1
-
-
0029964796
-
Temporally resolved 3D phase-contrast imaging
-
8916033 PubMed PMID:
-
Wigström, L, Sjöqvist, L, Wranne, B, Temporally resolved 3D phase-contrast imaging. Magn. Reson. Med 36 (1996), 800–803 PubMed PMID: 8916033 10.1002/mrm.1910360521.
-
(1996)
Magn. Reson. Med
, vol.36
, pp. 800-803
-
-
Wigström, L.1
Sjöqvist, L.2
Wranne, B.3
-
2
-
-
26044441378
-
Applications of phase-contrast flow and velocity imaging in cardiovascular MRI
-
16003509 PubMed PMID:
-
Gatehouse, PD, Keegan, J, Crowe, LA, Masood, S, Mohiaddin, RH, Kreitner, K-F, Firmin, DN, Applications of phase-contrast flow and velocity imaging in cardiovascular MRI. Eur. Radiol 15 (2005), 2172–2184 PubMed PMID: 16003509 10.1007/s00330-005-2829-3.
-
(2005)
Eur. Radiol
, vol.15
, pp. 2172-2184
-
-
Gatehouse, P.D.1
Keegan, J.2
Crowe, L.A.3
Masood, S.4
Mohiaddin, R.H.5
Kreitner, K.-F.6
Firmin, D.N.7
-
3
-
-
34548598651
-
Flow measurement by magnetic resonance: a unique asset worth optimising
-
17613655 PubMed PMID:
-
Kilner, PJ, Gatehouse, PD, Firmin, DN, Flow measurement by magnetic resonance: a unique asset worth optimising. J. Cardiovasc. Magn. Reson 9 (2007), 723–728 PubMed PMID: 17613655 10.1080/10976640701465090.
-
(2007)
J. Cardiovasc. Magn. Reson
, vol.9
, pp. 723-728
-
-
Kilner, P.J.1
Gatehouse, P.D.2
Firmin, D.N.3
-
4
-
-
79953304124
-
Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance
-
21235751 PubMed PMID:, PMCID
-
Markl, M, Kilner, PJ, Ebbers, T, Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance. J. Cardiovasc. Magn. Reson, 13, 2011, 7 PubMed PMID: 21235751, PMCID 3025879 10.1186/1532-429X-13-7.
-
(2011)
J. Cardiovasc. Magn. Reson
, vol.13
, pp. 7
-
-
Markl, M.1
Kilner, P.J.2
Ebbers, T.3
-
5
-
-
84867819825
-
4D flow MRI
-
23090914 PubMed PMID:
-
Markl, M, Frydrychowicz, A, Kozerke, S, Hope, M, Wieben, O, 4D flow MRI. J. Magn. Reson. Imaging 36 (2012), 1015–1036 PubMed PMID: 23090914 10.1002/jmri.23632.
-
(2012)
J. Magn. Reson. Imaging
, vol.36
, pp. 1015-1036
-
-
Markl, M.1
Frydrychowicz, A.2
Kozerke, S.3
Hope, M.4
Wieben, O.5
-
6
-
-
85082180421
-
Characterization and quantification of dynamic left atrioventricular valve regurgitation after atrioventricular septal defect correction with 4D Flow MRI and retrospective valve tracking
-
Calkoen, E, Westenberg, JJ, Kroft, LJ, van den Boogaard, PJ, Jongbloed, MR, van der Geest, RJ, de Roos, A, Roest, A, Characterization and quantification of dynamic left atrioventricular valve regurgitation after atrioventricular septal defect correction with 4D Flow MRI and retrospective valve tracking. J. Cardiovasc. Magn. Reson, 16(Suppl 1), 2014, 138 10.1186/1532-429X-16-S1-P138.
