메뉴 건너뛰기




Volumn 17, Issue S1, 2015, Pages e86-e96

Clinical Reliability of CAD/CAM cross-arch zirconia bridges on immediately loaded implants placed with computer-assisted/template-guided surgery: A retrospective study with a follow-up between 3 and 5 years

Author keywords

CAD CAM; Complications; Cross arch fixed dental prosthesis; Dental implants; Edentulous; Zirconia

Indexed keywords

ZIRCONIUM; ZIRCONIUM OXIDE;

EID: 85028276088     PISSN: 15230899     EISSN: 17088208     Source Type: Journal    
DOI: 10.1111/cid.12132     Document Type: Article
Times cited : (75)

References (67)
  • 1
    • 0017564248 scopus 로고
    • Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
    • Brånemark PI, Hansson BO, Adell R, etal. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl 1977; 16:1-132.
    • (1977) Scand J Plast Reconstr Surg Suppl , vol.16 , pp. 1-132
    • Brånemark, P.I.1    Hansson, B.O.2    Adell, R.3
  • 2
    • 34250665803 scopus 로고    scopus 로고
    • A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: fixed dental prostheses
    • Sailer I, Pjetursson BE, Zwahlen M, Hämmerle CHF. A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: fixed dental prostheses. Clin Oral Implants Res 2007; 18(Suppl 3):86-96.
    • (2007) Clin Oral Implants Res , vol.18 , pp. 86-96
    • Sailer, I.1    Pjetursson, B.E.2    Zwahlen, M.3    Hämmerle, C.H.F.4
  • 3
    • 0036617486 scopus 로고    scopus 로고
    • Clinical considerations in case selection for all-ceramic fixed partial dentures
    • Raigrodski AJ, Saltzer AM. Clinical considerations in case selection for all-ceramic fixed partial dentures. Pract Proced Aesthet Dent 2002; 14:411-419.
    • (2002) Pract Proced Aesthet Dent , vol.14 , pp. 411-419
    • Raigrodski, A.J.1    Saltzer, A.M.2
  • 4
    • 29644436765 scopus 로고    scopus 로고
    • All-ceramic fixed partial dentures, part I: in vitro studies
    • Raigrodski AJ, Chiche GJ. All-ceramic fixed partial dentures, part I: in vitro studies. J Esthet Restor Dent 2002; 14:188-191.
    • (2002) J Esthet Restor Dent , vol.14 , pp. 188-191
    • Raigrodski, A.J.1    Chiche, G.J.2
  • 5
    • 85047596525 scopus 로고    scopus 로고
    • All-ceramic fixed partial dentures, part III: clinical studies
    • Raigrodski AJ, Chiche GJ, Swift EJ Jr. All-ceramic fixed partial dentures, part III: clinical studies. J Esthet Restor Dent 2002; 14:313-319.
    • (2002) J Esthet Restor Dent , vol.14 , pp. 313-319
    • Raigrodski, A.J.1    Chiche, G.J.2    Swift, E.J.3
  • 6
    • 79957836556 scopus 로고    scopus 로고
    • Bio-emulation: biomimetically emulating nature utilizing a histoanatomic approach; structural analysis
    • Bazos P, Magne P. Bio-emulation: biomimetically emulating nature utilizing a histoanatomic approach; structural analysis. Eur J Esthet Dent 2011; 6:8-19.
    • (2011) Eur J Esthet Dent , vol.6 , pp. 8-19
    • Bazos, P.1    Magne, P.2
  • 7
    • 33644668592 scopus 로고    scopus 로고
    • A new index for rating aesthetics of implant-supported single crowns and adjacent soft tissues - the Implant Crown Aesthetic Index
    • Meijer HJ, Stellingsma K, Meijndert L, Raghoebar GM. A new index for rating aesthetics of implant-supported single crowns and adjacent soft tissues - the Implant Crown Aesthetic Index. Clin Oral Implants Res 2005; 16:645-649.
