Volumn 46, Issue , 2015, Pages S129-S134

One year orthopaedic trauma experience using an advanced interdisciplinary hybrid operating room

Author keywords

3D imaging; computer assisted surgery; hybrid operating room; intraoperative imaging; navigation

Indexed keywords

ACETABULUM FRACTURE; ADULT; ARTICLE; BONE SCREW; CASE REPORT; CAUDAL SCREW DISLOCATION; CERVICAL SPINE FRACTURE; CHILD; COLLAPSE; COMPUTER ASSISTED TOMOGRAPHY; DEBRIDEMENT; DYSPHAGIA; EMERGENCY HEALTH SERVICE; FALLING; FEMALE; FIRST CERVICAL VERTEBRA; FLUOROSCOPY; FRACTURE REDUCTION; HUMAN; HYBRID OPERATING ROOM; INTRAOPERATIVE PERIOD; KYPHOPLASTY; MALE; MEDICAL DEVICE COMPLICATION; MIDDLE AGED; MOTOR VEHICLE; NEUROLOGIC DISEASE; OPERATING ROOM; OPERATIVE BLOOD LOSS; ORTHOPEDIC IMPLANT; ORTHOPEDIC SURGERY; OSTEOSYNTHESIS; PATIENT SAFETY; PELVIS FRACTURE; PEROPERATIVE COMPLICATION; POSTOPERATIVE CARE; POSTOPERATIVE COMPLICATION; POSTOPERATIVE INFECTION; PRIORITY JOURNAL; SACRAL FRACTURE; SCHOOL CHILD; SEROMA; SPINAL ANGIOGRAPHY; THREE DIMENSIONAL IMAGING; X RAY; COMPUTER ASSISTED SURGERY; EDUCATION; GERMANY; INTERDISCIPLINARY COMMUNICATION; MINIMALLY INVASIVE SURGERY; ORGANIZATION AND MANAGEMENT; PATIENT CARE; SURGICAL EQUIPMENT; TRENDS;

EID: 84970923547     PISSN: 00201383     EISSN: 18790267     Source Type: Journal    
DOI: 10.1016/S0020-1383(15)30032-2     Document Type: Article
Times cited : (37)

