메뉴 건너뛰기




Volumn , Issue , 2016, Pages 37-47

Respiratory variation in aortic blood flow peak velocity to predict fluid responsiveness in mechanically ventilated children: a systematic review and meta-analysis

Author keywords

blood flow velocity; cardiac output; child; fluid therapy; hemodynamics

Indexed keywords

AORTA; AORTA FLOW; ARTIFICIAL VENTILATION; BLOOD FLOW PEAK VELOCITY; BLOOD FLOW VELOCITY; BREATHING; BREATHING MECHANICS; CHILD; DIAGNOSTIC ACCURACY; DIAGNOSTIC ODDS RATIO; DIAGNOSTIC TEST ACCURACY STUDY; FLUID RESPONSIVENESS; FLUID THERAPY; HEART PRELOAD; HUMAN; INFANT; META ANALYSIS; NEGATIVE LIKELIHOOD RATIO; PHYSIOLOGY; POSITIVE LIKELIHOOD RATIO; PREDICTION; PRESCHOOL CHILD; PRIORITY JOURNAL; RANDOM EFFECTS MODEL; RECEIVER OPERATING CHARACTERISTIC; REPRODUCIBILITY; REVIEW; SENSITIVITY AND SPECIFICITY; STATISTICAL ANALYSIS; SYSTEMATIC REVIEW; TREATMENT RESPONSE;

EID: 84979915837     PISSN: 11555645     EISSN: 14609592     Source Type: Journal    
DOI: 10.1111/pan.12803     Document Type: Review
Times cited : (48)

References (48)
  • 1
    • 0036283553 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence
    • Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 2002; 121: 2000–2008.
    • (2002) Chest , vol.121 , pp. 2000-2008
    • Michard, F.1    Teboul, J.L.2
  • 2
    • 0033797681 scopus 로고    scopus 로고
    • Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation
    • Michard F, Teboul JL. Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation. Crit Care 2000; 4: 282–289
    • (2000) Crit Care , vol.4 , pp. 282-289
    • Michard, F.1    Teboul, J.L.2
  • 3
    • 69349089330 scopus 로고    scopus 로고
    • Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature
    • Marik PE, Cavallazzi R, Vasu T et al. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 2009; 37: 2642–2647.
    • (2009) Crit Care Med , vol.37 , pp. 2642-2647
    • Marik, P.E.1    Cavallazzi, R.2    Vasu, T.3
  • 4
    • 77952582244 scopus 로고    scopus 로고
    • Arterial pressure variation and goal-directed fluid therapy
    • Cannesson M. Arterial pressure variation and goal-directed fluid therapy. J Cardiothorac Vasc Anesth 2010; 24: 487–497.
    • (2010) J Cardiothorac Vasc Anesth , vol.24 , pp. 487-497
    • Cannesson, M.1
  • 5
    • 84988698623 scopus 로고    scopus 로고
    • The effects of goal-directed fluid therapy based on dynamic parameters on post-surgical outcome: a meta-analysis of randomized controlled trials
    • Benes J, Giglio M, Brienza N et al. The effects of goal-directed fluid therapy based on dynamic parameters on post-surgical outcome: a meta-analysis of randomized controlled trials. Crit Care 2014; 18: 584.
    • (2014) Crit Care , vol.18 , pp. 584
    • Benes, J.1    Giglio, M.2    Brienza, N.3
  • 6
    • 84889061184 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in children: a systematic review
    • Gan H, Cannesson M, Chandler JR et al. Predicting fluid responsiveness in children: a systematic review. Anesth Analg 2013; 117: 1380–1392.
    • (2013) Anesth Analg , vol.117 , pp. 1380-1392
    • Gan, H.1    Cannesson, M.2    Chandler, J.R.3
  • 7
    • 0035092478 scopus 로고    scopus 로고
    • Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock
    • Feissel M, Michard F, Mangin I et al. Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 2001; 119: 867–873.
    • (2001) Chest , vol.119 , pp. 867-873
    • Feissel, M.1    Michard, F.2    Mangin, I.3
  • 8
    • 84886502216 scopus 로고    scopus 로고
    • Guidelines for perioperative haemodynamic optimization
    • Vallet B, Blanloeil Y, Cholley B et al. Guidelines for perioperative haemodynamic optimization. Ann Fr Anesth Reanim 2013; 32: e151–e158.
    • (2013) Ann Fr Anesth Reanim , vol.32 , pp. e151-e158
    • Vallet, B.1    Blanloeil, Y.2    Cholley, B.3
  • 9
    • 84925548115 scopus 로고    scopus 로고
    • Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement
    • Moher D, Liberati A, Tetzlaff J et al. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. J Clin Epidemiol 2009; 62: 1006–1012.
