메뉴 건너뛰기




Volumn 40, Issue 5, 2014, Pages 845-853

Ultrasonographic measurement of the respiratory variation in the inferior vena cava diameter is predictive of fluid responsiveness in critically ill patients: Systematic review and meta-analysis

Author keywords

Critical illness; Fluid responsiveness; Mechanical ventilation; Meta analysis; Ultrasonography; Variation in inferior vena cava

Indexed keywords

FORECASTING; RESPIRATORY MECHANICS; ULTRASONOGRAPHY; VENTILATION;

EID: 84897038744     PISSN: 03015629     EISSN: 1879291X     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2013.12.010     Document Type: Review
Times cited : (189)

References (35)
  • 1
    • 0034087866 scopus 로고    scopus 로고
    • Negative fluid balance predicts survival in patients with septic shock: A retrospective pilot study
    • Alsous F., Khamiees M., DeGirolamo A., Amoateng-Adjepong Y., Manthous C.A. Negative fluid balance predicts survival in patients with septic shock: A retrospective pilot study. Chest 2000, 117:1749-1754.
    • (2000) Chest , vol.117 , pp. 1749-1754
    • Alsous, F.1    Khamiees, M.2    DeGirolamo, A.3    Amoateng-Adjepong, Y.4    Manthous, C.A.5
  • 2
    • 85015278454 scopus 로고    scopus 로고
    • Bedside echocardiography in critically ill patients: A true hemodynamic monitoring tool
    • Au S.M., Vieillard-Baron A. Bedside echocardiography in critically ill patients: A true hemodynamic monitoring tool. Curr Cardiol Rev 2011, 7:197-200.
    • (2011) Curr Cardiol Rev , vol.7 , pp. 197-200
    • Au, S.M.1    Vieillard-Baron, A.2
  • 3
    • 4644226589 scopus 로고    scopus 로고
    • Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients
    • Barbier C., Loubières Y., Schmit C., Hayon J., Ricôme J.L., Jardin F., Vieillard-Baron A. Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med 2004, 30:1740-1746.
    • (2004) Intensive Care Med , vol.30 , pp. 1740-1746
    • Barbier, C.1    Loubières, Y.2    Schmit, C.3    Hayon, J.4    Ricôme, J.L.5    Jardin, F.6    Vieillard-Baron, A.7
  • 4
    • 79251546295 scopus 로고    scopus 로고
    • Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality
    • Boyd J.H., Forbes J., Nakada T.A., Walley K.R., Russell J.A. Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality. Crit Care Med 2011, 39:259-265.
    • (2011) Crit Care Med , vol.39 , pp. 259-265
    • Boyd, J.H.1    Forbes, J.2    Nakada, T.A.3    Walley, K.R.4    Russell, J.A.5
  • 6
    • 84875651880 scopus 로고    scopus 로고
    • Prediction of fluid responsiveness in mechanically ventilated children undergoing neurosurgery
    • Byon H.J., Lim C.W., Lee J.H., Park Y.H., Kim H.S., Kim C.S., Kim J.T. Prediction of fluid responsiveness in mechanically ventilated children undergoing neurosurgery. Br J Anaesth 2013, 110:586-591.
    • (2013) Br J Anaesth , vol.110 , pp. 586-591
    • Byon, H.J.1    Lim, C.W.2    Lee, J.H.3    Park, Y.H.4    Kim, H.S.5    Kim, C.S.6    Kim, J.T.7
  • 7
    • 84867332864 scopus 로고    scopus 로고
    • Bedside sonographic measurement of the inferior vena cava caval index is a poor predictor of fluid responsiveness in emergency department patients
    • Corl K., Napoli A.M., Gardiner F. Bedside sonographic measurement of the inferior vena cava caval index is a poor predictor of fluid responsiveness in emergency department patients. Emerg Med Australas 2012, 24:534-539.
    • (2012) Emerg Med Australas , vol.24 , pp. 534-539
    • Corl, K.1    Napoli, A.M.2    Gardiner, F.3
  • 9
    • 84873050778 scopus 로고    scopus 로고
    • Characteristics of fluids used for intravascular volume replacement
