메뉴 건너뛰기




Volumn 6, Issue , 2016, Pages

A wearable biochemical sensor for monitoring alcohol consumption lifestyle through Ethyl glucuronide (EtG) detection in human sweat

Author keywords

[No Author keywords available]

Indexed keywords

ALCOHOL; BIOLOGICAL MARKER; ETHYL GLUCURONIDE; GLUCURONIC ACID;

EID: 84961773087     PISSN: None     EISSN: 20452322     Source Type: Journal    
DOI: 10.1038/srep23111     Document Type: Article
Times cited : (125)

References (53)
  • 1
    • 84882253811 scopus 로고    scopus 로고
    • Alcohol use disorders and mortality: A systematic review and meta-analysis
    • Roerecke, M., Rehm, J. Alcohol use disorders and mortality: a systematic review and meta-analysis. Addiction 108, 1562-1578, doi: 10.1111/add.12231 (2013).
    • (2013) Addiction , vol.108 , pp. 1562-1578
    • Roerecke, M.1    Rehm, J.2
  • 2
    • 84960086254 scopus 로고    scopus 로고
    • Decompensated alcohol related liver disease: Acute management
    • McPherson, S., Lucey, M. R., Moriarty, K. J. Decompensated alcohol related liver disease: acute management. BMJ 352, i124 (2016).
    • (2016) BMJ , vol.352 , pp. i124
    • McPherson, S.1    Lucey, M.R.2    Moriarty, K.J.3
  • 4
    • 34848832526 scopus 로고    scopus 로고
    • The role of biomarkers in the treatment of alcohol use disorders 2012 Revision
    • Substance Abuse and Mental Health Services Administration 2012 Newsletter
    • Substance Abuse and Mental Health Services Administration 2012 Newsletter. The Role of Biomarkers in the Treatment of Alcohol Use Disorders, 2012 Revision. Advisory, 11(2), 1-8 (2012).
    • (2012) Advisory , vol.11 , Issue.2 , pp. 1-8
  • 5
    • 84938061997 scopus 로고    scopus 로고
    • Determination of direct alcohol markers: A review
    • Cabarcos, P., lvarez, I., Tabernero, M., Bermejo, A. Determination of direct alcohol markers: a review. Anal Bioanal Chem 407, 4907-4925, doi: 10.1007/s00216-015-8701-7 (2015).
    • (2015) Anal Bioanal Chem , vol.407 , pp. 4907-4925
    • Cabarcos, P.1    Lvarez, I.2    Tabernero, M.3    Bermejo, A.4
  • 6
    • 84865092441 scopus 로고    scopus 로고
    • Determination of maternal-fetal biomarkers of prenatal exposure to ethanol: A review
    • Joya, X. et al. Determination of maternal-fetal biomarkers of prenatal exposure to ethanol: A review. J.Pharm Biomed Anal 69, 209-222 (2012).
    • (2012) J.Pharm Biomed Anal , vol.69 , pp. 209-222
    • Joya, X.1
  • 7
    • 67651009609 scopus 로고    scopus 로고
    • Biomarker Characteristics of Alcohol Use in the U.S
    • Lande, R. G., Marin, B. Biomarker Characteristics of Alcohol Use in the U.S. Army. J. Addict Dis 28, 158-163, doi: 10.1080/10550880902772506 (2009).
    • (2009) Army. J. Addict Dis , vol.28 , pp. 158-163
    • Lande, R.G.1    Marin, B.2
  • 8
    • 80051794263 scopus 로고    scopus 로고
    • Evaluation of ethyl glucuronide immunoassay urinalysis in five alcohol dependent outpatients
    • McDonell, M. G. et al. Evaluation of Ethyl Glucuronide Immunoassay Urinalysis in Five Alcohol Dependent Outpatients. Am J. Addict. 20, 482-484, doi: 10.1111/j.1521-0391.2011.00157.x (2011).
    • (2011) Am J. Addict. , vol.20 , pp. 482-484
    • McDonell, M.G.1
  • 9
    • 80055035872 scopus 로고    scopus 로고
    • Urinary ethyl glucuronide as a novel screening tool in patients pre-and post-liver transplantation improves detection of alcohol consumption
    • Staufer, K. et al. Urinary ethyl glucuronide as a novel screening tool in patients pre-and post-liver transplantation improves detection of alcohol consumption. Hepatology 54, 1640-1649, doi: 10.1002/hep.24596 (2011).
