1
-
-
0035218107
-
A novel force transducer for the measurement of grip force
-
Chadwick, E. K. J. and Nicol, A. C. A novel force transducer for the measurement of grip force. J. Biomech., 2001, 34(1), 125-128.
-
(2001)
J. Biomech
, vol.34
, Issue.1
, pp. 125-128
-
-
Chadwick, E.K.J.1
Nicol, A.C.2
-
2
-
-
0035105304
-
A system for the measurement of grip forces and applied moments during hand toot use
-
McGorry, R. W. A system for the measurement of grip forces and applied moments during hand toot use. Appl. Ergon., 2001, 32(3), 271-279.
-
(2001)
Appl. Ergon
, vol.32
, Issue.3
, pp. 271-279
-
-
McGorry, R.W.1
-
3
-
-
0035236858
-
A novel instrumented ring for the measurement of grip force adjustments during precision grip tasks
-
Van der Kamp, M., Conway, B. A., and Nicol, A. C. A novel instrumented ring for the measurement of grip force adjustments during precision grip tasks. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2001, 215(H2), 421-427.
-
(2001)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.215
, Issue.H2
, pp. 421-427
-
-
Van der Kamp, M.1
Conway, B.A.2
Nicol, A.C.3
-
4
-
-
0027088816
-
Using force sensitive resistors to evaluate hand tool grip design
-
Santa Monica, CA
-
Yun, M. H., Kotani, K., and Ellis, D. Using force sensitive resistors to evaluate hand tool grip design. In Proceedings of the Human Factors Society 36th Annual Meeting, Santa Monica, CA, 1992, pp. 806-810.
-
(1992)
Proceedings of the Human Factors Society 36th Annual Meeting
, pp. 806-810
-
-
Yun, M.H.1
Kotani, K.2
Ellis, D.3
-
5
-
-
0003584091
-
-
Academic Press, London
-
Bray, A., Barbato, G., and Levi, R. Theory and practice of force measurement, 1990 (Academic Press, London).
-
(1990)
Theory and practice of force measurement
-
-
Bray, A.1
Barbato, G.2
Levi, R.3
-
6
-
-
0023434276
-
Variation of finger forces in maximal isometric grasp tests on a range of cylinder diameters
-
Amis, A. A. Variation of finger forces in maximal isometric grasp tests on a range of cylinder diameters. J. Biomed. Eng., 1987, 9, 313-320.
-
(1987)
J. Biomed. Eng
, vol.9
, pp. 313-320
-
-
Amis, A.A.1
-
7
-
-
0018836690
-
Hand strength measurement instruments
-
An, K. N., Chao, E. Y. S., and Askew, L. J. Hand strength measurement instruments. Arch. Phys. Med. Rehabil., 1980, 61, 366-368.
-
(1980)
Arch. Phys. Med. Rehabil
, vol.61
, pp. 366-368
-
-
An, K.N.1
Chao, E.Y.S.2
Askew, L.J.3
-
8
-
-
33646024967
-
Measuring contact area, force, and pressure for bioengineering applications: Using Fuji Film and TekScan systems
-
Bachus, K. N., DeMarco, A. L., Judd, K. T., Horwitz, D. S., and Brodke, D. S. Measuring contact area, force, and pressure for bioengineering applications: using Fuji Film and TekScan systems. Med. Eng. Phys., 2006, 28(5), 483-488.
-
(2006)
Med. Eng. Phys
, vol.28
, Issue.5
, pp. 483-488
-
-
Bachus, K.N.1
DeMarco, A.L.2
Judd, K.T.3
Horwitz, D.S.4
Brodke, D.S.5
-
9
-
-
28444458091
-
Accuracy and repeatability of a new method for measuring facet loads in the lumbar spine
-
Wilson, D. C., Niosi, C. A., Zhu, Q. A., Oxland, T. R., and Wilson, D. R. Accuracy and repeatability of a new method for measuring facet loads in the lumbar spine. J. Biomech., 2006, 39(2), 348-353.