    • De Backer D., Cortés D.O. Characteristics of fluids used for intravascular volume replacement. Best Pract Res Clin Anaesthesiol 2012, 26:441-451.
    • (2012) Best Pract Res Clin Anaesthesiol , vol.26 , pp. 441-451
    • De Backer, D.1    Cortés, D.O.2
  • 10
    • 84878273170 scopus 로고    scopus 로고
    • Influence of trial sample size on treatment effect estimates: Meta-epidemiological study
    • Dechartres A., Trinquart L., Boutron I., Ravaud P. Influence of trial sample size on treatment effect estimates: Meta-epidemiological study. BMJ 2013, 346:f2304.
    • (2013) BMJ , vol.346
    • Dechartres, A.1    Trinquart, L.2    Boutron, I.3    Ravaud, P.4
  • 11
    • 33845571913 scopus 로고    scopus 로고
    • Random-effects model for meta-analysis of clinical trials: an update
    • DerSimonian R., Kacker R. Random-effects model for meta-analysis of clinical trials: an update. Contemp Clin Trials 2007, 28:105-114.
    • (2007) Contemp Clin Trials , vol.28 , pp. 105-114
    • DerSimonian, R.1    Kacker, R.2
  • 12
    • 84869411988 scopus 로고    scopus 로고
    • Role of inferior vena cava diameter in assessment of volume status: A meta-analysis
    • Dipti A., Soucy Z., Surana A., Chandra S. Role of inferior vena cava diameter in assessment of volume status: A meta-analysis. Am J Emerg Med 2012, 30:1414-1419.e1.
    • (2012) Am J Emerg Med , vol.30
    • Dipti, A.1    Soucy, Z.2    Surana, A.3    Chandra, S.4
  • 13
    • 2542457136 scopus 로고    scopus 로고
    • The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
    • Feissel M., Michard F., Faller J.P., Teboul J.L. The respiratory variation in inferior vena cava diameter as a guide to fluid therapy. Intensive Care Med 2004, 30:1834-1837.
    • (2004) Intensive Care Med , vol.30 , pp. 1834-1837
    • Feissel, M.1    Michard, F.2    Faller, J.P.3    Teboul, J.L.4
  • 14
    • 34247550826 scopus 로고    scopus 로고
    • How can the response to volume expansion in patients with spontaneous respiratory movements be predicted?
    • Heenen S., De Backer D., Vincent J.L. How can the response to volume expansion in patients with spontaneous respiratory movements be predicted?. Crit Care 2006, 10:R102.
    • (2006) Crit Care , vol.10
    • Heenen, S.1    De Backer, D.2    Vincent, J.L.3
  • 16
    • 84860221955 scopus 로고    scopus 로고
    • Ultrasound assessment of inferior vena cava collapsibility is not a valid measure of preload changes during triggered positive pressure ventilation: A controlled cross-over study
    • Juhl-Olsen P., Frederiksen C.A., Sloth E. Ultrasound assessment of inferior vena cava collapsibility is not a valid measure of preload changes during triggered positive pressure ventilation: A controlled cross-over study. Ultraschall Med 2012, 33:152-159.
    • (2012) Ultraschall Med , vol.33 , pp. 152-159
    • Juhl-Olsen, P.1    Frederiksen, C.A.2    Sloth, E.3
  • 17
    • 79953903084 scopus 로고    scopus 로고
    • Inferior vena cava variation compared to pulse contour analysis as predictors of fluid responsiveness: A prospective cohort study
    • Machare-Delgado E., Decaro M., Marik P.E. Inferior vena cava variation compared to pulse contour analysis as predictors of fluid responsiveness: A prospective cohort study. JIntensive Care Med 2011, 26:116-124.
    • (2011) JIntensive Care Med , vol.26 , pp. 116-124
    • Machare-Delgado, E.1    Decaro, M.2    Marik, P.E.3
  • 18
    • 84866108994 scopus 로고    scopus 로고
    • Can transthoracic echocardiography be used to predict fluid responsiveness in the critically ill patient? A systematic review
