메뉴 건너뛰기




Volumn 9, Issue 4, 2015, Pages 762-770

Use of an intravascular fluorescent continuous glucose sensor in ICU patients

Author keywords

Continuous glucose monitoring; Hospital; Intensive care; Intravascular

Indexed keywords

AGED; ARTERY CATHETER; ARTERY THROMBOSIS; ARTICLE; COHORT ANALYSIS; DEVICE FAILURE; DEVICE SAFETY; DIABETES MELLITUS; ECHOGRAPHY; EQUIPMENT DESIGN; FEMALE; GLUCOSE BLOOD LEVEL; GLUCOSE SENSOR; HUMAN; HYPERGLYCEMIA; HYPOGLYCEMIA; INTENSIVE CARE; INTENSIVE CARE UNIT; INTRAVASCULAR CONTINUOUS GLUCOSE MONITORING SYSTEM; INTRAVENOUS CATHETER; ISCHEMIA; MAJOR CLINICAL STUDY; MALE; MEASUREMENT ACCURACY; MEASUREMENT ERROR; REFERENCE VALUE; RELIABILITY; THROMBUS; VEIN EMBOLISM; VEIN OCCLUSION; ANALYSIS; BLOOD; CLINICAL TRIAL; DEVICES; DIAGNOSTIC IMAGING; HEART SURGERY; INSULIN INFUSION; INTRAVENOUS DRUG ADMINISTRATION; MIDDLE AGED; MULTICENTER STUDY; PHYSIOLOGIC MONITORING; POSTOPERATIVE PERIOD; PROCEDURES; THROMBOSIS;

EID: 85018214743     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/1932296815585872     Document Type: Article
Times cited : (21)

