메뉴 건너뛰기




Volumn 9, Issue 4, 2015, Pages 725-738

Vascular glucose sensor symposium: Continuous glucose monitoring systems (CGMS) for hospitalized and ambulatory patients at risk for hyperglycemia, hypoglycemia, and glycemic variability

Author keywords

Artificial pancreas; Continuous glucose monitor; Continuous glucose monitoring system; Glycemic variability; Hyperglycemia; Hypoglycemia; Vascular glucose sensor

Indexed keywords

AMBULATORY CARE; ARTICLE; ARTIFICIAL PANCREAS; AUTOMATION; BLOOD GLUCOSE METER; BLOOD GLUCOSE MONITORING; CLINICAL OUTCOME; CONTINUOUS GLUCOSE MONITORING SYSTEM; COST; DIABETES MELLITUS; GLUCOSE SENSOR; GLYCEMIC CONTROL; HOSPITAL PATIENT; HUMAN; HYPERGLYCEMIA; HYPOGLYCEMIA; IMPLANTATION; INDWELLING CATHETER; INSULIN TREATMENT; INTRAVASCULAR CATHETER; POINT OF CARE TESTING; RANDOMIZED CONTROLLED TRIAL (TOPIC); RISK ASSESSMENT; SAFETY; STANDARDIZATION; SUBCUTANEOUS TISSUE; ALGORITHM; ANALYSIS; BLOOD; CALIBRATION; CATHETERIZATION; DEVICES; ELECTROCHEMISTRY; EQUIPMENT DESIGN; GLUCOSE BLOOD LEVEL; HOSPITALIZATION; IMPLANTABLE INFUSION PUMP; INSULIN INFUSION; PHYSIOLOGIC MONITORING; POINT OF CARE SYSTEM; PROCEDURES; REPRODUCIBILITY; RISK;

EID: 85018652683     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/1932296815587938     Document Type: Article
Times cited : (11)

References (155)
  • 1
    • 33846678717 scopus 로고    scopus 로고
    • Prevalence of hyper- and hypoglycemia among inpatients with diabetes: A national survey of 44 U.S. Hospitals
    • Wexler DJ, Meigs JB, Cagliero E, Nathan DM, Grant RW. Prevalence of hyper- and hypoglycemia among inpatients with diabetes: a national survey of 44 U.S. hospitals. Diabetes Care. 2007;30:367-369.
    • (2007) Diabetes Care , vol.30 , pp. 367-369
    • Wexler, D.J.1    Meigs, J.B.2    Cagliero, E.3    Nathan, D.M.4    Grant, R.W.5
  • 2
    • 85028558813 scopus 로고    scopus 로고
    • Centers for Disease Control and Prevention. Accessed December 22
    • Centers for Disease Control and Prevention. Surveillance reports: reports: resource library: diabetes. http://www.cdc.gov/diabetes/library/reports/surveillance.html. Accessed December 22, 2014.
    • (2014) Surveillance Reports: Reports: Resource Library: Diabetes
  • 3
    • 0034603545 scopus 로고    scopus 로고
    • Stress hyperglycemia and increased risk of death after myocardial infarction in patients with and without diabetes: A systematic overview
    • Capes S, Hunt D, Malmberg K, Gerstein H. Stress hyperglycemia and increased risk of death after myocardial infarction in patients with and without diabetes: a systematic overview. Lancet. 2000;355(9206):773-778.
    • (2000) Lancet , vol.355 , Issue.9206 , pp. 773-778
    • Capes, S.1    Hunt, D.2    Malmberg, K.3    Gerstein, H.4
  • 4
    • 0031883615 scopus 로고    scopus 로고
    • Early postoperative glucose control predicts nosocomial infection rate in diabetic patients
    • Pomposelli J, Baxter J, Babineau T, et al. Early postoperative glucose control predicts nosocomial infection rate in diabetic patients. J Parenter Enteral Nutr. 1998;22(2):77-81.
    • (1998) J Parenter Enteral Nutr , vol.22 , Issue.2 , pp. 77-81
    • Pomposelli, J.1    Baxter, J.2    Babineau, T.3
  • 5
    • 0036962051 scopus 로고    scopus 로고
    • Hyperglycemia: An independent marker of in-hospital mortality in patients with undiagnosed diabetes
    • Umpierrez G, Isaacs S, Bazargan N, You X, Thaler L, Kitabchi A. Hyperglycemia: an independent marker of in-hospital mortality in patients with undiagnosed diabetes. J Clin Endocrinol Metab. 2002;87:978-982.
    • (2002) J Clin Endocrinol Metab , vol.87 , pp. 978-982
    • Umpierrez, G.1    Isaacs, S.2    Bazargan, N.3    You, X.4    Thaler, L.5    Kitabchi, A.6
  • 6
    • 0345374590 scopus 로고    scopus 로고
    • Association between hyperglycemia and increased hospital mortality in a heterogeneous population of critically ill patients
    • Krinsley JS. Association between hyperglycemia and increased hospital mortality in a heterogeneous population of critically ill patients. Mayo Clin Proc. 2003;78:1471-1478.
    • (2003) Mayo Clin Proc , vol.78 , pp. 1471-1478
    • Krinsley, J.S.1
  • 7
    • 4744343008 scopus 로고    scopus 로고
    • Early post-operative glucose levels are an independent risk factor for infection after peripheral vascular surgery. A retrospective study
    • Vriesendorp TM, Morélis QJ, DeVries JH, Legemate DA, Hoekstra JBL. Early post-operative glucose levels are an independent risk factor for infection after peripheral vascular surgery. A retrospective study. Eur J Vasc Endovasc Surg. 2004;28:520-525.
    • (2004) Eur J Vasc Endovasc Surg , vol.28 , pp. 520-525
    • Vriesendorp, T.M.1    Morélis, Q.J.2    DeVries, J.H.3    Legemate, D.A.4    Hoekstra, J.B.L.5
  • 8
    • 49949090661 scopus 로고    scopus 로고
    • Blood glucose concentration and outcome of critical illness: The impact of diabetes
    • Egi M, Bellomo R, Stachowski E, et al. Blood glucose concentration and outcome of critical illness: the impact of diabetes. Crit Care Med. 2008;36:2249-2255.
    • (2008) Crit Care Med , vol.36 , pp. 2249-2255
    • Egi, M.1    Bellomo, R.2    Stachowski, E.3
  • 9
    • 70649098568 scopus 로고    scopus 로고
    • Hyperglycemia-related mortality in critically ill patients varies with admission diagnosis
    • Falciglia M, Freyberg RW, Almenoff PL, D'Alessio DA, Render ML. Hyperglycemia-related mortality in critically ill patients varies with admission diagnosis. Crit Care Med. 2009;37(12):3001-3009.
    • (2009) Crit Care Med , vol.37 , Issue.12 , pp. 3001-3009
    • Falciglia, M.1    Freyberg, R.W.2    Almenoff, P.L.3    D'Alessio, D.A.4    Render, M.L.5
  • 10
    • 20144370337 scopus 로고    scopus 로고
    • Persistent hyperglycemia is predictive of outcome in critically ill trauma patients
    • Bochicchio G, Sung J, Joshi M, et al. Persistent hyperglycemia is predictive of outcome in critically ill trauma patients. J Trauma. 2005:58(5):921-924.
    • (2005) J Trauma , vol.58 , Issue.5 , pp. 921-924
    • Bochicchio, G.1    Sung, J.2    Joshi, M.3
  • 11
    • 73149125359 scopus 로고    scopus 로고
    • Preadmission hyperglycemia is an independent risk factor for in-hospital symptomatic pulmonary embolism after major orthopedic surgery
    • Mraovic B, Hipszer BR, Epstein RH, Pequignot EC, Parvizi J, Joseph JI. Preadmission hyperglycemia is an independent risk factor for in-hospital symptomatic pulmonary embolism after major orthopedic surgery. J Arthroplasty. 2010;25:64-70.
    • (2010) J Arthroplasty , vol.25 , pp. 64-70
    • Mraovic, B.1    Hipszer, B.R.2    Epstein, R.H.3    Pequignot, E.C.4    Parvizi, J.5    Joseph, J.I.6
  • 12
    • 20544451806 scopus 로고    scopus 로고
    • Admission glucose and mortality in elderly patients hospitalized with acute myocardial infarction implications for patients with and without recognized diabetes
    • Kosiborod M, Rathore SS, Inzucchi SE, et al. Admission glucose and mortality in elderly patients hospitalized with acute myocardial infarction implications for patients with and without recognized diabetes. Circulation. 111;2005:3078-3086.
    • (2005) Circulation , vol.111 , pp. 3078-3086
    • Kosiborod, M.1    Rathore, S.S.2    Inzucchi, S.E.3
  • 13
    • 26244459396 scopus 로고    scopus 로고
    • Poor intraoperative blood glucose control is associated with a worsened hospital outcome after cardiac surgery in diabetic patients
    • Ouattara A, Lecomte P, Le Manach Y, et al. Poor intraoperative blood glucose control is associated with a worsened hospital outcome after cardiac surgery in diabetic patients. Anesthesiology. 2005;103:687-694.
