 0014442736 scopus 로고
    • Reduction of severe spondylolisthesis in children
    • Harrington PR, Tullos HS (1969) Reduction of severe spondylolisthesis in children. South Med J 62:1-7
    • (1969) South Med J , vol.62 , pp. 1-7
    • Harrington, P.R.1    Tullos, H.S.2
  • 2
    • 67349149712 scopus 로고    scopus 로고
    • Lateral radiological evaluation of transarticular screw placement in the lower cervical spine
    • Xu R, Zhao L, Chai B et al (2009) Lateral radiological evaluation of transarticular screw placement in the lower cervical spine. Eur Spine J 18:392-397
    • (2009) Eur Spine J , vol.18 , pp. 392-397
    • Xu, R.1    Zhao, L.2    Chai, B.3
  • 3
    • 77951110057 scopus 로고    scopus 로고
    • Lamina-guided lateral mass screw placement in the sub-axial cervical spine
    • Bayley E, Zia Z, Kerslake R et al (2010) Lamina-guided lateral mass screw placement in the sub-axial cervical spine. Eur Spine J 19:660-664
    • (2010) Eur Spine J , vol.19 , pp. 660-664
    • Bayley, E.1    Zia, Z.2    Kerslake, R.3
  • 4
    • 0142087694 scopus 로고    scopus 로고
    • An extrapedicular approach to the placement of screws in the thoracic spine: An anatomic and radiographic assessment
    • DOI 10.1097/01.BRS.0000085361.32600.63
    • Husted DS, Yue JJ, Fairchild TA et al (2003) An extrapedicular approach to the placement of screws in the thoracic spine: an anatomic and radiographic assessment. Spine 28:2324-2330 (Pubitemid 37271327)
    • (2003) Spine , vol.28 , Issue.20 , pp. 2324-2330
    • Husted, D.S.1    Yue, J.J.2    Fairchild, T.A.3    Haims, A.H.4
  • 5
    • 77955012894 scopus 로고    scopus 로고
    • Morphometric comparisons between the pedicle and the pedicle rib unit in the immature Chinese thoracic spine: A computed tomographic assessment
    • Tian NF, Xu HZ, Wang XY et al (2010) Morphometric comparisons between the pedicle and the pedicle rib unit in the immature Chinese thoracic spine: a computed tomographic assessment. Spine 35:1514-1519
    • (2010) Spine , vol.35 , pp. 1514-1519
    • Tian, N.F.1    Xu, H.Z.2    Wang, X.Y.3
  • 6
    • 50649120840 scopus 로고    scopus 로고
    • The value of bilateral ipsilateral and contralateral motor evoked potential monitoring in scoliosis surgery
    • Lo YL, Dan YF, Teo A et al (2008) The value of bilateral ipsilateral and contralateral motor evoked potential monitoring in scoliosis surgery. Eur Spine J 17:S236-S238
    • (2008) Eur Spine J , vol.17
    • Lo, Y.L.1    Dan, Y.F.2    Teo, A.3
  • 7
    • 35648975300 scopus 로고    scopus 로고
    • The diagnostic value of multimodal intraoperative monitoring (MIOM) during spine surgery: A prospective study of 1,017 patients
    • DOI 10.1007/s00586-007-0418-7, Multimodal Intraoperative Monitoring in Spine Surgery
    • Sutter M, Eggspuehler A, Grob D et al (2007) The diagnostic value of multimodal intraoperative monitoring (MIOM) during spine surgery: a prospective study of 1,017 patients. Eur Spine J 16:S162-S170 (Pubitemid 350029512)
    • (2007) European Spine Journal , vol.16 , Issue.SUPPL. 2
    • Sutter, M.1    Eggspuehler, A.2    Grob, D.3    Jeszenszky, D.4    Benini, A.5    Porchet, F.6    Mueller, A.7    Dvorak, J.8
  • 8
    • 33846683025 scopus 로고    scopus 로고
    • Pedicle screw placement accuracy: A meta-analysis
    • DOI 10.1097/01.brs.0000254048.79024.8b, PII 0000763220070201000022
    • Kosmopoulos V, Schizas C (2007) Pedicle screw placement accuracy: a meta-analysis. Spine 32:E111-E120 (Pubitemid 46197463)
    • (2007) Spine , vol.32 , Issue.3
    • Kosmopoulos, V.1    Schizas, C.2