References (27)
  • 1
    • 84863731666 scopus 로고    scopus 로고
    • The hybrid operating room. Home of high-end intraoperative imaging
    • Gebhard F, Riepl C, Richter P. The hybrid operating room. Home of high-end intraoperative imaging. Unfallchirurg 2012;115(2):107-20.
    • (2012) Unfallchirurg , vol.115 , Issue.2 , pp. 107-120
    • Gebhard, F.1    Riepl, C.2    Richter, P.3
  • 2
    • 84861098421 scopus 로고    scopus 로고
    • Minimally invasive heart valve surgery: How and why in 2012
    • Suri RM, Thalji NM. Minimally invasive heart valve surgery: how and why in 2012. Curr Cardiol Rep 2012;14(2):171-9.
    • (2012) Curr Cardiol Rep , vol.14 , Issue.2 , pp. 171-179
    • Suri, R.M.1    Thalji, N.M.2
  • 3
    • 84884371375 scopus 로고    scopus 로고
    • Flexion-distraction injuries of the thoracolumbar spine: Open fusion versus percutaneous pedicle screw fixation
    • Grossbach AJ, Dahdaleh NS, Abel TJ, Woods GD, Dlouhy BJ, Hitchon PW. Flexion-distraction injuries of the thoracolumbar spine: open fusion versus percutaneous pedicle screw fixation. Neurosurg Focus 2013;35(2):E2.
    • (2013) Neurosurg Focus , vol.35 , Issue.2 , pp. E2
    • Grossbach, A.J.1    Dahdaleh, N.S.2    Abel, T.J.3    Woods, G.D.4    Dlouhy, B.J.5    Hitchon, P.W.6
  • 4
    • 84886719101 scopus 로고    scopus 로고
    • Hybrid operating rooms: Only for advanced endovascular procedures?
    • Verhoeven E1, Katsargyris A, Töpel I. Hybrid operating rooms: only for advanced endovascular procedures? Zentralbl Chir 2013;138(5):516-20.
    • (2013) Zentralbl Chir , vol.138 , Issue.5 , pp. 516-520
    • Verhoeven, E.1    Katsargyris, A.2    Töpel, I.3
  • 5
    • 84872729381 scopus 로고    scopus 로고
    • Hybrid operating room concept for combined diagnostics, intervention and surgery in acute type A dissection
    • Tsagakis K, Konorza T, Dohle DS, Kottenberg E, Buck T, Thielmann M, et al. Hybrid operating room concept for combined diagnostics, intervention and surgery in acute type A dissection. Eur J Cardiothorac Surg 2013;43(2):397-404.
    • (2013) Eur J Cardiothorac Surg , vol.43 , Issue.2 , pp. 397-404
    • Tsagakis, K.1    Konorza, T.2    Dohle, D.S.3    Kottenberg, E.4    Buck, T.5    Thielmann, M.6
  • 6
    • 84863740962 scopus 로고    scopus 로고
    • Intraoperative magnetic resonance imaging. Fifteen years' experience in the neurosurgical hybrid operating room
    • Hlavac M, König R, Halatsch M, Wirtz CR. Intraoperative magnetic resonance imaging. Fifteen years' experience in the neurosurgical hybrid operating room. Unfallchirurg 2012;115(2):121-4.
    • (2012) Unfallchirurg , vol.115 , Issue.2 , pp. 121-124
    • Hlavac, M.1    König, R.2    Halatsch, M.3    Wirtz, C.R.4
  • 8
    • 84889066655 scopus 로고    scopus 로고
    • Hybrid operating room for the treatment of complex neurovascular and brachiocephalic lesions
    • Iihara K, Satow T, Matsushige T, Kataoka H, Nakajima N, Fukuda K et al. Hybrid operating room for the treatment of complex neurovascular and brachiocephalic lesions. J Stroke Cerebrovasc Dis 2013;22(8):e277-85.
    • (2013) J Stroke Cerebrovasc Dis , vol.22 , Issue.8 , pp. e277-e285
    • Iihara, K.1    Satow, T.2    Matsushige, T.3    Kataoka, H.4    Nakajima, N.5    Fukuda, K.6
  • 9
    • 84879551629 scopus 로고    scopus 로고
    • Do we need hybrid operating theaters?: A critical appraisal
    • Wohlgemuth WA. Do we need hybrid operating theaters?: a critical appraisal. Radiologe 2013;53(6):531-4.
    • (2013) Radiologe , vol.53 , Issue.6 , pp. 531-534
    • Wohlgemuth, W.A.1
  • 10
    • 67649791453 scopus 로고    scopus 로고
    • Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure
    • Zwingmann J, Konrad G, Kotter E, Südkamp NP, Oberst M. Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure. Clin Orthop Relat Res 2009;467(7):1833-8.
    • (2009) Clin Orthop Relat Res , vol.467 , Issue.7 , pp. 1833-1838
    • Zwingmann, J.1    Konrad, G.2    Kotter, E.3    Südkamp, N.P.4    Oberst, M.5
  • 11
    • 77955574857 scopus 로고    scopus 로고