References (18)
  • 1
    • 70649098568 scopus 로고    scopus 로고
    • Hyperglycemia-related mortality in critically ill patients varies with admission diagnosis
    • Falciglia M, Freyberg RW, Almenoff PL, D'Alessio DA, Render ML. Hyperglycemia-related mortality in critically ill patients varies with admission diagnosis. Crit Care Med. 2009;37(12):3001-3009.
    • (2009) Crit Care Med , vol.37 , Issue.12 , pp. 3001-3009
    • Falciglia, M.1    Freyberg, R.W.2    Almenoff, P.L.3    D'Alessio, D.A.4    Render, M.L.5
  • 2
    • 58249129654 scopus 로고    scopus 로고
    • The Society of Thoracic Surgeons practice guideline series: Blood glucose management during adult cardiac surgery
    • Lazar HL, McDonnell M, Chipkin SR, et al. The Society of Thoracic Surgeons practice guideline series: blood glucose management during adult cardiac surgery. Ann Thorac Surg. 2009;87(2):663-669.
    • (2009) Ann Thorac Surg , vol.87 , Issue.2 , pp. 663-669
    • Lazar, H.L.1    McDonnell, M.2    Chipkin, S.R.3
  • 3
    • 84870225739 scopus 로고    scopus 로고
    • Guidelines for the use of an insulin infusion for the management of hyperglycemia in critically ill patients
    • Jacobi J, Bircher N, Krinsley J, et al. Guidelines for the use of an insulin infusion for the management of hyperglycemia in critically ill patients. Crit Care Med. 2012;40(12):3251-3276.
    • (2012) Crit Care Med , vol.40 , Issue.12 , pp. 3251-3276
    • Jacobi, J.1    Bircher, N.2    Krinsley, J.3
  • 4
    • 84866433521 scopus 로고    scopus 로고
    • Hypoglycemia and risk of death in critically ill patients
    • Finfer S, Liu B, Chittock DR, et al. Hypoglycemia and risk of death in critically ill patients. N Engl J Med. 2012;367(12): 1108-1118.
    • (2012) N Engl J Med , vol.367 , Issue.12 , pp. 1108-1118
    • Finfer, S.1    Liu, B.2    Chittock, D.R.3
  • 5
    • 77953081942 scopus 로고    scopus 로고
    • Hypoglycemia is associated with intensive care unit mortality
    • Hermanides J, Bosman RJ, Vriesendorp TM, et al. Hypoglycemia is associated with intensive care unit mortality. Crit Care Med. 2010;38(6):1430-1434.
    • (2010) Crit Care Med , vol.38 , Issue.6 , pp. 1430-1434
    • Hermanides, J.1    Bosman, R.J.2    Vriesendorp, T.M.3
  • 7
    • 84858765953 scopus 로고    scopus 로고
    • Use of a novel fluorescent glucose sensor in volunteer subjects with type 1 diabetes mellitus
    • Peyser T, Zisser H, Khan U, et al. Use of a novel fluorescent glucose sensor in volunteer subjects with type 1 diabetes mellitus. J Diabetes Sci Technol. 2011;5(3):687-693.
    • (2011) J Diabetes Sci Technol , vol.5 , Issue.3 , pp. 687-693
    • Peyser, T.1    Zisser, H.2    Khan, U.3
  • 8
    • 84880950459 scopus 로고    scopus 로고
    • Use of an intravascular fluorescent continuous glucose sensor in subjects with type 1 diabetes mellitus
    • Romey M, Jovanovič L, Bevier W, Markova K, Strasma P, Zisser H. Use of an intravascular fluorescent continuous glucose sensor in subjects with type 1 diabetes mellitus. J Diabetes Sci Technol. 2012;6(6):1260-1266.
    • (2012) J Diabetes Sci Technol , vol.6 , Issue.6 , pp. 1260-1266
    • Romey, M.1    Jovanovič, L.2    Bevier, W.3    Markova, K.4    Strasma, P.5    Zisser, H.6
  • 9
    • 84908259016 scopus 로고    scopus 로고
    • Continuous intra-arterial blood glucose monitoring using quenched fluorescence sensing: A product development study
    • Flower OJ, Bird S, Macken L, et al. Continuous intra-arterial blood glucose monitoring using quenched fluorescence sensing: a product development study. Crit Care Med. 2014;16(1): 54-61.
    • (2014) Crit Care Med , vol.16 , Issue.1 , pp. 54-61
    • Flower, O.J.1    Bird, S.2    Macken, L.3
  • 10
    • 84947938892 scopus 로고    scopus 로고
    • Accuracy of intra-arterial and subcutaneous continuous glucose monitoring in postoperative cardiac surgery patients in the ICU
    • Sechterberger MK, van der Voort PHJ, Strasma PJ, DeVries JH. Accuracy of intra-arterial and subcutaneous continuous glucose monitoring in postoperative cardiac surgery patients in the ICU. J Diabetes Sci Technol. 2015; 9(3): 663-667.
    • (2015) J Diabetes Sci Technol , vol.9 , Issue.3 , pp. 663-667
    • Sechterberger, M.K.1    Van Der Voort, P.H.J.2    Strasma, P.J.3    DeVries, J.H.4
  • 11
    • 33846850341 scopus 로고    scopus 로고
    • Boronic acidbased bipyridinium salts as tunable receptors for monosaccharides and alpha-hydroxycarboxylates
    • Gamsey S, Miller A, Olmstead MM, et al. Boronic acidbased bipyridinium salts as tunable receptors for monosaccharides and alpha-hydroxycarboxylates. J Am Chem Soc. 2007;129(5):1278-1286.
    • (2007) J Am Chem Soc , vol.129 , Issue.5 , pp. 1278-1286
    • Gamsey, S.1    Miller, A.2    Olmstead, M.M.3
  • 14
    • 84902303827 scopus 로고    scopus 로고
    • Continuous glucose control in the ICU: Report of a 2013 round table meeting
    • Wernerman J, Desaive T, Finfer S, et al. Continuous glucose control in the ICU: report of a 2013 round table meeting. Crit Care. 2014;18(3):226.
    • (2014) Crit Care , vol.18 , Issue.3 , pp. 226
    • Wernerman, J.1    Desaive, T.2    Finfer, S.3
  • 15
    • 0034526842 scopus 로고    scopus 로고
    • [Problems in clinical use of intraarterial blood gas monitoring system, Paratrend 7]
    • Gamo M, Hirose Y, Matsuo K. [Problems in clinical use of intraarterial blood gas monitoring system, Paratrend 7]. Masui. 2000;49(12):1387-1390.
    • (2000) Masui , vol.49 , Issue.12 , pp. 1387-1390
    • Gamo, M.1    Hirose, Y.2    Matsuo, K.3
  • 16
    • 0035128732 scopus 로고    scopus 로고
    • The role of preoperative radial artery ultrasound and digital plethysmography prior to coronary artery bypass grafting
    • Rodriguez E, Ormont ML, Lambert EH, et al. The role of preoperative radial artery ultrasound and digital plethysmography prior to coronary artery bypass grafting. Eur J Cardio-Thorac Surg. 2001;19(2):135-139.
    • (2001) Eur J Cardio-Thorac Surg , vol.19 , Issue.2 , pp. 135-139
    • Rodriguez, E.1    Ormont, M.L.2    Lambert, E.H.3
  • 17
    • 0036087258 scopus 로고    scopus 로고
    • Clinical review: Complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine
    • Scheer B, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care. 2002;6(3):199-204.
    • (2002) Crit Care , vol.6 , Issue.3 , pp. 199-204
    • Scheer, B.1    Perel, A.2    Pfeiffer, U.J.3
  • 18
    • 77957844083 scopus 로고    scopus 로고
    • Risk of symptomatic DVT associated with peripherally inserted central catheters
    • Evans RS, Sharp JH, Linford LH, et al. Risk of symptomatic DVT associated with peripherally inserted central catheters. Chest. 2010;138(4):803-810.
    • (2010) Chest , vol.138 , Issue.4 , pp. 803-810
    • Evans, R.S.1    Sharp, J.H.2    Linford, L.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.