-
(2014)
J. Cardiovasc. Magn. Reson
, vol.16
, pp. 138
-
-
Calkoen, E.1
Westenberg, J.J.2
Kroft, L.J.3
van den Boogaard, P.J.4
Jongbloed, M.R.5
van der Geest, R.J.6
de Roos, A.7
Roest, A.8
-
7
-
-
21244487801
-
Three-dimensional, isotropic MRI: a unified approach to quantification and visualization in congenital heart disease
-
16015442 PubMed PMID:
-
Sørensen, TS, Beerbaum, P, Körperich, H, Pedersen, EM, Three-dimensional, isotropic MRI: a unified approach to quantification and visualization in congenital heart disease. Int. J. Cardiovasc. Imaging 21 (2005), 283–292 PubMed PMID: 16015442 10.1007/s10554-004-4018-x.
-
(2005)
Int. J. Cardiovasc. Imaging
, vol.21
, pp. 283-292
-
-
Sørensen, T.S.1
Beerbaum, P.2
Körperich, H.3
Pedersen, E.M.4
-
8
-
-
0032915991
-
Particle trace visualization of intracardiac flow using time-resolved 3D phase contrast MRI
-
10332856 PubMed PMID: 10.1002/(SICI)1522-2594(199904)41:4<793::AID-MRM19>3.0.CO;2-2
-
Wigström, L, Ebbers, T, Fyrenius, A, Karlsson, M, Engvall, J, Wranne, B, Bolger, AF, Particle trace visualization of intracardiac flow using time-resolved 3D phase contrast MRI. Magn. Reson. Med 41 (1999), 793–799 PubMed PMID: 10332856 10.1002/(SICI)1522-2594(199904)41:4<793::AID-MRM19>3.0.CO;2-2.
-
(1999)
Magn. Reson. Med
, vol.41
, pp. 793-799
-
-
Wigström, L.1
Ebbers, T.2
Fyrenius, A.3
Karlsson, M.4
Engvall, J.5
Wranne, B.6
Bolger, A.F.7
-
9
-
-
0031830533
-
Visualizing blood flow patterns using streamlines, arrows, and particle paths
-
9702703 PubMed PMID:
-
Buonocore, MH, Visualizing blood flow patterns using streamlines, arrows, and particle paths. Magn. Reson. Med 40 (1998), 210–226 PubMed PMID: 9702703 10.1002/mrm.1910400207.
-
(1998)
Magn. Reson. Med
, vol.40
, pp. 210-226
-
-
Buonocore, M.H.1
-
10
-
-
0025364499
-
Concomitant magnetic field gradients and their effects on imaging at low magnetic field strengths
-
2325514 PubMed PMID:
-
Norris, DG, Hutchison, JM, Concomitant magnetic field gradients and their effects on imaging at low magnetic field strengths. Magn. Reson. Imaging 8 (1990), 33–37 PubMed PMID: 2325514 10.1016/0730-725X(90)90209-K.
-
(1990)
Magn. Reson. Imaging
, vol.8
, pp. 33-37
-
-
Norris, D.G.1
Hutchison, J.M.2
-
11
-
-
0031951298
-
Concomitant gradient terms in phase contrast MR: analysis and correction
-
9469714 PubMed PMID:
-
Bernstein, MA, Zhou, XJ, Polzin, JA, King, KF, Ganin, A, Pelc, NJ, Glover, GH, Concomitant gradient terms in phase contrast MR: analysis and correction. Magn. Reson. Med 39 (1998), 300–308 PubMed PMID: 9469714 10.1002/mrm.1910390218.
-
(1998)
Magn. Reson. Med
, vol.39
, pp. 300-308
-
-
Bernstein, M.A.1
Zhou, X.J.2
Polzin, J.A.3
King, K.F.4
Ganin, A.5
Pelc, N.J.6
Glover, G.H.7
-
12
-
-
0141617513
-
Generalized reconstruction of phase contrast MRI: analysis and correction of the effect of gradient field distortions
-
14523966 PubMed PMID:
-
Markl, M, Bammer, R, Alley, MT, Elkins, CJ, Draney, MT, Barnett, A, Moseley, ME, Glover, GH, Pelc, NJ, Generalized reconstruction of phase contrast MRI: analysis and correction of the effect of gradient field distortions. Magn. Reson. Med 50 (2003), 791–801 PubMed PMID: 14523966 10.1002/mrm.10582.