    • (2005) Anesthesiology , vol.103 , pp. 687-694
    • Ouattara, A.1    Lecomte, P.2    Le Manach, Y.3
  • 14
    • 0022902496 scopus 로고
    • Hypoglycemia in hospitalized patients
    • Fischer K, Lees J, Newman J. Hypoglycemia in hospitalized patients. N Engl J Med. 1986;315:1245-1250.
    • (1986) N Engl J Med , vol.315 , pp. 1245-1250
    • Fischer, K.1    Lees, J.2    Newman, J.3
  • 15
    • 33745802207 scopus 로고    scopus 로고
    • Hypoglycaemia: The limiting factor in the glycaemic management of the critically ill?
    • Cryer P. Hypoglycaemia: the limiting factor in the glycaemic management of the critically ill? Diabetologia. 2006;49(8):1722.
    • (2006) Diabetologia , vol.49 , Issue.8 , pp. 1722
    • Cryer, P.1
  • 16
    • 34447506735 scopus 로고    scopus 로고
    • Severe hypoglycemia in critically ill patients: Risk factors and outcomes
    • Krinsley J, Grover A, Severe hypoglycemia in critically ill patients: Risk factors and outcomes. Crit Care Med. 2007:35(10):2262-2267.
    • (2007) Crit Care Med , vol.35 , Issue.10 , pp. 2262-2267
    • Krinsley, J.1    Grover, A.2
  • 17
    • 77649215841 scopus 로고    scopus 로고
    • Hypoglycemia and outcome in critically ill patients
    • Egi M, Bellomo R, Stachowski E, et al. Hypoglycemia and outcome in critically ill patients. Mayo Clin Prox. 2010;85: 217-224
    • (2010) Mayo Clin Prox , vol.85 , pp. 217-224
    • Egi, M.1    Bellomo, R.2    Stachowski, E.3
  • 18
    • 84866433521 scopus 로고    scopus 로고
    • Hypoglycemia and risk of death in critically ill patients
    • Finfer S, Liu B, Chittock DR, et al. Hypoglycemia and risk of death in critically ill patients. N Engl J Med. 2012;367(12): 1108-1118.
    • (2012) N Engl J Med , vol.367 , Issue.12 , pp. 1108-1118
    • Finfer, S.1    Liu, B.2    Chittock, D.R.3
  • 19
    • 33750237099 scopus 로고    scopus 로고
    • Evaluation of short-term consequences of hypoglycemia in an intensive care unit
    • Vriesendorp T, De Vries J, van Santen S, et al. Evaluation of short-term consequences of hypoglycemia in an intensive care unit. Crit Care Med. 2006;34:2714-2718.
    • (2006) Crit Care Med , vol.34 , pp. 2714-2718
    • Vriesendorp, T.1    De Vries, J.2    Van Santen, S.3
  • 20
    • 0043156252 scopus 로고    scopus 로고
    • Hypoglycemia as a predictor of mortality in hospitalized elderly patients
    • Kagansky N, Levy S, Rimon E, et al. Hypoglycemia as a predictor of mortality in hospitalized elderly patients. Arch Int Med. 2003;163:1825-1829.
    • (2003) Arch Int Med , vol.163 , pp. 1825-1829
    • Kagansky, N.1    Levy, S.2    Rimon, E.3
  • 21
    • 34247098471 scopus 로고    scopus 로고
    • Evaluation of short-term consequences of hypoglycemia in an intensive care unit
    • Thomas A, Boxall E, Twamley H. Evaluation of short-term consequences of hypoglycemia in an intensive care unit. Crit Care Med. 2007;35(4):1218-1219.
    • (2007) Crit Care Med , vol.35 , Issue.4 , pp. 1218-1219
    • Thomas, A.1    Boxall, E.2    Twamley, H.3
  • 22
    • 55349134410 scopus 로고    scopus 로고
    • Glycemic variability: A strong independent predictor of mortality in critically ill patients
    • Krinsley J. Glycemic variability: a strong independent predictor of mortality in critically ill patients. Crit Care Med. 2008;36:3008-3013.
    • (2008) Crit Care Med , vol.36 , pp. 3008-3013
    • Krinsley, J.1
  • 23
    • 84874398872 scopus 로고    scopus 로고
    • Diabetic status and the relationship of the 3 domains of glycemic control to mortality in critically ill patients: An international multi-center cohort study
    • Krinsley J, Egi M, Kiss A, et al. Diabetic status and the relationship of the 3 domains of glycemic control to mortality in critically ill patients: an international multi-center cohort study. Crit Care 2013;17:R37.
    • (2013) Crit Care , vol.17 , pp. R37
    • Krinsley, J.1    Egi, M.2    Kiss, A.3
  • 24
    • 33746621650 scopus 로고    scopus 로고
    • Variability of blood glucose concentration and short-term mortality in critically ill patients
    • Egi M, Bellomo R, Stachowski E, French C, Hart G. Variability of blood glucose concentration and short-term mortality in critically ill patients. Anesthesiology. 2006;105:244-252.
    • (2006) Anesthesiology , vol.105 , pp. 244-252
    • Egi, M.1    Bellomo, R.2    Stachowski, E.3    French, C.4    Hart, G.5
  • 25
    • 84876417537 scopus 로고    scopus 로고
    • Glycemic control in the critically ill-3 domains and diabetic status means one size does not fit all!
    • Krinsley JS. Glycemic control in the critically ill-3 domains and diabetic status means one size does not fit all! Crit Care. 2013;17:131.
    • (2013) Crit Care , vol.17 , pp. 131
    • Krinsley, J.S.1
  • 26
    • 0032942994 scopus 로고    scopus 로고
    • Continuous intravenous insulin infusion reduces the incidence of deep sternal wound infection in diabetic patients after cardiac surgical procedures
    • Furnary A, Zerr K, Grunkemeier G, Starr A. Continuous intravenous insulin infusion reduces the incidence of deep sternal wound infection in diabetic patients after cardiac surgical procedures. Ann Thoracic Surg. 1999;67(2):352-360.
    • (1999) Ann Thoracic Surg , vol.67 , Issue.2 , pp. 352-360
    • Furnary, A.1    Zerr, K.2    Grunkemeier, G.3    Starr, A.4
  • 27
    • 0031051886 scopus 로고    scopus 로고
    • Glucose control lowers the risk of wound infection in diabetics after open heart operations
    • Zerr K, Furnary A, Grunkemeier G, Bookin S, Kanhere V, Starr A. Glucose control lowers the risk of wound infection in diabetics after open heart operations. Ann Thorac Surg. 1997;63:356-361.
    • (1997) Ann Thorac Surg , vol.63 , pp. 356-361
    • Zerr, K.1    Furnary, A.2    Grunkemeier, G.3    Bookin, S.4    Kanhere, V.5    Starr, A.6
  • 28
    • 34247546032 scopus 로고    scopus 로고
    • Intensive insulin protocol improves glucose control and is associated with a reduction in intensive care unit mortality
    • Reed CC, Stewart RM, Sherman M, et al. Intensive insulin protocol improves glucose control and is associated with a reduction in intensive care unit mortality. J Am Coll Surg. 2007;204(5):1048-1054.
    • (2007) J Am Coll Surg , vol.204 , Issue.5 , pp. 1048-1054
    • Reed, C.C.1    Stewart, R.M.2    Sherman, M.3
  • 29
    • 0035829852 scopus 로고    scopus 로고
    • Intensive insulin therapy in the critically ill patients
    • Van den Berghe G, Wouters P, Weekers F, et al. Intensive insulin therapy in the critically ill patients. N Engl J Med. 2001;345(19):1359-1367.
    • (2001) N Engl J Med , vol.345 , Issue.19 , pp. 1359-1367
    • Van Den Berghe, G.1    Wouters, P.2    Weekers, F.3
  • 30
    • 63249128249 scopus 로고    scopus 로고
    • Intensive versus conventional glucose control in critically ill patients
    • Finfer S, Chittock D, Su SYS, et al. Intensive versus conventional glucose control in critically ill patients. N Engl J Med. 2009;360:1283-1297.
    • (2009) N Engl J Med , vol.360 , pp. 1283-1297
    • Finfer, S.1    Chittock, D.2    Su, S.Y.S.3
  • 31
    • 32044465949 scopus 로고    scopus 로고
    • Intensive insulin therapy in the medical ICU
    • Van den Berghe G, Wilmer A, Hermans G, et al. Intensive insulin therapy in the medical ICU. N Engl J Med. 2006;354(5): 449-461.
    • (2006) N Engl J Med , vol.354 , Issue.5 , pp. 449-461
    • Van Den Berghe, G.1    Wilmer, A.2    Hermans, G.3
  • 33
    • 0030974812 scopus 로고    scopus 로고
    • Prospective randomised study of intensive insulin treatment on long term survival after acute myocardial infarction in patients with diabetes mellitus
    • Malberg K. Prospective randomised study of intensive insulin treatment on long term survival after acute myocardial infarction in patients with diabetes mellitus. DIGAMI (Diabetes Mellitus, Insulin Glucose Infusion in Acute Myocardial Infarction) Study Group. BMJ. 1997;314:1512-1515.
    • (1997) DIGAMI (Diabetes Mellitus, Insulin Glucose Infusion in Acute Myocardial Infarction) Study Group. BMJ , vol.314 , pp. 1512-1515
    • Malberg, K.1
  • 34
    • 58149241371 scopus 로고    scopus 로고
    • Intensive versus conventional insulin therapy: A randomized controlled trial in medical and surgical critically ill patients
    • Arabi YMM, Dabbagh OCM, Tamim HMM, et al. Intensive versus conventional insulin therapy: a randomized controlled trial in medical and surgical critically ill patients. Crit Care Med. 2008;36:3190-3197.
