메뉴 건너뛰기




Volumn 16, Issue 5, 2016, Pages 3202-3209

Gd(III)-Dithiolane Gold Nanoparticles for T1-Weighted Magnetic Resonance Imaging of the Pancreas

Author keywords

gold nanoparticles; magnetic resonance imaging; Pancreas

Indexed keywords

DIAGNOSIS; DISEASE CONTROL; FIBER OPTIC SENSORS; GOLD; GOLD COMPOUNDS; IMAGING TECHNIQUES; MAGNETISM; MEDICINE; METAL NANOPARTICLES; NANOMAGNETICS; NANOPARTICLES; RESONANCE; SYNTHESIS (CHEMICAL); TISSUE;

EID: 84974846049     PISSN: 15306984     EISSN: 15306992     Source Type: Journal    
DOI: 10.1021/acs.nanolett.6b00599     Document Type: Article
Times cited : (65)

References (38)
  • 1
    • 84871715774 scopus 로고    scopus 로고
    • Identifying people at a high risk of developing pancreatic cancer
    • Klein, A. P. Identifying people at a high risk of developing pancreatic cancer Nat. Rev. Cancer 2012, 13, 66-74 10.1038/nrc3420
    • (2012) Nat. Rev. Cancer , vol.13 , pp. 66-74
    • Klein, A.P.1
  • 2
    • 1542783526 scopus 로고    scopus 로고
    • The challenge of pancreatic cancer
    • Abbruzzese, J. The challenge of pancreatic cancer Int. J. Gastrointest. Cancer 2003, 33, 1-2 10.1385/IJGC:33:1:1
    • (2003) Int. J. Gastrointest. Cancer , vol.33 , pp. 1-2
    • Abbruzzese, J.1
  • 5
    • 53249135019 scopus 로고    scopus 로고
    • MRI Safety Update 2008: Part 1, MRI Contrast Agents and Nephrogenic Systemic Fibrosis AJR
    • Shellock, F. G.; Spinazzi, A. MRI Safety Update 2008: Part 1, MRI Contrast Agents and Nephrogenic Systemic Fibrosis AJR, Am. J. Roentgenol. 2008, 191, 1129-1139 10.2214/AJR.08.1038.1
    • (2008) Am. J. Roentgenol. , vol.191 , pp. 1129-1139
    • Shellock, F.G.1    Spinazzi, A.2
  • 6
    • 37549052096 scopus 로고    scopus 로고
    • Clinical advantages of 3.0 T MRI over 1.5 T
    • Willinek, W. A.; Schild, H. H. Clinical advantages of 3.0 T MRI over 1.5 T Eur. J. Radiol. 2008, 65, 2-14 10.1016/j.ejrad.2007.11.006
    • (2008) Eur. J. Radiol. , vol.65 , pp. 2-14
    • Willinek, W.A.1    Schild, H.H.2
  • 9
    • 79961050724 scopus 로고    scopus 로고
    • A Steroid-Conjugated Magnetic Resonance Probe Enhances Contrast in Progesterone Receptor Expressing Organs and Tumors in Vivo
    • Sukerkar, P. A.; MacRenaris, K. W.; Meade, T. J.; Burdette, J. E. A Steroid-Conjugated Magnetic Resonance Probe Enhances Contrast in Progesterone Receptor Expressing Organs and Tumors in Vivo Mol. Pharmaceutics 2011, 8, 1390-1400 10.1021/mp200219e
    • (2011) Mol. Pharmaceutics , vol.8 , pp. 1390-1400
    • Sukerkar, P.A.1    MacRenaris, K.W.2    Meade, T.J.3    Burdette, J.E.4
  • 12
    • 84925666594 scopus 로고    scopus 로고
    • High Relaxivity Gd(III)-DNA Gold Nanostars: Investigation of Shape Effects on Proton Relaxation