  • 9
    • 68349104323 scopus 로고    scopus 로고
    • Image-guided pedicle screw insertion accuracy: A meta-analysis
    • Tian NF, Xu HZ (2009) Image-guided pedicle screw insertion accuracy: a meta-analysis. Int Orthop 33:895-903
    • (2009) Int Orthop , vol.33 , pp. 895-903
    • Tian, N.F.1    Xu, H.Z.2
  • 10
    • 68549121139 scopus 로고    scopus 로고
    • Usefulness of a navigation system in surgery for scoliosis: Segmental pedicle screw fixation in the treatment
    • Nakanishi K, Tanaka M, Misawa H et al (2009) Usefulness of a navigation system in surgery for scoliosis: segmental pedicle screw fixation in the treatment. ArchOrthop Trauma Surg 129:1211-1218
    • (2009) ArchOrthop Trauma Surg , vol.129 , pp. 1211-1218
    • Nakanishi, K.1    Tanaka, M.2    Misawa, H.3
  • 11
    • 33748420054 scopus 로고    scopus 로고
    • Qualitative and quantitative accuracy of CAOS in a standardized in vitro spine model
    • DOI 10.1097/01.blo.0000218731.36967.e8, PII 0000308620060900000021
    • Arand M, Schempf M, Fleiter T et al (2006) Qualitative and quantitative accuracy of CAOS in a standardized in vitro spine model. Clin Orthop Relat Res 450:118-128 (Pubitemid 44342125)
    • (2006) Clinical Orthopaedics and Related Research , Issue.450 , pp. 118-128
    • Arand, M.1    Schempf, M.2    Fleiter, T.3    Kinzl, L.4    Gebhard, F.5
  • 12
    • 46149126169 scopus 로고    scopus 로고
    • Pedicle screw insertion: Computed tomography versus fluoroscopic image guidance
    • Fu TS, Wong CB, Tsai TT et al (2008) Pedicle screw insertion: computed tomography versus fluoroscopic image guidance. Int Orthop 32:517-521
    • (2008) Int Orthop , vol.32 , pp. 517-521
    • Fu, T.S.1    Wong, C.B.2    Tsai, T.T.3
  • 13
    • 33846886691 scopus 로고    scopus 로고
    • Clinical accuracy of cervicothoracic pedicle screw placement: A comparison of the "open" lamino-foraminotomy and computer-assisted techniques
    • DOI 10.1097/01.bsd.0000211239.21835.ad, PII 0002472020070200000005
    • Lee GY, Massicotte EM, Rampersaud YR (2007) Clinical accuracy of cervicothoracic pedicle screw placement: a comparison of the "open" lamino-foraminotomy and computer-assisted techniques. J Spinal Disord Tech 20:25-32 (Pubitemid 46220321)
    • (2007) Journal of Spinal Disorders and Techniques , vol.20 , Issue.1 , pp. 25-32
    • Lee, G.Y.F.1    Massicotte, E.M.2    Raja Rampersaud, Y.3
  • 14
    • 35348900058 scopus 로고    scopus 로고
    • A comparison of two techniques in image-guided thoracic pedicle screw placement: A retrospective study of 37 patients and 277 pedicle screws
    • DOI 10.3171/spi.2007.7.4.393
    • Lekovic GP, Potts EA, Karahalios DG et al (2007) A comparison of two techniques in image-guided thoracic pedicle screw placement: a retrospective study of 37 patients and 277 pedicle screws. J Neurosurg Spine 7:393-398 (Pubitemid 47584614)
    • (2007) Journal of Neurosurgery: Spine , vol.7 , Issue.4 , pp. 393-398
    • Lekovic, G.P.1    Potts, E.A.2    Karahalios, D.G.3    Hall, G.4
  • 16
    • 61549092238 scopus 로고    scopus 로고
    • Placement of thoracolumbar pedicle screws using three-dimensional image guidance: Experience in a large patient cohort
    • Nottmeier EW, Seemer W, Young PM (2009) Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort. J Neurosurg Spine 10:33-39
    • (2009) J Neurosurg Spine , vol.10 , pp. 33-39
    • Nottmeier, E.W.1    Seemer, W.2    Young, P.M.3
  • 18
    • 33846239956 scopus 로고    scopus 로고
    • Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries
    • DOI 10.1097/01.brs.0000252094.64857.ab, PII 0000763220070115000030
    • Rajasekaran S, Vidyadhara S, Ramesh P et al (2007) Randomized clinical study to compare the accuracy of navigated and nonnavigated thoracic pedicle screws in deformity correction surgeries. Spine 32:E56-E64 (Pubitemid 46105794)
    • (2007) Spine , vol.32 , Issue.2
    • Rajasekaran, S.1    Vidyadhara, S.2    Ramesh, P.3    Shetty, A.P.4
  • 19
    • 0034061781 scopus 로고    scopus 로고
    • Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    • DOI 10.1097/00007632-200003010-00012
    • Amiot LP, Lang K, Putzier M et al (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 25:606-614 (Pubitemid 30158220)
    • (2000) Spine , vol.25 , Issue.5 , pp. 606-614
    • Amiot, L.-P.1    Lang, K.2    Putzier, M.3    Zippel, H.4    Labelle, H.5
  • 21
    • 34250782220 scopus 로고    scopus 로고
    • Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: Comparison between conventional fluoroscopic and computer-assisted technique
    • DOI 10.1097/BRS.0b013e318068661e, PII 0000763220070615000014
    • Kotani Y, Abumi K, Ito M et al (2007) Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique. Spine 32:1543-1550 (Pubitemid 46956151)
    • (2007) Spine , vol.32 , Issue.14 , pp. 1543-1550
    • Kotani, Y.1    Abumi, K.2    Ito, M.3    Takahata, M.4    Sudo, H.5    Ohshima, S.6    Minami, A.7
  • 22
    • 0030926450 scopus 로고    scopus 로고
    • Improved accuracy of pedicle screw insertion with computer-assisted surgery: A prospective clinical trial of 30 patients
    • DOI 10.1097/00007632-199706010-00018
    • Laine T, Schlenzka D, Mäkitalo K et al (1997) Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients. Spine 22:1254-1258 (Pubitemid 27259842)
    • (1997) Spine , vol.22 , Issue.11 , pp. 1254-1258
    • Laine, T.1    Schlenzka, D.2    Makitalo, K.3    Tallroth, K.4    Nolte, L.-P.5    Visarius, H.6
  • 23
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomised controlled clinical study in 100 consecutive patients
    • Laine T, Lund T, Ylikoski M et al (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9:235-240
    • (2000) Eur Spine J , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikoski, M.3
  • 25
    • 27144527301 scopus 로고    scopus 로고
    • Cervical pedicle screws: Conventional versus computer-assisted placement of cannulated screws
    • DOI 10.1097/01.brs.0000182275.31425.cd
    • Richter M, Cakir B, Schmidt R (2005) Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine 30:2280-2287 (Pubitemid 41504897)
    • (2005) Spine , vol.30 , Issue.20 , pp. 2280-2287
    • Richter, M.1    Cakir, B.2    Schmidt, R.3
  • 27
    • 0034747109 scopus 로고    scopus 로고
    • Precision analysis of navigation-assisted implanted thoracic and lumbar pedicled screws. A prospective clinical study
    • Arand M, Hartwig E, Hebold D et al (2001) Precision analysis of navigation-assisted implanted thoracic and lumbar pedicled screws. A prospective clinical study. Unfallchirurg 104:1076-1081
    • (2001) Unfallchirurg , vol.104 , pp. 1076-1081
    • Arand, M.1    Hartwig, E.2    Hebold, D.3
  • 28
    • 1542288140 scopus 로고    scopus 로고
    • Genauigkeit der CT-basierten Navigation vion Pedikelschrauben an der Brustwirbelsäule im Vergleich zur konventionellen Technik
    • DOI 10.1007/s00113-003-0720-8
    • Schnake KJ, König B, Berth U et al (2004) Accuracy of CT-based navigation of pedicle screws in the thoracic spine compared with conventional technique. Unfallchirurg 107:104-112 (Pubitemid 38314162)
