-
1
-
-
84355161961
-
The future of dental devices is digital
-
van Noort, R., The future of dental devices is digital. Dent Mater J 28 (2012), 3–12.
-
(2012)
Dent Mater J
, vol.28
, pp. 3-12
-
-
van Noort, R.1
-
2
-
-
63449088303
-
A review of dental CAD/CAM: current status and future perspectives from 20 years of experience
-
Miyazaki, T., Hotta, Y., Kunii, J., Kuriyama, S., Tamaki, Y., A review of dental CAD/CAM: current status and future perspectives from 20 years of experience. Dent Mater J 28 (2009), 44–56.
-
(2009)
Dent Mater J
, vol.28
, pp. 44-56
-
-
Miyazaki, T.1
Hotta, Y.2
Kunii, J.3
Kuriyama, S.4
Tamaki, Y.5
-
3
-
-
84909946382
-
A systematic review of CAD/CAM fit restoration evaluations
-
Boitelle, P., Mawussi, B., Tapie, L., Fromentin, O., A systematic review of CAD/CAM fit restoration evaluations. J Oral Rehabil 41 (2014), 853–874.
-
(2014)
J Oral Rehabil
, vol.41
, pp. 853-874
-
-
Boitelle, P.1
Mawussi, B.2
Tapie, L.3
Fromentin, O.4
-
4
-
-
44249116685
-
Digital dentistry: an overview of recent developments for CAD/CAM generated restorations
-
Beuer, F., Schweiger, J., Edelhoff, D., Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 204 (2008), 505–511.
-
(2008)
Br Dent J
, vol.204
, pp. 505-511
-
-
Beuer, F.1
Schweiger, J.2
Edelhoff, D.3
-
5
-
-
84865176071
-
Application of intra-oral dental scanners in the digital workflow of implantology
-
van der Meer, W.J., Andriessen, F.S., Wismeijer, D., Ren, Y., Application of intra-oral dental scanners in the digital workflow of implantology. PLoS One, 7, 2012, e43312.
-
(2012)
PLoS One
, vol.7
, pp. e43312
-
-
van der Meer, W.J.1
Andriessen, F.S.2
Wismeijer, D.3
Ren, Y.4
-
6
-
-
0026307196
-
CEREC CAD-CAM ceramic restorations. A case report after 5 years in place
-
Mormann, W.H., Curilović Z., CEREC CAD-CAM ceramic restorations. A case report after 5 years in place. Acta Stomatol Croat 25 (1991), 3–10.
-
(1991)
Acta Stomatol Croat
, vol.25
, pp. 3-10
-
-
Mormann, W.H.1
Curilović, Z.2
-
7
-
-
0026812671
-
Computer-designed inlays after 5 years in situ: clinical performance and scanning electron microscopic evaluation
-
Mörmann, W., Krejci, I., Computer-designed inlays after 5 years in situ: clinical performance and scanning electron microscopic evaluation. Quintessence Int 23 (1992), 109–115.
-
(1992)
Quintessence Int
, vol.23
, pp. 109-115
-
-
Mörmann, W.1
Krejci, I.2
-
8
-
-
33749241323
-
The evolution of the CEREC system
-
Mormann, W.H., The evolution of the CEREC system. J Am Dent Assoc 137:suppl (2006), 7S–13S.
-
(2006)
J Am Dent Assoc
, vol.137
, pp. 7S-13S
-
-
Mormann, W.H.1
-
9
-
-
77953432204
-
Evaluation of different methods of optical impression making on the marginal gap of onlays created with CEREC 3D
-
da Costa, J.B., Pelogia, F., Hagedorn, B., Ferracane, J.L., Evaluation of different methods of optical impression making on the marginal gap of onlays created with CEREC 3D. Oper Dent 35 (2010), 324–329.
-
(2010)
Oper Dent
, vol.35
, pp. 324-329
-
-
da Costa, J.B.1
Pelogia, F.2
Hagedorn, B.3
Ferracane, J.L.4
-
10
-
-
0032617542
-
Clinical performance of CEREC ceramic inlays: a systematic review
-
Martin, N., Jedynakiewicz, N.M., Clinical performance of CEREC ceramic inlays: a systematic review. Dent Mater 15 (1999), 54–61.