    • (2008) Crit Care Med , vol.36 , pp. 3190-3197
    • Arabi, Y.M.M.1    Dabbagh, O.C.M.2    Tamim, H.M.M.3
  • 35
    • 38049096093 scopus 로고    scopus 로고
    • Intensive insulin therapy and pentastarch resuscitation in severe sepsis
    • Brunkhorst F. Intensive insulin therapy and pentastarch resuscitation in severe sepsis. N Engl J Med. 2008;358;125-139.
    • (2008) N Engl J Med , vol.358 , pp. 125-139
    • Brunkhorst, F.1
  • 36
    • 33847308759 scopus 로고    scopus 로고
    • Intensive intraoperative insulin therapy versus conventional glucose management during cardiac surgery: A randomized trial
    • Gandhi GY, Nuttall GA, Abel MD, et al. Intensive intraoperative insulin therapy versus conventional glucose management during cardiac surgery: a randomized trial. Ann Intern Med. 2007;146(4):233-243.
    • (2007) Ann Intern Med , vol.146 , Issue.4 , pp. 233-243
    • Gandhi, G.Y.1    Nuttall, G.A.2    Abel, M.D.3
  • 37
    • 72249083789 scopus 로고    scopus 로고
    • A prospective randomized multi-center controlled trial on tight glucose control by intensive insulin therapy in adult intensive care units: The GluControl study
    • Preiser JC, Devos P, Ruiz-Santana S, et al. A prospective randomized multi-center controlled trial on tight glucose control by intensive insulin therapy in adult intensive care units: the GluControl study. Intensive Care Med. 2009;35:1738-1748.
    • (2009) Intensive Care Med , vol.35 , pp. 1738-1748
    • Preiser, J.C.1    Devos, P.2    Ruiz-Santana, S.3
  • 38
    • 58249129654 scopus 로고    scopus 로고
    • The Society of Thoracic Surgeons practice guideline series: Blood glucose management during adult cardiac surgery
    • Lazar HL, McDonnell M, Chipkin SR, et al. The Society of Thoracic Surgeons practice guideline series: blood glucose management during adult cardiac surgery. Ann Thorac Surg. 2009;87(2):663-669.
    • (2009) Ann Thorac Surg , vol.87 , Issue.2 , pp. 663-669
    • Lazar, H.L.1    McDonnell, M.2    Chipkin, S.R.3
  • 39
    • 84870225739 scopus 로고    scopus 로고
    • Guidelines for the use of an insulin infusion for the management of hyperglycemia in critically ill patients
    • Jacobi J, Bircher N, Krinsley J, et al. Guidelines for the use of an insulin infusion for the management of hyperglycemia in critically ill patients. Crit Care Med. 2012;40(12):3251-3276.
    • (2012) Crit Care Med , vol.40 , Issue.12 , pp. 3251-3276
    • Jacobi, J.1    Bircher, N.2    Krinsley, J.3
  • 40
    • 84855512361 scopus 로고    scopus 로고
    • Management of hyperglycemia in hospitalized patients in non-critical care setting: An Endocrine Society clinical practice guideline
    • Umpierrez GE, Hellman R, Korytkowski MT, et al. Management of hyperglycemia in hospitalized patients in non-critical care setting: an Endocrine Society clinical practice guideline. J Clin Endocrinol Metab. 2012;97:16-38.
    • (2012) J Clin Endocrinol Metab , vol.97 , pp. 16-38
    • Umpierrez, G.E.1    Hellman, R.2    Korytkowski, M.T.3
  • 41
    • 66549097705 scopus 로고    scopus 로고
    • American Association of Clinical Endocrinologists and American Diabetes Association consensus statement on inpatient glycemic control
    • Moghissi ES, Korytkowski MT, DiNardo M, et al. American Association of Clinical Endocrinologists and American Diabetes Association consensus statement on inpatient glycemic control. Diabetes Care. 2009;32:1119-1131.
    • (2009) Diabetes Care , vol.32 , pp. 1119-1131
    • Moghissi, E.S.1    Korytkowski, M.T.2    DiNardo, M.3
  • 42
    • 78650309214 scopus 로고    scopus 로고
    • Society for Ambulatory Anesthesia consensus statement on perioperative blood glucose management in diabetic patients undergoing ambulatory surgery
    • Joshi GP, Chung F, Vann MA, et al. Society for Ambulatory Anesthesia consensus statement on perioperative blood glucose management in diabetic patients undergoing ambulatory surgery. Anesth Analg. 2010;111:1378-1387.
    • (2010) Anesth Analg , vol.111 , pp. 1378-1387
    • Joshi, G.P.1    Chung, F.2    Vann, M.A.3
  • 43
    • 84879028957 scopus 로고    scopus 로고
    • Clinical review: Consensus recommendations on measurement of blood glucose and reporting glycemic control in critically ill adults
    • Finfer S, Wernerman J, Preiser JC, et al. Clinical review: consensus recommendations on measurement of blood glucose and reporting glycemic control in critically ill adults. Crit Care. 2013;17:229.
    • (2013) Crit Care , vol.17 , pp. 229
    • Finfer, S.1    Wernerman, J.2    Preiser, J.C.3
  • 44
    • 84866760866 scopus 로고    scopus 로고
    • Glucose in the ICU-evidence, guidelines, and outcomes
    • Kavanagh BP. Glucose in the ICU-evidence, guidelines, and outcomes. N Engl J Med. 2012;367:1259-1260.
    • (2012) N Engl J Med , vol.367 , pp. 1259-1260
    • Kavanagh, B.P.1
  • 45
    • 32044448937 scopus 로고    scopus 로고
    • Intensive insulin in intensive care
    • Malhotra A. Intensive insulin in intensive care. N Engl J Med. 2006;354(5):516-518.
    • (2006) N Engl J Med , vol.354 , Issue.5 , pp. 516-518
    • Malhotra, A.1
  • 46
    • 0842268332 scopus 로고    scopus 로고
    • Management of diabetes and hyperglycemia in hospitals
    • Clement S, Braithwaite S, Magee M, et al. Management of diabetes and hyperglycemia in hospitals. Diabetes Care. 2004:27:553-591.
    • (2004) Diabetes Care , vol.27 , pp. 553-591
    • Clement, S.1    Braithwaite, S.2    Magee, M.3
  • 47
    • 34047098353 scopus 로고    scopus 로고
    • Better glycemic control in the hospital: Beneficial and feasible
    • Clement S. Better glycemic control in the hospital: beneficial and feasible. Cleve Clin J Med. 2007;74(2):111-120.
    • (2007) Cleve Clin J Med , vol.74 , Issue.2 , pp. 111-120
    • Clement, S.1
  • 48
    • 84855518753 scopus 로고    scopus 로고
    • Glycemic control in non-critically ill hospitalized patients: A systematic review and meta-analysis
    • Murad MH, Coburn JA, Coto-Yglesias F, et al. Glycemic control in non-critically ill hospitalized patients: a systematic review and meta-analysis. J Clin Endocrinol Metab. 2012;97:49-58.
    • (2012) J Clin Endocrinol Metab , vol.97 , pp. 49-58
    • Murad, M.H.1    Coburn, J.A.2    Coto-Yglesias, F.3
  • 50
    • 33845257074 scopus 로고    scopus 로고
    • Evaluation of nursing work effort and perceptions about blood glucose testing in tight glycemic control
    • Aragon D. Evaluation of nursing work effort and perceptions about blood glucose testing in tight glycemic control. Am J Crit Care. 2006;15:370-377.
    • (2006) Am J Crit Care , vol.15 , pp. 370-377
    • Aragon, D.1
  • 51
    • 12944326317 scopus 로고    scopus 로고
    • Analysis of blood glucose measurements using capillary and arterial blood samples in intensive care patients
    • Kulkarni A, Saxena M, Price G, O'Leary MJ, Jacques T, Myburgh JA. Analysis of blood glucose measurements using capillary and arterial blood samples in intensive care patients. Intensive Care Med. 2005;31:142-145.
    • (2005) Intensive Care Med , vol.31 , pp. 142-145
    • Kulkarni, A.1    Saxena, M.2    Price, G.3    O'Leary, M.J.4    Jacques, T.5    Myburgh, J.A.6
  • 52
    • 34250620535 scopus 로고    scopus 로고
    • Accuracy of Roche Accu-Chek Inform whole blood capillary, arterial, and venous glucose values in patients receiving intensive intravenous insulin therapy after cardiac surgery
    • Karon BS, Gandhi GY, Nuttall GA, et al. Accuracy of Roche Accu-Chek Inform whole blood capillary, arterial, and venous glucose values in patients receiving intensive intravenous insulin therapy after cardiac surgery. Am J Clin Pathol. 2007;127(6):919-926.
    • (2007) Am J Clin Pathol , vol.127 , Issue.6 , pp. 919-926
    • Karon, B.S.1    Gandhi, G.Y.2    Nuttall, G.A.3
  • 53
    • 77956165984 scopus 로고    scopus 로고
    • Glucose levels in blood simultaneously sampled from the radial artery, vena cava, and fingertip
    • October; San Francisco, CA
    • Flood J, Joseph J, Kim L, McNulty S, Chervoneva I. Glucose levels in blood simultaneously sampled from the radial artery, vena cava, and fingertip. Paper presented at: American Society Anesthesiology; October 2007; San Francisco, CA.
