메뉴 건너뛰기




Volumn 25, Issue 6, 2016, Pages 1706-1715

A comparative study on the accuracy of pedicle screw placement assisted by personalized rapid prototyping template between pre- and post-operation in patients with relatively normal mid-upper thoracic spine

Author keywords

Pedicle screw; Personalized drill template; Post pre registration; Rapid prototyping; Thoracic

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; BONE DRILL; COMPUTER ASSISTED TOMOGRAPHY; DRILL GUIDE; FEMALE; FOLLOW UP; HUMAN; INTERMETHOD COMPARISON; KIRSCHNER WIRE; MAJOR CLINICAL STUDY; MALE; MEDICAL RECORD REVIEW; PEDICLE SCREW; PRIORITY JOURNAL; PSEUDARTHROSIS; RAPID PROTOTYPING TEMPLATE TECHNIQUE; SURGICAL TECHNIQUE; THORACIC VERTEBRA; WOUND DEHISCENCE; COMPARATIVE STUDY; COMPUTER ASSISTED SURGERY; DIAGNOSTIC IMAGING; MIDDLE AGED; ORTHOPEDIC SURGERY; PROCEDURES; STATISTICS AND NUMERICAL DATA; SURGERY; X-RAY COMPUTED TOMOGRAPHY;

EID: 84961575110     PISSN: 09406719     EISSN: 14320932     Source Type: Journal    
DOI: 10.1007/s00586-016-4540-2     Document Type: Article
Times cited : (23)

References (39)
  • 1
    • 0033794424 scopus 로고    scopus 로고
    • The use of pedicle-screw internal fixation for the operative treatment of spinal disorders
    • Gaines Jr RW (2000) The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82:1458–1476
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 1458-1476
    • Gaines Jr, R.W.1
  • 2
    • 84908128710 scopus 로고    scopus 로고
    • Safety and efficacy of pedicle screw placement using intraoperative computed tomography: consecutive series of 1148 pedicle screws
    • PID: 24926927
    • Bydon M, Xu R, Amin AG et al (2014) Safety and efficacy of pedicle screw placement using intraoperative computed tomography: consecutive series of 1148 pedicle screws. J Neurosurg Spine 21:320–328
    • (2014) J Neurosurg Spine , vol.21 , pp. 320-328
    • Bydon, M.1    Xu, R.2    Amin, A.G.3
  • 3
    • 84893283617 scopus 로고    scopus 로고
    • Treatment of thoracolumbar trauma by short-segment percutaneous transpedicular screw instrumentation: prospective comparative study with a minimum 2-year follow-up
    • PID: 24358996
    • Vanek P, Bradac O, Konopkova R et al (2014) Treatment of thoracolumbar trauma by short-segment percutaneous transpedicular screw instrumentation: prospective comparative study with a minimum 2-year follow-up. J Neurosurg Spine 20:150–156
    • (2014) J Neurosurg Spine , vol.20 , pp. 150-156
    • Vanek, P.1    Bradac, O.2    Konopkova, R.3
  • 4
    • 0036570533 scopus 로고    scopus 로고
    • Axial and tangential fixation strength of pedicle screws versus hooks in the thoracic spine in relation to bone mineral density
    • PID: 11979165
    • Hackenberg L, Link T, Liljenqvist U (2002) Axial and tangential fixation strength of pedicle screws versus hooks in the thoracic spine in relation to bone mineral density. Spine 27:937–942
    • (2002) Spine , vol.27 , pp. 937-942
    • Hackenberg, L.1    Link, T.2    Liljenqvist, U.3
  • 5
    • 0742269913 scopus 로고    scopus 로고
    • Direct vertebral rotation: a new technique of three-dimensional deformity correction with segmental pedicle screw fixation in adolescent idiopathic scoliosis
    • PID: 14752361
    • Lee SM, Suk SI, Chung ER (2004) Direct vertebral rotation: a new technique of three-dimensional deformity correction with segmental pedicle screw fixation in adolescent idiopathic scoliosis. Spine 29:343–349
    • (2004) Spine , vol.29 , pp. 343-349
    • Lee, S.M.1    Suk, S.I.2    Chung, E.R.3
  • 6
    • 25444504048 scopus 로고    scopus 로고
    • Thoracic adolescent idiopathic scoliosis curves between 70 degrees and 100 degrees: is anterior release necessary?