-
(1999)
Dent Mater
, vol.15
, pp. 54-61
-
-
Martin, N.1
Jedynakiewicz, N.M.2
-
11
-
-
0141721827
-
Marginal and internal fit of Cerec 3 CAD/CAM all-ceramic crowns
-
Nakamura, T., Dei, N., Kojima, T., Wakabayashi, K., Marginal and internal fit of Cerec 3 CAD/CAM all-ceramic crowns. Int J Prosthodont 16 (2003), 244–248.
-
(2003)
Int J Prosthodont
, vol.16
, pp. 244-248
-
-
Nakamura, T.1
Dei, N.2
Kojima, T.3
Wakabayashi, K.4
-
12
-
-
84908325617
-
Microcomputed tomography evaluation of marginal fit of lithium disilicate crowns fabricated by using chairside CAD/CAM systems or the heat-pressing technique
-
Neves, F.D., Prado, C.J., Prudente, M.S., Carneiro, T.A., Zancopé K., Davi, L.R., et al. Microcomputed tomography evaluation of marginal fit of lithium disilicate crowns fabricated by using chairside CAD/CAM systems or the heat-pressing technique. J Prosthet Dent 112 (2014), 1134–1140.
-
(2014)
J Prosthet Dent
, vol.112
, pp. 1134-1140
-
-
Neves, F.D.1
Prado, C.J.2
Prudente, M.S.3
Carneiro, T.A.4
Zancopé, K.5
Davi, L.R.6
-
13
-
-
84929505553
-
Micrometric precision of prosthetic dental crowns obtained by optical scanning and computer-aided designing/computer-aided manufacturing system
-
das Neves, F.D., de Almeida Prado Naves Carneiro, T., do Prado, C.J., Prudente, M.S., Zancopé K., Davi, L.R., et al. Micrometric precision of prosthetic dental crowns obtained by optical scanning and computer-aided designing/computer-aided manufacturing system. J Biomed Opt, 19, 2014, 088003.
-
(2014)
J Biomed Opt
, vol.19
, pp. 088003
-
-
das Neves, F.D.1
de Almeida Prado Naves Carneiro, T.2
do Prado, C.J.3
Prudente, M.S.4
Zancopé, K.5
Davi, L.R.6
-
14
-
-
84942307886
-
Microcomputed tomography marginal fit evaluation of computer-aided design/computer-aided manufacturing crowns with different methods of virtual model acquisition
-
das Neves, F.D., do Prado, C.J., Prudente, M.S., Carneiro, T.A., Zancope, K., Davi, L.R., et al. Microcomputed tomography marginal fit evaluation of computer-aided design/computer-aided manufacturing crowns with different methods of virtual model acquisition. Gen Dent 63 (2015), 39–42.
-
(2015)
Gen Dent
, vol.63
, pp. 39-42
-
-
das Neves, F.D.1
do Prado, C.J.2
Prudente, M.S.3
Carneiro, T.A.4
Zancope, K.5
Davi, L.R.6
-
15
-
-
84942986932
-
Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients
-
Boeddinghaus, M., Breloer, E.S., Rehmann, P., Wöstmann, B., Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients. Clin Oral Investig 19 (2015), 2027–2034.
-
(2015)
Clin Oral Investig
, vol.19
, pp. 2027-2034
-
-
Boeddinghaus, M.1
Breloer, E.S.2
Rehmann, P.3
Wöstmann, B.4
-
16
-
-
84942987286
-
Influence of material surface on the scanning error of a powder-free 3D measuring system
-
Kurz, M., Attin, T., Mehl, A., Influence of material surface on the scanning error of a powder-free 3D measuring system. Clin Oral Investig 19 (2015), 2035–2043.