-
(2003)
Magn. Reson. Med
, vol.50
, pp. 791-801
-
-
Markl, M.1
Bammer, R.2
Alley, M.T.3
Elkins, C.J.4
Draney, M.T.5
Barnett, A.6
Moseley, M.E.7
Glover, G.H.8
Pelc, N.J.9
-
13
-
-
12144274440
-
Analysis and correction of gradient nonlinearity and B0 inhomogeneity related scaling errors in two-dimensional phase contrast flow measurements
-
15690511 PubMed PMID:
-
Peeters, JM, Bos, C, Bakker, CJG, Analysis and correction of gradient nonlinearity and B0 inhomogeneity related scaling errors in two-dimensional phase contrast flow measurements. Magn. Reson. Med 53 (2005), 126–133 PubMed PMID: 15690511 10.1002/mrm.20309.
-
(2005)
Magn. Reson. Med
, vol.53
, pp. 126-133
-
-
Peeters, J.M.1
Bos, C.2
Bakker, C.J.G.3
-
14
-
-
44949288378
-
Optimization of eddy-current compensation
-
Van Vaals, J, Bergman, A, Optimization of eddy-current compensation. J. Magn. Reson 70 (1990), 52–70.
-
(1990)
J. Magn. Reson
, vol.70
, pp. 52-70
-
-
Van Vaals, J.1
Bergman, A.2
-
15
-
-
84859724260
-
Analysis and correction of background velocity offsets in phase-contrast flow measurements using magnetic field monitoring
-
21826731 PubMed PMID:
-
Giese, D, Haeberlin, M, Barmet, C, Pruessmann, KP, Schaeffter, T, Kozerke, S, Analysis and correction of background velocity offsets in phase-contrast flow measurements using magnetic field monitoring. Magn. Reson. Med 67 (2012), 1294–1302 PubMed PMID: 21826731 10.1002/mrm.23111.
-
(2012)
Magn. Reson. Med
, vol.67
, pp. 1294-1302
-
-
Giese, D.1
Haeberlin, M.2
Barmet, C.3
Pruessmann, K.P.4
Schaeffter, T.5
Kozerke, S.6
-
16
-
-
77949314852
-
Flow measurement by cardiovascular magnetic resonance: a multi-centre multi-vendor study of background phase offset errors that can compromise the accuracy of derived regurgitant or shunt flow measurements
-
20074359 PubMed PMID:, PMCID
-
Gatehouse, PD, Rolf, MP, Graves, MJ, Hofman, MB, Totman, J, Werner, B, Quest, RA, Liu, Y, von Spiczak, J, Dieringer, M, Firmin, DN, van Rossum, A, Lombardi, M, Schwitter, J, Schulz-Menger, J, Kilner, PJ, Flow measurement by cardiovascular magnetic resonance: a multi-centre multi-vendor study of background phase offset errors that can compromise the accuracy of derived regurgitant or shunt flow measurements. J. Cardiovasc. Magn. Reson, 12, 2010, 5 PubMed PMID: 20074359, PMCID 2818657 10.1186/1532-429X-12-5.