    • PID: 16166896
    • Luhmann SJ, Lenk LG, Kim YJ et al (2005) Thoracic adolescent idiopathic scoliosis curves between 70 degrees and 100 degrees: is anterior release necessary? Spine 30:2061–2067
    • (2005) Spine , vol.30 , pp. 2061-2067
    • Luhmann, S.J.1    Lenk, L.G.2    Kim, Y.J.3
  • 7
    • 33644877691 scopus 로고    scopus 로고
    • Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analysis
    • PID: 15803068
    • Rampersaud YRPJ, Salonen D, Farooq S (2005) Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analysis. Spine 30(7):E183–E190
    • (2005) Spine , vol.30 , Issue.7 , pp. E183-E190
    • Rampersaud, Y.R.P.J.1    Salonen, D.2    Farooq, S.3
  • 8
    • 0029156076 scopus 로고
    • Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the toracic vertebrae
    • COI: 1:STN:280:DyaK2MzntVehsw%3D%3D, PID: 7642664
    • Vaccaro AR, Rizzolo SJ, Allardyce TJ et al (1995) Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the toracic vertebrae. J Bone Joint Surg Am 77:1193–1199
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1193-1199
    • Vaccaro, A.R.1    Rizzolo, S.J.2    Allardyce, T.J.3
  • 9
    • 33746863269 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement for upper and middle thoracic pathologies without coronal plane spinal deformity using conventional methods
    • PID: 16891980
    • Guzey FK, Emel E, Hakan Seyithanoglu M et al (2006) Accuracy of pedicle screw placement for upper and middle thoracic pathologies without coronal plane spinal deformity using conventional methods. J Spinal Disord Tech 19:436–441
    • (2006) J Spinal Disord Tech , vol.19 , pp. 436-441
    • Guzey, F.K.1    Emel, E.2    Hakan Seyithanoglu, M.3
  • 10
    • 77957335306 scopus 로고    scopus 로고
    • Descending aortic injury by a thoracic pedicle screw during posterior reconstructive surgery: a case report
    • PID: 20802385
    • Watanabe K, Yamazaki A, Hirano T et al (2010) Descending aortic injury by a thoracic pedicle screw during posterior reconstructive surgery: a case report. Spine 35:E1064–E1068
    • (2010) Spine , vol.35 , pp. E1064-E1068
    • Watanabe, K.1    Yamazaki, A.2    Hirano, T.3
  • 11
    • 0034302165 scopus 로고    scopus 로고
    • Anatomic study of the cervicothoracic spinal nerves and their relation to the pedicles
    • COI: 1:STN:280:DC%2BD3cvptFGisw%3D%3D, PID: 11043961
    • Ebraheim NA, Tremains M, Xu R et al (2000) Anatomic study of the cervicothoracic spinal nerves and their relation to the pedicles. Am J Orthop 29:779–781
    • (2000) Am J Orthop , vol.29 , pp. 779-781
    • Ebraheim, N.A.1    Tremains, M.2    Xu, R.3
  • 12
    • 33846855301 scopus 로고    scopus 로고
    • Thoracic pedicle screw insertion in scoliosis using posteroanterior C-arm rotation method
    • PID: 17285055
    • Lee CS, Kim MJ, Ahn YJ et al (2007) Thoracic pedicle screw insertion in scoliosis using posteroanterior C-arm rotation method. J Spinal Disord Tech 20:66–71
    • (2007) J Spinal Disord Tech , vol.20 , pp. 66-71
    • Lee, C.S.1    Kim, M.J.2    Ahn, Y.J.3
  • 13
    • 34447506195 scopus 로고    scopus 로고
    • C-arm assessment of cervical pedicle screw: screw coaxial fluoroscopy and oblique view
    • PID: 17632392
    • Cha SH, Kim C, Choi BK et al (2007) C-arm assessment of cervical pedicle screw: screw coaxial fluoroscopy and oblique view. Spine 32:1721–1727
    • (2007) Spine , vol.32 , pp. 1721-1727
    • Cha, S.H.1    Kim, C.2    Choi, B.K.3
  • 14
    • 84886099106 scopus 로고    scopus 로고