    • Can computer-assisted surgery reduce the effective dose for spinal fusion and sacroiliac screw insertion?
    • Kraus MD, Krischak G, Keppler P, Gebhard FT, Schuetz UH. Can computer-assisted surgery reduce the effective dose for spinal fusion and sacroiliac screw insertion? Clin Orthop Relat Res 2010;468:2419-29.
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 2419-2429
    • Kraus, M.D.1    Krischak, G.2    Keppler, P.3    Gebhard, F.T.4    Schuetz, U.H.5
  • 12
    • 84930380978 scopus 로고    scopus 로고
    • Application of 3D printed customized external fixator in fracture reduction
    • Qiao F, Li D, Jin Z, Gao Y, Zhou T, He J, Cheng. Application of 3D printed customized external fixator in fracture reduction. Injury 2015;46(6):1150-5.
    • (2015) Injury , vol.46 , Issue.6 , pp. 1150-1155
    • Qiao, F.1    Li, D.2    Jin, Z.3    Gao, Y.4    Zhou, T.5    He, J.6    Cheng7
  • 13
    • 84930381406 scopus 로고    scopus 로고
    • Fluoroscopically assisted computer navigation enables accurate percutaneous screw placement for pelvic and acetabular fracture fixation
    • Wong JM, Bewsher S, Yew J, Bucknill A, de Steiger R. Fluoroscopically assisted computer navigation enables accurate percutaneous screw placement for pelvic and acetabular fracture fixation. Injury 2015;46(6):1064-8.
    • (2015) Injury , vol.46 , Issue.6 , pp. 1064-1068
    • Wong, J.M.1    Bewsher, S.2    Yew, J.3    Bucknill, A.4    De Steiger, R.5
  • 14
    • 84922509137 scopus 로고    scopus 로고
    • Radiological outcome and intraoperative evaluation of a computer-navigation system for femoral nailing: A retrospective cohort study
    • Hawi N, Liodakis E, Suero EM, Stuebig T, Citak M, Krettek C. Radiological outcome and intraoperative evaluation of a computer-navigation system for femoral nailing: a retrospective cohort study. Injury 2014;45(10):1632-6.
    • (2014) Injury , vol.45 , Issue.10 , pp. 1632-1636
    • Hawi, N.1    Liodakis, E.2    Suero, E.M.3    Stuebig, T.4    Citak, M.5    Krettek, C.6
  • 15
    • 84898832152 scopus 로고    scopus 로고
    • Iliosacral screw insertion using CT-3D-fluoroscopy matching navigation
    • Takao M, Nishii T, Sakai T, Yoshikawa H, Sugano N. Iliosacral screw insertion using CT-3D-fluoroscopy matching navigation. Injury 2014;45(6):988-94.
    • (2014) Injury , vol.45 , Issue.6 , pp. 988-994
    • Takao, M.1    Nishii, T.2    Sakai, T.3    Yoshikawa, H.4    Sugano, N.5
  • 16
    • 80052564997 scopus 로고    scopus 로고
    • Pedicle screw insertion accuracy with different assisted methods: A systematic review and meta-analysis of comparative studies
    • Tian NF, Huang QS, Zhou P, Zhou Y, Wu RK, Lou Y, Xu HZ. Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies. Eur Spine J 2011;20:846-59.
    • (2011) Eur Spine J , vol.20 , pp. 846-859
    • Tian, N.F.1    Huang, Q.S.2    Zhou, P.3    Zhou, Y.4    Wu, R.K.5    Lou, Y.6    Xu, H.Z.7
  • 17
    • 68349104323 scopus 로고    scopus 로고
    • Image-guided pedicle screw insertion accuracy: A meta-analysis
    • Tian NF, Xu HZ. Image-guided pedicle screw insertion accuracy: a meta-analysis. Int Orthop 2009;33:895-903.
    • (2009) Int Orthop , vol.33 , pp. 895-903
    • Tian, N.F.1    Xu, H.Z.2
  • 18
    • 33846683025 scopus 로고    scopus 로고
    • Pedicle screw placement accuracy: A meta-analysis
    • Kosmopoulos V, Schizas C. Pedicle screw placement accuracy: a meta-analysis. Spine 2007;32:E111-E120.
    • (2007) Spine , vol.32 , pp. E111-E120
    • Kosmopoulos, V.1    Schizas, C.2
  • 19
    • 77951143798 scopus 로고    scopus 로고
    • Functional outcome of computer-assisted spinal pedicle screw placement: A systematic review and meta-analysis of 23 studies including 5, 992 pedicle screws
    • Verma R, Krishan S, Haendlmayer K, Mohsen A. Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5, 992 pedicle screws. Eur Spine J. 2010; 19:370-375.
    • (2010) Eur Spine J. , vol.19 , pp. 370-375
    • Verma, R.1    Krishan, S.2    Haendlmayer, K.3    Mohsen, A.4
  • 20
    • 84864559463 scopus 로고    scopus 로고
