메뉴 건너뛰기




Volumn 69, Issue 2, 2013, Pages 583-593

Gradient system characterization by impulse response measurements with a dynamic field camera

Author keywords

dynamic shimming; GIRF; gradient calibration; gradient impulse response; linear time invariant systems; magnetic field monitoring; mechanical oscillations

Indexed keywords

CAMERAS; EDDY CURRENTS; IMAGE RECONSTRUCTION; IMPULSE RESPONSE; INVARIANCE; LINEAR SYSTEMS; NUCLEAR MAGNETIC RESONANCE; QUALITY ASSURANCE; TIME VARYING CONTROL SYSTEMS;

EID: 84872956985     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24263     Document Type: Article
Times cited : (171)

References (36)
  • 1
    • 0025832121 scopus 로고
    • Temporal and spatial analysis of fields generated by eddy currents in superconducting magnets: Optimization of corrections and quantitative characterization of magnet/gradient systems
    • Boesch C, Gruetter R, Martin E,. Temporal and spatial analysis of fields generated by eddy currents in superconducting magnets: optimization of corrections and quantitative characterization of magnet/gradient systems. Magn Reson Med 1991; 20: 268-284.
    • (1991) Magn Reson Med , vol.20 , pp. 268-284
    • Boesch, C.1    Gruetter, R.2    Martin, E.3
  • 2
    • 0027961623 scopus 로고
    • Quantitative characterization of the eddy current fields in a 40-cm bore superconducting magnet
    • Liu Q, Hughes DG, Allen PS,. Quantitative characterization of the eddy current fields in a 40-cm bore superconducting magnet. Magn Reson Med 1994; 31: 73-76.
    • (1994) Magn Reson Med , vol.31 , pp. 73-76
    • Liu, Q.1    Hughes, D.G.2    Allen, P.S.3
  • 3
    • 0033772807 scopus 로고    scopus 로고
    • Gradient-induced acoustic and magnetic field fluctuations in a 4 T whole-body MR imager
    • Wu YH, Chronik BA, Bowen C, Mechefske CK, Rutt BK,. Gradient-induced acoustic and magnetic field fluctuations in a 4 T whole-body MR imager. Magn Reson Med 2000; 44: 532-536.
    • (2000) Magn Reson Med , vol.44 , pp. 532-536
    • Wu, Y.H.1    Chronik, B.A.2    Bowen, C.3    Mechefske, C.K.4    Rutt, B.K.5
  • 4
    • 0035542916 scopus 로고    scopus 로고
    • 1H Spectroscopy without solvent suppression: Characterization of signal modulations at short echo times
    • Clayton DB, Elliott MA, Leigh JS, Lenkinski RE,. 1H Spectroscopy without solvent suppression: characterization of signal modulations at short echo times. J Magn Reson 2001; 153: 203-209.
    • (2001) J Magn Reson , vol.153 , pp. 203-209
    • Clayton, D.B.1    Elliott, M.A.2    Leigh, J.S.3    Lenkinski, R.E.4
  • 5
    • 27644557313 scopus 로고    scopus 로고
    • Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging
    • DOI 10.1002/mrm.20695
    • Foerster BU, Tomasi D, Caparelli EC,. Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging. Magn Reson Med 2005; 54: 1261-1267. (Pubitemid 41567206)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.5 , pp. 1261-1267
    • Foerster, B.U.1    Tomasi, D.2    Caparelli, E.C.3
  • 6
    • 0036011151 scopus 로고    scopus 로고
    • Respiration-induced B0 fluctuations and their spatial distribution in the human brain at 7 Tesla
    • Van de Moortele P, Pfeuffer J, Glover GH, Ugurbil K, Hu X,. Respiration-induced B0 fluctuations and their spatial distribution in the human brain at 7 Tesla. Magn Reson Med 2002; 47: 888-895.
    • (2002) Magn Reson Med , vol.47 , pp. 888-895
    • Van De Moortele, P.1    Pfeuffer, J.2    Glover, G.H.3    Ugurbil, K.4    Hu, X.5
  • 7
    • 77952554376 scopus 로고    scopus 로고