    • Intraoperative con beam-computed tomography with navigation (O-ARM) versus conventional fluoroscopy (C-ARM): a cadaveric study comparing accuracy, efficiency, and safety for spinal instrumentation
    • PID: 23883830
    • Tabaraee E, Gibson AG, Karahalios DG et al (2013) Intraoperative con beam-computed tomography with navigation (O-ARM) versus conventional fluoroscopy (C-ARM): a cadaveric study comparing accuracy, efficiency, and safety for spinal instrumentation. Spine 38:1953–1958
    • (2013) Spine , vol.38 , pp. 1953-1958
    • Tabaraee, E.1    Gibson, A.G.2    Karahalios, D.G.3
  • 15
    • 84937163478 scopus 로고    scopus 로고
    • Prospective comparison study between the fluoroscopy guided and navigation coupled with O-arm-guided pedicle screw placement in the thoracic and lumbosacral spines
    • PID: 23563342
    • Shin MH, Hur JW, Ryu KS et al. (2015) Prospective comparison study between the fluoroscopy guided and navigation coupled with O-arm-guided pedicle screw placement in the thoracic and lumbosacral spines. J Spinal Disord Tech 28:E347–E351
    • (2015) J Spinal Disord Tech , vol.28 , pp. E347-E351
    • Shin, M.H.1    Hur, J.W.2    Ryu, K.S.3
  • 16
    • 84903820729 scopus 로고    scopus 로고
    • Deviation analysis of C1-C2 transarticular screw placement assisted by a novel rapid prototyping drill template: a cadaveric study
    • PID: 24525747
    • Hu Y, Yuan ZS, Kepler CK et al (2014) Deviation analysis of C1-C2 transarticular screw placement assisted by a novel rapid prototyping drill template: a cadaveric study. J Spinal Disord Tech 27:E181–E186
    • (2014) J Spinal Disord Tech , vol.27 , pp. E181-E186
    • Hu, Y.1    Yuan, Z.S.2    Kepler, C.K.3
  • 17
    • 84890488873 scopus 로고    scopus 로고
    • Deviation analysis of C2 translaminar screw placement assisted by a novel rapid prototyping drill template: a cadaveric study
    • PID: 24005997
    • Hu Y, Yuan ZS, Spiker WR et al (2013) Deviation analysis of C2 translaminar screw placement assisted by a novel rapid prototyping drill template: a cadaveric study. Eur Spine J 22:2770–2776
    • (2013) Eur Spine J , vol.22 , pp. 2770-2776
    • Hu, Y.1    Yuan, Z.S.2    Spiker, W.R.3
  • 18
    • 84857634695 scopus 로고    scopus 로고
    • A novel computer-assisted drill guide template for thoracic pedicle screw placement: a cadaveric study
    • PID: 21874371
    • Ma T, Xu YQ, Cheng YB et al (2012) A novel computer-assisted drill guide template for thoracic pedicle screw placement: a cadaveric study. Arch Orthop Trauma Surg 132:65–72
    • (2012) Arch Orthop Trauma Surg , vol.132 , pp. 65-72
    • Ma, T.1    Xu, Y.Q.2    Cheng, Y.B.3
  • 19
    • 84880170481 scopus 로고    scopus 로고
    • A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine
    • PID: 23632782
    • Merc M, Drstvensek I, Vogrin M, Brajlih T, Recnik G (2013) A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine. Arch Orthop Trauma Surg 133:893–899
    • (2013) Arch Orthop Trauma Surg , vol.133 , pp. 893-899
    • Merc, M.1    Drstvensek, I.2    Vogrin, M.3    Brajlih, T.4    Recnik, G.5
  • 20
    • 0031000936 scopus 로고    scopus 로고
    • Complexity of the thoracic spine pedicle anatomy
    • COI: 1:STN:280:DyaK2s3kslKqtA%3D%3D, PID: 9093823
    • Panjabi MM, O’Holleran JD, Crisco JJ 3rd et al (1997) Complexity of the thoracic spine pedicle anatomy. Eur Spine J 6:19–24
    • (1997) Eur Spine J , vol.6 , pp. 19-24
    • Panjabi, M.M.1    O’Holleran, J.D.2    Crisco, J.J.3
  • 21
    • 0742269914 scopus 로고    scopus 로고
    • Free hand pedicle screw placement in the thoracic spine: is it safe?