    • (2004) Unfallchirurg , vol.107 , Issue.2 , pp. 104-112
    • Schnake, K.J.1    Konig, B.2    Berth, U.3    Schroeder, R.J.4    Kandziora, F.5    Stockle, U.6    Raschke, M.7    Haas, N.P.8
  • 29
    • 27744580272 scopus 로고    scopus 로고
    • Prospective screw misplacement analysis after conventional and navigated pedicle screw implantation
    • Seller K, Wild A, Urselmann L et al (2005) Prospective screw misplacement analysis after conventional and navigated pedicle screw implantation. Biomed Tech (Berl) 50:287-292
    • (2005) Biomed Tech (Berl) , vol.50 , pp. 287-292
    • Seller, K.1    Wild, A.2    Urselmann, L.3
  • 30
    • 80052588107 scopus 로고    scopus 로고
    • Comparison study between C-arm X-ray and 3D CT in guiding thoracolumbar pedicle screw fixation
    • Huang Y, Kong R, Fang SY et al (2009) Comparison study between C-arm X-ray and 3D CT in guiding thoracolumbar pedicle screw fixation. Shandong Med J (Chin) 49:5-7
    • (2009) Shandong Med J (Chin) , vol.49 , pp. 5-7
    • Huang, Y.1    Kong, R.2    Fang, S.Y.3
  • 32
    • 39049192490 scopus 로고    scopus 로고
    • Accuracy of CT-based navigation of pedicle screws implantation in the cervical spine compared with X-ray fluoroscopy technique
    • Liu YJ, Tian W, Liu B et al (2005) Accuracy of CT-based navigation of pedicle screws implantation in the cervical spine compared with X-ray fluoroscopy technique. Chin J Surg (Chin) 43:1328-1330
    • (2005) Chin J Surg (Chin) , vol.43 , pp. 1328-1330
    • Liu, Y.J.1    Tian, W.2    Liu, B.3
  • 33
    • 54949139385 scopus 로고    scopus 로고
    • Application of orthopaedic guidance for pedicle screw fixation of spine
    • Yang YH, Ye H, Zheng J et al (2005) Application of orthopaedic guidance for pedicle screw fixation of spine. Orthop J Chin (Chin) 13:75-76
    • (2005) Orthop J Chin (Chin) , vol.13 , pp. 75-76
    • Yang, Y.H.1    Ye, H.2    Zheng, J.3
  • 34
    • 54949118534 scopus 로고    scopus 로고
    • Preliminary application of spinal navigation with the intra-operative 3D-imaging modality in pedicle screw fixation
    • Xu L, Yu X, Zheng DB et al (2004) Preliminary application of spinal navigation with the intra-operative 3D-imaging modality in pedicle screw fixation. Orthop J Chin (Chin) 12:1895-1897
    • (2004) Orthop J Chin (Chin) , vol.12 , pp. 1895-1897
    • Xu, L.1    Yu, X.2    Zheng, D.B.3
  • 35
    • 84956524420 scopus 로고    scopus 로고
    • Clinical applications of computer assisted navigation technique in scoliosis surgery
    • Yang LL, Chen HJ, Chen DY et al (2007) Clinical applications of computer assisted navigation technique in scoliosis surgery. Orthop J Chin (Chin) 15:1773-1776
    • (2007) Orthop J Chin (Chin) , vol.15 , pp. 1773-1776
    • Yang, L.L.1    Chen, H.J.2    Chen, D.Y.3
  • 36
    • 80052561875 scopus 로고    scopus 로고
    • Pedicle screw placement under the guidance of computer-assisted navigation system
    • Zhang DS, Yuan JT, Zheng J et al (2008) Pedicle screw placement under the guidance of computer-assisted navigation system. Chin J Min Inv Surg (Chin) 8:544-546
    • (2008) Chin J Min Inv Surg (Chin) , vol.8 , pp. 544-546
    • Zhang, D.S.1    Yuan, J.T.2    Zheng, J.3
  • 37
    • 66649120105 scopus 로고    scopus 로고
    • Computer-assisted navigation technique in the spinal pedicle screw internal fixation
    • Li SG, Sheng L, Zhao H et al (2009) Computer-assisted navigation technique in the spinal pedicle screw internal fixation. J Clin Rehabil Tissue Eng Res (Chin) 13:3365-3369
    • (2009) J Clin Rehabil Tissue Eng Res (Chin) , vol.13 , pp. 3365-3369
