메뉴 건너뛰기




Volumn 19, Issue 8, 2015, Pages 2035-2043

Influence of material surface on the scanning error of a powder-free 3D measuring system

Author keywords

Accuracy; CAD CAM; Digital workflow; Impression technique; Intraoral scanning

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS;

EID: 84942987286     PISSN: 14326981     EISSN: 14363771     Source Type: Journal    
DOI: 10.1007/s00784-015-1440-5     Document Type: Article
Times cited : (81)

References (34)
  • 2
    • 84882956743 scopus 로고    scopus 로고
    • Intraoral optical impression systems—an overview
    • PID: 23930576
    • Reich S, Vollborn T, Mehl A, Zimmermann M (2013) Intraoral optical impression systems—an overview. Int J Comput Dent 16:143–162
    • (2013) Int J Comput Dent , vol.16 , pp. 143-162
    • Reich, S.1    Vollborn, T.2    Mehl, A.3    Zimmermann, M.4
  • 3
    • 0034305681 scopus 로고    scopus 로고
    • The optical conditioning of Cerec preparations with scan spray
    • PID: 11410974
    • Kurbad A (2000) The optical conditioning of Cerec preparations with scan spray. Int J Comput Dent 3:269–279
    • (2000) Int J Comput Dent , vol.3 , pp. 269-279
    • Kurbad, A.1
  • 4
    • 0025656535 scopus 로고
    • Optimization of the powder application in the Cerec method with environment-friendly propellant systems
    • Meyer BJ, Mormann WH, Lutz F (1990) Optimization of the powder application in the Cerec method with environment-friendly propellant systems. Schweiz Monatsschr Zahnmed 100:1462–1468
    • (1990) Schweiz Monatsschr Zahnmed , vol.100 , pp. 1462-1468
    • Meyer, B.J.1    Mormann, W.H.2    Lutz, F.3
  • 5
    • 84873578014 scopus 로고    scopus 로고
    • Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision
    • PID: 23395338
    • Ender A, Mehl A (2013) Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision. J Prosthet Dent 109:121–128
    • (2013) J Prosthet Dent , vol.109 , pp. 121-128
    • Ender, A.1    Mehl, A.2
  • 6
    • 84879134365 scopus 로고    scopus 로고
    • Accuracy of dies captured by an intraoral digital impression system using parallel confocal imaging
    • PID: 23476911
    • Kim SY, Kim MJ, Han JS, Yeo IS, Lim YJ, Kwon HB (2013) Accuracy of dies captured by an intraoral digital impression system using parallel confocal imaging. Int J Prosthodont 26:161–163
    • (2013) Int J Prosthodont , vol.26 , pp. 161-163
    • Kim, S.Y.1    Kim, M.J.2    Han, J.S.3    Yeo, I.S.4    Lim, Y.J.5    Kwon, H.B.6
  • 9
    • 58149089206 scopus 로고    scopus 로고
    • Measurement of translucency of tooth enamel and dentin
    • PID: 19037822
    • Yu B, Ahn JS, Lee YK (2009) Measurement of translucency of tooth enamel and dentin. Acta Odontol Scand 67:57–64
    • (2009) Acta Odontol Scand , vol.67 , pp. 57-64
    • Yu, B.1    Ahn, J.S.2    Lee, Y.K.3
  • 10
    • 28844451419 scopus 로고    scopus 로고
    • Color and translucency of resin composites for layering techniques
    • PID: 16279735
    • Kamishima N, Ikeda T, Sano H (2005) Color and translucency of resin composites for layering techniques. Dent Mater J 24:428–432
    • (2005) Dent Mater J , vol.24 , pp. 428-432
    • Kamishima, N.1    Ikeda, T.2    Sano, H.3
  • 11
    • 52049116314 scopus 로고    scopus 로고
    • Translucency of varied brand and shade of resin composites
    • PID: 18795518
    • Yu B, Lee YK (2008) Translucency of varied brand and shade of resin composites. Am J Dent 21:229–232
    • (2008) Am J Dent , vol.21 , pp. 229-232
    • Yu, B.1    Lee, Y.K.2
  • 12
    • 50849085447 scopus 로고    scopus 로고
    • Differences in color, translucency and fluorescence between flowable and universal resin composites
    • PID: 18621459
    • Yu B, Lee YK (2008) Differences in color, translucency and fluorescence between flowable and universal resin composites. J Dent 36:840–846
    • (2008) J Dent , vol.36 , pp. 840-846
    • Yu, B.1    Lee, Y.K.2
  • 13
    • 58149152973 scopus 로고    scopus 로고
    • Translucency and masking ability of various opaque-shade composite resins
    • PID: 19028004
    • Kim SJ, Son HH, Cho BH, Lee IB, Um CM (2009) Translucency and masking ability of various opaque-shade composite resins. J Dent 37:102–107
    • (2009) J Dent , vol.37 , pp. 102-107
    • Kim, S.J.1    Son, H.H.2    Cho, B.H.3    Lee, I.B.4    Um, C.M.5
  • 14
    • 79952025356 scopus 로고    scopus 로고
