메뉴 건너뛰기




Volumn 68, Issue 1, 2012, Pages 120-129

Simple method for MR gradient system characterization and k-space trajectory estimation

Author keywords

Fast MRI; Gradient characterization; Gradient delays; k space trajectory; Non Cartesian imaging

Indexed keywords

FOURIER TRANSFORMS; IMAGE RECONSTRUCTION; MAGNETIC RESONANCE IMAGING; SPACE FLIGHT;

EID: 84862244703     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.23217     Document Type: Article
Times cited : (81)

References (30)
  • 4
    • 0023327739 scopus 로고
    • METHOD OF MEASURING FIELD-GRADIENT MODULATION SHAPES. APPLICATION TO HIGH-SPEED NMR SPECTROSCOPIC IMAGING.
    • Onodera T, Matsui S, Sekihara K, Kohno H. A method of measuring field-gradient modulation shapes. Application to high-speed NMR spectroscopic imaging. J Phys E: Sci Instrum 1987;20:416-419. (Pubitemid 17570183)
    • (1987) Journal of Physics E: Scientific Instruments , vol.20 , Issue.4 , pp. 416-419
    • Onodera, T.1    Matsui, S.2    Sekihara, K.3    Kohno, H.4
  • 5
    • 0029121371 scopus 로고
    • Compensation of multi-dimensional selective excitation pulses using measured κ-space trajectories
    • Takahashi A, Peters T. Compensation of multi-dimensional selective excitation pulses using measured κ-space trajectories. Magn Reson Med 1995;34:446-456.
    • (1995) Magn Reson Med , vol.34 , pp. 446-456
    • Takahashi, A.1    Peters, T.2
  • 6
    • 0030754566 scopus 로고    scopus 로고
    • A general method for measurement of the time integral of variant magnetic field gradients: Application to 2D spiral imaging
    • DOI 10.1016/S0730-725X(97)00014-3, PII S0730725X97000143
    • Papadakis NG,Wilkinson AA, Carpenter TA, Hall LD. A general method for measurement of the time integral of variant magnetic field gradients: application to 2Dspiral imaging. Magn Reson Imaging 1997;15:567-578. (Pubitemid 27327265)
    • (1997) Magnetic Resonance Imaging , vol.15 , Issue.5 , pp. 567-578
    • Papadakis, N.G.1    Wilkinson, A.A.2    Carpenter, T.A.3    Hall, L.D.4
  • 11
    • 35448964383 scopus 로고    scopus 로고
    • Simple phase method for measurement of magnetic field gradient waveforms
    • DOI 10.1016/j.mri.2007.02.002, PII S0730725X07001397
    • Latta P, Gruwel MLH, Volotovskyy V, Weber MH, Tomanek B. Simple phase method for measurement of magnetic field gradient waveforms. Magn Reson Imaging 2007;25:1272-1276. (Pubitemid 47625917)
    • (2007) Magnetic Resonance Imaging , vol.25 , Issue.9 , pp. 1272-1276
    • Latta, P.1    Gruwel, M.L.H.2    Volotovskyy, V.3    Weber, M.H.4    Tomanek, B.5
  • 12
    • 0029098619 scopus 로고
    • Spiral imaging on a small-bore system at 4.7T
    • Spielman DM, Pauly JM. Spiral imaging on a small-bore system at 4.7T. Magn Reson Med 1995;34:580-585.
    • (1995) Magn Reson Med , vol.34 , pp. 580-585
    • Spielman, D.M.1    Pauly, J.M.2
  • 14
    • 0037925300 scopus 로고    scopus 로고
    • Centering the projection reconstruction trajectory: Reducing gradient delay errors
    • DOI 10.1002/mrm.10501
    • Peters DC, Derbyshire JA, McVeigh ER. Centering the projection reconstruction trajectory: reducing gradient delay errors. Magn Reson Med 2003;50:1-6. (Pubitemid 36841852)
    • (2003) Magnetic Resonance in Medicine , vol.50 , Issue.1 , pp. 1-6
    • Peters, D.C.1    Derbyshire, J.A.2    McVeigh, E.R.3
  • 15
    • 67749120067 scopus 로고    scopus 로고
    • Characterization and correction of system delays and eddy currents for MR imaging with ultrashort echotime and time-varying gradients
    • Atkinson IC, Lu A, Thulborn KR. Characterization and correction of system delays and eddy currents for MR imaging with ultrashort echotime and time-varying gradients. Magn Reson Med 2009;62:532-537.