    • Li, S.G.1    Sheng, L.2    Zhao, H.3
  • 38
    • 80052570228 scopus 로고    scopus 로고
    • Experience of pedicle screw fixation in the cervical spine using navigation system
    • Tian W, Liu B, Li Q et al (2003) Experience of pedicle screw fixation in the cervical spine using navigation system. J Spinal Surg (Chin) 1:15-18
    • (2003) J Spinal Surg (Chin) , vol.1 , pp. 15-18
    • Tian, W.1    Liu, B.2    Li, Q.3
  • 39
    • 0037111853 scopus 로고    scopus 로고
    • Image-guided spine surgery: A cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models
    • DOI 10.1097/00007632-200211150-00015
    • Austin MS, Vaccaro AR, Brislin B et al (2002) Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models. Spine 27:2503-2508 (Pubitemid 35346161)
    • (2002) Spine , vol.27 , Issue.22 , pp. 2503-2508
    • Austin, M.S.1    Vaccaro, A.R.2    Brislin, B.3    Nachwalter, R.4    Hilibrand, A.S.5    Albert, T.J.6
  • 40
    • 0034491195 scopus 로고    scopus 로고
    • Computer-assisted fluoroscopic targeting system for pedicle screw insertion
    • Choi WW, Green BA, Levi AD (2000) Computer-assisted fluoroscopic targeting system for pedicle screw insertion. Neurosurgery 47:872-878 (Pubitemid 32103663)
    • (2000) Neurosurgery , vol.47 , Issue.4 , pp. 872-878
    • Choi, W.W.1    Green, B.A.2    Levi, A.D.O.3
  • 41
    • 0037442352 scopus 로고    scopus 로고
    • Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: A cadaver study
    • DOI 10.1097/00007632-200302150-00018
    • Mirza SK, Wiggins GC, Kuntz C et al (2003) Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study. Spine 28:402-413 (Pubitemid 36232625)
    • (2003) Spine , vol.28 , Issue.4 , pp. 402-413
    • Mirza, S.K.1    Wiggins, G.C.2    Kuntz IV, C.3    York, J.E.4    Bellabarba, C.5    Knonodi, M.A.6    Chapman, J.R.7    Shaffrey, C.I.8
  • 42
    • 2142643168 scopus 로고    scopus 로고
    • Electromagnetic fieldbased image-guided spine surgery part two: Results of a cadaveric study evaluating thoracic pedicle screw placement
    • Sagi HC, Manos R, Park SC et al (2003) Electromagnetic fieldbased image-guided spine surgery part two: results of a cadaveric study evaluating thoracic pedicle screw placement. Spine 28:E351-E354
    • (2003) Spine , vol.28
    • Sagi, H.C.1    Manos, R.2    Park, S.C.3
  • 43
    • 0041333802 scopus 로고    scopus 로고
    • Electromagnetic field-based image-guided spine surgery part one: Results of a cadaveric study evaluating lumbar pedicle screw placement
    • DOI 10.1097/01.BRS.0000087851.51547.00
    • Sagi HC, Manos R, Benz R et al (2003) Electromagnetic fieldbased image-guided spine surgery part one: results of a cadaveric study evaluating lumbar pedicle screw placement. Spine 28:2013-2018 (Pubitemid 37082669)
    • (2003) Spine , vol.28 , Issue.17 , pp. 2013-2018
    • Sagi, H.C.1    Manos, R.2    Benz, R.3    Ordway, N.R.4    Connolly, P.J.5
  • 44
    • 0035478265 scopus 로고    scopus 로고
    • Transpedicular screw placement: Image-guided versus lateral-view fluoroscopy: In vitro simulation
    • DOI 10.1097/00007632-200110010-00024
    • Assaker R, Reyns N, Vinchon M et al (2001) Transpedicular screw placement: image-guided versus lateral-view fluoroscopy: in vitro simulation. Spine 26:2160-2164 (Pubitemid 32929374)
    • (2001) Spine , vol.26 , Issue.19 , pp. 2160-2164
    • Assaker, R.1    Reyns, N.2    Vinchon, M.3    Demondion, X.4    Louis, E.5
  • 45
    • 33644877786 scopus 로고    scopus 로고
    • Pedicle screw placement in the thoracic spine: A comparison of image-guided and manual techniques in cadavers