    • PID: 14752359
    • Kim YJ, Lenke LG, Bridwell KH et al (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 29:333–342
    • (2004) Spine , vol.29 , pp. 333-342
    • Kim, Y.J.1    Lenke, L.G.2    Bridwell, K.H.3
  • 22
    • 0025267440 scopus 로고
    • Accuracy of pedicular screw placement in vivo
    • COI: 1:STN:280:DyaK3c3itlWgtA%3D%3D, PID: 2326693
    • Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15:11–14
    • (1990) Spine , vol.15 , pp. 11-14
    • Gertzbein, S.D.1    Robbins, S.E.2
  • 23
    • 0027467685 scopus 로고
    • Location of transpedicular screws for fixation of the lower thoracic and lumbar spine. Computed tomography of 45 fracture cases
    • COI: 1:STN:280:DyaK3s7pvVGntw%3D%3D, PID: 8451940
    • Sim E (1993) Location of transpedicular screws for fixation of the lower thoracic and lumbar spine. Computed tomography of 45 fracture cases. Acta Orthop Scand 64:28–32
    • (1993) Acta Orthop Scand , vol.64 , pp. 28-32
    • Sim, E.1
  • 24
    • 0030926450 scopus 로고    scopus 로고
    • Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients
    • COI: 1:STN:280:DyaK2szksFCqug%3D%3D, PID: 9201865
    • Laine T, Schlenzka D, Makitalo K, Tallroth K, Nolte LP, Visarius H (1997) Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients. Spine 22:1254–1258
    • (1997) Spine , vol.22 , pp. 1254-1258
    • Laine, T.1    Schlenzka, D.2    Makitalo, K.3    Tallroth, K.4    Nolte, L.P.5    Visarius, H.6
  • 25
    • 45149096091 scopus 로고    scopus 로고
    • Pedicle screw placement with a free hand technique in thoracolumbar spine: is it safe?
    • PID: 18418139
    • Karapinar L, Erel N, Ozturk H, Altay T, Kaya A (2008) Pedicle screw placement with a free hand technique in thoracolumbar spine: is it safe? J Spinal Disord Tech 21:63–67
    • (2008) J Spinal Disord Tech , vol.21 , pp. 63-67
    • Karapinar, L.1    Erel, N.2    Ozturk, H.3    Altay, T.4    Kaya, A.5
  • 26
    • 64249146979 scopus 로고    scopus 로고
    • Accuracy of thoracic pedicle screw placement in scoliosis using the ideal pedicle entry point during the freehand technique
    • PID: 18357448
    • Modi H, Suh SW, Song HR, Yang JH (2009) Accuracy of thoracic pedicle screw placement in scoliosis using the ideal pedicle entry point during the freehand technique. Int Orthop 33:469–475
    • (2009) Int Orthop , vol.33 , pp. 469-475
    • Modi, H.1    Suh, S.W.2    Song, H.R.3    Yang, J.H.4
  • 27
    • 34248550738 scopus 로고    scopus 로고
    • Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization
    • PID: 16967297
    • Schizas C, Michel J, Kosmopoulos V, Theumann N (2007) Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization. Eur Spine J 16:613–617
    • (2007) Eur Spine J , vol.16 , pp. 613-617
    • Schizas, C.1    Michel, J.2    Kosmopoulos, V.3    Theumann, N.4
  • 28
    • 39649086715 scopus 로고    scopus 로고
    • Outcome-based classification for assessment of thoracic pedicular screw placement
    • PID: 18277869
    • Upendra BN, Meena D, Chowdhury B, Ahmad A, Jayaswal A (2008) Outcome-based classification for assessment of thoracic pedicular screw placement. Spine 33:384–390
    • (2008) Spine , vol.33 , pp. 384-390
    • Upendra, B.N.1    Meena, D.2    Chowdhury, B.3    Ahmad, A.4    Jayaswal, A.5
  • 29
    • 0022551914 scopus 로고
    • Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates
    • COI: 1:STN:280:DyaL287hvFOqtw%3D%3D, PID: 3945476
    • Roy-Camille R, Saillant G, Mazel C (1986) Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates. Orthop Clin North Am 17:147–159
    • (1986) Orthop Clin North Am , vol.17 , pp. 147-159
    • Roy-Camille, R.1    Saillant, G.2    Mazel, C.3
  • 30
    • 84922394553 scopus 로고    scopus 로고
    • Freehand thoracic pedicle screw technique using a uniform entry point and sagittal trajectory for all levels: prelimimary clinical experience
    • PID: 25147977
    • Fennell VS, Palejwala S, Skoch J et al. (2014) Freehand thoracic pedicle screw technique using a uniform entry point and sagittal trajectory for all levels: prelimimary clinical experience. J Neurosurg Spine 21:778–784
    • (2014) J Neurosurg Spine , vol.21 , pp. 778-784