    • (2005) Clin Oral Implants Res , vol.16 , pp. 645-649
    • Meijer, H.J.1    Stellingsma, K.2    Meijndert, L.3    Raghoebar, G.M.4
  • 8
    • 79952273419 scopus 로고    scopus 로고
    • Survival of zirconia- and metal-supported fixed dental prostheses: a systematic review
    • Heintze SD, Rousson V. Survival of zirconia- and metal-supported fixed dental prostheses: a systematic review. Int J Prosthodont 2010; 23:493-502.
    • (2010) Int J Prosthodont , vol.23 , pp. 493-502
    • Heintze, S.D.1    Rousson, V.2
  • 9
    • 0037812257 scopus 로고    scopus 로고
    • A long-term retrospective and clinical follow-up study of In-Ceram alumina FDPs
    • Olsson KG, Furst B, Andersson B, Carlsson GE. A long-term retrospective and clinical follow-up study of In-Ceram alumina FDPs. Int J Prosthodont 2003; 16:150-156.
    • (2003) Int J Prosthodont , vol.16 , pp. 150-156
    • Olsson, K.G.1    Furst, B.2    Andersson, B.3    Carlsson, G.E.4
  • 10
    • 0035408488 scopus 로고    scopus 로고
    • Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs
    • Vult von Steyern P, Jönsson O, Nilner K. Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs. Int J Prosthodont 2001; 14:379-384.
    • (2001) Int J Prosthodont , vol.14 , pp. 379-384
    • Vult von Steyern, P.1    Jönsson, O.2    Nilner, K.3
  • 11
    • 84863821283 scopus 로고    scopus 로고
    • A randomized, prospective, open-ended clinical trial of zirconia fixed partial dentures on teeth and implants: interim results
    • Sagirkaya E, Arikan S, Sadik B, Kara C, Karasoy D, Cehreli M. A randomized, prospective, open-ended clinical trial of zirconia fixed partial dentures on teeth and implants: interim results. Int J Prosthodont 2012; 25:221-231.
    • (2012) Int J Prosthodont , vol.25 , pp. 221-231
    • Sagirkaya, E.1    Arikan, S.2    Sadik, B.3    Kara, C.4    Karasoy, D.5    Cehreli, M.6
  • 12
    • 4344684951 scopus 로고    scopus 로고
    • Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs
    • Esquivel-Upshaw JF, Anusavice KJ, Young H, Jones J, Gibbs C. Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs. Int J Prosthodont 2004; 17:469-475.
    • (2004) Int J Prosthodont , vol.17 , pp. 469-475
    • Esquivel-Upshaw, J.F.1    Anusavice, K.J.2    Young, H.3    Jones, J.4    Gibbs, C.5
  • 13
    • 0032917811 scopus 로고    scopus 로고
    • Zirconia as a ceramic biomaterial
    • Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials 1999; 20:1-25.
    • (1999) Biomaterials , vol.20 , pp. 1-25
    • Piconi, C.1    Maccauro, G.2
  • 15
    • 1642312001 scopus 로고    scopus 로고
    • Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study
    • Scarano A, Piattelli M, Caputi S, Favero GA, Piattelli A. Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study. J Periodontol 2004; 75:292-296.
    • (2004) J Periodontol , vol.75 , pp. 292-296
    • Scarano, A.1    Piattelli, M.2    Caputi, S.3    Favero, G.A.4    Piattelli, A.5
  • 16
    • 36849045738 scopus 로고    scopus 로고
    • Chemical solubility and flexural strength of zirconia-based ceramics
    • Chai J, Chu FC, Chow TW, Liang BM. Chemical solubility and flexural strength of zirconia-based ceramics. Int J Prosthodont 2007; 20:587-595.
    • (2007) Int J Prosthodont , vol.20 , pp. 587-595
    • Chai, J.1    Chu, F.C.2    Chow, T.W.3    Liang, B.M.4
  • 17
    • 48749100438 scopus 로고    scopus 로고
    • The effect of all-ceramic and porcelain-fused-to-metal restorations on marginal peri-implant soft tissue color: a randomized controlled clinical trial
    • Jung RE, Holderegger C, Sailer I, Khraisat A, Suter A, Hämmerle CH. The effect of all-ceramic and porcelain-fused-to-metal restorations on marginal peri-implant soft tissue color: a randomized controlled clinical trial. Int J Periodontics Restorative Dent 2008; 28:357-365.