    • Hart RA, Hansen BL, Shea M et al (2005) Pedicle screw placement in the thoracic spine: a comparison of image-guided and manual techniques in cadavers. Spine 30:E326-E331
    • (2005) Spine , vol.30
    • Hart, R.A.1    Hansen, B.L.2    Shea, M.3
  • 47
    • 0033925472 scopus 로고    scopus 로고
    • Placement of pedicle screws in the human cadaveric cervical spine: Comparative accuracy of three techniques
    • DOI 10.1097/00007632-200007010-00009
    • Ludwig SC, Kramer DL, Balderston RA et al (2000) Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques. Spine 25:1655-1667 (Pubitemid 30460467)
    • (2000) Spine , vol.25 , Issue.13 , pp. 1655-1667
    • Ludwig, S.C.1    Kramer, D.L.2    Balderston, R.A.3    Vaccaro, A.R.4    Foley, K.F.5    Albert, T.J.6
  • 48
    • 0034667343 scopus 로고    scopus 로고
    • Cervical pedicle screws: Comparative accuracy of two insertion techniques
    • Ludwig SC, Kowalski JM, Edwards CC et al (2000) Cervical pedicle screws: comparative accuracy of two insertion techniques. Spine 25:2675-2681
    • (2000) Spine , vol.25 , pp. 2675-2681
    • Ludwig, S.C.1    Kowalski, J.M.2    Edwards, C.C.3
  • 49
    • 66649131641 scopus 로고    scopus 로고
    • Experimental study and clinical applications of computer assisted navigation technique in spinal surgery
    • Tian W, Liu YJ, Liu B et al (2006) Experimental study and clinical applications of computer assisted navigation technique in spinal surgery. Chin J Orthop (Chin) 26:671-675
    • (2006) Chin J Orthop (Chin) , vol.26 , pp. 671-675
    • Tian, W.1    Liu, Y.J.2    Liu, B.3
  • 50
    • 80052607608 scopus 로고    scopus 로고
    • Study on pedicle screw fixation of cervical spine assisted CT-based navigation system compared with the individual cervical peddle screws placement technique
    • He XS, Yang HL, Zhu RF et al (2008) Study on pedicle screw fixation of cervical spine assisted CT-based navigation system compared with the individual cervical peddle screws placement technique. Suzhou Univ J Med Sci (Chin) 28:415-417
    • (2008) Suzhou Univ J Med Sci (Chin) , vol.28 , pp. 415-417
    • He, X.S.1    Yang, H.L.2    Zhu, R.F.3
  • 51
    • 78751490021 scopus 로고    scopus 로고
    • Application of computerassisted fluoroscopic navigation based on the C-arm X-ray in pedicle screw fixation
    • Xia Q, Yan SJ, Chen TY et al (2007) Application of computerassisted fluoroscopic navigation based on the C-arm X-ray in pedicle screw fixation. Fudan Univ J Med Sci (Chin) 34:873-876
    • (2007) Fudan Univ J Med Sci (Chin) , vol.34 , pp. 873-876
    • Xia, Q.1    Yan, S.J.2    Chen, T.Y.3
  • 52
    • 23244450640 scopus 로고    scopus 로고
    • Accuracy of computerized frameless stereotactic image-guided pedicle screw placement into previously fused lumbar spines
    • DOI 10.1097/01.brs.0000171905.38459.b7
    • Lim MR, Girardi FP, Yoon SC et al (2005) Accuracy of computerized frameless stereotactic image-guided pedicle screw placement into previously fused lumbar spines. Spine 30:1793-1798 (Pubitemid 41099495)
    • (2005) Spine , vol.30 , Issue.15 , pp. 1793-1798
    • Lim, M.R.1    Girardi, F.P.2    Yoon, S.C.3    Huang, R.C.4    Cammisa Jr., F.P.5
  • 53
    • 33846279003 scopus 로고    scopus 로고
    • Fluoroscopic computer-assisted pedicle screw placement through a mature fusion mass: An assessment of 24 consecutive cases with independent analysis of computed tomography and clinical data
    • DOI 10.1097/01.brs.0000251751.51936.3f, PII 0000763220070115000012