    • Mandeville J.C., Colebourn C.L. Can transthoracic echocardiography be used to predict fluid responsiveness in the critically ill patient? A systematic review. Crit Care Res Pract 2012, 2012:513480.
    • (2012) Crit Care Res Pract , vol.2012 , pp. 513480
    • Mandeville, J.C.1    Colebourn, C.L.2
  • 19
    • 47549096309 scopus 로고    scopus 로고
    • Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares
    • Marik P.E., Baram M., Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 2008, 134:172-178.
    • (2008) Chest , vol.134 , pp. 172-178
    • Marik, P.E.1    Baram, M.2    Vahid, B.3
  • 20
    • 69349089330 scopus 로고    scopus 로고
    • Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature
    • Marik P.E., Cavallazzi R., Vasu T., Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature. Crit Care Med 2009, 37:2642-2647.
    • (2009) Crit Care Med , vol.37 , pp. 2642-2647
    • Marik, P.E.1    Cavallazzi, R.2    Vasu, T.3    Hirani, A.4
  • 21
    • 0024596160 scopus 로고
    • Two-dimensional echocardiographic evaluation of inferior vena cava, right ventricle, and left ventricle during positive-pressure ventilation with varying levels of positive end-expiratory pressure
    • Mitaka C., Nagura T., Sakanishi N., Tsunoda Y., Amaha K. Two-dimensional echocardiographic evaluation of inferior vena cava, right ventricle, and left ventricle during positive-pressure ventilation with varying levels of positive end-expiratory pressure. Crit Care Med 1989, 17:205-210.
    • (1989) Crit Care Med , vol.17 , pp. 205-210
    • Mitaka, C.1    Nagura, T.2    Sakanishi, N.3    Tsunoda, Y.4    Amaha, K.5
  • 22
    • 77954384895 scopus 로고    scopus 로고
    • Inferior vena cava distensibility as a predictor of fluid responsiveness in patients with subarachnoid hemorrhage
    • Moretti R., Pizzi B. Inferior vena cava distensibility as a predictor of fluid responsiveness in patients with subarachnoid hemorrhage. Neurocrit Care 2010, 13:3-9.
    • (2010) Neurocrit Care , vol.13 , pp. 3-9
    • Moretti, R.1    Pizzi, B.2
  • 23
    • 84867054087 scopus 로고    scopus 로고
    • Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: Need for a cautious use
    • the AzuRea Group
    • Muller L., Bobbia X., Toumi M., Louart G., Molinari N., Ragonnet B., Quintard H., Leone M., Zoric L., Lefrant J.Y., the AzuRea Group Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: Need for a cautious use. Crit Care 2012, 16:R188.
    • (2012) Crit Care , vol.16
    • Muller, L.1    Bobbia, X.2    Toumi, M.3    Louart, G.4    Molinari, N.5    Ragonnet, B.6    Quintard, H.7    Leone, M.8    Zoric, L.9    Lefrant, J.Y.10
  • 25
    • 84868199579 scopus 로고    scopus 로고
    • Core review: Physician-performed ultrasound: The time has come for routine use in acute care medicine
    • Royse C.F., Canty D.J., Faris J., Haji D.L., Veltman M., Royse A. Core review: Physician-performed ultrasound: The time has come for routine use in acute care medicine. Anesth Analg 2012, 115:1007-1028.
    • (2012) Anesth Analg , vol.115 , pp. 1007-1028
    • Royse, C.F.1    Canty, D.J.2    Faris, J.3    Haji, D.L.4    Veltman, M.5    Royse, A.6
  • 26
    • 0035888162 scopus 로고    scopus 로고
    • Ahierarchical regression approach to meta-analysis of diagnostic test accuracy evaluations
    • Rutter C.M., Gatsonis C.A. Ahierarchical regression approach to meta-analysis of diagnostic test accuracy evaluations. Stat Med 2001, 20:2865-2884.
    • (2001) Stat Med , vol.20 , pp. 2865-2884
    • Rutter, C.M.1    Gatsonis, C.A.2
  • 27
    • 33645897315 scopus 로고    scopus 로고
