메뉴 건너뛰기




Volumn 26, Issue 1, 2019, Pages 284-287

Myocardial perfusion imaging in extreme obesity: Leveraging modern technologies to meet a modern challenge

Author keywords

[No Author keywords available]

Indexed keywords

TETROFOSMIN TC 99M; THALLIUM 201; RUBIDIUM; RUBIDIUM-82; TECHNETIUM;

EID: 85021119706     PISSN: 10713581     EISSN: 15326551     Source Type: Journal    
DOI: 10.1007/s12350-017-0956-2     Document Type: Editorial
Times cited : (6)

References (26)
  • 1
    • 84856487711 scopus 로고    scopus 로고
    • Prevalence of obesity and trends in the distribution of body mass index among US adults, 1999-2010
    • PID: 22253363
    • Flegal KM, Carroll MD, Kit BK, Ogden CL. Prevalence of obesity and trends in the distribution of body mass index among US adults, 1999-2010. JAMA. 2012;307:491–7
    • (2012) JAMA , vol.307 , pp. 491-497
    • Flegal, K.M.1    Carroll, M.D.2    Kit, B.K.3    Ogden, C.L.4
  • 2
    • 85010931754 scopus 로고    scopus 로고
    • Mechanisms, pathophysiology, and management of obesity
    • PID: 28099824
    • Heymsfield SB, Wadden TA. Mechanisms, pathophysiology, and management of obesity. N Engl J Med. 2017;376:254–66
    • (2017) N Engl J Med , vol.376 , pp. 254-266
    • Heymsfield, S.B.1    Wadden, T.A.2
  • 4
    • 84867840857 scopus 로고    scopus 로고
    • Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease?: A systematic review and meta-analysis
    • PID: 23040573
    • Mc Ardle BA, Dowsley TF, deKemp RA, Wells GA, Beanlands RS. Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease?: A systematic review and meta-analysis. J Am Coll Cardiol. 2012;60:1828–37
    • (2012) J Am Coll Cardiol , vol.60 , pp. 1828-1837
    • Mc Ardle, B.A.1    Dowsley, T.F.2    deKemp, R.A.3    Wells, G.A.4    Beanlands, R.S.5
  • 5
    • 84872244212 scopus 로고    scopus 로고
    • Diagnostic accuracy of cardiac positron emission tomography versus single photon emission computed tomography for coronary artery disease: A bivariate meta-analysis
    • PID: 23051888
    • Parker MW, Iskandar A, Limone B, Perugini A, Kim H, Jones C, et al. Diagnostic accuracy of cardiac positron emission tomography versus single photon emission computed tomography for coronary artery disease: A bivariate meta-analysis. Circ Cardiovasc Imaging. 2012;5:700–7
    • (2012) Circ Cardiovasc Imaging , vol.5 , pp. 700-707
    • Parker, M.W.1    Iskandar, A.2    Limone, B.3    Perugini, A.4    Kim, H.5    Jones, C.6
  • 6
    • 11844294090 scopus 로고    scopus 로고
    • Attenuation correction single-photon emission computed tomography myocardial perfusion imaging
    • PID: 15645393
    • Bateman TM, Cullom SJ. Attenuation correction single-photon emission computed tomography myocardial perfusion imaging. Semin Nucl Med. 2005;35:37–51
    • (2005) Semin Nucl Med , vol.35 , pp. 37-51
    • Bateman, T.M.1    Cullom, S.J.2
  • 7
    • 33645537373 scopus 로고    scopus 로고
    • One size fits all?
    • PID: 16580952
    • Hendel RC. One size fits all? J Nucl Cardiol. 2006;13:177–9
    • (2006) J Nucl Cardiol , vol.13 , pp. 177-179
    • Hendel, R.C.1
  • 8
    • 0031539281 scopus 로고    scopus 로고
    • Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging
    • PID: 9385894
    • Smanio PE, Watson DD, Segalla DL, Vinson EL, Smith WH, Beller GA. Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging. J Am Coll Cardiol. 1997;30:1687–92
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1687-1692
