Volumn 39, Issue , 2017, Pages 57-65

An active simulator for neonatal intubation: Design, development and assessment

Author keywords

Clinical training; Force sensing; Medical simulation; Neonatal intubation; Pressure mapping

Indexed keywords

ARCHES; SILICONES;

EID: 85005978384     PISSN: 13504533     EISSN: 18734030     Source Type: Journal    
DOI: 10.1016/j.medengphy.2016.10.008     Document Type: Article
Times cited : (8)

References (44)
  • 1
    • 84882326827 scopus 로고    scopus 로고
    • Indications for tracheal intubation
    • 2nd ed. Mosby-Elsevier Publisher Philadelphia
    • [1] Ezri, T., Warters, R.D., Indications for tracheal intubation. Benumof's airway management: principles and practice, 2nd ed., 2007, Mosby-Elsevier Publisher, Philadelphia, 371–382.
    • (2007) Benumof's airway management: principles and practice , pp. 371-382
    • Ezri, T.1    Warters, R.D.2
  • 2
    • 53149145796 scopus 로고    scopus 로고
    • Textbook of neonatal resuscitation
    • 6th ed. American Academy of Pediatrics Ed.
    • [2] Kattwinkel, J., Textbook of neonatal resuscitation. 6th ed., 2011, American Academy of Pediatrics Ed., 367.
    • (2011) , pp. 367
    • Kattwinkel, J.1
  • 3
  • 4
    • 85006242846 scopus 로고    scopus 로고
    • Intubation and tracheal suctioning for meconium aspiration
    • emedicine.medscapearticle1413467-overview
    • [4] Sawyer, T.L., Rosenkrantz, T., Intubation and tracheal suctioning for meconium aspiration. 2013 emedicine.medscapearticle1413467-overview.
    • (2013)
    • Sawyer, T.L.1    Rosenkrantz, T.2
  • 6
    • 80051809306 scopus 로고    scopus 로고
    • Automatic endotracheal tube position confirmation system based on image classification—a preliminary assessment
    • [6] Lederman, D., Lampotang, S., Shamir, M.Y., Automatic endotracheal tube position confirmation system based on image classification—a preliminary assessment. Med Eng Phys 33:8 (2011), 1017–1026.
    • (2011) Med Eng Phys , vol.33 , Issue.8 , pp. 1017-1026
    • Lederman, D.1    Lampotang, S.2    Shamir, M.Y.3
  • 7
    • 58849106056 scopus 로고    scopus 로고
    • The difficult pediatric airway
    • 2nd ed. Mosby-Elsevier Publisher Philadelphia
    • [7] Rabb, M.F., Szmuk, P., The difficult pediatric airway. Benumof's airway management: principles and practice, 2nd ed., 2007, Mosby-Elsevier Publisher, Philadelphia, 783–833.
    • (2007) Benumof's airway management: principles and practice , pp. 783-833
    • Rabb, M.F.1    Szmuk, P.2
  • 8
    • 79952756212 scopus 로고    scopus 로고
    • Neonatal Resuscitation Program (NRP) 2011. New science, new strategies
    • [8] Zaichkin, J., Weiner, G.M., Neonatal Resuscitation Program (NRP) 2011. New science, new strategies. Adv Neonatal Care 11:1 (2011), 43–51.
    • (2011) Adv Neonatal Care , vol.11 , Issue.1 , pp. 43-51
    • Zaichkin, J.1    Weiner, G.M.2
  • 10
    • 79953063015 scopus 로고    scopus 로고
    • Using simulation to enhance the acquisition and retention of clinical skills in neonatology
    • [10] Anderson, J.M., Warren, J.B., Using simulation to enhance the acquisition and retention of clinical skills in neonatology. Semin Perinatol 35:2 (2011), 59–67.
    • (2011) Semin Perinatol , vol.35 , Issue.2 , pp. 59-67
    • Anderson, J.M.1    Warren, J.B.2
  • 11
    • 70049091174 scopus 로고    scopus 로고
    • The utility of simulation in medical education: what is the evidence?
    • [11] Okuda, Y., Bryson, E.O., DeMaria, S.Jr, Jacobson, L., Quinones, J., Shen, B., et al. The utility of simulation in medical education: what is the evidence?. Mt Sinai J Med 76:4 (2009), 330–343.
    • (2009) Mt Sinai J Med , vol.76 , Issue.4 , pp. 330-343
    • Okuda, Y.1    Bryson, E.O.2    DeMaria, S.J.3    Jacobson, L.4    Quinones, J.5    Shen, B.6
  • 12
    • 6344223255 scopus 로고    scopus 로고