    • Rotz, M. W.; Culver, K. S. B.; Parigi, G.; MacRenaris, K. W.; Luchinat, C.; Odom, T. W.; Meade, T. J. High Relaxivity Gd(III)-DNA Gold Nanostars: Investigation of Shape Effects on Proton Relaxation ACS Nano 2015, 9, 3385-3396 10.1021/nn5070953
    • (2015) ACS Nano , vol.9 , pp. 3385-3396
    • Rotz, M.W.1    Culver, K.S.B.2    Parigi, G.3    MacRenaris, K.W.4    Luchinat, C.5    Odom, T.W.6    Meade, T.J.7
  • 13
    • 70449562074 scopus 로고    scopus 로고
    • Multimodal Gadolinium-Enriched DNA-Gold Nanoparticle Conjugates for Cellular Imaging
    • Song, Y.; Xu, X.; MacRenaris, K. W.; Zhang, X.-Q.; Mirkin, C. A.; Meade, T. J. Multimodal Gadolinium-Enriched DNA-Gold Nanoparticle Conjugates for Cellular Imaging Angew. Chem., Int. Ed. 2009, 48, 9143-9147 10.1002/anie.200904666
    • (2009) Angew. Chem., Int. Ed. , vol.48 , pp. 9143-9147
    • Song, Y.1    Xu, X.2    MacRenaris, K.W.3    Zhang, X.-Q.4    Mirkin, C.A.5    Meade, T.J.6
  • 15
    • 55549111554 scopus 로고    scopus 로고
    • Gold nanoparticles functionalised by Gd-complex of DTPA-bis(amide) conjugate of glutathione as an MRI contrast agent
    • Park, J.-A.; Reddy, P. A. N.; Kim, H.-K.; Kim, I.-S.; Kim, G.-C.; Chang, Y.; Kim, T.-J. Gold nanoparticles functionalised by Gd-complex of DTPA-bis(amide) conjugate of glutathione as an MRI contrast agent Bioorg. Med. Chem. Lett. 2008, 18, 6135-6137 10.1016/j.bmcl.2008.10.017
    • (2008) Bioorg. Med. Chem. Lett. , vol.18 , pp. 6135-6137
    • Park, J.-A.1    Reddy, P.A.N.2    Kim, H.-K.3    Kim, I.-S.4    Kim, G.-C.5    Chang, Y.6    Kim, T.-J.7
  • 17
    • 84885332178 scopus 로고    scopus 로고
    • Sugar/gadolinium-loaded gold nanoparticles for labelling and imaging cells by magnetic resonance imaging
    • Irure, A.; Marradi, M.; Arnaiz, B.; Genicio, N.; Padro, D.; Penades, S. Sugar/gadolinium-loaded gold nanoparticles for labelling and imaging cells by magnetic resonance imaging Biomater. Sci. 2013, 1, 658-668 10.1039/c3bm60032g
    • (2013) Biomater. Sci. , vol.1 , pp. 658-668
    • Irure, A.1    Marradi, M.2    Arnaiz, B.3    Genicio, N.4    Padro, D.5    Penades, S.6
  • 19
    • 84901616751 scopus 로고    scopus 로고
    • Lanthanide-coated gold nanoparticles for biomedical applications
    • Lewis, D. J.; Pikramenou, Z. Lanthanide-coated gold nanoparticles for biomedical applications Coord. Chem. Rev. 2014, 273-274, 213-225 10.1016/j.ccr.2014.03.019
    • (2014) Coord. Chem. Rev. , vol.273-274 , pp. 213-225
    • Lewis, D.J.1    Pikramenou, Z.2
  • 20
    • 84906819162 scopus 로고    scopus 로고
    • Lipid-AuNPs@PDA Nanohybrid for MRI/CT Imaging and Photothermal Therapy of Hepatocellular Carcinoma
    • Zeng, Y.; Zhang, D.; Wu, M.; Liu, Y.; Zhang, X.; Li, L.; Li, Z.; Han, X.; Wei, X.; Liu, X. Lipid-AuNPs@PDA Nanohybrid for MRI/CT Imaging and Photothermal Therapy of Hepatocellular Carcinoma ACS Appl. Mater. Interfaces 2014, 6, 14266-14277 10.1021/am503583s
    • (2014) ACS Appl. Mater. Interfaces , vol.6 , pp. 14266-14277