    • (2009) J Clin Epidemiol , vol.62 , pp. 1006-1012
    • Moher, D.1    Liberati, A.2    Tetzlaff, J.3
  • 10
    • 2942700307 scopus 로고    scopus 로고
    • The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews
    • Whiting PRA, Reitsma JB, Bossuyt PM et al. The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol 2003; 3: 25–38.
    • (2003) BMC Med Res Methodol , vol.3 , pp. 25-38
    • Whiting, P.R.A.1    Reitsma, J.B.2    Bossuyt, P.M.3
  • 11
    • 33747851721 scopus 로고    scopus 로고
    • MetaDiSc: a software for meta-analysis of test accuracy data
    • Zamora J, Abraira V, Muriel A et al. MetaDiSc: a software for meta-analysis of test accuracy data. BMC Med Res Methodol 2006; 6: 31.
    • (2006) BMC Med Res Methodol , vol.6 , pp. 31
    • Zamora, J.1    Abraira, V.2    Muriel, A.3
  • 12
    • 0242629046 scopus 로고    scopus 로고
    • The diagnostic odds ratio: a single indicator of test performance
    • Glas AS, Lijmer JG, Prins MH et al. The diagnostic odds ratio: a single indicator of test performance. J Clin Epidemiol 2003; 56: 1129–1135.
    • (2003) J Clin Epidemiol , vol.56 , pp. 1129-1135
    • Glas, A.S.1    Lijmer, J.G.2    Prins, M.H.3
  • 13
    • 0027290944 scopus 로고
    • Combining independent studies of a diagnostic test into a summary ROC curve: data-analytic approaches and some additional considerations
    • Moses LE, Shapiro D, Littenberg B. Combining independent studies of a diagnostic test into a summary ROC curve: data-analytic approaches and some additional considerations. Stat Med 1993; 12: 1293–1316.
    • (1993) Stat Med , vol.12 , pp. 1293-1316
    • Moses, L.E.1    Shapiro, D.2    Littenberg, B.3
  • 14
    • 0037098199 scopus 로고    scopus 로고
    • Quantifying heterogeneity in a metaanalysis
    • Higgins JP, Thompson SG. Quantifying heterogeneity in a metaanalysis. Stat Med 2002; 21: 1539–1558.
    • (2002) Stat Med , vol.21 , pp. 1539-1558
    • Higgins, J.P.1    Thompson, S.G.2
  • 15
    • 0041876133 scopus 로고    scopus 로고
    • Measuring inconsistency in meta-analyses
    • Higgins JP, Thompson SG, Deeks JJ et al. Measuring inconsistency in meta-analyses. BMJ 2003; 327: 557–560.
    • (2003) BMJ , vol.327 , pp. 557-560
    • Higgins, J.P.1    Thompson, S.G.2    Deeks, J.J.3
  • 16
    • 70349235819 scopus 로고    scopus 로고
    • Understanding heterogeneity in meta-analysis: the role of metaregression
    • Baker WL, White CM, Cappelleri JC et al. Understanding heterogeneity in meta-analysis: the role of metaregression. Int J Clin Pract 2009; 63: 1426–1434.
    • (2009) Int J Clin Pract , vol.63 , pp. 1426-1434
    • Baker, W.L.1    White, C.M.2    Cappelleri, J.C.3
  • 17
    • 42449127054 scopus 로고    scopus 로고
    • Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children
    • Durand P, Chevret L, Essouri S et al. Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children. Intensive Care Med 2008; 34: 888–894.
    • (2008) Intensive Care Med , vol.34 , pp. 888-894
    • Durand, P.1    Chevret, L.2    Essouri, S.3
  • 18
    • 78449276917 scopus 로고    scopus 로고
    • Respiratory variation in aortic blood flow velocity as a predictor of fluid responsiveness in children after repair of ventricular septal defect
    • Choi DY, Kwak HJ, Park HY et al. Respiratory variation in aortic blood flow velocity as a predictor of fluid responsiveness in children after repair of ventricular septal defect. Pediatr Cardiol 2010; 31: 1166–1170.
    • (2010) Pediatr Cardiol , vol.31 , pp. 1166-1170
    • Choi, D.Y.1    Kwak, H.J.2    Park, H.Y.3
  • 19
    • 79957533123 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography
    • Pereira de Souza Neto P, Neto E, Grousson S et al. Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography. Br J Anaesth 2011; 106: 856–864.