    • (2008) Int J Periodontics Restorative Dent , vol.28 , pp. 357-365
    • Jung, R.E.1    Holderegger, C.2    Sailer, I.3    Khraisat, A.4    Suter, A.5    Hämmerle, C.H.6
  • 18
    • 77955216069 scopus 로고    scopus 로고
    • Immediate loading of the maxilla with prefabricated interim prosthesis using interactive planning software, and CAD/CAM rehabilitation with definitive zirconia prosthesis: 2-year clinical follow-up
    • Papaspyridakos P, Lal K. Immediate loading of the maxilla with prefabricated interim prosthesis using interactive planning software, and CAD/CAM rehabilitation with definitive zirconia prosthesis: 2-year clinical follow-up. J Esthet Restor Dent 2010; 22:223-232.
    • (2010) J Esthet Restor Dent , vol.22 , pp. 223-232
    • Papaspyridakos, P.1    Lal, K.2
  • 20
    • 0032160238 scopus 로고    scopus 로고
    • The mucosal attachment at different abutments. An experimental study in dogs
    • Abrahamsson I, Berglundh T, Glantz PO, Lindhe J. The mucosal attachment at different abutments. An experimental study in dogs. J Clin Periodontol 1998; 25:721-727.
    • (1998) J Clin Periodontol , vol.25 , pp. 721-727
    • Abrahamsson, I.1    Berglundh, T.2    Glantz, P.O.3    Lindhe, J.4
  • 21
    • 84855865514 scopus 로고    scopus 로고
    • Surface properties of titanium and zirconia dental implant materials and their effect on bacterial adhesion
    • Al-Radha AS, Dymock D, Younes C, O'Sullivan D. Surface properties of titanium and zirconia dental implant materials and their effect on bacterial adhesion. J Dent 2012; 40:146-153.
    • (2012) J Dent , vol.40 , pp. 146-153
    • Al-Radha, A.S.1    Dymock, D.2    Younes, C.3    O'Sullivan, D.4
  • 22
    • 2542639442 scopus 로고    scopus 로고
    • Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study
    • Glauser R, Sailer I, Wohlwend A, Studer S, Schibli M, Schärer P. Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study. Int J Prosthodont 2004; 17:285-290.
    • (2004) Int J Prosthodont , vol.17 , pp. 285-290
    • Glauser, R.1    Sailer, I.2    Wohlwend, A.3    Studer, S.4    Schibli, M.5    Schärer, P.6
  • 23
    • 84876100541 scopus 로고    scopus 로고
    • Computer-assisted design/computer-assisted manufacturing zirconia implant fixed complete prostheses: clinical results and technical complications up to 4 years of function
    • Papaspyridakos P, Lal K. Computer-assisted design/computer-assisted manufacturing zirconia implant fixed complete prostheses: clinical results and technical complications up to 4 years of function. Clin Oral Impl Res 2013; 24:659-665.
    • (2013) Clin Oral Impl Res , vol.24 , pp. 659-665
    • Papaspyridakos, P.1    Lal, K.2
  • 24
    • 50349100818 scopus 로고    scopus 로고
    • Complete arch implant rehabilitation using subtractive rapid prototyping and porcelain fused to zirconia prosthesis: a clinical report
    • Papaspyridakos P, Lal K. Complete arch implant rehabilitation using subtractive rapid prototyping and porcelain fused to zirconia prosthesis: a clinical report. J Prosthet Dent 2008; 100:165-172.