    • (2011) Hepatology , vol.54 , pp. 1640-1649
    • Staufer, K.1
  • 10
    • 84857063283 scopus 로고    scopus 로고
    • Biotransformation of ethanol to ethyl glucuronide in a rat model after a single high oral dosage
    • Wright, T. H., Ferslew, K. E. Biotransformation of ethanol to ethyl glucuronide in a rat model after a single high oral dosage. Alcohol 46, 159-164 (2012).
    • (2012) Alcohol , vol.46 , pp. 159-164
    • Wright, T.H.1    Ferslew, K.E.2
  • 12
    • 84867921274 scopus 로고    scopus 로고
    • Alcohol metabolism
    • Cederbaum, A. I. Alcohol metabolism. Clin liver dis. 16, 667-685 (2012).
    • (2012) Clin Liver Dis. , vol.16 , pp. 667-685
    • Cederbaum, A.I.1
  • 13
    • 0035178711 scopus 로고    scopus 로고
    • Research advances in ethanol metabolism
    • Ramchandani, V., Bosron, W., Li, T. Research advances in ethanol metabolism. Pathol Biol. 49, 676-682 (2001).
    • (2001) Pathol Biol. , vol.49 , pp. 676-682
    • Ramchandani, V.1    Bosron, W.2    Li, T.3
  • 14
    • 77952916485 scopus 로고    scopus 로고
    • Clinical (Non-forensic) Application of Ethylglucuronide measurement: Are we ready
    • Jatlow, P., O'Malley, S. S. Clinical (Non-forensic) Application Of Ethylglucuronide Measurement: Are We Ready Alcohol Clin Exp Res. 34, 968-975, doi: 10.1111/j.1530-0277.2010.01171.x (2010).
    • (2010) Alcohol Clin Exp Res. , vol.34 , pp. 968-975
    • Jatlow, P.1    O'Malley, S.S.2
  • 15
    • 84904391103 scopus 로고    scopus 로고
    • Ethyl glucuronide and ethyl sulfate assays in clinical trials, interpretation, and limitations: Results of a dose ranging alcohol challenge study and 2 clinical trials
    • Jatlow, P. I. et al. Ethyl glucuronide and ethyl sulfate assays in clinical trials, interpretation, and limitations: results of a dose ranging alcohol challenge study and 2 clinical trials. Alcohol Clin Exp Res. 38, 2056-2065 (2014).
    • (2014) Alcohol Clin Exp Res. , vol.38 , pp. 2056-2065
    • Jatlow, P.I.1
  • 16
    • 84890196804 scopus 로고    scopus 로고
    • Hair ethyl glucuronide levels as a marker for alcohol use and abuse: A review of the current state of the art
    • Crunelle, C. L. et al. Hair ethyl glucuronide levels as a marker for alcohol use and abuse: a review of the current state of the art. Drug Alcohol Depend. 134, 1-11 (2014).
    • (2014) Drug Alcohol Depend. , vol.134 , pp. 1-11
    • Crunelle, C.L.1
  • 17
    • 77749341061 scopus 로고    scopus 로고
    • Levels of ethyl glucuronide and ethyl sulfate in oral fluid, blood, and urine after use of mouthwash and ingestion of nonalcoholic wine
    • Hseth, G., Yttredal, B., Karinen, R., Gjerde, H., Christophersen, A. Levels of ethyl glucuronide and ethyl sulfate in oral fluid, blood, and urine after use of mouthwash and ingestion of nonalcoholic wine. J. Anal Toxicol. 34(2), 84-88 (2010).
    • (2010) J. Anal Toxicol. , vol.34 , Issue.2 , pp. 84-88
    • Hseth, G.1    Yttredal, B.2    Karinen, R.3    Gjerde, H.4    Christophersen, A.5
  • 18
    • 77954892571 scopus 로고    scopus 로고
    • Ethyl glucuronide concentrations in oral fluid, blood, and urine after volunteers drank 0.5 and 1.0 g/kg doses of ethanol
    • Hseth, G. et al. Ethyl glucuronide concentrations in oral fluid, blood, and urine after volunteers drank 0.5 and 1.0 g/kg doses of ethanol. J. Anal Toxicol. 34, 319-324 (2010).
