메뉴 건너뛰기




Volumn 247, Issue , 2016, Pages 125-135

Design and fabrication of novel multi-channel floating neural probes for intracortical chronic recording

Author keywords

Chronic recording; Cortex; Flexible ribbon cable; Floating implantation; Neural probe; PEDOT:PSS; Polyimide BPDA PPD

Indexed keywords

BIOCOMPATIBILITY; CABLES; CONDUCTING POLYMERS; ELECTRIC IMPEDANCE; ELECTRIC IMPEDANCE MEASUREMENT; ELECTRODES; ELECTROPHYSIOLOGY; FLAT CABLES; PLASTIC COATINGS; POLYIMIDES; SILICON; SILICON WAFERS; SPECTROSCOPY;

EID: 84973868626     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2016.05.034     Document Type: Article
Times cited : (33)

References (20)
  • 3
    • 2442716494 scopus 로고    scopus 로고
    • Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex
    • R.J. Vetter, J.C. Williams, J.F. Hetke, E.A. Nunamaker, and D.R. Kipke Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex IEEE Trans. Biomed. Eng. 51 2004 896 904
    • (2004) IEEE Trans. Biomed. Eng. , vol.51 , pp. 896-904
    • Vetter, R.J.1    Williams, J.C.2    Hetke, J.F.3    Nunamaker, E.A.4    Kipke, D.R.5
  • 9
    • 84893116769 scopus 로고    scopus 로고
    • Partially flexible MEMS neural probe composed of polyimide and sucrose gel for reducing brain damage during and after implantation
    • M. Jeon, J. Cho, Y.K. Kim, D. Jung, E.-S. Yoon, S. Shin, and Il-J. Cho Partially flexible MEMS neural probe composed of polyimide and sucrose gel for reducing brain damage during and after implantation J. Micromach. Microeng. 2014
    • (2014) J. Micromach. Microeng.
    • Jeon, M.1    Cho, J.2    Kim, Y.K.3    Jung, D.4    Yoon, E.-S.5    Shin, S.6    Cho, I.-J.7
  • 10
    • 85119218429 scopus 로고    scopus 로고
    • Flexible Silicon-Polymer Neural Probe Rigidified by Dissolvable Insertion Vehicle for High-Resolution Neural Recording with Improved Duration
    • F. Barz, P. Ruther, S. Takeuchi, O. Paul, Flexible Silicon-Polymer Neural Probe Rigidified by Dissolvable Insertion Vehicle for High-Resolution Neural Recording with Improved Duration, MEMS 215 Portugal.
    • MEMS 215 Portugal
    • Barz, F.1    Ruther, P.2    Takeuchi, S.3    Paul, O.4
  • 13
    • 77949497612 scopus 로고    scopus 로고
    • Characterization of parylene C as an encapsulation material for implanted neural prostheses
    • C. Hassler, R.P. von Metzen, P. Ruther, and T. Stieglitz Characterization of parylene C as an encapsulation material for implanted neural prostheses J. Biomed. Mater. Res. 93B 2010 266 274
    • (2010) J. Biomed. Mater. Res. , vol.93 B , pp. 266-274
    • Hassler, C.1    Von Metzen, R.P.2    Ruther, P.3    Stieglitz, T.4
  • 14
    • 84955505578 scopus 로고    scopus 로고
    • Design and fabrication of multi-contact flexible silicon probes for intracortical floating implantation
    • USA
    • A. Schander, E. Tolstosheeva, V. Biefeld, L. Kempen, H. Stemmann, A. Kreiter, and W. Lang Design and fabrication of multi-contact flexible silicon probes for intracortical floating implantation Transducers USA 2015 1739 1742
    • (2015) Transducers , pp. 1739-1742
    • Schander, A.1    Tolstosheeva, E.2    Biefeld, V.3    Kempen, L.4    Stemmann, H.5    Kreiter, A.6    Lang, W.7
  • 15
    • 84985031439 scopus 로고    scopus 로고
    • Accelerated soak performance of BPDA-PPD PI for implantable MEAs
    • Germany
    • E. Tolstosheeva, V. Biefeld, and W. Lang Accelerated soak performance of BPDA-PPD PI for implantable MEAs Proceedings Eurosensors Germany 2015
    • (2015) Proceedings Eurosensors
    • Tolstosheeva, E.1    Biefeld, V.2    Lang, W.3
  • 16
    • 50249084472 scopus 로고    scopus 로고
    • Neural stimulation and recording electrodes
    • S.F. Cogan Neural stimulation and recording electrodes Annu. Rev. Biomed. Eng. 2008 275 309
    • (2008) Annu. Rev. Biomed. Eng. , pp. 275-309
    • Cogan, S.F.1
  • 17
    • 33745905893 scopus 로고
    • Stress-related problems in silicon technology
    • S.M. Hu Stress-related problems in silicon technology J. Appl. Phys. 70 1991
    • (1991) J. Appl. Phys. , vol.70
    • Hu, S.M.1
  • 19
    • 84875111406 scopus 로고    scopus 로고
    • Effect of experimental factors on the properties of PEDOT-NaPSS galvanostatically deposited from an aqueous micellar media for invasive electrodes
    • R. Starbird, W. Bauhofer, M. Meza-Cuevas, and W.H. Krautschneider Effect of experimental factors on the properties of PEDOT-NaPSS galvanostatically deposited from an aqueous micellar media for invasive electrodes Biomedical Engineering International Conference 2012
    • (2012) Biomedical Engineering International Conference
    • Starbird, R.1    Bauhofer, W.2    Meza-Cuevas, M.3    Krautschneider, W.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.