    • (2007) American Society Anesthesiology
    • Flood, J.1    Joseph, J.2    Kim, L.3    McNulty, S.4    Chervoneva, I.5
  • 54
    • 62949105974 scopus 로고    scopus 로고
    • Lack of agreement between arterial and central venous blood glucose measurement in critically ill children
    • Nayak PP, Morris K, Lang H, et al. Lack of agreement between arterial and central venous blood glucose measurement in critically ill children. Intensive Care Med. 2009;35(4):762-763.
    • (2009) Intensive Care Med , vol.35 , Issue.4 , pp. 762-763
    • Nayak, P.P.1    Morris, K.2    Lang, H.3
  • 56
    • 0035034235 scopus 로고    scopus 로고
    • Relationships of glucose concentrations in capillary whole blood, venous whole blood, and venous plasma
    • Kuwa K, Nakayama T, Hoshino T, Tominaga M. Relationships of glucose concentrations in capillary whole blood, venous whole blood, and venous plasma. Clin Chim Acta. 2001;307:187-192.
    • (2001) Clin Chim Acta , vol.307 , pp. 187-192
    • Kuwa, K.1    Nakayama, T.2    Hoshino, T.3    Tominaga, M.4
  • 57
    • 33846681947 scopus 로고    scopus 로고
    • Glucose measurement: Confounding issues in setting targets for inpatient management
    • Dungan K, Chapman J, Braithwaite SS, Buse J. Glucose measurement: confounding issues in setting targets for inpatient management. Diabetes Care. 2007;30(2):403-409.
    • (2007) Diabetes Care , vol.30 , Issue.2 , pp. 403-409
    • Dungan, K.1    Chapman, J.2    Braithwaite, S.S.3    Buse, J.4
  • 58
    • 42149138469 scopus 로고    scopus 로고
    • Critical glucose control: The devil is in the details
    • Fahy BG, Coursin DB. Critical glucose control: the devil is in the details. Mayo Clin Proc. 2008;83(4):394-397.
    • (2008) Mayo Clin Proc , vol.83 , Issue.4 , pp. 394-397
    • Fahy, B.G.1    Coursin, D.B.2
  • 59
    • 19844365140 scopus 로고    scopus 로고
    • Agreement between bedside blood and plasma glucose measurement in the ICU setting
    • Finkielman JD, Oyen LJ, Afessa B. Agreement between bedside blood and plasma glucose measurement in the ICU setting. Chest. 2005;127(5):1749-1751.
    • (2005) Chest , vol.127 , Issue.5 , pp. 1749-1751
    • Finkielman, J.D.1    Oyen, L.J.2    Afessa, B.3
  • 60
    • 43549115256 scopus 로고    scopus 로고
    • Accuracy of glycemic measurements in the critically ill
    • Slater-MacLean L, Cembrowski G, Chin D, et al. Accuracy of glycemic measurements in the critically ill. Diabetes Technol Ther. 2008;10(3):169-177.
    • (2008) Diabetes Technol Ther , vol.10 , Issue.3 , pp. 169-177
    • Slater-MacLean, L.1    Cembrowski, G.2    Chin, D.3
  • 61
    • 42149100490 scopus 로고    scopus 로고
    • Accuracy of bedside glucometry in critically ill patients: Influence of clinical characteristics and perfusion index
    • Desachy A, Vuagnat AC, Ghazali AD, et al. Accuracy of bedside glucometry in critically ill patients: influence of clinical characteristics and perfusion index. Mayo Clin Proc. 2008;83(4):400-405.
    • (2008) Mayo Clin Proc , vol.83 , Issue.4 , pp. 400-405
    • Desachy, A.1    Vuagnat, A.C.2    Ghazali, A.D.3
  • 62
    • 0029196039 scopus 로고
    • Accuracy of fingerstick glucose values in shock patients
    • Sylvain HF, Pokorny ME, English SM, et al. Accuracy of fingerstick glucose values in shock patients. Am J Crit Care. 1995;4(1):44-48.
    • (1995) Am J Crit Care , vol.4 , Issue.1 , pp. 44-48
    • Sylvain, H.F.1    Pokorny, M.E.2    English, S.M.3
  • 64
    • 84902303827 scopus 로고    scopus 로고
    • Continuous glucose control in the ICU: Report of a 2013 round table meeting
    • Wernerman J, Desaive T, Finfer S, et al. Continuous glucose control in the ICU: report of a 2013 round table meeting. Crit Care. 2014;18:226.
    • (2014) Crit Care , vol.18 , pp. 226
    • Wernerman, J.1    Desaive, T.2    Finfer, S.3
  • 66
    • 79551579560 scopus 로고    scopus 로고
    • The need for continuous blood glucose monitoring in the intensive care unit
    • Weiss R, Lazar I. The need for continuous blood glucose monitoring in the intensive care unit. J Diabetes Sci Technol. 2007;1(3):412-414.
    • (2007) J Diabetes Sci Technol , vol.1 , Issue.3 , pp. 412-414
    • Weiss, R.1    Lazar, I.2
  • 67
    • 78650686291 scopus 로고    scopus 로고
    • Continuous glucose monitoring during critical care
    • Inzucchi S, Kosiborod M. Continuous glucose monitoring during critical care. Anesthesiology. 2011;114(1):18-19.
    • (2011) Anesthesiology , vol.114 , Issue.1 , pp. 18-19
    • Inzucchi, S.1    Kosiborod, M.2
  • 68
    • 33847627865 scopus 로고    scopus 로고
    • Thinking like a pancreas: Perioperative glycemic control
    • Martinez E, Williams K, Pronovost P. Thinking like a pancreas: perioperative glycemic control. Anesth Analg. 2007;104(1): 4-6.
    • (2007) Anesth Analg , vol.104 , Issue.1 , pp. 4-6
    • Martinez, E.1    Williams, K.2    Pronovost, P.3
  • 69
    • 34547607218 scopus 로고    scopus 로고
    • Thinking like a pancreas: A look ahead at diabetes technology in the perioperative setting
    • Torjman MC, Goldberg ME, Hirsh RA, Littman J. Thinking like a pancreas: a look ahead at diabetes technology in the perioperative setting. Anesth Analg. 2007;105(2):545.
    • (2007) Anesth Analg , vol.105 , Issue.2 , pp. 545
    • Torjman, M.C.1    Goldberg, M.E.2    Hirsh, R.A.3    Littman, J.4
  • 70
    • 77953040750 scopus 로고    scopus 로고
    • Analysis: Continuous glucose monitoring during intensive insulin therapy
    • Mraovic B. Analysis: continuous glucose monitoring during intensive insulin therapy. J Diabetes Sci Technol. 2009;3(4):960-963.
    • (2009) J Diabetes Sci Technol , vol.3 , Issue.4 , pp. 960-963
    • Mraovic, B.1
  • 71
    • 77649259538 scopus 로고    scopus 로고
    • Real-time continuous glucose monitoring in critically ill patients a prospective randomized trial
    • Holzinger U, Warszawska J, Kitzberger R, et al. Real-time continuous glucose monitoring in critically ill patients a prospective randomized trial. Diabetes Care. 2010;33:467-472.
    • (2010) Diabetes Care , vol.33 , pp. 467-472
    • Holzinger, U.1    Warszawska, J.2    Kitzberger, R.3
  • 72
    • 70449629451 scopus 로고    scopus 로고
    • Continuous glucose monitor shows potential for early hypoglycemia detection in hospitalized patients
    • Ryan M, Savarese V, Hipszer B, et al. Continuous glucose monitor shows potential for early hypoglycemia detection in hospitalized patients. Diabetes Technol Ther. 2009;11(11):745-747.
    • (2009) Diabetes Technol Ther , vol.11 , Issue.11 , pp. 745-747
    • Ryan, M.1    Savarese, V.2    Hipszer, B.3
  • 73
    • 33749077158 scopus 로고    scopus 로고
    • Real-time continuous glucose monitoring in pediatric patients during and after cardiac surgery
    • Piper HG, Alexander JL, Shukla A, et al. Real-time continuous glucose monitoring in pediatric patients during and after cardiac surgery. Pediatrics. 2006;118(3):1176-1184.
    • (2006) Pediatrics , vol.118 , Issue.3 , pp. 1176-1184
    • Piper, H.G.1    Alexander, J.L.2    Shukla, A.3
  • 74
    • 84922532143 scopus 로고    scopus 로고
    • Is glycemic control of the critically ill cost-effective?
    • Krinsley J. Is glycemic control of the critically ill cost-effective? Hosp Pract. 2014;42:4.
    • (2014) Hosp Pract , vol.42 , pp. 4
    • Krinsley, J.1
  • 76
    • 33644589802 scopus 로고    scopus 로고
    • Analysis of healthcare resource utilization with intensive insulin therapy in critically ill patients
    • Van den Berghe G, Wouters P, Kestesteloot K, Hilleman DE, Analysis of healthcare resource utilization with intensive insulin therapy in critically ill patients. Crit Care Med. 2006;34(3):612-616.