    • Smanio, P.E.1    Watson, D.D.2    Segalla, D.L.3    Vinson, E.L.4    Smith, W.H.5    Beller, G.A.6
  • 9
    • 33645394233 scopus 로고    scopus 로고
    • Diagnostic accuracy of gated Tc-99m sestamibi stress myocardial perfusion SPECT with combined supine and prone acquisitions to detect coronary artery disease in obese and nonobese patients
    • PID: 16580955
    • Berman DS, Kang X, Nishina H, Slomka PJ, Shaw LJ, Hayes SW, et al. Diagnostic accuracy of gated Tc-99m sestamibi stress myocardial perfusion SPECT with combined supine and prone acquisitions to detect coronary artery disease in obese and nonobese patients. J Nucl Cardiol. 2006;13:191–201
    • (2006) J Nucl Cardiol. , vol.13 , pp. 191-201
    • Berman, D.S.1    Kang, X.2    Nishina, H.3    Slomka, P.J.4    Shaw, L.J.5    Hayes, S.W.6
  • 10
    • 16244384528 scopus 로고    scopus 로고
    • Value of attenuation correction on ECG-gated SPECT myocardial perfusion imaging related to body mass index
    • PID: 15812374
    • Thompson RC, Heller GV, Johnson LL, Case JA, Cullom SJ, Garcia EV, et al. Value of attenuation correction on ECG-gated SPECT myocardial perfusion imaging related to body mass index. J Nucl Cardiol. 2005;12:195–202
    • (2005) J Nucl Cardiol. , vol.12 , pp. 195-202
    • Thompson, R.C.1    Heller, G.V.2    Johnson, L.L.3    Case, J.A.4    Cullom, S.J.5    Garcia, E.V.6
  • 11
    • 84901677342 scopus 로고    scopus 로고
    • Clinical value of supine and upright myocardial perfusion imaging in obese patients using the D-SPECT camera
    • PID: 24477404
    • Ben-Haim S, Almukhailed O, Neill J, Slomka P, Allie R, Shiti D, et al. Clinical value of supine and upright myocardial perfusion imaging in obese patients using the D-SPECT camera. J Nucl Cardiol. 2014;21:478–85
    • (2014) J Nucl Cardiol. , vol.21 , pp. 478-485
    • Ben-Haim, S.1    Almukhailed, O.2    Neill, J.3    Slomka, P.4    Allie, R.5    Shiti, D.6
  • 12
    • 84865525575 scopus 로고    scopus 로고
    • Evaluation of ischaemia in obese patients: Feasibility and accuracy of a low-dose protocol with a cadmium-zinc telluride camera
    • PID: 22699527
    • Gimelli A, Bottai M, Giorgetti A, Genovesi D, Filidei E, Marzullo P. Evaluation of ischaemia in obese patients: Feasibility and accuracy of a low-dose protocol with a cadmium-zinc telluride camera. Eur J Nucl Med Mol Imaging. 2012;39:1254–61
    • (2012) Eur J Nucl Med Mol Imaging , vol.39 , pp. 1254-1261
    • Gimelli, A.1    Bottai, M.2    Giorgetti, A.3    Genovesi, D.4    Filidei, E.5    Marzullo, P.6
  • 13
    • 67649619857 scopus 로고    scopus 로고
    • ACCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine
    • PID: 19451357
    • Hendel RC, Berman DS, Di Carli MF, Heidenreich PA, Henkin RE, Pellikka PA, et al. ACCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine. Circulation. 2009;119:e561–87
    • (2009) Circulation , vol.119 , pp. e561-e587
    • Hendel, R.C.1    Berman, D.S.2    Di Carli, M.F.3    Heidenreich, P.A.4    Henkin, R.E.5    Pellikka, P.A.6
  • 14
    • 0025605314 scopus 로고
    • A prospective comparison of rubidium-82 PET and thallium-201 SPECT myocardial perfusion imaging utilizing a single dipyridamole stress in the diagnosis of coronary artery disease
    • PID: 2266384
