메뉴 건너뛰기




Volumn 7, Issue 2, 2005, Pages 315-322

The use of two continuous glucose sensors during and after surgery

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL SURGERY; ACCURACY; ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; FEASIBILITY STUDY; FEMALE; GLUCOSE BLOOD LEVEL; HUMAN; INTRAOPERATIVE PERIOD; LEG; MALE; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RELIABILITY; SENSOR; SHOULDER; SURGICAL TECHNIQUE;

EID: 17844390680     PISSN: 15209156     EISSN: None     Source Type: Journal    
DOI: 10.1089/dia.2005.7.315     Document Type: Article
Times cited : (62)

References (11)
  • 4
    • 3543006509 scopus 로고    scopus 로고
    • Microdialysis of glucose in subcutaneous adipose tissue up to 3 weeks in healthy volunteers
    • Wientjes KJ, Vonk P, Vonk-van Klei Y, Schoonen AJ, Kossen NW: Microdialysis of glucose in subcutaneous adipose tissue up to 3 weeks in healthy volunteers. Diabetes Care 1998;21:1481-1488.
    • (1998) Diabetes Care , vol.21 , pp. 1481-1488
    • Wientjes, K.J.1    Vonk, P.2    Vonk-van Klei, Y.3    Schoonen, A.J.4    Kossen, N.W.5
  • 6
    • 0033760311 scopus 로고    scopus 로고
    • Evaluating clinical accuracy of systems for self-monitoring of blood glucose by error grid analysis: Comment on constructing the "upper A-line"
    • Stockl D, Dewitte K, Fierens C, Thienpont LM: Evaluating clinical accuracy of systems for self-monitoring of blood glucose by error grid analysis: Comment on constructing the "upper A-line." Diabetes Care 2000;23:1711-1712.
    • (2000) Diabetes Care , vol.23 , pp. 1711-1712
    • Stockl, D.1    Dewitte, K.2    Fierens, C.3    Thienpont, L.M.4
  • 8
    • 1542439960 scopus 로고    scopus 로고
    • Performance assessment of the Medtronic-MiniMed Continuous Glucose Monitoring System and its use for measurement of glycaemic control in Type 1 diabetic subjects
    • Sachedina N, Pickup JC: Performance assessment of the Medtronic-MiniMed Continuous Glucose Monitoring System and its use for measurement of glycaemic control in Type 1 diabetic subjects. Diabet Med 2003;20:1012-1015.
    • (2003) Diabet Med , vol.20 , pp. 1012-1015
    • Sachedina, N.1    Pickup, J.C.2
  • 9
    • 0036728499 scopus 로고    scopus 로고
    • Spurious reporting of nocturnal hypoglycemia by CGMS in patients with tightly controlled type 1 diabetes
    • McGowan K, Thomas W, Moran A: Spurious reporting of nocturnal hypoglycemia by CGMS in patients with tightly controlled type 1 diabetes. Diabetes Care 2002;25:1499-1503.
    • (2002) Diabetes Care , vol.25 , pp. 1499-1503
    • McGowan, K.1    Thomas, W.2    Moran, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.