    • (2006) Crit Care Med , vol.34 , Issue.3 , pp. 612-616
    • Van Den Berghe, G.1    Wouters, P.2    Kestesteloot, K.3    Hilleman, D.E.4
  • 77
  • 78
    • 33645129570 scopus 로고    scopus 로고
    • Cost analysis of intensive glycemic control in critically ill adult patients
    • Krinsley J, Jones RL. Cost analysis of intensive glycemic control in critically ill adult patients. Chest. 2006;129(3):644-650.
    • (2006) Chest , vol.129 , Issue.3 , pp. 644-650
    • Krinsley, J.1    Jones, R.L.2
  • 79
    • 78349265802 scopus 로고    scopus 로고
    • Continuous glucose monitors and the burden of tight glycemic control in critical care: Can they cure the time cost?
    • Signal M, Pretty CG, Chase JG, Le Compte A, Shaw GM. Continuous glucose monitors and the burden of tight glycemic control in critical care: can they cure the time cost? J Diabetes Sci Technol. 2010;4(3):625-635.
    • (2010) J Diabetes Sci Technol , vol.4 , Issue.3 , pp. 625-635
    • Signal, M.1    Pretty, C.G.2    Chase, J.G.3    Le Compte, A.4    Shaw, G.M.5
  • 80
    • 84907016433 scopus 로고    scopus 로고
    • Insulin treatment guided by subcutaneous continuous glucose monitoring compared to frequent point-of-care measurement in critically ill patients: A randomized controlled trial
    • Boom DT, Sechterberger MK, Rijkenberg S, et al. Insulin treatment guided by subcutaneous continuous glucose monitoring compared to frequent point-of-care measurement in critically ill patients: a randomized controlled trial. Crit Care. 2014;18:453.
    • (2014) Crit Care , vol.18 , pp. 453
    • Boom, D.T.1    Sechterberger, M.K.2    Rijkenberg, S.3
  • 81
    • 84930197839 scopus 로고    scopus 로고
    • Tight glycemic control versus standard care after pediatric cardiac surgery
    • Agus MS, Steil GM, Wypij D, et al. Tight glycemic control versus standard care after pediatric cardiac surgery. N Engl J Med. 2012;367:1208-1219.
    • (2012) N Engl J Med , vol.367 , pp. 1208-1219
    • Agus, M.S.1    Steil, G.M.2    Wypij, D.3
  • 82
    • 17844390680 scopus 로고    scopus 로고
    • The use of two continuous glucose sensors during and after surgery
    • Vriesendorp TM, DeVries JH, Holleman F, et al. The use of two continuous glucose sensors during and after surgery. Diabetes Technol Ther. 2005;7:315-322.
    • (2005) Diabetes Technol Ther , vol.7 , pp. 315-322
    • Vriesendorp, T.M.1    DeVries, J.H.2    Holleman, F.3
  • 83
    • 34250736254 scopus 로고    scopus 로고
    • Glucose control in pediatric intensive care unit patients using an insulinglucose algorithm
    • Wintergerst KA, Deiss D, Buckingham B, et al. Glucose control in pediatric intensive care unit patients using an insulinglucose algorithm. Diabetes Technol Ther. 2007;9(3):211-222.
    • (2007) Diabetes Technol Ther , vol.9 , Issue.3 , pp. 211-222
    • Wintergerst, K.A.1    Deiss, D.2    Buckingham, B.3
  • 84
    • 84874850149 scopus 로고    scopus 로고
    • The use of continuous glucose monitoring combined with computer-based eMPC algorithm for tight glucose control in cardio-surgical ICU
    • Kopeck P, Mráz M, Bláha J, et al. The use of continuous glucose monitoring combined with computer-based eMPC algorithm for tight glucose control in cardio-surgical ICU. BioMed Res Int. 2013:186439. http://dx.doi.org/10.1155/2013/186439.
    • (2013) BioMed Res Int , pp. 186439
    • Kopeck, P.1    Mráz, M.2    Bláha, J.3
  • 85
    • 0035986130 scopus 로고    scopus 로고
    • Closed-loop control of blood glucose levels in critically ill patients
    • Chee F, Fernando T, van Heerden PV. Closed-loop control of blood glucose levels in critically ill patients. Anaesth Intensive Care. 2002;30(3):295-307.
    • (2002) Anaesth Intensive Care , vol.30 , Issue.3 , pp. 295-307
    • Chee, F.1    Fernando, T.2    Van Heerden, P.V.3
  • 86
    • 0037332507 scopus 로고    scopus 로고
    • Closed-loop glucose control in critically-ill patients using continuous glucose monitoring system (CGMS) in real-time
    • Chee F, Fernando T, van Heerden PV. Closed-loop glucose control in critically-ill patients using continuous glucose monitoring system (CGMS) in real-time. IEEE Trans Info Technol Biomed. 2003;7:43-53.
    • (2003) IEEE Trans Info Technol Biomed , vol.7 , pp. 43-53
    • Chee, F.1    Fernando, T.2    Van Heerden, P.V.3
  • 87
    • 17844409621 scopus 로고    scopus 로고
    • Targeted glycemic reduction in critical care using closed-loop control
    • Chase JG, Shaw GM, Lin J, et al. Targeted glycemic reduction in critical care using closed-loop control. Diabetes Technol Ther. 2005;7(2):274-282.
    • (2005) Diabetes Technol Ther , vol.7 , Issue.2 , pp. 274-282
    • Chase, J.G.1    Shaw, G.M.2    Lin, J.3
  • 88
    • 84880349426 scopus 로고    scopus 로고
    • Feasibility of fully automated closed-loop glucose control utilizing continuous subcutaneous glucose measurements in critical illness: A randomized controlled trial
    • Leelarathna L, English SW, Thabit H, et al. Feasibility of fully automated closed-loop glucose control utilizing continuous subcutaneous glucose measurements in critical illness: a randomized controlled trial. Crit Care. 2013;17:R159.
    • (2013) Crit Care , vol.17 , pp. R159
    • Leelarathna, L.1    English, S.W.2    Thabit, H.3
  • 89
    • 58149387772 scopus 로고    scopus 로고
    • Pre- and postoperative accuracy and safety of a real-time continuous glucose monitoring system in cardiac surgical patients: A randomized pilot study
    • Logtenberg S, Kleefstra N, Snellen F, et al. Pre- and postoperative accuracy and safety of a real-time continuous glucose monitoring system in cardiac surgical patients: a randomized pilot study. Diabetes Technol Ther. 2009;11:31-37.
    • (2009) Diabetes Technol Ther , vol.11 , pp. 31-37
    • Logtenberg, S.1    Kleefstra, N.2    Snellen, F.3
  • 90
    • 33746595198 scopus 로고    scopus 로고
    • Intensive insulin therapy in the intensive care unit: Assessment by continuous glucose monitoring
    • De Block C, Manuel-Y-Keenoy B, Van Gaal L, Rogiers P. Intensive insulin therapy in the intensive care unit: assessment by continuous glucose monitoring. Diabetes Care. 2006;29:1750-1756.
    • (2006) Diabetes Care , vol.29 , pp. 1750-1756
    • De Block, C.1    Manuel-Y-Keenoy, B.2    Van Gaal, L.3    Rogiers, P.4
  • 91
    • 79953167996 scopus 로고    scopus 로고
    • Accuracy and reliability of a subcutaneous continuous glucose-monitoring system in critically ill patients
    • Brunner R, Kitzberger R, Miehsler W, Herkner H, Madl C, Holzinger U. Accuracy and reliability of a subcutaneous continuous glucose-monitoring system in critically ill patients. Crit Care Med. 2011;39:659-664.
    • (2011) Crit Care Med , vol.39 , pp. 659-664
    • Brunner, R.1    Kitzberger, R.2    Miehsler, W.3    Herkner, H.4    Madl, C.5    Holzinger, U.6
  • 92
    • 54849418793 scopus 로고    scopus 로고
    • Evaluation of a continuous glucose monitor in an unselected general intensive care population
    • Price GC, Stevenson K, Walsh TS. Evaluation of a continuous glucose monitor in an unselected general intensive care population. Crit Care Resusc. 2008;10(3):209-216.
    • (2008) Crit Care Resusc , vol.10 , Issue.3 , pp. 209-216
    • Price, G.C.1    Stevenson, K.2    Walsh, T.S.3
  • 93
    • 77953062418 scopus 로고    scopus 로고
    • Numerical and clinical accuracy of a continuous glucose monitoring system during intravenous insulin therapy in the surgical and burn intensive care units
    • Rabiee A, Virginia Andreasik RN, Abu-Hamdah R, et al. Numerical and clinical accuracy of a continuous glucose monitoring system during intravenous insulin therapy in the surgical and burn intensive care units. J Diabetes Sci Technol. 2009;3(4):951-959.
    • (2009) J Diabetes Sci Technol , vol.3 , Issue.4 , pp. 951-959
    • Rabiee, A.1    Virginia Andreasik, R.N.2    Abu-Hamdah, R.3
  • 94
    • 3042690667 scopus 로고    scopus 로고
    • Experience with the continuous glucose monitoring system in a medical intensive care unit
    • Goldberg PA, Siegel MD, Russell RR, et al. Experience with the continuous glucose monitoring system in a medical intensive care unit. Diabetes Technol Ther. 2004;6(3):339-347.