    • The future vision of simulation in health care
    • [12] Gaba, D.M., The future vision of simulation in health care. Qual Saf Health Care 13:1 (2004), i2–i10.
    • (2004) Qual Saf Health Care , vol.13 , Issue.1 , pp. i2-i10
    • Gaba, D.M.1
  • 13
    • 77955249563 scopus 로고    scopus 로고
    • An intrauterine pressure generator for educational simulation of labour and delivery
    • [13] Bastos, L.F., Lobo, M.F., van Meurs, W.L., Ayres-de-Campos, D., An intrauterine pressure generator for educational simulation of labour and delivery. Med Eng Phys 32:7 (2010), 740–745.
    • (2010) Med Eng Phys , vol.32 , Issue.7 , pp. 740-745
    • Bastos, L.F.1    Lobo, M.F.2    van Meurs, W.L.3    Ayres-de-Campos, D.4
  • 14
    • 37349048535 scopus 로고    scopus 로고
    • Simulation technology for skills training and competency assessment in medical education
    • [14] Scalese, R.J., Obeso, V.T., Issenberg, S.B., Simulation technology for skills training and competency assessment in medical education. J Gen Intern Med 23:1 (2008), 6–9.
    • (2008) J Gen Intern Med , vol.23 , Issue.1 , pp. 6-9
    • Scalese, R.J.1    Obeso, V.T.2    Issenberg, S.B.3
  • 15
    • 58749092368 scopus 로고    scopus 로고
    • A brief history of the development of mannequin simulators for clinical education and training
    • [15] Cooper, J.B., Taqueti, V.R., A brief history of the development of mannequin simulators for clinical education and training. Postgrad Med J 84:997 (2008), 563–570.
    • (2008) Postgrad Med J , vol.84 , Issue.997 , pp. 563-570
    • Cooper, J.B.1    Taqueti, V.R.2
  • 16
    • 84901839656 scopus 로고    scopus 로고
    • How ABBA may help improve neonatal resuscitation training: auditory prompts to enable coordination of manual inflations and chest compressions
    • [16] Roehr, C.C., Schmölzer, G.M., Thio, M., Dawson, J.A., Dold, S.K., Schmalisch, G., et al. How ABBA may help improve neonatal resuscitation training: auditory prompts to enable coordination of manual inflations and chest compressions. J Paediatr Child Health 50 (2014), 444–448.
    • (2014) J Paediatr Child Health , vol.50 , pp. 444-448
    • Roehr, C.C.1    Schmölzer, G.M.2    Thio, M.3    Dawson, J.A.4    Dold, S.K.5    Schmalisch, G.6
  • 19
    • 84862217040 scopus 로고    scopus 로고
    • Parametrically adjustable intubation mannequin with real-time visual feedback
    • [19] Delson, N., Sloan, C., McGee, T., Kedarisetty, S., Yim, W.W., Hastings, R.H., Parametrically adjustable intubation mannequin with real-time visual feedback. Simul Healthcare 7:3 (2012), 183–191.
    • (2012) Simul Healthcare , vol.7 , Issue.3 , pp. 183-191
    • Delson, N.1    Sloan, C.2    McGee, T.3    Kedarisetty, S.4    Yim, W.W.5    Hastings, R.H.6
  • 20
    • 84055197929 scopus 로고    scopus 로고
    • Force and pressure distribution using Macintosh and GlideScope laryngoscopes in normal and difficult airways: a manikin study
    • [20] Carassiti, M., Zanzonico, R., Cecchini, S., Silvestri, S., Cataldo, R., Agrò, F.E., Force and pressure distribution using Macintosh and GlideScope laryngoscopes in normal and difficult airways: a manikin study. Br J Anaesth 108:1 (2012), 146–151.
    • (2012) Br J Anaesth , vol.108 , Issue.1 , pp. 146-151
    • Carassiti, M.1    Zanzonico, R.2    Cecchini, S.3    Silvestri, S.4    Cataldo, R.5    Agrò, F.E.6
  • 22
    • 0026513703 scopus 로고
    • Force applied during tracheal intubation
    • [22] Bishop, M.J., Harrington, R.M., Tencer, A.F., Force applied during tracheal intubation. Anesth Analgesia 74:3 (1992), 411–414.
    • (1992) Anesth Analgesia , vol.74 , Issue.3 , pp. 411-414
    • Bishop, M.J.1    Harrington, R.M.2    Tencer, A.F.3
  • 23
    • 84924612452 scopus 로고    scopus 로고
    • Compression force on the upper jaw during neonatal intubation: Mannequin study