-
(2010)
J. Cardiovasc. Magn. Reson
, vol.12
, pp. 5
-
-
Gatehouse, P.D.1
Rolf, M.P.2
Graves, M.J.3
Hofman, M.B.4
Totman, J.5
Werner, B.6
Quest, R.A.7
Liu, Y.8
von Spiczak, J.9
Dieringer, M.10
Firmin, D.N.11
van Rossum, A.12
Lombardi, M.13
Schwitter, J.14
Schulz-Menger, J.15
Kilner, P.J.16
-
17
-
-
84902552073
-
Influence of eddy current, Maxwell and gradient field corrections on 3D flow visualization of 3D CINE PC-MRI data
-
24006013 PubMed PMID:, PMCID
-
Lorenz, R, Bock, J, Snyder, J, Korvink, JG, Jung, BA, Markl, M, Influence of eddy current, Maxwell and gradient field corrections on 3D flow visualization of 3D CINE PC-MRI data. Magn. Reson. Med 72 (2014), 33–40 PubMed PMID: 24006013, PMCID 3872262 10.1002/mrm.24885.
-
(2014)
Magn. Reson. Med
, vol.72
, pp. 33-40
-
-
Lorenz, R.1
Bock, J.2
Snyder, J.3
Korvink, J.G.4
Jung, B.A.5
Markl, M.6
-
18
-
-
20644444942
-
Flow-velocity imaging from linear regression of phase images with techniques for reducing eddy-current effects
-
Caprihan, A, Altobelli, S, Benitez-Read, E, Flow-velocity imaging from linear regression of phase images with techniques for reducing eddy-current effects. J. Magn. Reson 90 (1990), 71–89.
-
(1990)
J. Magn. Reson
, vol.90
, pp. 71-89
-
-
Caprihan, A.1
Altobelli, S.2
Benitez-Read, E.3
-
19
-
-
0027602212
-
Semiautomated method for noise reduction and background phase error correction in MR phase velocity data
-
8324312 PubMed PMID:
-
Walker, PG, Cranney, GB, Scheidegger, MB, Waseleski, G, Pohost, GM, Yoganathan, AP, Semiautomated method for noise reduction and background phase error correction in MR phase velocity data. J. Magn. Reson. Imaging 3 (1993), 521–530 PubMed PMID: 8324312 10.1002/jmri.1880030315.
-
(1993)
J. Magn. Reson. Imaging
, vol.3
, pp. 521-530
-
-
Walker, P.G.1
Cranney, G.B.2
Scheidegger, M.B.3
Waseleski, G.4
Pohost, G.M.5
Yoganathan, A.P.6
-
20
-
-
21244500569
-
Correction of phase offset errors in main pulmonary artery flow quantification
-
15971181 PubMed PMID:
-
Lankhaar, J-W, Hofman, MBM, Marcus, JT, Zwanenburg, JJM, Faes, TJC, Vonk-Noordegraaf, A, Correction of phase offset errors in main pulmonary artery flow quantification. J. Magn. Reson. Imaging 22 (2005), 73–79 PubMed PMID: 15971181 10.1002/jmri.20361.
-
(2005)
J. Magn. Reson. Imaging
, vol.22
, pp. 73-79
-
-
Lankhaar, J.-W.1
Hofman, M.B.M.2
Marcus, J.T.3
Zwanenburg, J.J.M.4
Faes, T.J.C.5
Vonk-Noordegraaf, A.6
-
21
-
-
84904476709
-
-
thAnnual Meeting of ISMRM, Melbourne, Australia
-
thAnnual Meeting of ISMRM, Melbourne, Australia.
-
(2012)
Pre-emphasis Compensation of Oscillatory Phase Offsets in Phase-Contrast Flow Measurements
, pp. 1172
-
-
Busch, J.1
Vannesjoe, S.J.2
Giese, D.3
Barmet, C.4
Pruessmann, K.5
Kozerke, S.6
-
22
-
-
84867592105
-
A multi-center inter-manufacturer study of the temporal stability of phase-contrast velocity mapping background offset errors
-
23083397 PubMed PMID:, PMCID
-
Gatehouse, PD, Rolf, MP, Bloch, KM, Graves, MJ, Kilner, PJ, Firmin, DN, Hofman, MBM, A multi-center inter-manufacturer study of the temporal stability of phase-contrast velocity mapping background offset errors. J. Cardiovasc. Magn. Reson, 14, 2012, 72 PubMed PMID: 23083397, PMCID 3514147 10.1186/1532-429X-14-72.
