1
-
-
0032527483
-
Use of cervicothoracic junction pedicle screws for reconstruction of complex cervical spine pathology
-
Albert TJ, Klein GR, Joffe D, et al. Use of cervicothoracic junction pedicle screws for reconstruction of complex cervical spine pathology. Spine. 1998;23:1596-1599.
-
(1998)
Spine
, vol.23
, pp. 1596-1599
-
-
Albert, T.J.1
Klein, G.R.2
Joffe, D.3
-
2
-
-
0027996259
-
Spinal disorders at the cervicothoracic junction
-
An HS, Vaccaro A, Cotler JM, et al. Spinal disorders at the cervicothoracic junction. Spine. 1994;19:2557-2564.
-
(1994)
Spine
, vol.19
, pp. 2557-2564
-
-
An, H.S.1
Vaccaro, A.2
Cotler, J.M.3
-
3
-
-
0030006266
-
Posterior instrumentation of the unstable cervicothoracic spine
-
Chapman JR, Anderson PA, Pepin C, et al. Posterior instrumentation of the unstable cervicothoracic spine. J Neurosurg. 1996;84:552-558.
-
(1996)
J Neurosurg
, vol.84
, pp. 552-558
-
-
Chapman, J.R.1
Anderson, P.A.2
Pepin, C.3
-
4
-
-
2542503391
-
Posterior cervicothoracic instrumentation in spine tumours
-
Mazel C, Hoffmann E, Antonietti P, et al. Posterior cervicothoracic instrumentation in spine tumours. Spine. 2004;29:1246-1253.
-
(2004)
Spine
, vol.29
, pp. 1246-1253
-
-
Mazel, C.1
Hoffmann, E.2
Antonietti, P.3
-
5
-
-
1442277695
-
Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine
-
Richter M, Mattes T, Cakir B. Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine. Eur Spine J. 2004;13:50-59.
-
(2004)
Eur Spine J
, vol.13
, pp. 50-59
-
-
Richter, M.1
Mattes, T.2
Cakir, B.3
-
6
-
-
0034657288
-
Internal morphology of human cervical pedicles
-
Panjabi MM, Shin EK, Chen NC, et al. Internal morphology of human cervical pedicles. Spine. 2000;25:1197-1205.
-
(2000)
Spine
, vol.25
, pp. 1197-1205
-
-
Panjabi, M.M.1
Shin, E.K.2
Chen, N.C.3
-
7
-
-
0035101506
-
Thoracic pedicle: Surgical anatomic evaluation and relations
-
Ugur HC, Attar A, Uz A, et al. Thoracic pedicle: surgical anatomic evaluation and relations. J Spinal Disord. 2001;14:39-45.
-
(2001)
J Spinal Disord
, vol.14
, pp. 39-45
-
-
Ugur, H.C.1
Attar, A.2
Uz, A.3
-
8
-
-
85130086181
-
Placement of pedicle screws in the thoracic spine. Part 1: Morphometric analysis of the thoracic vertebrae
-
Vaccaro AR, Rizzolo SJ, Allardyce TJ, et al. Placement of pedicle screws in the thoracic spine. Part 1: Morphometric analysis of the thoracic vertebrae. J Bone Joint Surg [Am]. 1995;77:1200-1206.
-
(1995)
J Bone Joint Surg [Am]
, vol.77
, pp. 1200-1206
-
-
Vaccaro, A.R.1
Rizzolo, S.J.2
Allardyce, T.J.3
-
9
-
-
0031427940
-
Pedicle screw fixation for nontraumatic lesions of the cervical spine
-
Abumi K, Kaneda K. Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine. 1997;22:1853-1863.
-
(1997)
Spine
, vol.22
, pp. 1853-1863
-
-
Abumi, K.1
Kaneda, K.2
-
10
-
-
1042289633
-
Thoracic pedicle screw insertion using a transpedicular drill guide: A preliminary study
-
Mac-Thiong J-M, Labelle H, Aubin C-E. Thoracic pedicle screw insertion using a transpedicular drill guide: a preliminary study. J Spinal Disord Tech. 2004;17:29-32.
-
(2004)
J Spinal Disord Tech
, vol.17
, pp. 29-32
-
-
Mac-Thiong, J.-M.1
Labelle, H.2
Aubin, C.-E.3
-
11
-
-
0034466242
-
Cervical pedicle screw insertion: Assessment of safety and accuracy with computer-assisted image guidance
-
Kamimura M, Ebara S, Itoh H, et al. Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord. 2000;13:218-224.
-
(2000)
J Spinal Disord
, vol.13
, pp. 218-224
-
-
Kamimura, M.1
Ebara, S.2
Itoh, H.3
-
12
-
-
0034667343
-
Cervical pedicle screws: Comparative accuracy of two insertional techniques
-
Ludwig S, Kowalski JM, Edwards CC II, et al. Cervical pedicle screws: comparative accuracy of two insertional techniques. Spine. 2000;25:2675-2681.
-
(2000)
Spine
, vol.25
, pp. 2675-2681
-
-
Ludwig, S.1
Kowalski, J.M.2
Edwards II, C.C.3
-
13
-
-
0033925472
-
Placement of pedicle screws in the human cadaveric cervical spine: Comparative accuracy of three techniques
-
Ludwig S, Kramer DL, Balderston RA, et al. Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques. Spine. 2000;25:1655-1667.
-
(2000)
Spine
, vol.25
, pp. 1655-1667
-
-
Ludwig, S.1
Kramer, D.L.2
Balderston, R.A.3
-
14
-
-
0034061781
-
Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
-
Amiot L-P, Lang K, Putzier M, et al. Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine. 2000;25:606-614.
-
(2000)
Spine
, vol.25
, pp. 606-614
-
-
Amiot, L.-P.1
Lang, K.2
Putzier, M.3
|