    • (2011) Br J Anaesth , vol.106 , pp. 856-864
    • Pereira de Souza Neto, P.1    Neto, E.2    Grousson, S.3
  • 20
    • 79959659600 scopus 로고    scopus 로고
    • Non-invasive prediction of fluid responsiveness in infants using pleth variability index
    • Renner J, Broch O, Gruenewald M et al. Non-invasive prediction of fluid responsiveness in infants using pleth variability index. Anaesthesia 2011; 66: 582–589.
    • (2011) Anaesthesia , vol.66 , pp. 582-589
    • Renner, J.1    Broch, O.2    Gruenewald, M.3
  • 21
    • 84875651880 scopus 로고    scopus 로고
    • Prediction of fluid responsiveness in mechanically ventilated children undergoing neurosurgery
    • Byon HJ, Lim CW, Lee JH et al. Prediction of fluid responsiveness in mechanically ventilated children undergoing neurosurgery. Br J Anaesth 2013; 110: 586–589.
    • (2013) Br J Anaesth , vol.110 , pp. 586-589
    • Byon, H.J.1    Lim, C.W.2    Lee, J.H.3
  • 22
    • 84893658401 scopus 로고    scopus 로고
    • The ability of stroke volume variation measured by a noninvasive cardiac output monitor to predict fluid responsiveness in mechanically ventilated children
    • Lee JY, Kim JY, Choi CH et al. The ability of stroke volume variation measured by a noninvasive cardiac output monitor to predict fluid responsiveness in mechanically ventilated children. Pediatr Cardiol 2014; 35: 289–294.
    • (2014) Pediatr Cardiol , vol.35 , pp. 289-294
    • Lee, J.Y.1    Kim, J.Y.2    Choi, C.H.3
  • 23
    • 80052361531 scopus 로고    scopus 로고
    • Advanced hemodynamic monitoring in critically ill children
    • Lemson J, Nusmeier A, van der Hoeven JG. Advanced hemodynamic monitoring in critically ill children. Pediatrics 2011; 128: 560–571.
    • (2011) Pediatrics , vol.128 , pp. 560-571
    • Lemson, J.1    Nusmeier, A.2    van der Hoeven, J.G.3
  • 24
    • 0023890867 scopus 로고
    • Measuring the accuracy of diagnostic systems
    • Swets JA. Measuring the accuracy of diagnostic systems. Science 1988; 240: 1285–1293.
    • (1988) Science , vol.240 , pp. 1285-1293
    • Swets, J.A.1
  • 25
    • 7444242050 scopus 로고    scopus 로고
    • Editorial II: solid as a ROC
    • Galley HF. Editorial II: solid as a ROC. Br J Anaesth 2004; 93: 623–626.
    • (2004) Br J Anaesth , vol.93 , pp. 623-626
    • Galley, H.F.1
  • 26
    • 84866738251 scopus 로고    scopus 로고
    • Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis
    • Sandroni C, Cavallaro F, Marano C et al. Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis. Intensive Care Med 2012; 38: 1429–1437.
    • (2012) Intensive Care Med , vol.38 , pp. 1429-1437
    • Sandroni, C.1    Cavallaro, F.2    Marano, C.3
  • 27
    • 84881246879 scopus 로고    scopus 로고
    • Developmental changes in left and right ventricular function evaluated with color tissue Doppler imaging and strain echocardiography
    • Akao M, Katsube Y, Kamisago M et al. Developmental changes in left and right ventricular function evaluated with color tissue Doppler imaging and strain echocardiography. J Nippon Med Sch 2013; 80: 260–267.
    • (2013) J Nippon Med Sch , vol.80 , pp. 260-267
    • Akao, M.1    Katsube, Y.2    Kamisago, M.3
  • 28
    • 0028924132 scopus 로고
    • Noninvasive assessment of myocardial contractility, preload, and afterload in healthy newborn infants
    • Rowland DG, Gutgesell HP. Noninvasive assessment of myocardial contractility, preload, and afterload in healthy newborn infants. Am J Cardiol 1995; 75: 818–821.
    • (1995) Am J Cardiol , vol.75 , pp. 818-821
    • Rowland, D.G.1    Gutgesell, H.P.2
  • 29
    • 0018762623 scopus 로고
    • Relation of ultrastructure and function. Sarcomere dimensions, pressure-volume curves, and geometry of the intact left ventricle of the immature canine heart
    • Spotnitz WD, Spotnitz HM, Truccone NJ et al. Relation of ultrastructure and function. Sarcomere dimensions, pressure-volume curves, and geometry of the intact left ventricle of the immature canine heart. Circ Res 1979; 44: 679–691.