    • Go RT, Marwick TH, MacIntyre WJ, Saha GB, Neumann DR, Underwood DA, et al. A prospective comparison of rubidium-82 PET and thallium-201 SPECT myocardial perfusion imaging utilizing a single dipyridamole stress in the diagnosis of coronary artery disease. J Nucl Med. 1990;31:1899–905
    • (1990) J Nucl Med , vol.31 , pp. 1899-1905
    • Go, R.T.1    Marwick, T.H.2    MacIntyre, W.J.3    Saha, G.B.4    Neumann, D.R.5    Underwood, D.A.6
  • 15
    • 32044472882 scopus 로고    scopus 로고
    • Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT
    • Bateman TM, Heller GV, McGhie AI, Friedman JD, Case JA, Bryngelson JR, et al. Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT. J Nucl Med. 2006;13:24–33
    • (2006) J Nucl Med , vol.13 , pp. 24-33
    • Bateman, T.M.1    Heller, G.V.2    McGhie, A.I.3    Friedman, J.D.4    Case, J.A.5    Bryngelson, J.R.6
  • 16
    • 84978043037 scopus 로고    scopus 로고
    • Invasive FFR and noninvasive CFR in the evaluation of ischemia: What is the future?
    • PID: 27282899
    • Johnson NP, Gould KL, Di Carli MF, Taqueti VR. Invasive FFR and noninvasive CFR in the evaluation of ischemia: What is the future? J Am Coll Cardiol. 2016;67:2772–88
    • (2016) J Am Coll Cardiol , vol.67 , pp. 2772-2788
    • Johnson, N.P.1    Gould, K.L.2    Di Carli, M.F.3    Taqueti, V.R.4
  • 17
    • 11144221669 scopus 로고    scopus 로고
    • Identifying high-risk asymptomatic diabetic patients who are candidates for screening stress single-photon emission computed tomography imaging
    • PID: 15629371
    • Rajagopalan N, Miller TD, Hodge DO, Frye RL, Gibbons RJ. Identifying high-risk asymptomatic diabetic patients who are candidates for screening stress single-photon emission computed tomography imaging. J Am Coll Cardiol. 2005;45:43–9
    • (2005) J Am Coll Cardiol , vol.45 , pp. 43-49
    • Rajagopalan, N.1    Miller, T.D.2    Hodge, D.O.3    Frye, R.L.4    Gibbons, R.J.5
  • 18
    • 79955777624 scopus 로고    scopus 로고
    • Prediction of short-term cardiovascular events using quantification of global myocardial flow reserve in patients referred for clinical 82Rb PET perfusion imaging
    • PID: 21498538
    • Fukushima K, Javadi MS, Higuchi T, Lautamäki R, Merrill J, Nekolla SG, et al. Prediction of short-term cardiovascular events using quantification of global myocardial flow reserve in patients referred for clinical 82Rb PET perfusion imaging. J Nucl Med. 2011;52:726–32
    • (2011) J Nucl Med , vol.52 , pp. 726-732
    • Fukushima, K.1    Javadi, M.S.2    Higuchi, T.3    Lautamäki, R.4    Merrill, J.5    Nekolla, S.G.6
  • 19
    • 67649385766 scopus 로고    scopus 로고
    • Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography added value of coronary flow reserve
    • PID: 19573732
    • Herzog BA, Husmann L, Valenta I, Gaemperli O, Siegrist PT, Tay FM, et al. Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography added value of coronary flow reserve. J Am Coll Cardiol. 2009;54:150–6
    • (2009) J Am Coll Cardiol , vol.54 , pp. 150-156
    • Herzog, B.A.1    Husmann, L.2    Valenta, I.3    Gaemperli, O.4    Siegrist, P.T.5    Tay, F.M.6
  • 20
    • 81355146433 scopus 로고    scopus 로고
    • Improved cardiac risk assessment with noninvasive measures of coronary flow reserve
    • PID: 22007073
    • Murthy VL, Naya M, Foster CR, Hainer J, Gaber M, Di Carli G, et al. Improved cardiac risk assessment with noninvasive measures of coronary flow reserve. Circulation. 2011;124:2215–24
    • (2011) Circulation , vol.124 , pp. 2215-2224