    • (2010) J. Anal Toxicol. , vol.34 , pp. 319-324
    • Hseth, G.1
  • 19
    • 67349091102 scopus 로고    scopus 로고
    • Blood kinetics of ethyl glucuronide and ethyl sulphate in heavy drinkers during alcohol detoxification
    • Hseth, G., Morini, L., Polettini, A., Christophersen, A., Mland, J. Blood kinetics of ethyl glucuronide and ethyl sulphate in heavy drinkers during alcohol detoxification. Forensic Sci Int. 188, 52-56 (2009).
    • (2009) Forensic Sci Int. , vol.188 , pp. 52-56
    • Hseth, G.1    Morini, L.2    Polettini, A.3    Christophersen, A.4    Mland, J.5
  • 20
    • 84871988548 scopus 로고    scopus 로고
    • Sensitivity and specificity of urinary ethyl glucuronide and ethyl sulfate in liver disease patients
    • Stewart, S. H., Koch, D. G., Burgess, D. M., Willner, I. R., Reuben, A. Sensitivity and specificity of urinary ethyl glucuronide and ethyl sulfate in liver disease patients. Alcohol Clin Exp Res. 37, 150-155 (2013).
    • (2013) Alcohol Clin Exp Res. , vol.37 , pp. 150-155
    • Stewart, S.H.1    Koch, D.G.2    Burgess, D.M.3    Willner, I.R.4    Reuben, A.5
  • 21
    • 84950975737 scopus 로고    scopus 로고
    • Using ethyl glucuronide in urine to detect light and heavy drinking in alcohol dependent outpatients
    • McDonell, M. G. et al. Using ethyl glucuronide in urine to detect light and heavy drinking in alcohol dependent outpatients. Drug Alcohol Depend. 157, 184-187 (2015).
    • (2015) Drug Alcohol Depend. , vol.157 , pp. 184-187
    • McDonell, M.G.1
  • 22
    • 84961779744 scopus 로고    scopus 로고
    • Ethyl glucuronide concentrations in hair: A controlled alcohol-dosing study in healthy volunteers
    • Crunelle, C. L. et al. Ethyl glucuronide concentrations in hair: a controlled alcohol-dosing study in healthy volunteers. Anal Bioanal Chem, 1-7 (2015).
    • (2015) Anal Bioanal Chem , pp. 1-7
    • Crunelle, C.L.1
  • 23
    • 84871596030 scopus 로고    scopus 로고
    • Hair ethyl glucuronide is highly sensitive and specific for detecting moderate-to-heavy drinking in patients with liver disease
    • Stewart, S. H., Koch, D. G., Willner, I. R., Randall, P. K., Reuben, A. Hair ethyl glucuronide is highly sensitive and specific for detecting moderate-to-heavy drinking in patients with liver disease. Alcohol Alcohol. 48, 83-87 (2013).
    • (2013) Alcohol Alcohol. , vol.48 , pp. 83-87
    • Stewart, S.H.1    Koch, D.G.2    Willner, I.R.3    Randall, P.K.4    Reuben, A.5
  • 24
    • 65749117506 scopus 로고    scopus 로고
    • Ethylglucuronide determination in urine and hair from alcohol withdrawal patients
    • Concheiro, M. et al. Ethylglucuronide determination in urine and hair from alcohol withdrawal patients. J. Anal Toxicol. 33, 155-161 (2009).
    • (2009) J. Anal Toxicol. , vol.33 , pp. 155-161
    • Concheiro, M.1
  • 25
    • 84859905662 scopus 로고    scopus 로고
    • A review of wearable sensors and systems with application in rehabilitation
    • Patel, S., Park, H., Bonato, P., Chan, L., Rodgers, M. A review of wearable sensors and systems with application in rehabilitation. J. Neuroeng Rehabil. 9, 1-17 (2012).
    • (2012) J. Neuroeng Rehabil. , vol.9 , pp. 1-17
    • Patel, S.1    Park, H.2    Bonato, P.3    Chan, L.4    Rodgers, M.5
  • 26
    • 73049087409 scopus 로고    scopus 로고
    • A survey on wearable sensor-Based systems for health monitoring and prognosis. Systems man and cybernetics Part C: Applications and reviews
    • Pantelopoulos, A., Bourbakis, N. G. A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis. Systems, Man, and Cybernetics, Part C: Applications and Reviews, IEEE Transactions on 40, 1-12, doi: 10.1109/TSMCC.2009.2032660 (2010).