    • Cardiac system bioenergetics: Metabolic basis of the Frank-Starling law
    • Saks V., Dzeja P., Schlattner U., Vendelin M., Terzic A., Wallimann T. Cardiac system bioenergetics: Metabolic basis of the Frank-Starling law. JPhysiol 2006, 571(Pt 2):253-273.
    • (2006) JPhysiol , vol.571 , Issue.PART 2 , pp. 253-273
    • Saks, V.1    Dzeja, P.2    Schlattner, U.3    Vendelin, M.4    Terzic, A.5    Wallimann, T.6
  • 29
    • 34447126479 scopus 로고    scopus 로고
    • Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients?
    • Soubrier S., Saulnier F., Hubert H., Delour P., Lenci H., Onimus T., Nseir S., Durocher A. Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients?. Intensive Care Med 2007, 33:1117-1124.
    • (2007) Intensive Care Med , vol.33 , pp. 1117-1124
    • Soubrier, S.1    Saulnier, F.2    Hubert, H.3    Delour, P.4    Lenci, H.5    Onimus, T.6    Nseir, S.7    Durocher, A.8
  • 30
    • 84866539303 scopus 로고    scopus 로고
    • Stroke volume variation as a predictor of fluid responsiveness in patients undergoing airway pressure release ventilation
    • Suehiro K., Rinka H., Ishikawa J., Fuke A., Arimoto H., Miyaichi T. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing airway pressure release ventilation. Anaesth Intensive Care 2012, 40:767-772.
    • (2012) Anaesth Intensive Care , vol.40 , pp. 767-772
    • Suehiro, K.1    Rinka, H.2    Ishikawa, J.3    Fuke, A.4    Arimoto, H.5    Miyaichi, T.6
  • 31
    • 84879581183 scopus 로고    scopus 로고
    • Pulse pressure variation and ARDS
    • Teboul J.L., Monnet X. Pulse pressure variation and ARDS. Minerva Anestesiol 2013, 79:398-407.
    • (2013) Minerva Anestesiol , vol.79 , pp. 398-407
    • Teboul, J.L.1    Monnet, X.2
  • 32
    • 2942700307 scopus 로고    scopus 로고
    • The development of QUADAS: A tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews
    • Whiting P., Rutjes A.W., Reitsma J.B., Bossuyt P.M., Kleijnen J. The development of QUADAS: A tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol 2003, 3:25.
    • (2003) BMC Med Res Methodol , vol.3 , pp. 25
    • Whiting, P.1    Rutjes, A.W.2    Reitsma, J.B.3    Bossuyt, P.M.4    Kleijnen, J.5
  • 33
    • 84876542543 scopus 로고    scopus 로고
    • Validation of pulse pressure variation and corrected flow time as predictors of fluid responsiveness in patients in the prone position
    • Yang S.Y., Shim J.K., Song Y., Seo S.J., Kwak Y.L. Validation of pulse pressure variation and corrected flow time as predictors of fluid responsiveness in patients in the prone position. Br J Anaesth 2013, 110:713-720.
    • (2013) Br J Anaesth , vol.110 , pp. 713-720
    • Yang, S.Y.1    Shim, J.K.2    Song, Y.3    Seo, S.J.4    Kwak, Y.L.5
  • 34
    • 84355166702 scopus 로고    scopus 로고
    • Accuracy of stroke volume variation in predicting fluid responsiveness: A systematic review and meta-analysis
    • Zhang Z., Lu B., Sheng X., Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: A systematic review and meta-analysis. JAnesth 2011, 25:904-916.
    • (2011) JAnesth , vol.25 , pp. 904-916
    • Zhang, Z.1    Lu, B.2    Sheng, X.3    Jin, N.4
  • 35
    • 84872018928 scopus 로고    scopus 로고
    • Small studies may overestimate the effect sizes in critical care meta-analyses: A meta-epidemiological study
    • Zhang Z., Xu X., Ni H. Small studies may overestimate the effect sizes in critical care meta-analyses: A meta-epidemiological study. Crit Care 2013, 17:R2.
    • (2013) Crit Care , vol.17
    • Zhang, Z.1    Xu, X.2    Ni, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.