메뉴 건너뛰기




Volumn 45, Issue 6, 2014, Pages 988-994

Iliosacral screw insertion using CT-3D-fluoroscopy matching navigation

Author keywords

3D fluoroscopy; CT based plan; Iliosacral screw; Navigation

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; BONE PIN; BONE SCREW; CADAVER; CLINICAL ARTICLE; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; FLUOROSCOPY; GUIDE WIRE; HUMAN; ILIOSACRAL SCREW; IMAGING SOFTWARE; MALE; MEASUREMENT ERROR; MIDDLE AGED; NERVE ROOT; PATIENT SAFETY; PELVIS FRACTURE; PERCUTANEOUS ILIOSACRAL SCREW INSERTION; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; RELIABILITY; SIMULATION; SURGEON; SURGICAL NAVIGATION SYSTEM; SURGICAL TECHNIQUE; THREE DIMENSIONAL IMAGING; VERTEBRA BODY; CLINICAL COMPETENCE; COMPUTER ASSISTED SURGERY; DEVICES; DISLOCATIONS; EVALUATION STUDY; FRACTURES, BONE; ILIAC BONE; INJURIES; OSTEOSYNTHESIS; PATHOLOGY; PROCEDURES; RADIOGRAPHY; REPRODUCIBILITY; SACRUM; SENSITIVITY AND SPECIFICITY; TREATMENT OUTCOME;

EID: 84898832152     PISSN: 00201383     EISSN: 18790267     Source Type: Journal    
DOI: 10.1016/j.injury.2014.01.015     Document Type: Article
Times cited : (58)