    • (2004) Diabetes Technol Ther , vol.6 , Issue.3 , pp. 339-347
    • Goldberg, P.A.1    Siegel, M.D.2    Russell, R.R.3
  • 96
    • 0033036090 scopus 로고    scopus 로고
    • Evaluation of a real-time blood glucose monitor in children with diabetic ketoacidosis
    • Coss-Bu JA, Jefferson LS, Stone-McCord S, et al. Evaluation of a real-time blood glucose monitor in children with diabetic ketoacidosis. Diabetes Res Clin Pract. 1999;44(3):175-181.
    • (1999) Diabetes Res Clin Pract , vol.44 , Issue.3 , pp. 175-181
    • Coss-Bu, J.A.1    Jefferson, L.S.2    Stone-McCord, S.3
  • 97
    • 40449113476 scopus 로고    scopus 로고
    • Prospective detection of hyperglycemia in critically ill children using continuous glucose monitoring
    • Allen HF, Rake A, Roy M, Brenner D, McKiernan CA. Prospective detection of hyperglycemia in critically ill children using continuous glucose monitoring. Pediatr Crit Care Med. 2008;9(2):153-158.
    • (2008) Pediatr Crit Care Med , vol.9 , Issue.2 , pp. 153-158
    • Allen, H.F.1    Rake, A.2    Roy, M.3    Brenner, D.4    McKiernan, C.A.5
  • 98
    • 67650838755 scopus 로고    scopus 로고
    • Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring
    • Holzinger U, Warszawska J, Kitzberger R, et al. Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring. Intensive Care Med. 2009;35:1383-1389.
    • (2009) Intensive Care Med , vol.35 , pp. 1383-1389
    • Holzinger, U.1    Warszawska, J.2    Kitzberger, R.3
  • 99
    • 34447622128 scopus 로고    scopus 로고
    • Accuracy and feasibility of point-of-care and continuous blood glucose analyses in critically ill ICU patients
    • Corstjens AM, Ligtenberg JJM, Van der Horst ICC, et al. Accuracy and feasibility of point-of-care and continuous blood glucose analyses in critically ill ICU patients. Crit Care. 2006;10(5):R135.
    • (2006) Crit Care , vol.10 , Issue.5 , pp. R135
    • Corstjens, A.M.1    Ligtenberg, J.J.M.2    Van Der Horst, I.C.C.3
  • 100
    • 77649259538 scopus 로고    scopus 로고
    • Real-time continuous glucose monitoring in critically ill patients
    • Holzinger U, Warszawska J, Kitzberger R, et al. Real-time continuous glucose monitoring in critically ill patients. Diabetes Care. 2010;33:467-472.
    • (2010) Diabetes Care , vol.33 , pp. 467-472
    • Holzinger, U.1    Warszawska, J.2    Kitzberger, R.3
  • 101
    • 77956165782 scopus 로고    scopus 로고
    • Lag associated with interstitial glucose sensors used in a diabetic surgical patient
    • Hipszer B, Joseph JI. Lag associated with interstitial glucose sensors used in a diabetic surgical patient. Anesthesiology. 2006;105:A584.
    • (2006) Anesthesiology , vol.105 , pp. A584
    • Hipszer, B.1    Joseph, J.I.2
  • 102
    • 84947930389 scopus 로고    scopus 로고
    • Performance of the Medtronic Sentrino continuous glucose management (CGM) system in the cardiac intensive care unit
    • Kosiborod M, Gottlieb RK, Sekella JA, et al. Performance of the Medtronic Sentrino continuous glucose management (CGM) system in the cardiac intensive care unit. BMJ Open Diabetes Care. 2014;2.
    • (2014) BMJ Open Diabetes Care , pp. 2
    • Kosiborod, M.1    Gottlieb, R.K.2    Sekella, J.A.3
  • 103
    • 0842278688 scopus 로고    scopus 로고
    • Intravenous catheter complications in the hand and forearm
    • Kagel E, Rayan G. Intravenous catheter complications in the hand and forearm. J Trauma. 2004;56(1):123-127.
    • (2004) J Trauma , vol.56 , Issue.1 , pp. 123-127
    • Kagel, E.1    Rayan, G.2
  • 105
    • 0003098691 scopus 로고
    • Initial deposition of platelets and fibrin on vascular surfaces in flowing blood
    • Marder VJ, et al, eds. 3rd ed. Philadelphia, PA: J.B. Lippincott
    • Turritto VT, Baumgartner HR. Initial deposition of platelets and fibrin on vascular surfaces in flowing blood. In: Marder VJ, et al, eds. Hemostasis and Thrombosis: Basic Principles and Clinical Practice. 3rd ed. Philadelphia, PA: J.B. Lippincott; 1994:805-822.
    • (1994) Hemostasis and Thrombosis: Basic Principles and Clinical Practice , pp. 805-822
    • Turritto, V.T.1    Baumgartner, H.R.2
  • 106
  • 108
    • 77956146689 scopus 로고    scopus 로고
    • Real-time glucose monitoring in the hospital: Future or now?
    • Joseph JI, Hipszer B. Real-time glucose monitoring in the hospital: future or now? Adv Surg. 2010;44:165-184.
    • (2010) Adv Surg , vol.44 , pp. 165-184
    • Joseph, J.I.1    Hipszer, B.2
  • 109
    • 60349129607 scopus 로고    scopus 로고
    • Evaluation of the VIA blood chemistry monitor for glucose in healthy and diabetic volunteers
    • Ganesh A, Hipszer B, Loomba N, Torjman MC, Joseph J. Evaluation of the VIA blood chemistry monitor for glucose in healthy and diabetic volunteers. J Diabetes Sci Technol. 2008;2(2):182-193.
    • (2008) J Diabetes Sci Technol , vol.2 , Issue.2 , pp. 182-193
    • Ganesh, A.1    Hipszer, B.2    Loomba, N.3    Torjman, M.C.4    Joseph, J.5
  • 110
    • 0032128640 scopus 로고    scopus 로고
    • Evaluation in volunteers of the VIA V-ABG automated bedside blood gas, chemistry, and hematocrit monitor
    • Bailey P, McJames S, Cluff M, Wells D, Orr J, Wenternskow D. Evaluation in volunteers of the VIA V-ABG automated bedside blood gas, chemistry, and hematocrit monitor. J Clin Monit Comput. 1998;14:339-346.
    • (1998) J Clin Monit Comput , vol.14 , pp. 339-346
    • Bailey, P.1    McJames, S.2    Cluff, M.3    Wells, D.4    Orr, J.5    Wenternskow, D.6
  • 111
    • 0030646704 scopus 로고    scopus 로고
    • Development of a biosensor-based, patient-attached blood glucose monitoring system
    • Lucisano JY, Edelman SV, Quinto BD, Wong DK. Development of a biosensor-based, patient-attached blood glucose monitoring system. Proc Am Chem Soc. 1997;76:256.
    • (1997) Proc Am Chem Soc , vol.76 , pp. 256
    • Lucisano, J.Y.1    Edelman, S.V.2    Quinto, B.D.3    Wong, D.K.4
  • 112
    • 84914102607 scopus 로고    scopus 로고
    • Accuracy of a feasibility version of an intravenous continuous glucose monitor in volunteers with diabetes and hospitalized patients
    • Foubert L, Lecomte P, Nobels F, Gulino A, De Decker K. Accuracy of a feasibility version of an intravenous continuous glucose monitor in volunteers with diabetes and hospitalized patients. Diabetes Technol Ther. 2014;16:858-866.
    • (2014) Diabetes Technol Ther , vol.16 , pp. 858-866
    • Foubert, L.1    Lecomte, P.2    Nobels, F.3    Gulino, A.4    De Decker, K.5
  • 113
    • 85028559104 scopus 로고    scopus 로고
    • Performance of an automated blood glucose monitor in the OR-ICU
    • October; New Orleans, LA
    • Joseph J, Hipszer B, Grunwald Z, et al. Performance of an automated blood glucose monitor in the OR-ICU. Paper presented at: American Society of Anesthesiology; October 2009; New Orleans, LA.
    • (2009) American Society of Anesthesiology
    • Joseph, J.1    Hipszer, B.2    Grunwald, Z.3
  • 114
    • 85018937901 scopus 로고    scopus 로고
    • Multicenter observational study of the first-generation intravenous blood glucose monitoring system in hospitalized patients
    • Bochicchio G, Hipszer B, Magee M, et al. Multicenter Observational Study of the First-Generation Intravenous Blood Glucose Monitoring System in Hospitalized Patients. J Diabetes Sci Technol. 2015;9:739-750.
    • (2015) J Diabetes Sci Technol , vol.9 , pp. 739-750
    • Bochicchio, G.1    Hipszer, B.2    Magee, M.3
  • 115
    • 84900544100 scopus 로고    scopus 로고
    • Accuracy of a first-generation intravenous blood glucose monitoring system in subjects with diabetes mellitus: A multicenter study
    • Bailey T, Gulino A, Higgins M, Leach J, Kamath A, Simpson P. Accuracy of a first-generation intravenous blood glucose monitoring system in subjects with diabetes mellitus: a multicenter study. J Diabetes Sci Technol. 2013;7(6):1484-1491.