    • Zeng, Y.1    Zhang, D.2    Wu, M.3    Liu, Y.4    Zhang, X.5    Li, L.6    Li, Z.7    Han, X.8    Wei, X.9    Liu, X.10
  • 23
    • 18044387790 scopus 로고    scopus 로고
    • Chemistry and Properties of Nanocrystals of Different Shapes
    • Burda, C.; Chen, X.; Narayanan, R.; El-Sayed, M. A. Chemistry and Properties of Nanocrystals of Different Shapes Chem. Rev. 2005, 105, 1025-1102 10.1021/cr030063a
    • (2005) Chem. Rev. , vol.105 , pp. 1025-1102
    • Burda, C.1    Chen, X.2    Narayanan, R.3    El-Sayed, M.A.4
  • 24
    • 0041522419 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the pancreas and pancreatic tumors in a mouse orthotopic model of human cancer
    • Grimm, J.; Potthast, A.; Wunder, A.; Moore, A. Magnetic resonance imaging of the pancreas and pancreatic tumors in a mouse orthotopic model of human cancer Int. J. Cancer 2003, 106, 806-811 10.1002/ijc.11281
    • (2003) Int. J. Cancer , vol.106 , pp. 806-811
    • Grimm, J.1    Potthast, A.2    Wunder, A.3    Moore, A.4
  • 27
    • 34249874331 scopus 로고    scopus 로고
    • Diffusion-Weighted MRI in the Body: Applications and Challenges in Oncology AJR
    • Koh, D.-M.; Collins, D. J. Diffusion-Weighted MRI in the Body: Applications and Challenges in Oncology AJR, Am. J. Roentgenol. 2007, 188, 1622-1635 10.2214/AJR.06.1403
    • (2007) Am. J. Roentgenol. , vol.188 , pp. 1622-1635
    • Koh, D.-M.1    Collins, D.J.2
  • 28
    • 76849117309 scopus 로고    scopus 로고
    • Fabrication of gold nanoparticles for targeted therapy in pancreatic cancer
    • Patra, C. R.; Bhattacharya, R.; Mukhopadhyay, D.; Mukherjee, P. Fabrication of gold nanoparticles for targeted therapy in pancreatic cancer Adv. Drug Delivery Rev. 2010, 62, 346-61 10.1016/j.addr.2009.11.007
    • (2010) Adv. Drug Delivery Rev. , vol.62 , pp. 346-361
    • Patra, C.R.1    Bhattacharya, R.2    Mukhopadhyay, D.3    Mukherjee, P.4
  • 30
    • 0037011067 scopus 로고    scopus 로고
    • Adhesion Molecule-dependent Mechanisms Regulate the Rate of Macrophage Clearance during the Resolution of Peritoneal Inflammation
    • Bellingan, G. J.; Xu, P.; Cooksley, H.; Cauldwell, H.; Shock, A.; Bottoms, S.; Haslett, C.; Mutsaers, S. E.; Laurent, G. J. Adhesion Molecule-dependent Mechanisms Regulate the Rate of Macrophage Clearance During the Resolution of Peritoneal Inflammation J. Exp. Med. 2002, 196, 1515-1521 10.1084/jem.20011794
    • (2002) J. Exp. Med. , vol.196 , pp. 1515-1521
    • Bellingan, G.J.1    Xu, P.2    Cooksley, H.3    Cauldwell, H.4    Shock, A.5    Bottoms, S.6    Haslett, C.7    Mutsaers, S.E.8    Laurent, G.J.9
  • 31
    • 33750143052 scopus 로고    scopus 로고
    • MRI of adenocarcinoma of the pancreas AJR
    • Miller, F. H.; Rini, N. J.; Keppke, A. L. MRI of adenocarcinoma of the pancreas AJR, Am. J. Roentgenol. 2006, 187, W365-74 10.2214/AJR.05.0875