    • [23] Doreswamy, S.M., Almannaei, K., Fusch, C., Shivananda, S., Compression force on the upper jaw during neonatal intubation: Mannequin study. J Paediatr Child Health 51:3 (2015), 323–328.
    • (2015) J Paediatr Child Health , vol.51 , Issue.3 , pp. 323-328
    • Doreswamy, S.M.1    Almannaei, K.2    Fusch, C.3    Shivananda, S.4
  • 24
    • 84992124120 scopus 로고    scopus 로고
    • Development and validation of a instrumented neonatal intubation skill trainer for simulation-based education enhancement
    • [24] Tognarelli, S., Baldoli, I., Scaramuzzo, R.T., Ciantelli, M., Cecchi, F., Gentile, M., et al. Development and validation of a instrumented neonatal intubation skill trainer for simulation-based education enhancement. Int J Med Res Health Sci 3:4 (2014), 833–839.
    • (2014) Int J Med Res Health Sci , vol.3 , Issue.4 , pp. 833-839
    • Tognarelli, S.1    Baldoli, I.2    Scaramuzzo, R.T.3    Ciantelli, M.4    Cecchi, F.5    Gentile, M.6
  • 25
    • 85006265880 scopus 로고    scopus 로고
    • Web page:. [accessed 13.01.16].
    • [25] Web page: http://www.laerdal.com/it/doc/218/Trainer-Laerdal-per-intubazione-neonatale. 2016 [accessed 13.01.16].
    • (2016)
  • 26
    • 0035489889 scopus 로고    scopus 로고
    • SIAARTI GUIDELINES: recommendations for difficult intubation and difficult airway control during the pediatric age
    • [26] SIAARTI Task Force. SIAARTI GUIDELINES: recommendations for difficult intubation and difficult airway control during the pediatric age. Minerva Anestesiol 67 (2001), 683–692.
    • (2001) Minerva Anestesiol , vol.67 , pp. 683-692
  • 27
    • 0028951626 scopus 로고
    • Does experience influence the forces exerted on maxillary incisors during laryngoscopy? A manikin study using the Macintosh laryngoscope
    • [27] Bucx, M.J., van Geel, R.T., Wegener, J.T., Robers, C., Stijnen, T., Does experience influence the forces exerted on maxillary incisors during laryngoscopy? A manikin study using the Macintosh laryngoscope. Can J Anaesth 42:2 (1995), 144–149.
    • (1995) Can J Anaesth , vol.42 , Issue.2 , pp. 144-149
    • Bucx, M.J.1    van Geel, R.T.2    Wegener, J.T.3    Robers, C.4    Stijnen, T.5
  • 28
    • 56749169040 scopus 로고    scopus 로고
    • A technique for conditioning and calibrating force-sensing resistors for repeatable and reliable measurement of compressive force
    • [28] Hall, R.S., Desmoulin, G.T., Milner, T.E., A technique for conditioning and calibrating force-sensing resistors for repeatable and reliable measurement of compressive force. J Biomech 41:16 (2008), 3492–3495.
    • (2008) J Biomech , vol.41 , Issue.16 , pp. 3492-3495
    • Hall, R.S.1    Desmoulin, G.T.2    Milner, T.E.3
  • 29
    • 85006267233 scopus 로고    scopus 로고
    • FSR force sensing resistor integration guide and evaluation parts catalog, [accessed 13.01.16]
    • [29] Web page: Interlink Electronics Inc. FSR force sensing resistor integration guide and evaluation parts catalog, http://www.ladyada.net/media/sensors/fsrguide.pdf; 2016 [accessed 13.01.16].
    • (2016)
  • 30
    • 0035106769 scopus 로고    scopus 로고
    • Evaluation of a sensor for low interface pressure applications
    • [30] Ferguson-Pell, M., Hagisawa, S., Bain, D., Evaluation of a sensor for low interface pressure applications. Med Eng Phys 22:9 (2000), 657–663.
    • (2000) Med Eng Phys , vol.22 , Issue.9 , pp. 657-663
    • Ferguson-Pell, M.1    Hagisawa, S.2    Bain, D.3
  • 32
    • 85006315769 scopus 로고    scopus 로고
    • [accessed 13.06.16].
    • [32] Web page: Eeonyx web site, www.eeonyx.com; 2016 [ accessed 13.06.16].
    • (2016)
  • 34
    • 0035246739 scopus 로고    scopus 로고
    • A novel pressure array sensor based on contact resistance variation: Metrological properties