    • (2010) IEEE Transactions on , vol.40 , pp. 1-12
    • Pantelopoulos, A.1    Bourbakis, N.G.2
  • 27
    • 84893862009 scopus 로고    scopus 로고
    • A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
    • Gong, S. et al. A wearable and highly sensitive pressure sensor with ultrathin gold nanowires. Nat Commun 5, doi: 10.1038/ncomms4132 (2014).
    • (2014) Nat Commun , vol.5
    • Gong, S.1
  • 28
    • 84961824017 scopus 로고    scopus 로고
    • Available at (Accessed: 16th October 2015
    • Gebel, E., Anatomy of a test strip. (2012) Available at : http://www.diabetesforecast.org/2012/jul/anatomy-of-a-test-strip.html. (Accessed: 16th October 2015).
    • (2012) Anatomy of A Test Strip
    • Gebel, E.1
  • 29
    • 0004878656 scopus 로고
    • Bonds and bands in semiconductors
    • Phillips, J. C. Bonds and Bands in Semiconductors. Science 169, 1035, doi: 10.1126/science.169.3950.1035 (1970).
    • (1970) Science , vol.169 , pp. 1035
    • Phillips, J.C.1
  • 30
    • 0037108349 scopus 로고    scopus 로고
    • Printed plastic electronics and paperlike displays
    • Rogers, J. A., Bao, Z. Printed plastic electronics and paperlike displays. J. Polym. Sci. A Polym. Chem. 40, 3327-3334, doi: 10.1002/pola.10405 (2002).
    • (2002) J. Polym. Sci. A Polym. Chem. , vol.40 , pp. 3327-3334
    • Rogers, J.A.1    Bao, Z.2
  • 31
    • 84921450607 scopus 로고    scopus 로고
    • Flexible organic electrochemical transistors for highly selective enzyme biosensors and used for saliva testing
    • Liao, C., Mak, C., Zhang, M., Chan, H. L., Yan, F. Flexible organic electrochemical transistors for highly selective enzyme biosensors and used for saliva testing. Adv Mater. 27, 676-681 (2015).
    • (2015) Adv Mater. , vol.27 , pp. 676-681
    • Liao, C.1    Mak, C.2    Zhang, M.3    Chan, H.L.4    Yan, F.5
  • 32
    • 84924709447 scopus 로고    scopus 로고
    • Paper and flexible substrates as materials for biosensing platforms to detect multiple biotargets
    • Shafiee, H. et al. Paper and flexible substrates as materials for biosensing platforms to detect multiple biotargets. Sci Rep. 5, doi: 10.1038/srep08719 (2015).
    • (2015) Sci Rep. , vol.5
    • Shafiee, H.1
  • 34
    • 84922471125 scopus 로고    scopus 로고
    • Printed and flexible biosensor for antioxidants using interdigitated ink-jetted electrodes and gravure-deposited active layer
    • Pavinatto, F. J., Paschoal, C. W., Arias, A. C. Printed and flexible biosensor for antioxidants using interdigitated ink-jetted electrodes and gravure-deposited active layer. Biosens Bioelectron. 67, 553-559 (2015).
    • (2015) Biosens Bioelectron. , vol.67 , pp. 553-559
    • Pavinatto, F.J.1    Paschoal, C.W.2    Arias, A.C.3
  • 35
    • 84879728517 scopus 로고    scopus 로고
    • Impedimetric immunosensor based on gold nanoparticles modified graphene paper for label-free detection of Escherichia coli O157: H7
    • Wang, Y., Ping, J., Ye, Z., Wu, J., Ying, Y. Impedimetric immunosensor based on gold nanoparticles modified graphene paper for label-free detection of Escherichia coli O157: H7. Biosens Bioelectron. 49, 492-498 (2013).
    • (2013) Biosens Bioelectron. , vol.49 , pp. 492-498
    • Wang, Y.1    Ping, J.2    Ye, Z.3    Wu, J.4    Ying, Y.5
  • 36
    • 84921293811 scopus 로고    scopus 로고
    • High loading MnO2 nanowires on graphene paper: Facile electrochemical synthesis and use as flexible electrode for tracking hydrogen peroxide secretion in live cells
    • Dong, S. et al. High loading MnO2 nanowires on graphene paper: facile electrochemical synthesis and use as flexible electrode for tracking hydrogen peroxide secretion in live cells. Anal Chim Acta. 853, 200-206 (2015).
