메뉴 건너뛰기




Volumn 53, Issue 1, 2005, Pages 126-133

Analysis and correction of gradient nonlinearity and B0 inhomogeneity related scaling errors in two-dimensional phase contrast flow measurements

Author keywords

Flow quantification; Gradient nonlinearity; Hemodialysis; Image distortion; Phase contrast imaging

Indexed keywords

PHANTOMS;

EID: 12144274440     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20309     Document Type: Article
Times cited : (19)

References (20)
  • 1
    • 0030015095 scopus 로고    scopus 로고
    • Analysis of noise in phase contrast MR imaging
    • Andersen AH, Kirsch JE. Analysis of noise in phase contrast MR imaging. Med Phys 1996;23:857-869.
    • (1996) Med Phys , vol.23 , pp. 857-869
    • Andersen, A.H.1    Kirsch, J.E.2
  • 2
    • 0032950758 scopus 로고    scopus 로고
    • Construction of a protocol for measuring blood flow by two-dimensional phase-contrast MRA
    • Bakker CJG, Hoogeveen RM, Viergever MA. Construction of a protocol for measuring blood flow by two-dimensional phase-contrast MRA. J Magn Reson Imaging 1999;9:119-127.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 119-127
    • Bakker, C.J.G.1    Hoogeveen, R.M.2    Viergever, M.A.3
  • 3
    • 0028840250 scopus 로고
    • Accuracy and precision of time-averaged flow as measured by nontriggered 2D phase-contrast MR angiography, a phantom evaluation
    • Bakker CJG, Kouwenhoven M, Hartkamp MJ, Hoogeveen RM, Mali WPTM. Accuracy and precision of time-averaged flow as measured by nontriggered 2D phase-contrast MR angiography, a phantom evaluation. Magn Reson Imaging 1995;13:959-965.
    • (1995) Magn Reson Imaging , vol.13 , pp. 959-965
    • Bakker, C.J.G.1    Kouwenhoven, M.2    Hartkamp, M.J.3    Hoogeveen, R.M.4    Mali, W.P.T.M.5
  • 4
    • 0026750480 scopus 로고
    • Factors influencing the accuracy and precision of velocity-encoded phase imaging
    • Buonocore MH, Bogren H. Factors influencing the accuracy and precision of velocity-encoded phase imaging. Magn Reson Med 1992;26:141-154.
    • (1992) Magn Reson Med , vol.26 , pp. 141-154
    • Buonocore, M.H.1    Bogren, H.2
  • 5
    • 0036134296 scopus 로고    scopus 로고
    • Effect of acquisition parameters on the accuracy of velocity encoded cine magnetic resonance imaging blood flow measurements
    • Greil G, Geva T, Maier SE, Powell AJ. Effect of acquisition parameters on the accuracy of velocity encoded cine magnetic resonance imaging blood flow measurements. J Magn Reson Imaging 2002;15:47-54.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 47-54
    • Greil, G.1    Geva, T.2    Maier, S.E.3    Powell, A.J.4
  • 6
    • 0034880814 scopus 로고    scopus 로고
    • Quantitative analysis of PC MRI velocity maps: Pulsatile flow in cylindrical vessels
    • Robertson MB, Köhler U, Hoskins PR, Marshall I. Quantitative analysis of PC MRI velocity maps: pulsatile flow in cylindrical vessels. Magn Reson Imaging 2001;19:685-695.
    • (2001) Magn Reson Imaging , vol.19 , pp. 685-695
    • Robertson, M.B.1    Köhler, U.2    Hoskins, P.R.3    Marshall, I.4
  • 7
    • 0027564412 scopus 로고
    • Accuracy of phase-contrast flow measurements in the presence of partial-volume effects
    • Tang C, Blatter DD, Parker DL. Accuracy of phase-contrast flow measurements in the presence of partial-volume effects. J Magn Reson Imaging 1993;3:377-385.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 377-385
    • Tang, C.1    Blatter, D.D.2    Parker, D.L.3
  • 8
    • 0027254511 scopus 로고
    • Analysis of systematic and random error in MR volumetric flow measurements
    • Wolf RL, Ehman RL, Riederer SJ, Rossman PJ. Analysis of systematic and random error in MR volumetric flow measurements. Magn Reson Med 1993;30:82-91.
    • (1993) Magn Reson Med , vol.30 , pp. 82-91
    • Wolf, R.L.1    Ehman, R.L.2    Riederer, S.J.3    Rossman, P.J.4
  • 14
    • 0030013529 scopus 로고    scopus 로고
    • The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds
    • Schenck JF. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys 1996;23:815-850.
    • (1996) Med Phys , vol.23 , pp. 815-850
    • Schenck, J.F.1
  • 15
    • 0026688913 scopus 로고
    • Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging
    • Bakker CJG, Moerland MA, Bhagwandien R, Beersma R. Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging. Magn Reson Imaging 1992;10:597-608.
    • (1992) Magn Reson Imaging , vol.10 , pp. 597-608
    • Bakker, C.J.G.1    Moerland, M.A.2    Bhagwandien, R.3    Beersma, R.4
  • 17
    • 0032158660 scopus 로고    scopus 로고
    • Endovascular interventional MR: Balloon angioplasty in a hemodialysis access flow phantom
    • Smits HFM, Bos C, Van der Weide R, Bakker CJG. Endovascular interventional MR: balloon angioplasty in a hemodialysis access flow phantom. J Vasc Interv Radiol 1998;9:840-845.
    • (1998) J Vasc Interv Radiol , vol.9 , pp. 840-845
    • Smits, H.F.M.1    Bos, C.2    Van Der Weide, R.3    Bakker, C.J.G.4
  • 20
    • 0032919570 scopus 로고    scopus 로고
    • How to identify the haemodialysis access at risk of thrombosis? Are flow measurements the answer?
    • Blankestijn PJ, Smits JHM. How to identify the haemodialysis access at risk of thrombosis? Are flow measurements the answer? Nephrol Dial Transplant 1999;14:1068-1071.
    • (1999) Nephrol Dial Transplant , vol.14 , pp. 1068-1071
    • Blankestijn, P.J.1    Smits, J.H.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.