    • Rampersaud YR, Lee KS (2007) Fluoroscopic computer-assisted pedicle screw placement through a mature fusion mass: an assessment of 24 consecutive cases with independent analysis of computed tomography and clinical data. Spine 32:217-222 (Pubitemid 46115954)
    • (2007) Spine , vol.32 , Issue.2 , pp. 217-222
    • Rampersaud, Y.R.1    Lee, K.-S.2
  • 54
    • 67651163423 scopus 로고    scopus 로고
    • Electromagnetic navigation for percutaneous guide-wire insertion: Accuracy and efficiency compared to conventional fluoroscopic guidance
    • von Jako RA, Carrino JA, Yonemura KS et al (2009) Electromagnetic navigation for percutaneous guide-wire insertion: accuracy and efficiency compared to conventional fluoroscopic guidance. Neuroimage 47:T127-T132
    • (2009) Neuroimage , vol.47
    • Von Jako, R.A.1    Carrino, J.A.2    Yonemura, K.S.3
  • 55
    • 70349871137 scopus 로고    scopus 로고
    • Comparison of the percutaneous screw placement precision of isocentric C-arm 3-dimensional fluoroscopy-navigated pedicle screw implantation and conventional fluoroscopy method with minimally invasive surgery
    • Nakashima H, Sato K, Ando T et al (2009) Comparison of the percutaneous screw placement precision of isocentric C-arm 3-dimensional fluoroscopy- navigated pedicle screw implantation and conventional fluoroscopy method with minimally invasive surgery. J Spinal Disord Tech 22:468-472
    • (2009) J Spinal Disord Tech , vol.22 , pp. 468-472
    • Nakashima, H.1    Sato, K.2    Ando, T.3
  • 56
    • 77951143798 scopus 로고    scopus 로고
    • Functional outcome of computer-assisted spinal pedicle screw placement: A systematic review and meta-analysis of 23 studies including 5,992 pedicle screws
    • Verma R, Krishan S, Haendlmayer K et al (2010) Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws. Eur Spine J 19:370-375
    • (2010) Eur Spine J , vol.19 , pp. 370-375
    • Verma, R.1    Krishan, S.2    Haendlmayer, K.3
  • 57
    • 0037783239 scopus 로고    scopus 로고
    • Computer-assisted orthopedic surgery
    • DOI 10.1007/s10776-002-0623-6
    • Sugano N (2003) Computer-assisted orthopedic surgery. J Orthop Sci 8:442-448 (Pubitemid 36702100)
    • (2003) Journal of Orthopaedic Science , vol.8 , Issue.3 , pp. 442-448
    • Sugano, N.1
  • 59
    • 0033562611 scopus 로고    scopus 로고
    • Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery
    • Slomczykowski M, Roberto M, Schneeberger P et al (1999) Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery. Spine 24:975-982
    • (1999) Spine , vol.24 , pp. 975-982
    • Slomczykowski, M.1    Roberto, M.2    Schneeberger, P.3
  • 60
    • 33748079472 scopus 로고    scopus 로고
    • Does computer-assisted spine surgery reduce intraoperative radiation doses?
    • DOI 10.1097/01.brs.0000229250.69369.ac, PII 0000763220060801000022
    • Gebhard FT, Kraus MD, Schneider E et al (2006) Does computerassisted spine surgery reduce intraoperative radiation doses? Spine 31:2024-2027 (Pubitemid 44297785)
    • (2006) Spine , vol.31 , Issue.17 , pp. 2024-2027
    • Gebhard, F.T.1    Kraus, M.D.2    Schneider, E.3    Liener, U.C.4    Kinzl, L.5    Arand, M.6
  • 61
    • 75049084141 scopus 로고    scopus 로고
    • Image-guided spine surgery: State of the art and future directions
    • Tjardes T, Shafizadeh S, Rixen D et al (2010) Image-guided spine surgery: state of the art and future directions. Eur Spine J 19:25-45
    • (2010) Eur Spine J , vol.19 , pp. 25-45
    • Tjardes, T.1    Shafizadeh, S.2    Rixen, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.