    • (1979) Circ Res , vol.44 , pp. 679-691
    • Spotnitz, W.D.1    Spotnitz, H.M.2    Truccone, N.J.3
  • 30
    • 84890790518 scopus 로고    scopus 로고
    • Limitations and vulnerabilities of the neonatal cardiovascular system: considerations for anesthetic management
    • Wolf AR, Humphry AT. Limitations and vulnerabilities of the neonatal cardiovascular system: considerations for anesthetic management. Pediatr Anesth 2014; 24: 5–9.
    • (2014) Pediatr Anesth , vol.24 , pp. 5-9
    • Wolf, A.R.1    Humphry, A.T.2
  • 31
    • 38849150257 scopus 로고    scopus 로고
    • Pulse pressure variation and stroke volume variation during different loading conditions in a paediatric animal model
    • Renner J, Cavus E, Meybohm P et al. Pulse pressure variation and stroke volume variation during different loading conditions in a paediatric animal model. Acta Anaesthesiol Scand 2008; 52: 374–380.
    • (2008) Acta Anaesthesiol Scand , vol.52 , pp. 374-380
    • Renner, J.1    Cavus, E.2    Meybohm, P.3
  • 32
    • 17444414557 scopus 로고    scopus 로고
    • Pulse pressure variations to predict fluid responsiveness: inluence of tidal volume
    • De BD, Heenen S, Piagnerelli M et al. Pulse pressure variations to predict fluid responsiveness: inluence of tidal volume. Intensive Care Med 2005; 31: 517–523.
    • (2005) Intensive Care Med , vol.31 , pp. 517-523
    • De, B.D.1    Heenen, S.2    Piagnerelli, M.3
  • 33
    • 67149123643 scopus 로고    scopus 로고
    • Effects of norepinephrine on dynamic variables of fluid responsiveness during hemorrhage and after resuscitation in a pediatric porcine model
    • Renner J, Meybohm P, Hanss R et al. Effects of norepinephrine on dynamic variables of fluid responsiveness during hemorrhage and after resuscitation in a pediatric porcine model. Pediatr Anesth 2009; 19: 688–694.
    • (2009) Pediatr Anesth , vol.19 , pp. 688-694
    • Renner, J.1    Meybohm, P.2    Hanss, R.3
  • 34
    • 26444484845 scopus 로고    scopus 로고
    • Effects of norepinephrine on static and dynamic preload indicators in experimental hemorrhagic shock
    • Nouira S, Elatrous S, Dimassi S et al. Effects of norepinephrine on static and dynamic preload indicators in experimental hemorrhagic shock. Crit Care Med 2005; 33: 2339–2343.
    • (2005) Crit Care Med , vol.33 , pp. 2339-2343
    • Nouira, S.1    Elatrous, S.2    Dimassi, S.3
  • 35
    • 0021867398 scopus 로고
    • Physiologic assessment of the inotropic, vasodilator and afterload reducing effects of milrinone in subjects without cardiac disease
    • Borow KM, Come PC, Neumann A et al. Physiologic assessment of the inotropic, vasodilator and afterload reducing effects of milrinone in subjects without cardiac disease. Am J Cardiol 1985; 55: 1204–1209.
    • (1985) Am J Cardiol , vol.55 , pp. 1204-1209
    • Borow, K.M.1    Come, P.C.2    Neumann, A.3
  • 36
    • 0344394235 scopus 로고    scopus 로고
    • Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature
    • Chew MS, Poelaert J. Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature. Intensive Care Med 2003; 29: 1889–1894.
    • (2003) Intensive Care Med , vol.29 , pp. 1889-1894
    • Chew, M.S.1    Poelaert, J.2
  • 37
    • 84888302051 scopus 로고    scopus 로고
    • Systematic error of cardiac output measured by bolus thermodilution with a pulmonary artery catheter compared with that measured by an aortic flow probe in a pig model
    • Yang XX, Critchley LA, Rowlands DK et al. Systematic error of cardiac output measured by bolus thermodilution with a pulmonary artery catheter compared with that measured by an aortic flow probe in a pig model. J Cardiothorac Vasc Anesth 2013; 27: 1133–1139.
    • (2013) J Cardiothorac Vasc Anesth , vol.27 , pp. 1133-1139
    • Yang, X.X.1    Critchley, L.A.2    Rowlands, D.K.3
  • 38
    • 84866258808 scopus 로고    scopus 로고
    • Transcutaneous Doppler (USCOM): an ovine cardiac output validation
    • Phillips RA, Hood SG, Jacobson BM et al. Transcutaneous Doppler (USCOM): an ovine cardiac output validation. Crit Care Res Pract 2012; 2012: 621496.