    • (2013) J Diabetes Sci Technol , vol.7 , Issue.6 , pp. 1484-1491
    • Bailey, T.1    Gulino, A.2    Higgins, M.3    Leach, J.4    Kamath, A.5    Simpson, P.6
  • 116
    • 84899450775 scopus 로고    scopus 로고
    • Accuracy and limitations of continuous glucose monitoring using spectroscopy in critically ill patients
    • Van Hooijdonk R, Winters T, Fischer J, et al. Accuracy and limitations of continuous glucose monitoring using spectroscopy in critically ill patients. Ann Intensive Care. 2014;4:8.
    • (2014) Ann Intensive Care , vol.4 , pp. 8
    • Van Hooijdonk, R.1    Winters, T.2    Fischer, J.3
  • 117
    • 84865121695 scopus 로고    scopus 로고
    • Glucose measurement of intensive care unit patient plasma samples using a fixed-wavelength mid-infrared spectroscopy system
    • Krinsley J, Bochicchio K, Calentine C, Bochicchio G. Glucose measurement of intensive care unit patient plasma samples using a fixed-wavelength mid-infrared spectroscopy system. J Diabetes Sci Technol. 2012;6:294-301.
    • (2012) J Diabetes Sci Technol , vol.6 , pp. 294-301
    • Krinsley, J.1    Bochicchio, K.2    Calentine, C.3    Bochicchio, G.4
  • 118
    • 84655171127 scopus 로고    scopus 로고
    • Automated near- continuous glucose monitoring measured in plasma using mid-infrared spectroscopy
    • Jax T, Heise T, Nosek L, Gable J, Lim G, Calentine C. Automated near- continuous glucose monitoring measured in plasma using mid-infrared spectroscopy. J Diabetes Sci Technol. 2011;5:345-352.
    • (2011) J Diabetes Sci Technol , vol.5 , pp. 345-352
    • Jax, T.1    Heise, T.2    Nosek, L.3    Gable, J.4    Lim, G.5    Calentine, C.6
  • 119
    • 84906043660 scopus 로고    scopus 로고
    • Performance assessment of a glucose control protocol in septic patients with an automated intermittent plasma glucose monitoring device
    • Umbrello M, Salice V, Spanu P, et al. Performance assessment of a glucose control protocol in septic patients with an automated intermittent plasma glucose monitoring device. Clin Nutr. 2014;33:867-871.
    • (2014) Clin Nutr , vol.33 , pp. 867-871
    • Umbrello, M.1    Salice, V.2    Spanu, P.3
  • 120
    • 80051533082 scopus 로고    scopus 로고
    • Automated blood sampling and glucose sensing in critical care settings
    • Kunjan K, Lloyd P. Automated blood sampling and glucose sensing in critical care settings. J Diabetes Sci Technol. 2008;2(2):194-200.
    • (2008) J Diabetes Sci Technol , vol.2 , Issue.2 , pp. 194-200
    • Kunjan, K.1    Lloyd, P.2
  • 121
    • 84882945980 scopus 로고    scopus 로고
    • Evaluation of a continuous blood glucose monitoring system using central venous micro dialysis
    • Schierenbeck F, Franco-Cereceda A, Liska J. Evaluation of a continuous blood glucose monitoring system using central venous micro dialysis. J Diabetes Sci Technol. 2012;6(6):1365-1371.
    • (2012) J Diabetes Sci Technol , vol.6 , Issue.6 , pp. 1365-1371
    • Schierenbeck, F.1    Franco-Cereceda, A.2    Liska, J.3
  • 122
    • 84857396330 scopus 로고    scopus 로고
    • Intravascular microdialysis as a method for measuring glucose and lactate during and after cardiac surgery
    • Moller F, Liska J, Eidhagen F, Franco-Cereceda A. Intravascular microdialysis as a method for measuring glucose and lactate during and after cardiac surgery. J Diabetes Sci Technol. 2011;5(5):1099-1107.
    • (2011) J Diabetes Sci Technol , vol.5 , Issue.5 , pp. 1099-1107
    • Moller, F.1    Liska, J.2    Eidhagen, F.3    Franco-Cereceda, A.4
  • 123
    • 84872190207 scopus 로고    scopus 로고
    • Evaluation of a continuous blood glucose monitoring system using a central venous catheter with an integrated micro dialysis function
    • Schierenbeck F, wall A, Franco-Cereceda A, Liska J. Evaluation of a continuous blood glucose monitoring system using a central venous catheter with an integrated micro dialysis function. Diabetes Technol Ther. 2013;15(1):26-31.
    • (2013) Diabetes Technol Ther , vol.15 , Issue.1 , pp. 26-31
    • Schierenbeck, F.1    Wall, A.2    Franco-Cereceda, A.3    Liska, J.4
  • 124
    • 84899638404 scopus 로고    scopus 로고
    • Introducing intravascular microdialysis for continuous lactate monitoring in patients undergoing cardiac surgery: A prospective observational study
    • Schierenbeck F, Nijsten MWN, Franco-Cereceda A, Liska J. Introducing intravascular microdialysis for continuous lactate monitoring in patients undergoing cardiac surgery: a prospective observational study. Crit Care. 2014;18(2):R56.
    • (2014) Crit Care , vol.18 , Issue.2 , pp. R56
    • Schierenbeck, F.1    Nijsten, M.W.N.2    Franco-Cereceda, A.3    Liska, J.4
  • 125
    • 84905918876 scopus 로고    scopus 로고
    • Evaluation of intravascular microdialysis for continuous blood glucose monitoring in hypoglycemia: An animal model
    • Schierenbeck F, Wallin M, Franco-Cereceda A, Liska J. Evaluation of intravascular microdialysis for continuous blood glucose monitoring in hypoglycemia: an animal model. J Diabetes Sci Technol. 2014;8:839-844.
    • (2014) J Diabetes Sci Technol , vol.8 , pp. 839-844
    • Schierenbeck, F.1    Wallin, M.2    Franco-Cereceda, A.3    Liska, J.4
  • 126
    • 85028536534 scopus 로고    scopus 로고
    • Continuous monitoring of blood glucose using a fiberoptic-based intravascular sensor during postoperative care in the ICU
    • Prasad M, Gopal P, Mannam G. Continuous monitoring of blood glucose using a fiberoptic-based intravascular sensor during postoperative care in the ICU. Crit Care. 2014;18(suppl 1):442.
    • (2014) Crit Care , vol.18 , pp. 442
    • Prasad, M.1    Gopal, P.2    Mannam, G.3
  • 128
    • 85018214743 scopus 로고    scopus 로고
    • Use of an Intravascular Fluorescent Continuous Glucose Sensor in ICU Patients
    • Strasma P, Finfer S, Flower O, et al. Use of an Intravascular Fluorescent Continuous Glucose Sensor in ICU Patients. J Diabetes Sci Technol. 2015;9:762-770.
    • (2015) J Diabetes Sci Technol , vol.9 , pp. 762-770
    • Strasma, P.1    Finfer, S.2    Flower, O.3
  • 129
    • 85028574193 scopus 로고    scopus 로고
    • Use of ultrasound to monitor blood flow and thrombus formation around a radial artery catheter and intravascular glucose sensor in surgical patients
    • March 29-April 2, Las Vegas, NV
    • Machado P, Liu JB, Hipszer B, et al. Use of ultrasound to monitor blood flow and thrombus formation around a radial artery catheter and intravascular glucose sensor in surgical patients, Paper presented at: American Institute of Ultrasound in Medicine; March 29-April 2, 2014; Las Vegas, NV.
    • (2014) American Institute of Ultrasound in Medicine
    • Machado, P.1    Liu, J.B.2    Hipszer, B.3
  • 130
    • 84858765953 scopus 로고    scopus 로고
    • Use of a novel fluorescent glucose sensor in volunteer subjects with type 1 diabetes mellitus
    • Peyser T, Zisser H, Khan U, et al. Use of a novel fluorescent glucose sensor in volunteer subjects with type 1 diabetes mellitus. J Diabetes Sci Technol. 2011;5(3):687-693.
    • (2011) J Diabetes Sci Technol , vol.5 , Issue.3 , pp. 687-693
    • Peyser, T.1    Zisser, H.2    Khan, U.3
  • 131
    • 84880950459 scopus 로고    scopus 로고
    • Use of an intravascular fluorescent continuous glucose sensor in subjects with type 1 diabetes mellitus
    • Romey M, Jovanovič L, Bevier W, Markova K, Strasma P, Zisser H. Use of an intravascular fluorescent continuous glucose sensor in subjects with type 1 diabetes mellitus. J Diabetes Sci Technol. 2012;6(6):1260-1266.
    • (2012) J Diabetes Sci Technol , vol.6 , Issue.6 , pp. 1260-1266
    • Romey, M.1    Jovanovič, L.2    Bevier, W.3    Markova, K.4    Strasma, P.5    Zisser, H.6
  • 132
    • 84908259016 scopus 로고    scopus 로고
    • Continuous intra-arterial blood glucose monitoring using quenched fluorescence sensing: A product development study
    • Flower OJ, Bird S, Macken L, et al. Continuous intra-arterial blood glucose monitoring using quenched fluorescence sensing: a product development study. Crit Care Resusc. 2014;16(1):54-61.