-
(2006)
J. Biomech
, vol.39
, Issue.2
, pp. 348-353
-
-
Wilson, D.C.1
Niosi, C.A.2
Zhu, Q.A.3
Oxland, T.R.4
Wilson, D.R.5
-
10
-
-
0242606959
-
Accuracy and repeatability of a pressure measurement system in the patellofemoral joint
-
Wilson, D. R., Apreleva, M. V., Eichler, M. J., and Harrold, F. R. Accuracy and repeatability of a pressure measurement system in the patellofemoral joint. J. Biomech., 2003, 36, 1909-1915.
-
(2003)
J. Biomech
, vol.36
, pp. 1909-1915
-
-
Wilson, D.R.1
Apreleva, M.V.2
Eichler, M.J.3
Harrold, F.R.4
-
11
-
-
0037141866
-
Accuracy and precision of two in-shoe pressure measurement systems
-
Hsiao, H., Guan, J., and Weatherly, M. Accuracy and precision of two in-shoe pressure measurement systems. Ergonomics, 2002, 45(8), 537-555.
-
(2002)
Ergonomics
, vol.45
, Issue.8
, pp. 537-555
-
-
Hsiao, H.1
Guan, J.2
Weatherly, M.3
-
12
-
-
0035106769
-
Evaluation of a sensor for low interface pressure applications
-
Ferguson-Pell, M., Hagisawa, S., and Bain, D. Evaluation of a sensor for low interface pressure applications. Med. Eng. Phys., 2000, 22, 657-663.
-
(2000)
Med. Eng. Phys
, vol.22
, pp. 657-663
-
-
Ferguson-Pell, M.1
Hagisawa, S.2
Bain, D.3
-
13
-
-
0034098032
-
Scientific validation of two commercial pressure sensor systems for prosthetic socket fit
-
Polliack, A. A., Sieh, R. C., Craig, D. D., Landsberger, S., McNeil, D. R., and Ayyappa, E. Scientific validation of two commercial pressure sensor systems for prosthetic socket fit. Prosthet. Orthot. Int., 2000, 24, 63-73.
-
(2000)
Prosthet. Orthot. Int
, vol.24
, pp. 63-73
-
-
Polliack, A.A.1
Sieh, R.C.2
Craig, D.D.3
Landsberger, S.4
McNeil, D.R.5
Ayyappa, E.6
-
14
-
-
0031472871
-
Calibration problems encountered while monitoring stumps/socket interface pressures with force sensing resistors: Techniques adopted to minimise inaccuracies
-
Buis, A. W. P. and Convery, P. Calibration problems encountered while monitoring stumps/socket interface pressures with force sensing resistors: techniques adopted to minimise inaccuracies. Prosthet. Orthot. Int., 1997, 21, 179-182.
-
(1997)
Prosthet. Orthot. Int
, vol.21
, pp. 179-182
-
-
Buis, A.W.P.1
Convery, P.2
-
15
-
-
0030200832
-
Observations on the F-Scan in-shoe pressure measuring system
-
Woodburn, J. and Helliwell, P. S. Observations on the F-Scan in-shoe pressure measuring system. Clin. Biomech., 1996, 11(5), 301-304.
-
(1996)
Clin. Biomech
, vol.11
, Issue.5
, pp. 301-304
-
-
Woodburn, J.1
Helliwell, P.S.2
-
16
-
-
0342674306
-
Evaluation of a dynamic intra-articular contact pressure sensing system
-
Orthopaedic Research Society, Orlando, Florida
-
Werner, F. W., Green, J. K., Fortino, M. D., Mann, K. A., and Short, W. H. Evaluation of a dynamic intra-articular contact pressure sensing system. In 41st Annual Meeting, Orthopaedic Research Society, Orlando, Florida, 1995, p. 705.