    • Fennell, V.S.1    Palejwala, S.2    Skoch, J.3
  • 31
    • 34250806064 scopus 로고    scopus 로고
    • Thoracic pedicle screw placement: analysis using anatomical landmarks without image guidance
    • PID: 17585271
    • Elliott MJ, Slakey JB (2007) Thoracic pedicle screw placement: analysis using anatomical landmarks without image guidance. J Pediatr Orthop 27:582–586
    • (2007) J Pediatr Orthop , vol.27 , pp. 582-586
    • Elliott, M.J.1    Slakey, J.B.2
  • 32
    • 85027943084 scopus 로고    scopus 로고
    • Endovascular aortic injury repair after thoracic pedicle screw placement
    • COI: 1:STN:280:DC%2BC2cbitFSltw%3D%3D, PID: 25023930
    • Pesenti S, Bartoli MA, Blondel B et al (2014) Endovascular aortic injury repair after thoracic pedicle screw placement. Orthop Traumatol Surg Res 100:569–573
    • (2014) Orthop Traumatol Surg Res , vol.100 , pp. 569-573
    • Pesenti, S.1    Bartoli, M.A.2    Blondel, B.3
  • 33
    • 84930181078 scopus 로고    scopus 로고
    • An endovascular treatment of a thoracic aortic injury caused by a misplacement pedicle screw: Case report and review of the literature
    • PID: 24290859
    • Tong X, Gu P, Yu D et al. (2013) An endovascular treatment of a thoracic aortic injury caused by a misplacement pedicle screw: Case report and review of the literature. J Formos Med Assoc 114:464–468
    • (2013) J Formos Med Assoc , vol.114 , pp. 464-468
    • Tong, X.1    Gu, P.2    Yu, D.3
  • 34
    • 84941000858 scopus 로고    scopus 로고
    • Accuracy and safety of fluoroscopic guided percutaneous pedicle screws in thoracic and lumbosacral spine: a review of 2000 screws
    • Hansen-Algenstaedt N, Chiu CK, Chan CY, Lee CK, Schaefer C, Kwan MK (2015) Accuracy and safety of fluoroscopic guided percutaneous pedicle screws in thoracic and lumbosacral spine: a review of 2000 screws. Spine (Phila Pa 1976) 40:E954–E963
    • (2015) Spine (Phila Pa 1976) , vol.40 , pp. E954-E963
    • Hansen-Algenstaedt, N.1    Chiu, C.K.2    Chan, C.Y.3    Lee, C.K.4    Schaefer, C.5    Kwan, M.K.6
  • 35
    • 84947615601 scopus 로고    scopus 로고
    • Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric study. Eur Spine J
    • Lamartina C, Cecchinato R, Fekete Z et al. (2015) Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric study. Eur Spine J, Nov; 24 Suppl 7:937–941
    • (2015) Nov; 24 Suppl , vol.7 , pp. 937-941
    • Lamartina, C.1    Cecchinato, R.2    Fekete, Z.3
  • 36
    • 34247583545 scopus 로고    scopus 로고
    • Pullout resistance of thoracic extrapedicular screws used as a salvage procedure
    • PID: 17482111
    • Yüksel KZ, Adams MS, Chamberlain RH et al (2007) Pullout resistance of thoracic extrapedicular screws used as a salvage procedure. Spine J 7:286–291
    • (2007) Spine J , vol.7 , pp. 286-291
    • Yüksel, K.Z.1    Adams, M.S.2    Chamberlain, R.H.3
  • 37
    • 84900524014 scopus 로고    scopus 로고
    • Deviation analysis of atlantoaxial pedicle screws assisted by a drill template
    • PID: 24810817
    • Hu Y, Yuan ZS, Kepler CK et al (2014) Deviation analysis of atlantoaxial pedicle screws assisted by a drill template. Orthopedics 37:e420–e427
    • (2014) Orthopedics , vol.37 , pp. e420-e427
    • Hu, Y.1    Yuan, Z.S.2    Kepler, C.K.3
  • 38
    • 84930045508 scopus 로고    scopus 로고
    • Error rate of multi-level rapid prototyping trajectories for pedicle screw placement in lumbar and sacral spine
    • PID: 25293895
    • Merc M, Drstvensek I, Vogrin M et al (2014) Error rate of multi-level rapid prototyping trajectories for pedicle screw placement in lumbar and sacral spine. Chin J Traumatol 17:261–266
    • (2014) Chin J Traumatol , vol.17 , pp. 261-266
    • Merc, M.1    Drstvensek, I.2    Vogrin, M.3
  • 39
    • 84971261395 scopus 로고    scopus 로고
    • Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area
    • Eur Spine J, Epub ahead of print
    • Takemoto M, Fujibayashi S, Ota E, et al (2015) Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area. Eur Spine J. (Epub ahead of print)
    • (2015)
    • Takemoto, M.1    Fujibayashi, S.2    Ota, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.