    • (2008) J Prosthet Dent , vol.100 , pp. 165-172
    • Papaspyridakos, P.1    Lal, K.2
  • 26
  • 27
    • 77957270939 scopus 로고    scopus 로고
    • A prospective study of implant-supported full-arch yttria-stabilized tetragonal zirconia polycrystal mandibular fixed dental prostheses: three-year results
    • Larsson C, Vult von Steyern P, Nilner K. A prospective study of implant-supported full-arch yttria-stabilized tetragonal zirconia polycrystal mandibular fixed dental prostheses: three-year results. Int J Prosthodont 2010; 23:364-369.
    • (2010) Int J Prosthodont , vol.23 , pp. 364-369
    • Larsson, C.1    Vult von Steyern, P.2    Nilner, K.3
  • 28
    • 77952296078 scopus 로고    scopus 로고
    • Prospective evaluation of zirconia posterior fixed partial dentures: four-year clinical results
    • Roediger M, Gersdorff N, Huels A, Rinke S. Prospective evaluation of zirconia posterior fixed partial dentures: four-year clinical results. Int J Prosthodont 2010; 23:141-148.
    • (2010) Int J Prosthodont , vol.23 , pp. 141-148
    • Roediger, M.1    Gersdorff, N.2    Huels, A.3    Rinke, S.4
  • 29
    • 33846044794 scopus 로고    scopus 로고
    • Cyclic fatigue in water of veneer-framework composites for all-ceramic dental bridges
    • Studart AR, Filser F, Kocher P, Lüthy H, Gauckler LJ. Cyclic fatigue in water of veneer-framework composites for all-ceramic dental bridges. Dent Mater 2007; 23:177-185.
    • (2007) Dent Mater , vol.23 , pp. 177-185
    • Studart, A.R.1    Filser, F.2    Kocher, P.3    Lüthy, H.4    Gauckler, L.J.5
  • 30
    • 52249105571 scopus 로고    scopus 로고
    • Flexural and shear strengths of ZrO2 and a high-noble alloy bonded to their corresponding porcelains
    • Ashkanani HM, Raigrodski AJ, Flinn BD, Heindl H, Mancl LA. Flexural and shear strengths of ZrO2 and a high-noble alloy bonded to their corresponding porcelains. J Prosthet Dent 2008; 100:274-284.
    • (2008) J Prosthet Dent , vol.100 , pp. 274-284
    • Ashkanani, H.M.1    Raigrodski, A.J.2    Flinn, B.D.3    Heindl, H.4    Mancl, L.A.5
  • 32
    • 84858050429 scopus 로고    scopus 로고
    • Survival and complications of zirconia-based fixed dental prostheses: a systematic review
    • Raigrodski AJ, Hillstead MB, Meng GK, Chung KH. Survival and complications of zirconia-based fixed dental prostheses: a systematic review. J Prosthet Dent 2012; 107:170-177.
    • (2012) J Prosthet Dent , vol.107 , pp. 170-177
    • Raigrodski, A.J.1    Hillstead, M.B.2    Meng, G.K.3    Chung, K.H.4
  • 34
    • 34250625230 scopus 로고    scopus 로고
    • Comparison of survival and complication rates of tooth-supported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs)
    • Pjetursson BE, Brägger U, Lang NP, Zwahlen M. Comparison of survival and complication rates of tooth-supported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs). Clin Oral Implants Res 2007; 18:97-113.
    • (2007) Clin Oral Implants Res , vol.18 , pp. 97-113
    • Pjetursson, B.E.1    Brägger, U.2    Lang, N.P.3    Zwahlen, M.4
  • 35
    • 33745810915 scopus 로고    scopus 로고
    • All-ceramic two- to five-unit implant-supported reconstructions. A randomized, prospective clinical trial
    • Larsson C, Vult von Steyern P, Sunzel B, Nilner K. All-ceramic two- to five-unit implant-supported reconstructions. A randomized, prospective clinical trial. Swed Dent J 2006; 30:45-53.