    • (2012) Crit Care Res Pract , vol.2012 , pp. 621496
    • Phillips, R.A.1    Hood, S.G.2    Jacobson, B.M.3
  • 39
    • 0023887652 scopus 로고
    • Reproducibility of cardiac output measurement by cross sectional and Doppler echocardiography
    • Robson SC, Murray A, Peart I et al. Reproducibility of cardiac output measurement by cross sectional and Doppler echocardiography. Br Heart J 1988; 59: 680–684.
    • (1988) Br Heart J , vol.59 , pp. 680-684
    • Robson, S.C.1    Murray, A.2    Peart, I.3
  • 40
    • 78149469431 scopus 로고    scopus 로고
    • A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output
    • Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg 2010; 111: 1180–1192.
    • (2010) Anesth Analg , vol.111 , pp. 1180-1192
    • Critchley, L.A.1    Lee, A.2    Ho, A.M.3
  • 41
    • 80053322000 scopus 로고    scopus 로고
    • Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a ‘gray zone’ approach
    • Cannesson M, Le Manach Y, Hofer CK et al. Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a ‘gray zone’ approach. Anesthesiology 2011; 115: 231–241.
    • (2011) Anesthesiology , vol.115 , pp. 231-241
    • Cannesson, M.1    Le Manach, Y.2    Hofer, C.K.3
  • 42
    • 84925349427 scopus 로고    scopus 로고
    • Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach
    • Biais M, Ehrmann S, Mari A et al. Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach. Crit Care 2014; 18: 587.
    • (2014) Crit Care , vol.18 , pp. 587
    • Biais, M.1    Ehrmann, S.2    Mari, A.3
  • 43
    • 84877581329 scopus 로고    scopus 로고
    • Plethysmographic variability index (PVI) accuracy in predicting fluid responsiveness in anesthetized children
    • Julien F, Hilly J, Sallah TB et al. Plethysmographic variability index (PVI) accuracy in predicting fluid responsiveness in anesthetized children. Pediatr Anesth 2013; 23: 536–546.
    • (2013) Pediatr Anesth , vol.23 , pp. 536-546
    • Julien, F.1    Hilly, J.2    Sallah, T.B.3
  • 44
    • 84925556208 scopus 로고    scopus 로고
    • Stroke volume variation and indexed stroke volume measured using bioreactance predict fluid responsiveness in postoperative children
    • Vergnaud E, Vidal C, Verchère J et al. Stroke volume variation and indexed stroke volume measured using bioreactance predict fluid responsiveness in postoperative children. Br J Anaesth 2015; 114: 103–109.
    • (2015) Br J Anaesth , vol.114 , pp. 103-109
    • Vergnaud, E.1    Vidal, C.2    Verchère, J.3
  • 45
    • 84925378129 scopus 로고    scopus 로고
    • Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis
    • Yang X, Du B. Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis. Crit Care 2014; 18: 650.
    • (2014) Crit Care , vol.18 , pp. 650
    • Yang, X.1    Du, B.2
  • 46
    • 84862175860 scopus 로고    scopus 로고
    • ® pulse oximeter to predict fluid or preload responsiveness: a systematic review and meta-analysis
    • ® pulse oximeter to predict fluid or preload responsiveness: a systematic review and meta-analysis. Anaesthesia 2012; 67: 777–783.
    • (2012) Anaesthesia , vol.67 , pp. 777-783
    • Yin, J.Y.1    Ho, K.M.2
  • 47
    • 77955925229 scopus 로고    scopus 로고
    • Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies
    • Cavallaro F, Sandroni C, Marano C et al. Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med 2010; 36: 1475–1483.
    • (2010) Intensive Care Med , vol.36 , pp. 1475-1483
    • Cavallaro, F.1    Sandroni, C.2    Marano, C.3
  • 48
    • 84897038744 scopus 로고    scopus 로고
    • Ultrasonographic measurement of the respiratory variation in the inferior vena cava diameter is predictive of fluid responsiveness in critically ill patients: systematic review and meta-analysis
    • Zhang Z, Xu X, Ye S et al. Ultrasonographic measurement of the respiratory variation in the inferior vena cava diameter is predictive of fluid responsiveness in critically ill patients: systematic review and meta-analysis. Ultrasound Med Biol 2014; 40: 845–853.
    • (2014) Ultrasound Med Biol , vol.40 , pp. 845-853
    • Zhang, Z.1    Xu, X.2    Ye, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.