    • [34] Del Prete, Z., Monteleone, L., Steindler, R., A novel pressure array sensor based on contact resistance variation: Metrological properties. Rev Sci Instrum 72:2 (2001), 1548–1553.
    • (2001) Rev Sci Instrum , vol.72 , Issue.2 , pp. 1548-1553
    • Del Prete, Z.1    Monteleone, L.2    Steindler, R.3
  • 37
    • 21344485856 scopus 로고
    • Relative power of the Wilcoxon test, the Friedman test, and repeated-measures ANOVA on ranks
    • [37] Zimmerman, D.W., Zumbo, B.D., Relative power of the Wilcoxon test, the Friedman test, and repeated-measures ANOVA on ranks. J Exp Educ 62:1 (1993), 75–86.
    • (1993) J Exp Educ , vol.62 , Issue.1 , pp. 75-86
    • Zimmerman, D.W.1    Zumbo, B.D.2
  • 38
    • 0003542250 scopus 로고
    • Multiple comparison procedures
    • Wiley New York
    • [38] Hochberg, Y., Tamhane, A.C., Multiple comparison procedures. 1987, Wiley, New York, 98.
    • (1987) , pp. 98
    • Hochberg, Y.1    Tamhane, A.C.2
  • 39
    • 78650405375 scopus 로고    scopus 로고
    • Discovering the false discovery rate
    • [39] Benjamini, Y., Discovering the false discovery rate. J R Stat Soc B Stat Methodol 72 (2010), 405–416.
    • (2010) J R Stat Soc B Stat Methodol , vol.72 , pp. 405-416
    • Benjamini, Y.1
  • 40
    • 84885414339 scopus 로고    scopus 로고
    • Analysis of balance, rapidity, force and reaction times of soccer players at different levels of competition
    • [40] Ricotti, L., Rigosa, J., Niosi, A., Menciassi, A., Analysis of balance, rapidity, force and reaction times of soccer players at different levels of competition. PloS ONE, 8(10), 2013, e77264.
    • (2013) PloS ONE , vol.8 , Issue.10 , pp. e77264
    • Ricotti, L.1    Rigosa, J.2    Niosi, A.3    Menciassi, A.4
  • 41
    • 84986598335 scopus 로고    scopus 로고
    • Identifying characteristic back shapes from anatomical scans of wheelchair users to improve seating design
    • [Epub ahead of print]
    • [41] Crytzer, T.M., Hong, E.K., Dicianno, B., Pearlman, J., Schmeler, M., Cooper, R.A., Identifying characteristic back shapes from anatomical scans of wheelchair users to improve seating design. Med Eng Phys, 2016, 10.1016/j.medengphy.2016.06.017 [Epub ahead of print].
    • (2016) Med Eng Phys
    • Crytzer, T.M.1    Hong, E.K.2    Dicianno, B.3    Pearlman, J.4    Schmeler, M.5    Cooper, R.A.6
  • 42
    • 79953284940 scopus 로고    scopus 로고
    • Forces applied to the maxillary incisors during tracheal intubation and dental injury risks of intubation by beginners: a manikin study
    • [42] Fukuda, T., Sugimoto, Y., Yamashita, S., Toyooka, H., Tanaka, M., Forces applied to the maxillary incisors during tracheal intubation and dental injury risks of intubation by beginners: a manikin study. Acta Anaesthesiol Taiwan 49:1 (2011), 12–15.
    • (2011) Acta Anaesthesiol Taiwan , vol.49 , Issue.1 , pp. 12-15
    • Fukuda, T.1    Sugimoto, Y.2    Yamashita, S.3    Toyooka, H.4    Tanaka, M.5
  • 43
    • 0034104349 scopus 로고    scopus 로고
    • A new practical classification of laryngeal view
    • [43] Cook, T.M., A new practical classification of laryngeal view. Anaesthesia 55:3 (2000), 274–279.
    • (2000) Anaesthesia , vol.55 , Issue.3 , pp. 274-279
    • Cook, T.M.1
  • 44
    • 84910022892 scopus 로고    scopus 로고
    • Comparison of the laryngoscopy views with the size 1 Miller and Macintosh laryngoscope blades lifting the epiglottis or the base of the tongue in infants and children< 2 yr of age
    • aeu228
    • [44] Passi, Y., Sathyamoorthy, M., Lerman, J., Heard, C., Marino, M., Comparison of the laryngoscopy views with the size 1 Miller and Macintosh laryngoscope blades lifting the epiglottis or the base of the tongue in infants and children< 2 yr of age. Br J Anaesth, 2014 aeu228.
    • (2014) Br J Anaesth
    • Passi, Y.1    Sathyamoorthy, M.2    Lerman, J.3    Heard, C.4    Marino, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.