-
(2012)
J. Cardiovasc. Magn. Reson
, vol.14
, pp. 72
-
-
Gatehouse, P.D.1
Rolf, M.P.2
Bloch, K.M.3
Graves, M.J.4
Kilner, P.J.5
Firmin, D.N.6
Hofman, M.B.M.7
-
23
-
-
0028854765
-
Three-point phase-contrast velocity measurements with increased velocity-to-noise ratio
-
7891526 PubMed PMID:
-
Lee, AT, Pike, GB, Pelc, NJ, Three-point phase-contrast velocity measurements with increased velocity-to-noise ratio. Magn. Reson. Med 33 (1995), 122–126 PubMed PMID: 7891526 10.1002/mrm.1910330119.
-
(1995)
Magn. Reson. Med
, vol.33
, pp. 122-126
-
-
Lee, A.T.1
Pike, G.B.2
Pelc, N.J.3
-
24
-
-
33749173288
-
Quantification of intravoxel velocity standard deviation and turbulence intensity by generalizing phase-contrast MRI
-
16958074 PubMed PMID:
-
Dyverfeldt, P, Sigfridsson, A, Kvitting, J-PE, Ebbers, T, Quantification of intravoxel velocity standard deviation and turbulence intensity by generalizing phase-contrast MRI. Magn. Reson. Med 56 (2006), 850–858 PubMed PMID: 16958074 10.1002/mrm.21022.
-
(2006)
Magn. Reson. Med
, vol.56
, pp. 850-858
-
-
Dyverfeldt, P.1
Sigfridsson, A.2
Kvitting, J.-P.E.3
Ebbers, T.4
-
25
-
-
84876471400
-
Bayesian multipoint velocity encoding for concurrent flow and turbulence mapping
-
22700280 PubMed PMID:
-
Binter, C, Knobloch, V, Manka, R, Sigfridsson, A, Kozerke, S, Bayesian multipoint velocity encoding for concurrent flow and turbulence mapping. Magn. Reson. Med 69 (2013), 1337–1345 PubMed PMID: 22700280 10.1002/mrm.24370.
-
(2013)
Magn. Reson. Med
, vol.69
, pp. 1337-1345
-
-
Binter, C.1
Knobloch, V.2
Manka, R.3
Sigfridsson, A.4
Kozerke, S.5
-
26
-
-
46849097841
-
Spatiotemporal magnetic field monitoring for MR
-
18581361 PubMed PMID:
-
Barmet, C, De Zanche, N, Pruessmann, KP, Spatiotemporal magnetic field monitoring for MR. Magn. Reson. Med 60 (2008), 187–197 PubMed PMID: 18581361 10.1002/mrm.21603.
-
(2008)
Magn. Reson. Med
, vol.60
, pp. 187-197
-
-
Barmet, C.1
De Zanche, N.2
Pruessmann, K.P.3
-
27
-
-
84862244703
-
Simple method for MR gradient system characterization and k-space trajectory estimation
-
22189904 PubMed PMID:, PMCID
-
Addy, NO, Wu, HH, Nishimura, DG, Simple method for MR gradient system characterization and k-space trajectory estimation. Magn. Reson. Med 68 (2012), 120–129 PubMed PMID: 22189904, PMCID 4048453 10.1002/mrm.23217.
-
(2012)
Magn. Reson. Med
, vol.68
, pp. 120-129
-
-
Addy, N.O.1
Wu, H.H.2
Nishimura, D.G.3
-
28
-
-
84872956985
-
Gradient system characterization by impulse response measurements with a dynamic field camera
-
22499483 PubMed PMID:
-
Vannesjo, SJ, Haeberlin, M, Kasper, L, Pavan, M, Wilm, BJ, Barmet, C, Pruessmann, KP, Gradient system characterization by impulse response measurements with a dynamic field camera. Magn. Reson. Med 69 (2013), 583–593 PubMed PMID: 22499483 10.1002/mrm.24263.