    • Murthy, V.L.1    Naya, M.2    Foster, C.R.3    Hainer, J.4    Gaber, M.5    Di Carli, G.6
  • 21
    • 79961174089 scopus 로고    scopus 로고
    • Impaired myocardial flow reserve on rubidium-82 positron emission tomography imaging predicts adverse outcomes in patients assessed for myocardial ischemia
    • PID: 21816311
    • Ziadi MC, Dekemp RA, Williams KA, Chow BJ, Renaud JM, Ruddy T, et al. Impaired myocardial flow reserve on rubidium-82 positron emission tomography imaging predicts adverse outcomes in patients assessed for myocardial ischemia. J Am Coll Cardiol. 2011;58:740–8
    • (2011) J Am Coll Cardiol , vol.58 , pp. 740-748
    • Ziadi, M.C.1    Dekemp, R.A.2    Williams, K.A.3    Chow, B.J.4    Renaud, J.M.5    Ruddy, T.6
  • 22
    • 84923408091 scopus 로고    scopus 로고
    • Global coronary flow reserve is associated with adverse cardiovascular events independently of luminal angiographic severity and modifies the effect of early revascularization
    • PID: 25400060
    • Taqueti VR, Hachamovitch R, Murthy VL, Naya M, Foster CR, Hainer J, et al. Global coronary flow reserve is associated with adverse cardiovascular events independently of luminal angiographic severity and modifies the effect of early revascularization. Circulation. 2015;131:19–27
    • (2015) Circulation , vol.131 , pp. 19-27
    • Taqueti, V.R.1    Hachamovitch, R.2    Murthy, V.L.3    Naya, M.4    Foster, C.R.5    Hainer, J.6
  • 23
    • 85007426096 scopus 로고    scopus 로고
    • Excess cardiovascular risk in women relative to men referred for coronary angiography is associated with severely impaired coronary flow reserve, not obstructive disease
    • PID: 27881570
    • Taqueti VR, Shaw LJ, Cook NR, Murthy VL, Shah NR, Foster CR, et al. Excess cardiovascular risk in women relative to men referred for coronary angiography is associated with severely impaired coronary flow reserve, not obstructive disease. Circulation. 2017;135:566–77
    • (2017) Circulation , vol.135 , pp. 566-577
    • Taqueti, V.R.1    Shaw, L.J.2    Cook, N.R.3    Murthy, V.L.4    Shah, N.R.5    Foster, C.R.6
  • 24
    • 84922714308 scopus 로고    scopus 로고
    • Interaction of impaired coronary flow reserve and cardiomyocyte injury on adverse cardiovascular outcomes in patients without overt coronary artery disease
    • PID: 25480813
    • Taqueti VR, Everett BM, Murthy VL, Gaber M, Foster CR, Hainer J, et al. Interaction of impaired coronary flow reserve and cardiomyocyte injury on adverse cardiovascular outcomes in patients without overt coronary artery disease. Circulation. 2015;131:528–35
    • (2015) Circulation , vol.131 , pp. 528-535
    • Taqueti, V.R.1    Everett, B.M.2    Murthy, V.L.3    Gaber, M.4    Foster, C.R.5    Hainer, J.6
  • 25
    • 85061516336 scopus 로고    scopus 로고
    • Coronary flow reserve, body mass index and adverse outcomes in patients without overt ischemic heart disease: Implications for metabolic surgery eligibility
    • 1399 abstract
    • Bajaj NS, Osborne, MT, Gupta, A, Bravo P, Vita T, Christensen T, et al. Coronary flow reserve, body mass index and adverse outcomes in patients without overt ischemic heart disease: Implications for metabolic surgery eligibility. J Am Coll Cardiol. 2017;69(11):1399 abstract
    • (2017) J am Coll Cardiol , vol.69 , Issue.11
    • Bajaj, N.S.1    Osborne, M.T.2    Gupta, A.3    Bravo, P.4    Vita, T.5    Christensen, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.