    • Comparative translucency of esthetic composite resin restorative materials
    • PID: 20719098
    • Ryan EA, Tam LE, McComb D (2010) Comparative translucency of esthetic composite resin restorative materials. J Can Dent Assoc 76:a84
    • (2010) J Can Dent Assoc , vol.76 , pp. 84
    • Ryan, E.A.1    Tam, L.E.2    McComb, D.3
  • 15
    • 77957285179 scopus 로고    scopus 로고
    • Translucency, opalescence and light transmission characteristics of light-cured resin composites
    • PID: 20692691
    • Arimoto A, Nakajima M, Hosaka K, Nishimura K, Ikeda M, Foxton RM, Tagami J (2010) Translucency, opalescence and light transmission characteristics of light-cured resin composites. Dent Mater 26:1090–1097
    • (2010) Dent Mater , vol.26 , pp. 1090-1097
    • Arimoto, A.1    Nakajima, M.2    Hosaka, K.3    Nishimura, K.4    Ikeda, M.5    Foxton, R.M.6    Tagami, J.7
  • 16
    • 84870882724 scopus 로고    scopus 로고
    • Light transmission characteristics of dentine and resin composites with different thickness
    • PID: 22955005
    • Nakajima M, Arimoto A, Prasansuttiporn T, Thanatvarakorn O, Foxton RM, Tagami J (2012) Light transmission characteristics of dentine and resin composites with different thickness. J Dent 40(Suppl 2):e77–e82
    • (2012) J Dent , vol.40 , pp. e77-e82
    • Nakajima, M.1    Arimoto, A.2    Prasansuttiporn, T.3    Thanatvarakorn, O.4    Foxton, R.M.5    Tagami, J.6
  • 17
    • 84855781988 scopus 로고    scopus 로고
    • Influences of composite-composite join on light transmission characteristics of layered resin composites
    • PID: 22056733
    • Horie K, Nakajima M, Hosaka K, Kainose K, Tanaka A, Foxton RM, Tagami J (2012) Influences of composite-composite join on light transmission characteristics of layered resin composites. Dent Mater 28:204–211
    • (2012) Dent Mater , vol.28 , pp. 204-211
    • Horie, K.1    Nakajima, M.2    Hosaka, K.3    Kainose, K.4    Tanaka, A.5    Foxton, R.M.6    Tagami, J.7
  • 18
  • 19
    • 84880285230 scopus 로고    scopus 로고
    • The effect of a coupling medium on color and translucency of CAD-CAM ceramics
    • PID: 23438417
    • Nogueira AD, Della Bona A (2013) The effect of a coupling medium on color and translucency of CAD-CAM ceramics. J Dent 41(Suppl 3):e18–e23
    • (2013) J Dent , vol.41 , pp. e18-e23
    • Nogueira, A.D.1    Della Bona, A.2
  • 20
    • 84856598708 scopus 로고    scopus 로고
    • Translucency of value resin composites used to replace enamel in stratified composite restoration techniques
    • Schmeling M, DE Andrada MA, Maia HP, DE Araújo EM (2012) Translucency of value resin composites used to replace enamel in stratified composite restoration techniques. J Esthet Restor Dent 24:53–58
    • (2012) J Esthet Restor Dent , vol.24 , pp. 53-58
    • Schmeling, M.1    DE Andrada, M.A.2    Maia, H.P.3    DE Araújo, E.M.4
  • 22
    • 0031278678 scopus 로고    scopus 로고
    • A new optical 3-D device for the detection of wear
    • PID: 9372798
    • Mehl A, Gloger W, Kunzelmann KH, Hickel R (1997) A new optical 3-D device for the detection of wear. J Dent Res 76:1799–1807
    • (1997) J Dent Res , vol.76 , pp. 1799-1807
    • Mehl, A.1    Gloger, W.2    Kunzelmann, K.H.3    Hickel, R.4
  • 23
    • 85017306032 scopus 로고    scopus 로고
    • In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions
    • PID: 25019118
    • Ender A, Mehl A (2015) In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions. Quintessence Int 46(1):9–17. doi:10.3290/j.qi.a32244
    • (2015) Quintessence Int , vol.46 , Issue.1 , pp. 9-17
    • Ender, A.1    Mehl, A.2
  • 24
    • 78649520201 scopus 로고    scopus 로고
    • Two- and three-dimensional accuracy of dental impression materials: effects of storage time and moisture contamination
    • Chandran DT, Jagger DC, Jagger RG, Barbour ME (2010) Two- and three-dimensional accuracy of dental impression materials: effects of storage time and moisture contamination. Biomed Mater Eng 20:243–249
    • (2010) Biomed Mater Eng , vol.20 , pp. 243-249
    • Chandran, D.T.1    Jagger, D.C.2    Jagger, R.G.3    Barbour, M.E.4
  • 25
    • 41449105763 scopus 로고    scopus 로고
    • Dimensional accuracy of resultant casts made by a monophase, one-step and two-step, and a novel two-step putty/light-body impression technique: an in vitro study
    • PID: 18395537