    • (2006) Swed Dent J , vol.30 , pp. 45-53
    • Larsson, C.1    Vult von Steyern, P.2    Sunzel, B.3    Nilner, K.4
  • 36
    • 39649090053 scopus 로고    scopus 로고
    • The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies
    • von Elm E, Altman DG, Egger M, Pocock SJ, Gøtzsche PC, Vandenbroucke JP, STROBE Initiative. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies. J Clin Epidemiol 2008; 61:344-349.
    • (2008) J Clin Epidemiol , vol.61 , pp. 344-349
    • von Elm, E.1    Altman, D.G.2    Egger, M.3    Pocock, S.J.4    Gøtzsche, P.C.5    Vandenbroucke, J.P.6
  • 37
    • 80054047850 scopus 로고    scopus 로고
    • Bruxism and prosthetic treatment: a critical review
    • Johansson A, Omar R, Carlsson GE. Bruxism and prosthetic treatment: a critical review. J Prosthodont Res 2011; 55:127-136.
    • (2011) J Prosthodont Res , vol.55 , pp. 127-136
    • Johansson, A.1    Omar, R.2    Carlsson, G.E.3
  • 38
    • 20744446711 scopus 로고    scopus 로고
    • A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study
    • van Steenberghe D, Glauser R, Blombäck U, etal. A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study. Clin Implant Dent Relat Res 2005; 7(Suppl 1):S111-S120.
    • (2005) Clin Implant Dent Relat Res , vol.7 , pp. S111-S120
    • van Steenberghe, D.1    Glauser, R.2    Blombäck, U.3
  • 39
    • 0018535137 scopus 로고
    • Fabrication of a custom anterior guide table
    • Naylor CK. Fabrication of a custom anterior guide table. J Prosthet Dent 1979; 42:466-469.
    • (1979) J Prosthet Dent , vol.42 , pp. 466-469
    • Naylor, C.K.1
  • 40
    • 77958090670 scopus 로고    scopus 로고
    • Fit of zirconia fixed partial denture: a systematic review
    • Abduo J, Lyons K, Swain M. Fit of zirconia fixed partial denture: a systematic review. J Oral Rehabil 2010; 37:866-876.
    • (2010) J Oral Rehabil , vol.37 , pp. 866-876
    • Abduo, J.1    Lyons, K.2    Swain, M.3
  • 42
    • 67349133480 scopus 로고    scopus 로고
    • Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures
    • Swain MV. Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures. Acta Biomater 2009; 5:1668-1677.
    • (2009) Acta Biomater , vol.5 , pp. 1668-1677
    • Swain, M.V.1
  • 43
    • 0031089388 scopus 로고    scopus 로고
    • Outcomes and their measurement in clinical trials of endosseous oral implants
    • Van Steenberghe D. Outcomes and their measurement in clinical trials of endosseous oral implants. Ann Periodontol 1997; 2:291-298.
    • (1997) Ann Periodontol , vol.2 , pp. 291-298
    • Van Steenberghe, D.1
  • 45
    • 0032082427 scopus 로고    scopus 로고
    • The diagnosis and treatment of peri-implantitis
    • Mombelli A, Lang NP. The diagnosis and treatment of peri-implantitis. Periodontol 2000 1998; 17:63-76.
    • (1998) Periodontol 2000 , vol.17 , pp. 63-76
    • Mombelli, A.1    Lang, N.P.2
  • 46
    • 79952260010 scopus 로고    scopus 로고
    • Five-year follow-up of implant-supported Y-TZP and ZTA fixed dental prostheses. A randomized, prospective clinical trial comparing two different material systems
    • Larsson C, Vult von Steyern P. Five-year follow-up of implant-supported Y-TZP and ZTA fixed dental prostheses. A randomized, prospective clinical trial comparing two different material systems. Int J Prosthodont 2010; 23:555-561.
    • (2010) Int J Prosthodont , vol.23 , pp. 555-561
    • Larsson, C.1    Vult von Steyern, P.2
  • 47
    • 79960088342 scopus 로고    scopus 로고
    • Current status of zirconia-based fixed restorations
    • Komine F, Blatz MB, Matsumura H. Current status of zirconia-based fixed restorations. J Oral Sci 2010; 52:531-539.