-
(2013)
Magn. Reson. Med
, vol.69
, pp. 583-593
-
-
Vannesjo, S.J.1
Haeberlin, M.2
Kasper, L.3
Pavan, M.4
Wilm, B.J.5
Barmet, C.6
Pruessmann, K.P.7
-
29
-
-
84904498156
-
Field camera measurements of gradient and shim impulse responses using frequency sweeps
-
24105800 PubMed PMID:
-
Vannesjo, SJ, Dietrich, BE, Pavan, M, Brunner, DO, Wilm, BJ, Barmet, C, Pruessmann, KP, Field camera measurements of gradient and shim impulse responses using frequency sweeps. Magn. Reson. Med 72 (2014), 570–583 PubMed PMID: 24105800 10.1002/mrm.24934.
-
(2014)
Magn. Reson. Med
, vol.72
, pp. 570-583
-
-
Vannesjo, S.J.1
Dietrich, B.E.2
Pavan, M.3
Brunner, D.O.4
Wilm, B.J.5
Barmet, C.6
Pruessmann, K.P.7
-
31
-
-
73149111748
-
Characterizing and correcting gradient errors in non-cartesian imaging: Are gradient errors linear time-invariant (LTI)?
-
19877274 PubMed PMID:, PMCID
-
Brodsky, EK, Samsonov, AA, Block, WF, Characterizing and correcting gradient errors in non-cartesian imaging: Are gradient errors linear time-invariant (LTI)?. Magn. Reson. Med 62 (2009), 1466–1476 PubMed PMID: 19877274, PMCID 2857383 10.1002/mrm.22100.
-
(2009)
Magn. Reson. Med
, vol.62
, pp. 1466-1476
-
-
Brodsky, E.K.1
Samsonov, A.A.2
Block, W.F.3
-
32
-
-
79958782233
-
Sequence optimization to reduce velocity offsets in cardiovascular magnetic resonance volume flow quantification–a multi-vendor study
-
21388521 PubMed PMID:, PMCID
-
Rolf, MP, Hofman, MBM, Gatehouse, PD, Markenroth-Bloch, K, Heymans, MW, Ebbers, T, Graves, MJ, Totman, JJ, Werner, B, van Rossum, AC, Kilner, PJ, Heethaar, RM, Sequence optimization to reduce velocity offsets in cardiovascular magnetic resonance volume flow quantification–a multi-vendor study. J. Cardiovasc. Magn. Reson, 13, 2011, 18 PubMed PMID: 21388521, PMCID 3065419 10.1186/1532-429X-13-18.
-
(2011)
J. Cardiovasc. Magn. Reson
, vol.13
, pp. 18
-
-
Rolf, M.P.1
Hofman, M.B.M.2
Gatehouse, P.D.3
Markenroth-Bloch, K.4
Heymans, M.W.5
Ebbers, T.6
Graves, M.J.7
Totman, J.J.8
Werner, B.9
van Rossum, A.C.10
Kilner, P.J.11
Heethaar, R.M.12
-
33
-
-
0029764858
-
Simple measurement of scanner stability for functional NMR imaging of activation in the brain
-
8892220 PubMed PMID:
-
Weisskoff, R, Simple measurement of scanner stability for functional NMR imaging of activation in the brain. Magn. Reson. Med 36 (1996), 643–645 PubMed PMID: 8892220 10.1002/mrm.1910360422.
-
(1996)
Magn. Reson. Med
, vol.36
, pp. 643-645
-
-
Weisskoff, R.1
-
34
-
-
33744728683
-
Report on a multicenter fMRI quality assurance protocol
-
16649196 PubMed PMID:
-
Friedman, L, Glover, GH, Report on a multicenter fMRI quality assurance protocol. J. Magn. Reson. Imaging 23 (2006), 827–839 PubMed PMID: 16649196 10.1002/jmri.20583.