    • (2009) Magn Reson Med , vol.62 , pp. 532-537
    • Atkinson, I.C.1    Lu, A.2    Thulborn, K.R.3
  • 16
    • 67049114284 scopus 로고    scopus 로고
    • Estimation of κ-space trajectories in spiral MRI
    • Tan H,Meyer CH. Estimation of κ-space trajectories in spiral MRI.Magn Reson Med 2009;61:1396-1404.
    • (2009) Magn Reson Med , vol.61 , pp. 1396-1404
    • Tan, H.1    Meyer, C.H.2
  • 17
    • 77952715712 scopus 로고    scopus 로고
    • Fast, simple gradient delay estimation for spiral MRI
    • Robison RK, Devaraj A, Pipe JG. Fast, simple gradient delay estimation for spiral MRI. Magn Reson Med 2010;63:1683-1690.
    • (2010) Magn Reson Med , vol.63 , pp. 1683-1690
    • Robison, R.K.1    Devaraj, A.2    Pipe, J.G.3
  • 20
    • 0001426032 scopus 로고
    • Analytical method for the compensation of eddy-current effects induced by pulsed magnetic field gradients in NMR systems
    • Jehenson P,WestphalM, Schuff N. Analytical method for the compensation of eddy-current effects induced by pulsed magnetic field gradients in NMR systems. J Magn Reson 1990;90:264-278.
    • (1990) J Magn Reson , vol.90 , pp. 264-278
    • Jehenson, P.1    Westphal, M.2    Schuff, N.3
  • 21
    • 44949288378 scopus 로고
    • Optimization of eddy-current compensation
    • Van Vaals JJ, Bergman AH. Optimization of eddy-current compensation. J Magn Reson 1990;90:52-70.
    • (1990) J Magn Reson , vol.90 , pp. 52-70
    • Van Vaals, J.J.1    Bergman, A.H.2
  • 22
    • 73149111748 scopus 로고    scopus 로고
    • Characterizing and correcting gradient errors in non-Cartesian imaging: Are gradient errors linear timeinvariant (LTI)?
    • Brodsky EK, Samsonov AA, Block WF. Characterizing and correcting gradient errors in non-Cartesian imaging: are gradient errors linear timeinvariant (LTI)? Magn Reson Med 2009;62:1466-1476.
    • (2009) Magn Reson Med , vol.62 , pp. 1466-1476
    • Brodsky, E.K.1    Samsonov, A.A.2    Block, W.F.3
  • 26
    • 0027539558 scopus 로고
    • Discrete time techniques for time delay estimation
    • DOI 10.1109/78.193195
    • Jacovitti G, Scarano G. Discrete time techniques for time delay estimation. IEEE Trans Signal Process 1993;41:525-533. (Pubitemid 23609320)
    • (1993) IEEE Transactions on Signal Processing , vol.41 , Issue.2 , pp. 525-533
    • Jacovith, G.1    Scarano, G.2
  • 27
    • 20744459613 scopus 로고    scopus 로고
    • Rapid gridding reconstruction with a minimal oversampling ratio
    • DOI 10.1109/TMI.2005.848376
    • Beatty PJ, Nishimura DG, Pauly JM. Rapid gridding reconstruction with a minimal oversampling ratio. IEEE Trans Med Imaging 2005;24:799-808. (Pubitemid 40850531)
    • (2005) IEEE Transactions on Medical Imaging , vol.24 , Issue.6 , pp. 799-808
    • Beatty, P.J.1    Nishimura, D.G.2    Pauly, J.M.3
  • 28
    • 60549094819 scopus 로고    scopus 로고
    • Convolution kernel design and efficient algorithm for sampling density correction
    • Johnson KO, Pipe JG. Convolution kernel design and efficient algorithm for sampling density correction. Magn Reson Med 2009;61:439-447.
    • (2009) Magn Reson Med , vol.61 , pp. 439-447
    • Johnson, K.O.1    Pipe, J.G.2
  • 29
    • 79960588866 scopus 로고    scopus 로고
    • Fast concomitant gradient field and field inhomogeneity correction for spiral cardiac imaging
    • Cheng JY, Santos JM, Pauly JM. Fast concomitant gradient field and field inhomogeneity correction for spiral cardiac imaging. Magn Reson Med 2011;66:390-401.
    • (2011) Magn Reson Med , vol.66 , pp. 390-401
    • Cheng, J.Y.1    Santos, J.M.2    Pauly, J.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.