    • (2010) J Oral Sci , vol.52 , pp. 531-539
    • Komine, F.1    Blatz, M.B.2    Matsumura, H.3
  • 48
    • 70350059154 scopus 로고    scopus 로고
    • Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crowns
    • Rosentritt M, Steiger D, Behr M, Handel G, Kolbeck C. Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crowns. J Dent 2009; 37:978-983.
    • (2009) J Dent , vol.37 , pp. 978-983
    • Rosentritt, M.1    Steiger, D.2    Behr, M.3    Handel, G.4    Kolbeck, C.5
  • 49
    • 84862173910 scopus 로고    scopus 로고
    • Fracture strength of yttria-stabilized tetragonal zirconia polycrystals crowns with different design: an in vitro study
    • Larsson C, El Madhoun S, Wennerberg A, Vult von Steyern P. Fracture strength of yttria-stabilized tetragonal zirconia polycrystals crowns with different design: an in vitro study. Clin Oral Impl Res 2012; 23:820-826.
    • (2012) Clin Oral Impl Res , vol.23 , pp. 820-826
    • Larsson, C.1    El Madhoun, S.2    Wennerberg, A.3    Vult von Steyern, P.4
  • 50
    • 7744239922 scopus 로고    scopus 로고
    • Effect of sandblasting on the long-term performance of dental ceramics
    • Zhang Y, Lawn B, Rekow E. Effect of sandblasting on the long-term performance of dental ceramics. J Biomed Mater Res B Appl Biomater 2004; 71:381-386.
    • (2004) J Biomed Mater Res B Appl Biomater , vol.71 , pp. 381-386
    • Zhang, Y.1    Lawn, B.2    Rekow, E.3
  • 51
    • 70349105523 scopus 로고    scopus 로고
    • Stresses and distortions within zirconia-fixed dental prostheses due to the veneering process
    • Dittmer MP, Borchers L, Stiesch M, Kohorst P. Stresses and distortions within zirconia-fixed dental prostheses due to the veneering process. Acta Biomater 2009; 5:3231-3239.
    • (2009) Acta Biomater , vol.5 , pp. 3231-3239
    • Dittmer, M.P.1    Borchers, L.2    Stiesch, M.3    Kohorst, P.4
  • 52
    • 46249121351 scopus 로고    scopus 로고
    • Mechanical properties of dental zirconia ceramics changed with sandblasting and heat treatment
    • Sato H, Yamada K, Pezzotti G, Nawa M, Ban S. Mechanical properties of dental zirconia ceramics changed with sandblasting and heat treatment. Dent Mater J 2008; 27:408-414.
    • (2008) Dent Mater J , vol.27 , pp. 408-414
    • Sato, H.1    Yamada, K.2    Pezzotti, G.3    Nawa, M.4    Ban, S.5
  • 53
    • 37049008682 scopus 로고    scopus 로고
    • Analyses of layer-thickness effects in bilayered dental ceramics subjected to thermal stresses and ring-on-ring tests
    • Hsueh CH, Thompson GA, Jadaan OM, Wereszczak AA, Becher PF. Analyses of layer-thickness effects in bilayered dental ceramics subjected to thermal stresses and ring-on-ring tests. Dent Mater 2008; 24:9-17.
    • (2008) Dent Mater , vol.24 , pp. 9-17
    • Hsueh, C.H.1    Thompson, G.A.2    Jadaan, O.M.3    Wereszczak, A.A.4    Becher, P.F.5
  • 54
    • 47249123700 scopus 로고    scopus 로고
    • The effects of viscoelastic parameters on residual stress development in a zirconia/glass bilayer dental ceramic
    • Taskonak B, Borges GA, Mecholsky JJ Jr, Anusavice KJ, Moore BK, Yan J. The effects of viscoelastic parameters on residual stress development in a zirconia/glass bilayer dental ceramic. Dent Mater 2008; 24:1149-1155.