    • Origin and reduction of motion and f0 artifacts in high resolution T2-weighted magnetic resonance imaging: Application in Alzheimer's disease patients
    • Versluis MJ, Peeters JM, van Rooden S, van der Grond J, van Buchem MA, Webb AG, van Osch MJP,. Origin and reduction of motion and f0 artifacts in high resolution T2-weighted magnetic resonance imaging: application in Alzheimer's disease patients. NeuroImage 2010; 51: 1082-1088.
    • (2010) NeuroImage , vol.51 , pp. 1082-1088
    • Versluis, M.J.1    Peeters, J.M.2    Van Rooden, S.3    Van Der Grond, J.4    Van Buchem, M.A.5    Webb, A.G.6    Van Osch, M.J.P.7
  • 8
    • 0001426032 scopus 로고
    • Analytical method for the compensation of eddy-current effects induced by pulsed magnetic field gradients in NMR systems
    • Jehenson P, Westphal M, Schuff N,. Analytical method for the compensation of eddy-current effects induced by pulsed magnetic field gradients in NMR systems. J Magn Reson 1990; 90: 264-278.
    • (1990) J Magn Reson , vol.90 , pp. 264-278
    • Jehenson, P.1    Westphal, M.2    Schuff, N.3
  • 9
    • 44949288378 scopus 로고
    • Optimization of eddy-current compensation
    • van Vaals JJ, Bergman AH,. Optimization of eddy-current compensation. J Magn Reson 1990; 90: 52-70.
    • (1990) J Magn Reson , vol.90 , pp. 52-70
    • Van Vaals, J.J.1    Bergman, A.H.2
  • 10
    • 0028354303 scopus 로고
    • A novel eddy current compensation scheme for pulsed gradient systems
    • Wysong RE, Madio DP, Lowe IJ,. A novel eddy current compensation scheme for pulsed gradient systems. Magn Reson Med 1994; 31: 572-575. (Pubitemid 24129955)
    • (1994) Magnetic Resonance in Medicine , vol.31 , Issue.5 , pp. 572-575
    • Wysong, R.E.1    Madio, D.P.2    Lowe, I.J.3
  • 11
    • 0031978367 scopus 로고    scopus 로고
    • Characterization of and correction for eddy current artifacts in echo planar diffusion imaging
    • DOI 10.1002/mrm.1910390518
    • Jezzard P, Barnett AS, Pierpaoli C,. Characterization of and correction for eddy current artifacts in echo planar diffusion imaging. Magn Reson Med 1998; 39: 801-812. (Pubitemid 28189153)
    • (1998) Magnetic Resonance in Medicine , vol.39 , Issue.5 , pp. 801-812
    • Jezzard, P.1    Barnett, A.S.2    Pierpaoli, C.3
  • 12
    • 0030047723 scopus 로고    scopus 로고
    • An algorithm for eddy currents symmetrization and compensation
    • DOI 10.1002/mrm.1910350218
    • Zur Y, Stokar S,. An algorithm for eddy currents symmetrization and compensation. Magn Reson Med 1996; 35: 252-260. (Pubitemid 26044394)
    • (1996) Magnetic Resonance in Medicine , vol.35 , Issue.2 , pp. 252-260
    • Zur, Y.1    Stokar, S.2
  • 13
    • 0345634824 scopus 로고
    • Temporal spherical-harmonic expansion and compensation of eddy-current fields produced by gradient pulses
    • Eccles CD, Crozier S, Westphal M, Doddrell DM,. Temporal spherical-harmonic expansion and compensation of eddy-current fields produced by gradient pulses. J Magn Reson Ser A 1993; 103: 135-141.
    • (1993) J Magn Reson ser A , vol.103 , pp. 135-141
    • Eccles, C.D.1    Crozier, S.2    Westphal, M.3    Doddrell, D.M.4
  • 14
    • 0034899102 scopus 로고    scopus 로고
    • Comments on "gradient-induced acoustic and magnetic field fluctuations in a 4T whole-body MR imager"
    • DOI 10.1002/mrm.1179
    • Barnett A,. Comments on "Gradient-induced acoustic and magnetic field fluctuations in a 4 T whole-body MR imager." Magn Reson Med 2001; 46: 207. (Pubitemid 32703263)
    • (2001) Magnetic Resonance in Medicine , vol.46 , Issue.2 , pp. 207
    • Barnett, A.1
  • 15