References (31)
  • 1
    • 0029314802 scopus 로고
    • Early results of percutaneous iliosacral screws placed with the patient in the supine position
    • M.L. Routt Jr., P.J. Kregor, P.T. Simonian, and K.A. Mayo Early results of percutaneous iliosacral screws placed with the patient in the supine position J Orthop Trauma 9 1995 207 214
    • (1995) J Orthop Trauma , vol.9 , pp. 207-214
    • Routt, Jr.M.L.1    Kregor, P.J.2    Simonian, P.T.3    Mayo, K.A.4
  • 2
    • 0028912061 scopus 로고
    • Percutaneous iliosacral screw fixation: Early treatment for unstable posterior pelvic ring disruptions
    • T.E. Shuler, D.C. Boone, G.S. Gruen, and A.B. Peitzman Percutaneous iliosacral screw fixation: early treatment for unstable posterior pelvic ring disruptions J Trauma 38 1995 453 458
    • (1995) J Trauma , vol.38 , pp. 453-458
    • Shuler, T.E.1    Boone, D.C.2    Gruen, G.S.3    Peitzman, A.B.4
  • 4
    • 33846949699 scopus 로고    scopus 로고
    • Fluoroscopic imaging guides of the posterior pelvis pertaining to iliosacral screw placement
    • discussion 56
    • B.H. Ziran, A.D. Wasan, D.M. Marks, S.A. Olson, and M.W. Chapman Fluoroscopic imaging guides of the posterior pelvis pertaining to iliosacral screw placement J Trauma 62 2007 347 356 discussion 56
    • (2007) J Trauma , vol.62 , pp. 347-356
    • Ziran, B.H.1    Wasan, A.D.2    Marks, D.M.3    Olson, S.A.4    Chapman, M.W.5
  • 5
    • 14844336330 scopus 로고    scopus 로고
    • Inadvertent intraforaminal iliosacral screw placement despite apparent appropriate positioning on intraoperative fluoroscopy
    • H.C. Sagi, and E.M. Lindvall Inadvertent intraforaminal iliosacral screw placement despite apparent appropriate positioning on intraoperative fluoroscopy J Orthop Trauma 19 2005 130 133
    • (2005) J Orthop Trauma , vol.19 , pp. 130-133
    • Sagi, H.C.1    Lindvall, E.M.2
  • 6
    • 0036633039 scopus 로고    scopus 로고
    • Fluoroscopic positioning of sacroiliac screws in 88 patients
    • E.W. van den Bosch, C.M. van Zwienen, and A.B. van Vugt Fluoroscopic positioning of sacroiliac screws in 88 patients J Trauma 53 2002 44 48
    • (2002) J Trauma , vol.53 , pp. 44-48
    • Van Den Bosch, E.W.1    Van Zwienen, C.M.2    Van Vugt, A.B.3
  • 7
    • 67649791453 scopus 로고    scopus 로고
    • Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure
    • J. Zwingmann, G. Konrad, E. Kotter, N.P. Sudkamp, and M. Oberst Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure Clin Orthop Relat Res 467 2009 1833 1838
    • (2009) Clin Orthop Relat Res , vol.467 , pp. 1833-1838
    • Zwingmann, J.1    Konrad, G.2    Kotter, E.3    Sudkamp, N.P.4    Oberst, M.5
  • 8
    • 78650847385 scopus 로고    scopus 로고
    • Percutaneous iliosacral screw insertion: Malpositioning and revision rate of screws with regards to application technique (navigated vs conventional)
    • J. Zwingmann, G. Konrad, A.T. Mehlhorn, N.P. Sudkamp, and M. Oberst Percutaneous iliosacral screw insertion: malpositioning and revision rate of screws with regards to application technique (navigated vs. conventional) J Trauma 69 2010 1501 1506
    • (2010) J Trauma , vol.69 , pp. 1501-1506
    • Zwingmann, J.1    Konrad, G.2    Mehlhorn, A.T.3    Sudkamp, N.P.4    Oberst, M.5
  • 9
    • 0031266643 scopus 로고    scopus 로고
    • Iliosacral screw fixation: Early complications of the percutaneous technique
    • M.L. Routt Jr., P.T. Simonian, and W.J. Mills Iliosacral screw fixation: early complications of the percutaneous technique J Orthop Trauma 11 1997 584 589
    • (1997) J Orthop Trauma , vol.11 , pp. 584-589
    • Routt, Jr.M.L.1    Simonian, P.T.2    Mills, W.J.3
  • 13
    • 17644405424 scopus 로고    scopus 로고
    • Standard multiplanar fluoroscopy versus a fluoroscopically based navigation system for the percutaneous insertion of iliosacral screws: A cadaver model
    • C. Collinge, D. Coons, P. Tornetta, and J. Aschenbrenner Standard multiplanar fluoroscopy versus a fluoroscopically based navigation system for the percutaneous insertion of iliosacral screws: a cadaver model J Orthop Trauma 19 2005 254 258
    • (2005) J Orthop Trauma , vol.19 , pp. 254-258
    • Collinge, C.1    Coons, D.2    Tornetta, P.3    Aschenbrenner, J.4
  • 14
    • 0036172601 scopus 로고    scopus 로고
    • Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws
    • A.F. Hinsche, P.V. Giannoudis, and R.M. Smith Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws Clin Orthop Relat Res 395 2002 135 144
    • (2002) Clin Orthop Relat Res , vol.395 , pp. 135-144
    • Hinsche, A.F.1    Giannoudis, P.V.2    Smith, R.M.3
  • 15
    • 33745048496 scopus 로고    scopus 로고
    • Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: Results of a controlled experimental investigation
    • D. Briem, W. Linhart, W. Lehmann, P.G. Begemann, G. Adam, and U. Schumacher et al. Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation Eur Spine J 15 2006 757 763
    • (2006) Eur Spine J , vol.15 , pp. 757-763
    • Briem, D.1    Linhart, W.2    Lehmann, W.3    Begemann, P.G.4    Adam, G.5    Schumacher, U.6
  • 16
    • 84864367875 scopus 로고    scopus 로고
    • Screw placement for acetabular fractures: Which navigation modality (2-dimensional vs. 3-dimensional) should be used? An experimental study
    • F. Gras, I. Marintschev, K. Klos, T. Muckley, G.O. Hofmann, and D.M. Kahler Screw placement for acetabular fractures: which navigation modality (2-dimensional vs. 3-dimensional) should be used? An experimental study J Orthop Trauma 26 2012 466 473
    • (2012) J Orthop Trauma , vol.26 , pp. 466-473
    • Gras, F.1    Marintschev, I.2    Klos, K.3    Muckley, T.4    Hofmann, G.O.5    Kahler, D.M.6
  • 17
    • 78149362122 scopus 로고    scopus 로고
    • Computer-assisted periacetabular screw placement: Comparison of different fluoroscopy-based navigation procedures with conventional technique
    • B.G. Ochs, C. Gonser, T. Shiozawa, A. Badke, K. Weise, and B. Rolauffs et al. Computer-assisted periacetabular screw placement: comparison of different fluoroscopy-based navigation procedures with conventional technique Injury 41 2010 1297 1305
    • (2010) Injury , vol.41 , pp. 1297-1305
    • Ochs, B.G.1    Gonser, C.2    Shiozawa, T.3    Badke, A.4    Weise, K.5    Rolauffs, B.6
  • 18
    • 30944447863 scopus 로고    scopus 로고
    • An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws
    • H.E. Smith, P.S. Yuan, R. Sasso, S. Papadopolous, and A.R. Vaccaro An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws Spine (Phila Pa 1976) 31 2006 234 238
    • (2006) Spine (Phila Pa 1976) , vol.31 , pp. 234-238
    • Smith, H.E.1    Yuan, P.S.2    Sasso, R.3    Papadopolous, S.4    Vaccaro, A.R.5
  • 19
    • 85119385392 scopus 로고    scopus 로고
    • Computer-guidance in percutaneous screw stabilization of the iliosacral joint
    • M. Arand, L. Kinzl, and F. Gebhard Computer-guidance in percutaneous screw stabilization of the iliosacral joint Clin Orthop Relat Res 20 2004 1 7
    • (2004) Clin Orthop Relat Res , vol.20 , pp. 1-7
    • Arand, M.1    Kinzl, L.2    Gebhard, F.3
  • 20
    • 80054041768 scopus 로고    scopus 로고
    • Computer-assisted surgery and intraoperative three-dimensional imaging for screw placement in different pelvic regions
    • L. Grossterlinden, J. Nuechtern, P.G. Begemann, I. Fuhrhop, J.P. Petersen, and A. Ruecker et al. Computer-assisted surgery and intraoperative three-dimensional imaging for screw placement in different pelvic regions J Trauma 71 2011 926 932
    • (2011) J Trauma , vol.71 , pp. 926-932
    • Grossterlinden, L.1    Nuechtern, J.2    Begemann, P.G.3    Fuhrhop, I.4    Petersen, J.P.5    Ruecker, A.6
  • 21
    • 80051882142 scopus 로고    scopus 로고
    • Accuracy of a 3D fluoroscopic navigation system using a flat-panel detector-equipped C-arm
    • M. Takao, K. Yabuta, T. Nishii, T. Sakai, and N. Sugano Accuracy of a 3D fluoroscopic navigation system using a flat-panel detector-equipped C-arm Comput Aided Surg 16 2011 234 239
    • (2011) Comput Aided Surg , vol.16 , pp. 234-239
    • Takao, M.1    Yabuta, K.2    Nishii, T.3    Sakai, T.4    Sugano, N.5
  • 22
    • 84857345190 scopus 로고    scopus 로고
    • Application of a CT-3D fluoroscopy matching navigation system to the pelvic and femoral regions
    • M. Takao, T. Nishii, T. Sakai, and N. Sugano Application of a CT-3D fluoroscopy matching navigation system to the pelvic and femoral regions Comput Aided Surg 17 2012 69 76
    • (2012) Comput Aided Surg , vol.17 , pp. 69-76
    • Takao, M.1    Nishii, T.2    Sakai, T.3    Sugano, N.4
  • 23
    • 84889097444 scopus 로고    scopus 로고