    • (2015) Anal Chim Acta. , vol.853 , pp. 200-206
    • Dong, S.1
  • 37
    • 84871581774 scopus 로고    scopus 로고
    • Nanosensor electrical immunoassay for quantitative detection of NT-pro brain natriuretic peptide
    • Panneer Selvam, A., Prasad, S. Nanosensor electrical immunoassay for quantitative detection of NT-pro brain natriuretic peptide. Future Cardiol. 9, 137-147 (2013).
    • (2013) Future Cardiol. , vol.9 , pp. 137-147
    • Panneer Selvam, A.1    Prasad, S.2
  • 38
    • 84940530555 scopus 로고    scopus 로고
    • Electrical nanowell diagnostics sensors for rapid and ultrasensitive detection of prostate-specific antigen
    • Panneer Selvam, A., Prasad, S., Barrett, T. W., Kazmierczak, S. C. Electrical nanowell diagnostics sensors for rapid and ultrasensitive detection of prostate-specific antigen. Nanomedicine 10, 2527-2536 (2015).
    • (2015) Nanomedicine , vol.10 , pp. 2527-2536
    • Panneer Selvam, A.1    Prasad, S.2    Barrett, T.W.3    Kazmierczak, S.C.4
  • 40
    • 34547578768 scopus 로고    scopus 로고
    • Labelfree impedance biosensors: Opportunities and challenges
    • Daniels, J. S., Pourmand, N. Labelfree impedance biosensors: Opportunities and challenges. Electroanalysis 19, 1239-1257 (2007).
    • (2007) Electroanalysis , vol.19 , pp. 1239-1257
    • Daniels, J.S.1    Pourmand, N.2
  • 42
    • 38849098376 scopus 로고    scopus 로고
    • A Gouy-Chapman-Stern model of the double layer at a (metal)/(ionic liquid) interface
    • Oldham, K. B. A Gouy-Chapman-Stern model of the double layer at a (metal)/(ionic liquid) interface. J. Electroanal Chem. 613, 131-138 (2008).
    • (2008) J. Electroanal Chem. , vol.613 , pp. 131-138
    • Oldham, K.B.1
  • 43
    • 21844466991 scopus 로고    scopus 로고
    • Impedance characterization and modeling of electrodes for biomedical applications
    • Franks, W., Schenker, I., Schmutz, P., Hierlemann, A. Impedance characterization and modeling of electrodes for biomedical applications. Biomedical Engineering, IEEE Transactions on 52, 1295-1302, doi: 10.1109/TBME.2005.847523 (2005).
    • (2005) Biomedical Engineering IEEE Transactions on , vol.52 , pp. 1295-1302
    • Franks, W.1    Schenker, I.2    Schmutz, P.3    Hierlemann, A.4
  • 44
    • 58149106226 scopus 로고    scopus 로고
    • Quantitative determination of ethyl glucuronide in sweat
    • Schummer, C., Appenzeller, B. M., Wennig, R. Quantitative determination of ethyl glucuronide in sweat. Ther Drug Monit. 30, 536-539 (2008).
    • (2008) Ther Drug Monit. , vol.30 , pp. 536-539
    • Schummer, C.1    Appenzeller, B.M.2    Wennig, R.3
  • 45
    • 84961802990 scopus 로고    scopus 로고
    • Alcohol and Public Health Available at (Accessed: 16th October 2015
    • Alcohol and Public Health., (2015), Available at: http://www.cdc.gov/alcohol/. (Accessed: 16th October 2015).
    • (2015)
  • 46
    • 84914689387 scopus 로고    scopus 로고
    • Flexible gold electrode array for multiplexed immunoelectrochemical measurement of three protein biomarkers for prostate cancer
    • Liu, J., Lu, C.-Y., Zhou, H., Xu, J.-J., Chen, H.-Y. Flexible gold electrode array for multiplexed immunoelectrochemical measurement of three protein biomarkers for prostate cancer. ACS applied materials & interfaces 6, 20137-20143 (2014).