-
(1995)
41st Annual Meeting
, pp. 705
-
-
Werner, F.W.1
Green, J.K.2
Fortino, M.D.3
Mann, K.A.4
Short, W.H.5
-
17
-
-
0343980414
-
Can the Tekscan sensor accurately measure dynamic pressures in the knee joint
-
American Society of Biomechanics, Iowa City, Iowa
-
Pavlovic, J. L., Takahashi, Y., Bechtold, J. E., Gustilo, R. B., and Kyle, R. F. Can the Tekscan sensor accurately measure dynamic pressures in the knee joint. In 17th Annual Meeting, American Society of Biomechanics, Iowa City, Iowa, 1993, pp. 135-136.
-
(1993)
17th Annual Meeting
, pp. 135-136
-
-
Pavlovic, J.L.1
Takahashi, Y.2
Bechtold, J.E.3
Gustilo, R.B.4
Kyle, R.F.5
-
19
-
-
38349017306
-
-
Guide to the measurement of force. The Institute of Measurement and Control
-
The Institute of Measurement and Control. Guide to the measurement of force. The Institute of Measurement and Control, 1998.
-
(1998)
The Institute of Measurement and Control
-
-
-
20
-
-
38349020530
-
Thin, flexible sensors for grip force measurements in sport
-
Tokyo
-
Schmidt, E. R., Roberts, J. R., and Rothberg, S. J. Thin, flexible sensors for grip force measurements in sport. In Asia Pacific Congress on Sports Technology, Tokyo, 2005, pp. 399-405.
-
(2005)
Asia Pacific Congress on Sports Technology
, pp. 399-405
-
-
Schmidt, E.R.1
Roberts, J.R.2
Rothberg, S.J.3
-
22
-
-
0018475974
-
Measuring grip pressure during the golf swing
-
Budney, D. R. Measuring grip pressure during the golf swing. Res. Q., 1979, 50(2), pp. 272-277.
-
(1979)
Res. Q
, vol.50
, Issue.2
, pp. 272-277
-
-
Budney, D.R.1
-
23
-
-
2642587319
-
The application of force-sensing resistor sensors for measuring forces developed by the human hand
-
Nikonovas, A., Harrison, A. J. L., Hoult, S., and Sammut, D. The application of force-sensing resistor sensors for measuring forces developed by the human hand. Proc. Insm Mech. Engrs, Part H: J. Engineering in Medicine, 2004, 218, 121-125.
-
(2004)
Proc. Insm Mech. Engrs, Part H: J. Engineering in Medicine
, vol.218
, pp. 121-125
-
-
Nikonovas, A.1
Harrison, A.J.L.2
Hoult, S.3
Sammut, D.4
-
24
-
-
17544363108
-
Optimal cylindrical handle diameter for grip force tasks
-
Kong, Y.-K. and Lowe, B. D. Optimal cylindrical handle diameter for grip force tasks. Int. J. Ind. Ergon., 2005, 35, 495-507.
-
(2005)
Int. J. Ind. Ergon
, vol.35
, pp. 495-507
-
-
Kong, Y.-K.1
Lowe, B.D.2
-
25
-
-
38349059007
-
Time-resolved measurements of grip force during a golf shot
-
Eds E.F. Moritz and S. Haake, Springer, New York
-
Schmidt, E. R., Roberts, J., and Rothberg, S. Time-resolved measurements of grip force during a golf shot. In The engineering of sport 6 (Eds E.F. Moritz and S. Haake), 2006, pp. 57-62 (Springer, New York).
-
(2006)
The engineering of sport 6
, pp. 57-62
-
-
Schmidt, E.R.1
Roberts, J.2
Rothberg, S.3
-
26
-
-
0012217795
-
Evaluation of golf club control by grip pressure measurement
-
E & FN Spon, London
-
Budney, D. R. and Bellow, D. G. Evaluation of golf club control by grip pressure measurement. In Science of golf I, 1990, pp. 30-35 (E & FN Spon, London).
-
(1990)
Science of golf I
, pp. 30-35
-
-
Budney, D.R.1
Bellow, D.G.2
-
27
-
-
38349009552
-
-
BS PD 6461-3: 1995. General metrology: guide to the expression of uncertainty in measurement, 1995.
-
BS PD 6461-3: 1995. General metrology: guide to the expression of uncertainty in measurement, 1995.
-
-
-
|