    • Pedicle screw navigation: A systematic review and meta-analysis of perforation risk for computer-navigated versus freehand insertion
    • Shin BJ, James AR, Njoku IU, Härtl R. Pedicle screw navigation: a systematic review and meta-analysis of perforation risk for computer-navigated versus freehand insertion. J Neurosurg Spine 2012;17:113-22.
    • (2012) J Neurosurg Spine , vol.17 , pp. 113-122
    • Shin, B.J.1    James, A.R.2    Njoku, I.U.3    Härtl, R.4
  • 21
    • 84856726223 scopus 로고    scopus 로고
    • Pediatric pedicle screw placement using intraoperative computed tomography and 3-dimensional image-guided navigation
    • Larson AN, Santos ER, Polly DW Jr, Ledonio CG, Sembrano JN, Mielke CH, Guidera KJ. Pediatric pedicle screw placement using intraoperative computed tomography and 3-dimensional image-guided navigation. Spine 2012;37:E188-E194.
    • (2012) Spine , vol.37 , pp. E188-E194
    • Larson, A.N.1    Santos, E.R.2    Polly, D.W.3    Ledonio, C.G.4    Sembrano, J.N.5    Mielke, C.H.6    Guidera, K.J.7
  • 22
    • 84895089652 scopus 로고    scopus 로고
    • Routine spinal navigation for thoraco-lumbar pedicle screw insertion using the O-arm three-dimensional imaging system improves placement accuracy
    • Ling JM, Dinesh SK, Pang BC, Chen MW, Lim HL, Louange DT, et al. Routine spinal navigation for thoraco-lumbar pedicle screw insertion using the O-arm three-dimensional imaging system improves placement accuracy. J Clin Neurosci 2013;21:493-8.
    • (2013) J Clin Neurosci , vol.21 , pp. 493-498
    • Ling, J.M.1    Dinesh, S.K.2    Pang, B.C.3    Chen, M.W.4    Lim, H.L.5    Louange, D.T.6
  • 23
    • 2542497793 scopus 로고    scopus 로고
    • Computer-guidance in percutaneous screw stabilization of the iliosacral joint
    • Arand M, Kinzl L, Gebhard F. Computer-guidance in percutaneous screw stabilization of the iliosacral joint. Clin Orthop Relt Res 2004;(422):201-7.
    • (2004) Clin Orthop Relt Res , Issue.422 , pp. 201-207
    • Arand, M.1    Kinzl, L.2    Gebhard, F.3
  • 24
    • 84875157365 scopus 로고    scopus 로고
    • Computer-assisted planning and navigation improves cutting accuracy during simulated bone tumor surgery of the pelvis
    • Cartiaux O, Banse X, Paul L, Francq BG, Aubin CÉ, Docquier PL. Computer-assisted planning and navigation improves cutting accuracy during simulated bone tumor surgery of the pelvis. Comput Aided Surg 2013;18(1-2): 19-26.
    • (2013) Comput Aided Surg , vol.18 , Issue.1-2 , pp. 19-26
    • Cartiaux, O.1    Banse, X.2    Paul, L.3    Francq, B.G.4    Aubin, C.É.5    Docquier, P.L.6
  • 25
    • 84867312693 scopus 로고    scopus 로고
    • The outcomes of navigation-assisted bone tumour surgery
    • Cho HS, Oh JH, Han I, Kim HS. The outcomes of navigation-assisted bone tumour surgery. J Bone Joint Surg Br 2012;94(10):1414-20.
    • (2012) J Bone Joint Surg Br , vol.94 , Issue.10 , pp. 1414-1420
    • Cho, H.S.1    Oh, J.H.2    Han, I.3    Kim, H.S.4
  • 26
    • 84885458737 scopus 로고    scopus 로고
    • Can computer navigation-assisted surgery reduce the risk of an intralesional margin and reduce the rate of local recurrence in patients with a tumour of the pelvis or sacrum?
    • Jeys L, Matharu GS, Nandra RS, Grimer RJ. Can computer navigation-assisted surgery reduce the risk of an intralesional margin and reduce the rate of local recurrence in patients with a tumour of the pelvis or sacrum? Bone Joint J 2013;95B(10):1417-24.
    • (2013) Bone Joint J , vol.95 B , Issue.10 , pp. 1417-1424
    • Jeys, L.1    Matharu, G.S.2    Nandra, R.S.3    Grimer, R.J.4
  • 27
    • 84890572434 scopus 로고    scopus 로고
    • The interdisciplinary hybrid operation theatre: Current experience and future
    • Richter PH, Gebhard F. The interdisciplinary hybrid operation theatre: Current experience and future. Der Chirurg 2013;84(12):1036-40.
    • (2013) Der Chirurg , vol.84 , Issue.12 , pp. 1036-1040
    • Richter, P.H.1    Gebhard, F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.