-
(2006)
J. Magn. Reson. Imaging
, vol.23
, pp. 827-839
-
-
Friedman, L.1
Glover, G.H.2
-
35
-
-
27644557313
-
Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging
-
16215962 PubMed PMID:, PMCID
-
Foerster, BU, Tomasi, D, Caparelli, EC, Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging. Magn. Reson. Med 54 (2005), 1261–1267 PubMed PMID: 16215962, PMCID 2408718 10.1002/mrm.20695.
-
(2005)
Magn. Reson. Med
, vol.54
, pp. 1261-1267
-
-
Foerster, B.U.1
Tomasi, D.2
Caparelli, E.C.3
-
36
-
-
84937726903
-
-
Monitoring, analysis, and correction of magnetic field fluctuations in echo planar imaging time series.Magn Reson Med. published ahead of print, 10.1002/mrm.25407.
-
Kasper L, Bollmann S, Vannesjo SJ, Gross S, Haeberlin M, Dietrich BE, Pruessmann KP. Monitoring, analysis, and correction of magnetic field fluctuations in echo planar imaging time series.Magn Reson Med. published ahead of print, 10.1002/mrm.25407.,.
-
-
-
Kasper, L.1
Bollmann, S.2
Vannesjo, S.J.3
Gross, S.4
Haeberlin, M.5
Dietrich, B.E.6
Pruessmann, K.P.7
-
37
-
-
85181020051
-
-
In: Proceedings of the 18 th Annual Meeting of ISMRM, Stockholm, Sweden
-
Barmet, C, Wilm, BJ, Pavan, M, Katsikatsos, G, Keupp, J, Mens, G, Pruessmann, KP, Concurrent higher-order field monitoring for routine head MRI: an integrated heteronuclear setup, 2010, 216 In: Proceedings of the 18 th Annual Meeting of ISMRM, Stockholm, Sweden.
-
(2010)
Concurrent higher-order field monitoring for routine head MRI: an integrated heteronuclear setup
, pp. 216
-
-
Barmet, C.1
Wilm, B.J.2
Pavan, M.3
Katsikatsos, G.4
Keupp, J.5
Mens, G.6
Pruessmann, K.P.7
-
38
-
-
79958262990
-
Higher order reconstruction for MRI in the presence of spatiotemporal field perturbations
-
21520269 PubMed PMID:
-
Wilm, BJ, Barmet, C, Pavan, M, Pruessmann, KP, Higher order reconstruction for MRI in the presence of spatiotemporal field perturbations. Magn. Reson. Med 65 (2011), 1690–1701 PubMed PMID: 21520269 10.1002/mrm.22767.
-
(2011)
Magn. Reson. Med
, vol.65
, pp. 1690-1701
-
-
Wilm, B.J.1
Barmet, C.2
Pavan, M.3
Pruessmann, K.P.4
-
39
-
-
84903894048
-
Matched-Filter Acquisition for BOLD fMRI
-
24844745 PubMed PMID:
-
Kasper, L, Haeberlin, M, Dietrich, BE, Gross, S, Barmet, C, Wilm, BJ, Vannesjo, SJ, Brunner, DO, Ruff, CC, Stephan, KE, Pruessmann, KP, Matched-Filter Acquisition for BOLD fMRI. Neuroimage 100 (2014), 145–160 PubMed PMID: 24844745 10.1016/j.neuroimage.2014.05.024.
-
(2014)
Neuroimage
, vol.100
, pp. 145-160
-
-
Kasper, L.1
Haeberlin, M.2
Dietrich, B.E.3
Gross, S.4
Barmet, C.5
Wilm, B.J.6
Vannesjo, S.J.7
Brunner, D.O.8
Ruff, C.C.9
Stephan, K.E.10
Pruessmann, K.P.11
|