    • 44149089827 scopus 로고    scopus 로고
    • Compensation of gradient-induced magnetic field perturbations
    • Nixon TW, McIntyre S, Rothman DL, de Graaf RA,. Compensation of gradient-induced magnetic field perturbations. J Magn Reson 2008; 192: 209-217.
    • (2008) J Magn Reson , vol.192 , pp. 209-217
    • Nixon, T.W.1    McIntyre, S.2    Rothman, D.L.3    De Graaf, R.A.4
  • 16
    • 0031032023 scopus 로고    scopus 로고
    • Characterization and prediction of gradient acoustic noise in MR imagers
    • DOI 10.1002/mrm.1910370103
    • Hedeen RA, Edelstein WA,. Characterization and prediction of gradient acoustic noise in MR imagers. Magn Reson Med 1997; 37: 7-10. (Pubitemid 27008824)
    • (1997) Magnetic Resonance in Medicine , vol.37 , Issue.1 , pp. 7-10
    • Hedeen, R.A.1    Edelstein, W.A.2
  • 21
    • 0027462082 scopus 로고
    • A simple method of measuring gradient induced eddy currents to set compensation networks
    • Wysong RE, Lowe IJ,. A simple method of measuring gradient induced eddy currents to set compensation networks. Magn Reson Med 1993; 29: 119-121. (Pubitemid 23063079)
    • (1993) Magnetic Resonance in Medicine , vol.29 , Issue.1 , pp. 119-121
    • Wysong, R.E.1    Lowe, I.J.2
  • 22
    • 0032012581 scopus 로고    scopus 로고
    • Localized Eddy Current Compensation Using Quantitative Field Mapping
    • Terpstra M, Andersen PM, Gruetter R,. Localized eddy current compensation using quantitative field mapping. J Magn Reson 1998; 131: 139-143. (Pubitemid 128450545)
    • (1998) Journal of Magnetic Resonance , vol.131 , Issue.1 , pp. 139-143
    • Terpstra, M.1    Andersen, P.M.2    Gruetter, R.3
  • 24
    • 0031895850 scopus 로고    scopus 로고
    • Gradient characterization using a fourier-transform technique
    • DOI 10.1002/mrm.1910390411
    • Alley MT, Glover GH, Pelc NJ,. Gradient characterization using a Fourier-transform technique. Magn Reson Med 1998; 39: 581-587. (Pubitemid 28150992)
    • (1998) Magnetic Resonance in Medicine , vol.39 , Issue.4 , pp. 581-587
    • Alley, M.T.1    Glover, G.H.2    Pelc, N.J.3
  • 32
    • 67650085818 scopus 로고    scopus 로고
    • A transmit/receive system for magnetic field monitoring of in vivo MRI
    • Barmet C, De Zanche N, Wilm BJ, Pruessmann KP,. A transmit/receive system for magnetic field monitoring of in vivo MRI. Magn Reson Med 2009; 62: 269-276.
    • (2009) Magn Reson Med , vol.62 , pp. 269-276
    • Barmet, C.1    De Zanche, N.2    Wilm, B.J.3    Pruessmann, K.P.4
  • 33
    • 79958262990 scopus 로고    scopus 로고
    • Higher order reconstruction for MRI in the presence of spatiotemporal field perturbations
    • Wilm BJ, Barmet C, Pavan M, Pruessmann KP,. Higher order reconstruction for MRI in the presence of spatiotemporal field perturbations. Magn Reson Med 2011; 65: 1690-1701.
    • (2011) Magn Reson Med , vol.65 , pp. 1690-1701
    • Wilm, B.J.1    Barmet, C.2    Pavan, M.3    Pruessmann, K.P.4
  • 35
    • 84859724260 scopus 로고    scopus 로고
    • Analysis and correction of background velocity offsets in phase-contrast flow measurements using magnetic field monitoring
    • Giese D, Haeberlin M, Barmet C, Pruessmann KP, Schaeffter T, Kozerke S,. Analysis and correction of background velocity offsets in phase-contrast flow measurements using magnetic field monitoring. Magn Reson Med, 2012. 67: 1294-1302.
    • (2012) Magn Reson Med , vol.67 , pp. 1294-1302
    • Giese, D.1    Haeberlin, M.2    Barmet, C.3    Pruessmann, K.P.4    Schaeffter, T.5    Kozerke, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.