    • (2006) Am. J. Roentgenol. , vol.187 , pp. W365-W374
    • Miller, F.H.1    Rini, N.J.2    Keppke, A.L.3
  • 33
    • 84875682931 scopus 로고    scopus 로고
    • Theranostic nanoparticles with controlled release of gemcitabine for targeted therapy and MRI of pancreatic cancer
    • Lee, G. Y.; Qian, W. P.; Wang, L.; Wang, Y. A.; Staley, C. A.; Satpathy, M.; Nie, S.; Mao, H.; Yang, L. Theranostic nanoparticles with controlled release of gemcitabine for targeted therapy and MRI of pancreatic cancer ACS Nano 2013, 7, 2078-89 10.1021/nn3043463
    • (2013) ACS Nano , vol.7 , pp. 2078-2089
    • Lee, G.Y.1    Qian, W.P.2    Wang, L.3    Wang, Y.A.4    Staley, C.A.5    Satpathy, M.6    Nie, S.7    Mao, H.8    Yang, L.9
  • 35
    • 84864396501 scopus 로고    scopus 로고
    • Pancreatic magnetic resonance imaging after manganese injection distinguishes type 2 diabetic and normoglycemic patients
    • Botsikas, D.; Terraz, S.; Vinet, L.; Lamprianou, S.; Becker, C. D.; Bosco, D.; Meda, P.; Montet, X. Pancreatic magnetic resonance imaging after manganese injection distinguishes type 2 diabetic and normoglycemic patients Islets 2012, 4, 243-8 10.4161/isl.20857
    • (2012) Islets , vol.4 , pp. 243-248
    • Botsikas, D.1    Terraz, S.2    Vinet, L.3    Lamprianou, S.4    Becker, C.D.5    Bosco, D.6    Meda, P.7    Montet, X.8
  • 36
    • 0032845722 scopus 로고    scopus 로고
    • MR imaging of pancreatic lesions. Comparison of manganese-DPDP and gadolinium chelate
    • Diehl, S. J.; Lehmann, K. J.; Gaa, J.; McGill, S.; Hoffmann, V.; Georgi, M. MR imaging of pancreatic lesions. Comparison of manganese-DPDP and gadolinium chelate Invest. Radiol. 1999, 34, 589-95 10.1097/00004424-199909000-00007
    • (1999) Invest. Radiol. , vol.34 , pp. 589-595
    • Diehl, S.J.1    Lehmann, K.J.2    Gaa, J.3    McGill, S.4    Hoffmann, V.5    Georgi, M.6
  • 37
    • 33846925354 scopus 로고    scopus 로고
    • MRI of the pancreas: Tumours and tumour-simulating processes
    • Schima, W. MRI of the pancreas: tumours and tumour-simulating processes Cancer Imaging 2006, 6, 199-203 10.1102/1470-7330.2006.0035
    • (2006) Cancer Imaging , vol.6 , pp. 199-203
    • Schima, W.1
  • 38
    • 27744434656 scopus 로고    scopus 로고
    • Suspected pancreatic cancer: Evaluation by dynamic gadolinium-enhanced 3D gradient-echo MRI AJR
    • Birchard, K. R.; Semelka, R. C.; Hyslop, W. B.; Brown, A.; Armao, D.; Firat, Z.; Vaidean, G. Suspected pancreatic cancer: evaluation by dynamic gadolinium-enhanced 3D gradient-echo MRI AJR, Am. J. Roentgenol. 2005, 185, 700-3 10.2214/ajr.185.3.01850700
    • (2005) Am. J. Roentgenol. , vol.185 , pp. 700-703
    • Birchard, K.R.1    Semelka, R.C.2    Hyslop, W.B.3    Brown, A.4    Armao, D.5    Firat, Z.6    Vaidean, G.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.