    • (2008) Dent Mater , vol.24 , pp. 1149-1155
    • Taskonak, B.1    Borges, G.A.2    Mecholsky, J.J.3    Anusavice, K.J.4    Moore, B.K.5    Yan, J.6
  • 55
    • 11844264547 scopus 로고    scopus 로고
    • Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramics
    • Guazzato M, Quach L, Albakry M, Swain MV. Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramics. J Dent 2005; 33:9-18.
    • (2005) J Dent , vol.33 , pp. 9-18
    • Guazzato, M.1    Quach, L.2    Albakry, M.3    Swain, M.V.4
  • 57
    • 0242289420 scopus 로고    scopus 로고
    • The influence of the veneering porcelain and different surface treatments on the biaxial flexural strength of a heat-pressed ceramic
    • Isgro G, Pallav P, van der Zel JM, Feilzer AJ. The influence of the veneering porcelain and different surface treatments on the biaxial flexural strength of a heat-pressed ceramic. J Prosthet Dent 2003; 90:465-473.
    • (2003) J Prosthet Dent , vol.90 , pp. 465-473
    • Isgro, G.1    Pallav, P.2    van der Zel, J.M.3    Feilzer, A.J.4
  • 58
    • 46249127868 scopus 로고    scopus 로고
    • Effect of zirconia surface treatments on the shear strength of zirconia/vemeering ceramic composites
    • Fisher J, Grohmann P, Stawarczyk B. Effect of zirconia surface treatments on the shear strength of zirconia/vemeering ceramic composites. Dent Mater 2008; 27:448-454.
    • (2008) Dent Mater , vol.27 , pp. 448-454
    • Fisher, J.1    Grohmann, P.2    Stawarczyk, B.3
  • 59
    • 33745727941 scopus 로고    scopus 로고
    • Fracture resistance of all-ceramic zirconia bridges with differing phase stabilizers and quality of sintering
    • Sundh A, Sjögren G. Fracture resistance of all-ceramic zirconia bridges with differing phase stabilizers and quality of sintering. Dent Mater 2006; 22:778-784.
    • (2006) Dent Mater , vol.22 , pp. 778-784
    • Sundh, A.1    Sjögren, G.2
  • 63
    • 43049090522 scopus 로고    scopus 로고
    • Thermal compatibility of dental ceramic systems using cylindrical and spherical geometries
    • DeHoff PH, Barrett AA, Lee RB, Anusavice KJ. Thermal compatibility of dental ceramic systems using cylindrical and spherical geometries. Dent Mater 2008; 24:744-752.
    • (2008) Dent Mater , vol.24 , pp. 744-752
    • DeHoff, P.H.1    Barrett, A.A.2    Lee, R.B.3    Anusavice, K.J.4
  • 64
    • 58449098740 scopus 로고    scopus 로고
    • Peri-implantitis in partially edentulous patients: association with inadequate plaque control
    • Serino G, Ström C. Peri-implantitis in partially edentulous patients: association with inadequate plaque control. Clin Oral Implants Res 2009; 20:169-174.
    • (2009) Clin Oral Implants Res , vol.20 , pp. 169-174
    • Serino, G.1    Ström, C.2
  • 66
    • 0025028884 scopus 로고
    • Factors associated with soft- and hard-tissue compromise of endosseous implants
    • Block MS, Kent JN. Factors associated with soft- and hard-tissue compromise of endosseous implants. J Oral Maxillofac Surg 1990; 48:1153-1160.
    • (1990) J Oral Maxillofac Surg , vol.48 , pp. 1153-1160
    • Block, M.S.1    Kent, J.N.2
  • 67
    • 84870511289 scopus 로고    scopus 로고
    • 10-year follow-up of immediately loaded implants with tiunite porous anodized surface
    • Epub ahead of print
    • Degidi M, Nardi D, Piattelli A. 10-year follow-up of immediately loaded implants with tiunite porous anodized surface. Clin Implant Dent Relat Res 2012. [Epub ahead of print]
    • (2012) Clin Implant Dent Relat Res
    • Degidi, M.1    Nardi, D.2    Piattelli, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.