    • (2014) Crit Care Resusc , vol.16 , Issue.1 , pp. 54-61
    • Flower, O.J.1    Bird, S.2    Macken, L.3
  • 134
    • 84893851095 scopus 로고    scopus 로고
    • Blood glucose control using a novel continuous blood glucose monitor and repetitive intravenous insulin boluses: Exploiting natural insulin pulsatility as a principle for a future artificial pancreas
    • Skjaervold N, stling D, Hjelme D, Spigset O, Lyng O, Aadahl P. Blood glucose control using a novel continuous blood glucose monitor and repetitive intravenous insulin boluses: exploiting natural insulin pulsatility as a principle for a future artificial pancreas. Int J Endocrinol. 2013;2013:245152.
    • (2013) Int J Endocrinol , vol.2013 , pp. 245152
    • Skjaervold, N.1    Stling, D.2    Hjelme, D.3    Spigset, O.4    Lyng, O.5    Aadahl, P.6
  • 135
    • 34547386355 scopus 로고
    • A servomechanism for blood sugar control
    • Kadish AH. A servomechanism for blood sugar control. Biomed Sci Instrum. 1963;1:171-176.
    • (1963) Biomed Sci Instrum , vol.1 , pp. 171-176
    • Kadish, A.H.1
  • 136
    • 0007424620 scopus 로고
    • Automation control of blood sugar: A servomechanism for glucose monitoring and control
    • Kadish AH. Automation control of blood sugar: a servomechanism for glucose monitoring and control. Am J Med Electron. 1964;3:82-86.
    • (1964) Am J Med Electron , vol.3 , pp. 82-86
    • Kadish, A.H.1
  • 137
    • 0017338283 scopus 로고
    • The development of Biostator, a glucose controlled insulin infusion system (GCIIS)
    • Clemens AH, Chang PH, Myers RW. The development of Biostator, a glucose controlled insulin infusion system (GCIIS). Horm Metab Res. 1977;7(suppl):23-33.
    • (1977) Horm Metab Res , vol.7 , pp. 23-33
    • Clemens, A.H.1    Chang, P.H.2    Myers, R.W.3
  • 138
    • 0016185358 scopus 로고
    • Clinical control of diabetes by the artificial pancreas
    • Albisser AM, Leibel BS, Ewart TF, et al. Clinical control of diabetes by the artificial pancreas. Diabetes. 1974;23(5): 397-404.
    • (1974) Diabetes , vol.23 , Issue.5 , pp. 397-404
    • Albisser, A.M.1    Leibel, B.S.2    Ewart, T.F.3
  • 139
    • 37549019316 scopus 로고    scopus 로고
    • The accuracy of a continuous blood glucose monitor during surgery
    • Yamashita K, Okabayashi T, Yokoyama T, et al. The accuracy of a continuous blood glucose monitor during surgery. Anesth Analg. 2008;106(1):160-163.
    • (2008) Anesth Analg , vol.106 , Issue.1 , pp. 160-163
    • Yamashita, K.1    Okabayashi, T.2    Yokoyama, T.3
  • 140
    • 57649217580 scopus 로고    scopus 로고
    • Accuracy and reliability of continuous blood glucose monitor in postsurgical patients
    • Yamashita K, Okabayashi T, Yokoyama T, et al. Accuracy and reliability of continuous blood glucose monitor in postsurgical patients. Acta Anaesthesiol Scand. 2009;53(1):66-71.
    • (2009) Acta Anaesthesiol Scand , vol.53 , Issue.1 , pp. 66-71
    • Yamashita, K.1    Okabayashi, T.2    Yokoyama, T.3
  • 141
    • 0018727030 scopus 로고
    • Postoperative blood-sugar regulation in pancreatectomized patients using the artificial "beta cell"
    • Ozyol MB, Herfarth C, Kerner W, Pfeiffer EF. Postoperative blood-sugar regulation in pancreatectomized patients using the artificial "beta cell." Chirurg. 1979;50(4):227-232.
    • (1979) Chirurg , vol.50 , Issue.4 , pp. 227-232
    • Ozyol, M.B.1    Herfarth, C.2    Kerner, W.3    Pfeiffer, E.F.4
  • 142
    • 0031756207 scopus 로고    scopus 로고
    • Experience with the Biostator for diagnosis and assisted surgery of 21 insulinomas
    • Gin H, Catargi B, Rigalleau V, Rullier E, Roger P, Tabarin A. Experience with the Biostator for diagnosis and assisted surgery of 21 insulinomas. Eur J Endocrinol. 1998;139(4):371-377.
    • (1998) Eur J Endocrinol , vol.139 , Issue.4 , pp. 371-377
    • Gin, H.1    Catargi, B.2    Rigalleau, V.3    Rullier, E.4    Roger, P.5    Tabarin, A.6
  • 143
    • 41949121806 scopus 로고    scopus 로고
    • Continuous post-operative blood glucose monitoring and control using a closed-loop system in patients undergoing hepatic resection
    • Okabayashi T, Hnazaki K, Nishimori I, et al. Continuous post-operative blood glucose monitoring and control using a closed-loop system in patients undergoing hepatic resection. Dig Dis Sci. 2008;53(5):1405-1410.
    • (2008) Dig Dis Sci , vol.53 , Issue.5 , pp. 1405-1410
    • Okabayashi, T.1    Hnazaki, K.2    Nishimori, I.3
  • 144
    • 79955917624 scopus 로고    scopus 로고
    • Preliminary study on glucose control with an artificial pancreas in postoperative sepsis patients
    • Takahashi G, Sato N, Matsumoto N, et al. Preliminary study on glucose control with an artificial pancreas in postoperative sepsis patients. Eur Surg Res. 2011;47:32-38.
    • (2011) Eur Surg Res , vol.47 , pp. 32-38
    • Takahashi, G.1    Sato, N.2    Matsumoto, N.3
  • 145
    • 70449722983 scopus 로고    scopus 로고
    • Perioperative intensive insulin therapy using artificial endocrine pancreas in patients undergoing pancreatectomy
    • Maeda H, Okabayashi T, Yatabe T, Yamashita K, Hanazaki K. Perioperative intensive insulin therapy using artificial endocrine pancreas in patients undergoing pancreatectomy. World J Gastroenterol. 2009;15(33):4111-4115.
    • (2009) World J Gastroenterol , vol.15 , Issue.33 , pp. 4111-4115
    • Maeda, H.1    Okabayashi, T.2    Yatabe, T.3    Yamashita, K.4    Hanazaki, K.5
  • 147
    • 85018230750 scopus 로고    scopus 로고
    • Fully implantable arterial blood glucose device for metabolic research applications in rats for two months
    • Brockway R, Tiesma S, Bogie H, et al. Fully Implantable Arterial Blood Glucose Device for Metabolic Research Applications in Rats for Two Months. J Diabetes Sci Technol. 2015; 9:771-781.
    • (2015) J Diabetes Sci Technol , vol.9 , pp. 771-781
    • Brockway, R.1    Tiesma, S.2    Bogie, H.3
  • 149
    • 0025689061 scopus 로고
    • Application of chronic intravascular blood glucose sensor in dogs
    • Armour JC, Lucisano JY, McKean BD, Gough DA. Application of chronic intravascular blood glucose sensor in dogs. Diabetes. 1990;39(12):1519-1526.
    • (1990) Diabetes , vol.39 , Issue.12 , pp. 1519-1526
    • Armour, J.C.1    Lucisano, J.Y.2    McKean, B.D.3    Gough, D.A.4
  • 150
    • 33751506973 scopus 로고    scopus 로고
    • Artificial betacell: Clinical experience toward an implantable closed-loop insulin delivery system
    • Renard E, Costalat G, Chevassus H, Bringer J. Artificial betacell: clinical experience toward an implantable closed-loop insulin delivery system. Diabetes Metab. 2006;32:497-502.
    • (2006) Diabetes Metab , vol.32 , pp. 497-502
    • Renard, E.1    Costalat, G.2    Chevassus, H.3    Bringer, J.4
  • 151
    • 33751506973 scopus 로고    scopus 로고
    • Artificial beta cell: Clinical experience toward an implantable closedloop insulin delivery system
    • Renard E, Costalat G, Chevassus H, Bringer J. Artificial beta cell: clinical experience toward an implantable closedloop insulin delivery system. Diabetes Metab. 2006;32(5 pt 2):497-502.
    • (2006) Diabetes Metab , vol.32 , Issue.5 , pp. 497-502
    • Renard, E.1    Costalat, G.2    Chevassus, H.3    Bringer, J.4
  • 152
    • 85028569660 scopus 로고    scopus 로고
    • Development of an implantable NIR spectroscopic blood glucose sensor: Invivo results in dogs
    • June; San Diego, CA
    • Crothall K, Joseph J, Torjman M, et al. Development of an implantable NIR spectroscopic blood glucose sensor: invivo results in dogs. Paper presented at: American Diabetes Association; June 1999; San Diego, CA.
    • (1999) American Diabetes Association
    • Crothall, K.1    Joseph, J.2    Torjman, M.3
  • 155
    • 0141678347 scopus 로고    scopus 로고
    • Laser diode applications in a continuous blood glucose sensor
    • Yu Y, Crothal K, Jahn L, DeStefano M. Laser diode applications in a continuous blood glucose sensor. Proc SPIE. 2003;4996:268-274.
    • (2003) Proc SPIE , vol.4996 , pp. 268-274
    • Yu, Y.1    Crothal, K.2    Jahn, L.3    DeStefano, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.