    • Caputi S, Varvara G (2008) Dimensional accuracy of resultant casts made by a monophase, one-step and two-step, and a novel two-step putty/light-body impression technique: an in vitro study. J Prosthet Dent 99:274–281
    • (2008) J Prosthet Dent , vol.99 , pp. 274-281
    • Caputi, S.1    Varvara, G.2
  • 26
    • 0041964167 scopus 로고    scopus 로고
    • The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions
    • PID: 12886207
    • Ceyhan JA, Johnson GH, Lepe X (2003) The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions. J Prosthet Dent 90:143–149
    • (2003) J Prosthet Dent , vol.90 , pp. 143-149
    • Ceyhan, J.A.1    Johnson, G.H.2    Lepe, X.3
  • 27
    • 33947147250 scopus 로고    scopus 로고
    • Computer-aided analysis of the influence of digitizing and surfacing on the accuracy in dental CAD/CAM technology
    • PID: 16844107
    • Rudolph H, Luthardt RG, Walter MH (2007) Computer-aided analysis of the influence of digitizing and surfacing on the accuracy in dental CAD/CAM technology. Comput Biol Med 37:579–587
    • (2007) Comput Biol Med , vol.37 , pp. 579-587
    • Rudolph, H.1    Luthardt, R.G.2    Walter, M.H.3
  • 28
    • 63849304492 scopus 로고    scopus 로고
    • Digital impression taking with reproducibly high precision
    • PID: 19413271
    • Ziegler M (2009) Digital impression taking with reproducibly high precision. Int J Comput Dent 12:159–163
    • (2009) Int J Comput Dent , vol.12 , pp. 159-163
    • Ziegler, M.1
  • 29
    • 67650388085 scopus 로고    scopus 로고
    • Accuracy of impressions obtained with dual-arch trays
    • PID: 19418862
    • Wostmann B, Rehmann P, Balkenhol M (2009) Accuracy of impressions obtained with dual-arch trays. Int J Prosthodont 22:158–160
    • (2009) Int J Prosthodont , vol.22 , pp. 158-160
    • Wostmann, B.1    Rehmann, P.2    Balkenhol, M.3
  • 30
    • 0036514487 scopus 로고    scopus 로고
    • In vitro study on the dimensional accuracy of selected materials for monophase elastic impression making
    • PID: 11951807
    • Piwowarczyk A, Ottl P, Buchler A, Lauer HC, Hoffmann A (2002) In vitro study on the dimensional accuracy of selected materials for monophase elastic impression making. Int J Prosthodont 15:168–174
    • (2002) Int J Prosthodont , vol.15 , pp. 168-174
    • Piwowarczyk, A.1    Ottl, P.2    Buchler, A.3    Lauer, H.C.4    Hoffmann, A.5
  • 31
    • 36849057638 scopus 로고    scopus 로고
    • Dimensional accuracy of 2-stage putty-wash impressions: influence of impression trays and viscosity
    • PID: 18069363
    • Balkenhol M, Ferger P, Wostmann B (2007) Dimensional accuracy of 2-stage putty-wash impressions: influence of impression trays and viscosity. Int J Prosthodont 20:573–575
    • (2007) Int J Prosthodont , vol.20 , pp. 573-575
    • Balkenhol, M.1    Ferger, P.2    Wostmann, B.3
  • 32
    • 84889078508 scopus 로고    scopus 로고
    • Recent advances in dental optics—Part I. 3D intraoral scanners for restorative dentistry
    • Logozzo S, Zanetti EM, Franceschini G, Kilpelä A, Mäkynen A (2014) Recent advances in dental optics—Part I. 3D intraoral scanners for restorative dentistry. Opt Lasers Eng 54:203–221
    • (2014) Opt Lasers Eng , vol.54 , pp. 203-221
    • Logozzo, S.1    Zanetti, E.M.2    Franceschini, G.3    Kilpelä, A.4    Mäkynen, A.5
  • 33
    • 84886412061 scopus 로고    scopus 로고
    • Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner
    • Flugge TV, Schlager S, Nelson K, Nahles S, Metzger MC (2013) Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofacial Orthop 144:471–478
    • (2013) Am J Orthod Dentofacial Orthop , vol.144 , pp. 471-478
    • Flugge, T.V.1    Schlager, S.2    Nelson, K.3    Nahles, S.4    Metzger, M.C.5
  • 34
    • 0141957583 scopus 로고    scopus 로고
    • Dimensional accuracy and surface detail reproduction of two hydrophilic vinyl polysiloxane impression materials tested under dry, moist, and wet conditions
    • PID: 14564291
    • Petrie CS, Walker MP, O’Mahony AM, Spencer P (2003) Dimensional accuracy and surface detail reproduction of two hydrophilic vinyl polysiloxane impression materials tested under dry, moist, and wet conditions. J Prosthet Dent 90:365–372
    • (2003) J Prosthet Dent , vol.90 , pp. 365-372
    • Petrie, C.S.1    Walker, M.P.2    O’Mahony, A.M.3    Spencer, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.