    • CT-3D-fluoroscopy matching navigation can reduce the malposition rate of iliosacral screw insertion for less experienced surgeons
    • M. Takao, T. Nishii, T. Sakai, and N. Sugano CT-3D-fluoroscopy matching navigation can reduce the malposition rate of iliosacral screw insertion for less experienced surgeons J Orthop Trauma 27 2013 716 721
    • (2013) J Orthop Trauma , vol.27 , pp. 716-721
    • Takao, M.1    Nishii, T.2    Sakai, T.3    Sugano, N.4
  • 24
    • 39149129995 scopus 로고    scopus 로고
    • Fracture and dislocation classification compendium - 2007: Orthopaedic Trauma Association classification, database and outcomes committee
    • J.L. Marsh, T.F. Slongo, J. Agel, J.S. Broderick, W. Creevey, and T.A. DeCoster et al. Fracture and dislocation classification compendium - 2007: Orthopaedic Trauma Association classification, database and outcomes committee J Orthop Trauma 21 2007 S1 S133
    • (2007) J Orthop Trauma , vol.21
    • Marsh, J.L.1    Slongo, T.F.2    Agel, J.3    Broderick, J.S.4    Creevey, W.5    Decoster, T.A.6
  • 25
    • 0029689344 scopus 로고    scopus 로고
    • Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: A cadaveric and clinical study
    • M.L. Routt Jr., P.T. Simonian, S.G. Agnew, and F.A. Mann Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: a cadaveric and clinical study J Orthop Trauma 10 1996 171 177
    • (1996) J Orthop Trauma , vol.10 , pp. 171-177
    • Routt, Jr.M.L.1    Simonian, P.T.2    Agnew, S.G.3    Mann, F.A.4
  • 26
    • 77958119660 scopus 로고    scopus 로고
    • Quantification of the upper and second sacral segment safe zones in normal and dysmorphic sacra
    • M.J. Gardner, S. Morshed, S.E. Nork, W.M. Ricci, and M.L. Chip Routt Jr. Quantification of the upper and second sacral segment safe zones in normal and dysmorphic sacra J Orthop Trauma 24 2010 622 629
    • (2010) J Orthop Trauma , vol.24 , pp. 622-629
    • Gardner, M.J.1    Morshed, S.2    Nork, S.E.3    Ricci, W.M.4    Chip Routt, Jr.M.L.5
  • 27
    • 85119089351 scopus 로고    scopus 로고
    • Proximity of iliosacral screws to neurovascular structures after internal fixation
    • D. Templeman, A. Schmidt, J. Freese, and I. Weisman Proximity of iliosacral screws to neurovascular structures after internal fixation Clin Orthop Relat Res 19 1996 4 8
    • (1996) Clin Orthop Relat Res , vol.19 , pp. 4-8
    • Templeman, D.1    Schmidt, A.2    Freese, J.3    Weisman, I.4
  • 28
    • 84878798090 scopus 로고    scopus 로고
    • CT-based 3-D visualisation of secure bone corridors and optimal trajectories for sacroiliac screws
    • T. Mendel, F. Radetzki, D. Wohlrab, K. Stock, G.O. Hofmann, and H. Noser CT-based 3-D visualisation of secure bone corridors and optimal trajectories for sacroiliac screws Injury 44 2013 957 963
    • (2013) Injury , vol.44 , pp. 957-963
    • Mendel, T.1    Radetzki, F.2    Wohlrab, D.3    Stock, K.4    Hofmann, G.O.5    Noser, H.6
  • 29
    • 0037323047 scopus 로고    scopus 로고
    • The effect of sacral fracture malreduction on the safe placement of iliosacral screws
    • M.C. Reilly, C.M. Bono, B. Litkouhi, M. Sirkin, and F.F. Behrens The effect of sacral fracture malreduction on the safe placement of iliosacral screws J Orthop Trauma 17 2003 88 94
    • (2003) J Orthop Trauma , vol.17 , pp. 88-94
    • Reilly, M.C.1    Bono, C.M.2    Litkouhi, B.3    Sirkin, M.4    Behrens, F.F.5
  • 30
    • 0035191045 scopus 로고    scopus 로고
    • Accuracy of computer-guided screw fixation of the sacroiliac joint
    • E. Gautier, R. Bachler, P.F. Heini, and L.P. Nolte Accuracy of computer-guided screw fixation of the sacroiliac joint Clin Orthop Relat Res 393 2001 310 317
    • (2001) Clin Orthop Relat Res , vol.393 , pp. 310-317
    • Gautier, E.1    Bachler, R.2    Heini, P.F.3    Nolte, L.P.4
  • 31
    • 84872790260 scopus 로고    scopus 로고
    • Intraoperative computed tomography with integrated navigation in percutaneous iliosacral screwing
    • K.T. Peng, Y.Y. Li, W.H. Hsu, M.H. Wu, J.T. Yang, and C.H. Hsu et al. Intraoperative computed tomography with integrated navigation in percutaneous iliosacral screwing Injury 44 2013 203 208
    • (2013) Injury , vol.44 , pp. 203-208
    • Peng, K.T.1    Li, Y.Y.2    Hsu, W.H.3    Wu, M.H.4    Yang, J.T.5    Hsu, C.H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.