    • (2014) ACS Applied Materials & Interfaces , vol.6 , pp. 20137-20143
    • Liu, J.1    Lu, C.-Y.2    Zhou, H.3    Xu, J.-J.4    Chen, H.-Y.5
  • 47
    • 84867766682 scopus 로고    scopus 로고
    • Gold nanostructures on flexible substrates as electrochemical dopamine sensors
    • Hsu, M.-S., Chen, Y.-L., Lee, C.-Y., Chiu, H.-T. Gold nanostructures on flexible substrates as electrochemical dopamine sensors. ACS Appl Mater Interfaces. 4, 5570-5575 (2012).
    • (2012) ACS Appl Mater Interfaces. , vol.4 , pp. 5570-5575
    • Hsu, M.-S.1    Chen, Y.-L.2    Lee, C.-Y.3    Chiu, H.-T.4
  • 48
    • 84882334474 scopus 로고    scopus 로고
    • Electrical biosensors and the label free detection of protein disease biomarkers
    • Luo, X., Davis, J. J. Electrical biosensors and the label free detection of protein disease biomarkers. Chem Soc Rev. 42, 5944-5962 (2013).
    • (2013) Chem Soc Rev. , vol.42 , pp. 5944-5962
    • Luo, X.1    Davis, J.J.2
  • 49
    • 84887154534 scopus 로고    scopus 로고
    • An electrochemical biosensor with nanointerface for lactate detection based on lactate dehydrogenase immobilized on zinc oxide nanorods
    • Nesakumar, N., Thandavan, K., Sethuraman, S., Krishnan, U. M., Rayappan, J. B. B. An electrochemical biosensor with nanointerface for lactate detection based on lactate dehydrogenase immobilized on zinc oxide nanorods. J. Colloid Interface Sci. 414, 90-96 (2014).
    • (2014) J. Colloid Interface Sci. , vol.414 , pp. 90-96
    • Nesakumar, N.1    Thandavan, K.2    Sethuraman, S.3    Krishnan, U.M.4    Rayappan, J.B.B.5
  • 50
    • 84927926275 scopus 로고    scopus 로고
    • Anti-epidermal growth factor receptor conjugated mesoporous zinc oxide nanofibers for breast cancer diagnostics
    • Ali, M. A., Mondal, K., Singh, C., Malhotra, B. D., Sharma, A. Anti-epidermal growth factor receptor conjugated mesoporous zinc oxide nanofibers for breast cancer diagnostics. Nanoscale 7, 7234-7245 (2015).
    • (2015) Nanoscale , vol.7 , pp. 7234-7245
    • Ali, M.A.1    Mondal, K.2    Singh, C.3    Malhotra, B.D.4    Sharma, A.5
  • 51
    • 78049300950 scopus 로고    scopus 로고
    • Potentiometric cholesterol biosensor based on ZnO nanorods chemically grown on Ag wire
    • Israr, M. Q. et al. Potentiometric cholesterol biosensor based on ZnO nanorods chemically grown on Ag wire. Thin Solid Films 519, 1106-1109 (2010).
    • (2010) Thin Solid Films , vol.519 , pp. 1106-1109
    • Israr, M.Q.1
  • 52
    • 77957652345 scopus 로고    scopus 로고
    • High-performance flexible enzymatic glucose biosensor based on ZnO nanowires supported on a gold-coated polyester substrate
    • Pradhan, D., Niroui, F., Leung, K. High-performance, flexible enzymatic glucose biosensor based on ZnO nanowires supported on a gold-coated polyester substrate. ACS Appl Mater Interfaces. 2, 2409-2412 (2010).
    • (2010) ACS Appl Mater Interfaces. , vol.2 , pp. 2409-2412
    • Pradhan, D.1    Niroui, F.2    Leung, K.3
  • 53
    • 84890624206 scopus 로고    scopus 로고
    • Ultra-sensitive electrical immunoassay biosensors using nanotextured zinc oxide thin films on printed circuit board platforms
    • Jacobs, M., Muthukumar, S., Panneer Selvam, A., Engel Craven, J., Prasad, S. Ultra-sensitive electrical immunoassay biosensors using nanotextured zinc oxide thin films on printed circuit board platforms. Biosens Bioelectron. 55, 7-13 (2014).
    • (2014) Biosens Bioelectron. , vol.55 , pp. 7-13
    • Jacobs, M.1    Muthukumar, S.2    Panneer Selvam, A.3    Engel Craven, J.4    Prasad, S.5