-
(2015)
Clin Oral Investig
, vol.19
, pp. 2035-2043
-
-
Kurz, M.1
Attin, T.2
Mehl, A.3
-
17
-
-
84946039426
-
Effect of software version and parameter settings on the marginal and internal adaptation of crowns fabricated with the CAD/CAM system
-
Shim, J.S., Lee, J.S., Lee, J.Y., Choi, Y.J., Shin, S.W., Ryu, J.J., Effect of software version and parameter settings on the marginal and internal adaptation of crowns fabricated with the CAD/CAM system. J Appl Oral Sci 23 (2015), 515–522.
-
(2015)
J Appl Oral Sci
, vol.23
, pp. 515-522
-
-
Shim, J.S.1
Lee, J.S.2
Lee, J.Y.3
Choi, Y.J.4
Shin, S.W.5
Ryu, J.J.6
-
18
-
-
59049089425
-
Accuracy testing of a new intraoral 3D camera
-
Mehl, A., Ender, A., Mormann, W., Attin, T., Accuracy testing of a new intraoral 3D camera. Int J Comput Dent 12 (2009), 11–28.
-
(2009)
Int J Comput Dent
, vol.12
, pp. 11-28
-
-
Mehl, A.1
Ender, A.2
Mormann, W.3
Attin, T.4
-
19
-
-
0024722843
-
A rationale for comparison of plaque-retaining properties of crown systems
-
Sorensen, J.A., A rationale for comparison of plaque-retaining properties of crown systems. J Prosthet Dent 62 (1989), 264–269.
-
(1989)
J Prosthet Dent
, vol.62
, pp. 264-269
-
-
Sorensen, J.A.1
-
20
-
-
84863776195
-
Effects of cement thickness and bonding on the failure loads of CAD/CAM ceramic crowns: multi-physics FEA modeling and monotonic testing
-
May, L.G., Kelly, J.R., Bottino, M.A., Hill, T., Effects of cement thickness and bonding on the failure loads of CAD/CAM ceramic crowns: multi-physics FEA modeling and monotonic testing. Dent Mater 28 (2012), e99–e109.
-
(2012)
Dent Mater
, vol.28
, pp. e99-e109
-
-
May, L.G.1
Kelly, J.R.2
Bottino, M.A.3
Hill, T.4
-
21
-
-
84984871101
-
Effect of operators’ experience and cement space on the marginal fit of an in-office digitally produced monolithic ceramic crown system
-
Baig, M.R., Gonzalez, M.A., Abu Kasim, N.H., Abu Kassim, N.L., Farook, M.S., Effect of operators’ experience and cement space on the marginal fit of an in-office digitally produced monolithic ceramic crown system. Quintessence Int 47 (2016), 181–191.
-
(2016)
Quintessence Int
, vol.47
, pp. 181-191
-
-
Baig, M.R.1
Gonzalez, M.A.2
Abu Kasim, N.H.3
Abu Kassim, N.L.4
Farook, M.S.5
-
22
-
-
30144445945
-
A method of verifying and improving internal fit of all-ceramic restorations
-
Jahangiri, L., Estafan, D., A method of verifying and improving internal fit of all-ceramic restorations. J Prosthet Dent 95 (2006), 82–83.
-
(2006)
J Prosthet Dent
, vol.95
, pp. 82-83
-
-
Jahangiri, L.1
Estafan, D.2
-
23
-
-
84940062404
-
Machinability of lithium disilicate glass ceramic in vitro dental diamond bur adjusting process
-
Song, X.F., Ren, H.T., Yin, L., Machinability of lithium disilicate glass ceramic in vitro dental diamond bur adjusting process. J Mech Behav Biomed Mater 53 (2016), 78–92.
-
(2016)
J Mech Behav Biomed Mater
, vol.53
, pp. 78-92
-
-
Song, X.F.1
Ren, H.T.2
Yin, L.3
-
24
-
-
0015209415
-
The estimation of cement film thickness by an in vivo technique
-
McLean, J.W., von Fraunhofer, J.A., The estimation of cement film thickness by an in vivo technique. Br Dent J 131 (1971), 107–111.
-
(1971)
Br Dent J
, vol.131
, pp. 107-111
-
-
McLean, J.W.1
von Fraunhofer, J.A.2
|