메뉴 건너뛰기




Volumn 21, Issue 3, 2014, Pages 320-328

Safety and efficacy of pedicle screw placement using intraoperative computed tomography: Consecutive series of 1148 pedicle screws

Author keywords

Cervical; Fusion; Intraoperative CT; Lumbar; Pedicle screw; Safety; Spine surgery; Technique; Thoracic

Indexed keywords

ARTICLE; CERVICAL SPINE; CLINICAL EFFECTIVENESS; COHORT ANALYSIS; COMPUTER ASSISTED TOMOGRAPHY; DEEP VEIN THROMBOSIS; DEVICE SAFETY; FEMALE; HUMAN; INTRAOPERATIVE COMPUTER ASSISTED TOMOGRAPHY; INTRAOPERATIVE PERIOD; LENGTH OF STAY; LIQUORRHEA; LUMBAR SPINE; MAJOR CLINICAL STUDY; MALE; OPERATION DURATION; OUTCOME ASSESSMENT; PEDICLE SCREW; RADIATION EXPOSURE; REOPERATION; RETROSPECTIVE STUDY; SURGICAL INFECTION; THORACIC SPINE; BONE SCREW; CERVICAL; EQUIPMENT; FUSION; INTERVENTIONAL RADIOLOGY; INTRAOPERATIVE CT; LUMBAR; LUMBAR VERTEBRA; METHODOLOGY; MIDDLE AGED; PATIENT SAFETY; POSTOPERATIVE COMPLICATION; PROCEDURES; RADIOGRAPHY; SACRUM; SAFETY; SPINE DISEASE; SPINE FUSION; SPINE SURGERY; THORACIC; TREATMENT OUTCOME; VERTEBRA;

EID: 84908128710     PISSN: 15475654     EISSN: 15475646     Source Type: Journal    
DOI: 10.3171/2014.5.SPINE13567     Document Type: Article
Times cited : (45)

References (45)
  • 1
    • 0034061781 scopus 로고    scopus 로고
    • Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    • Amiot LP, Lang K, Putzier M, Zippel H, Labelle H: Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine (Phila Pa 1976) 25: 606-614, 2000
    • (2000) Spine (Phila Pa 1976) , vol.25 , pp. 606-614
    • Amiot, L.P.1    Lang, K.2    Putzier, M.3    Zippel, H.4    Labelle, H.5
  • 2
    • 0034747109 scopus 로고    scopus 로고
    • Precision analysis of navigation-assisted implanted thoracic and lumbar pedicled screws. A prospective clinical study
    • (Ger)
    • Arand M, Hartwig E, Hebold D, Kinzl L, Gebhard F: [Precision analysis of navigation-assisted implanted thoracic and lumbar pedicled screws. A prospective clinical study.] Unfallchirurg 104: 1076-1081, 2001 (Ger)
    • (2001) Unfallchirurg , vol.104 , pp. 1076-1081
    • Arand, M.1    Hartwig, E.2    Hebold, D.3    Kinzl, L.4    Gebhard, F.5
  • 3
    • 0035478265 scopus 로고    scopus 로고
    • Transpedicular screw placement: Image-guided versus lateralview fluoroscopy: In vitro simulation
    • Assaker R, Reyns N, Vinchon M, Demondion X, Louis E: Transpedicular screw placement: image-guided versus lateralview fluoroscopy: in vitro simulation. Spine (Phila Pa 1976) 26: 2160-2164, 2001
    • (2001) Spine (Phila Pa 1976) , vol.26 , pp. 2160-2164
    • Assaker, R.1    Reyns, N.2    Vinchon, M.3    Demondion, X.4    Louis, E.5
  • 4
    • 0037111853 scopus 로고    scopus 로고
    • Image-guided spine surgery: A cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models
    • Austin MS, Vaccaro AR, Brislin B, Nachwalter R, Hilibrand AS, Albert TJ: Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models. Spine (Phila Pa 1976) 27: 2503-2508, 2002
    • (2002) Spine (Phila Pa 1976) , vol.27 , pp. 2503-2508
    • Austin, M.S.1    Vaccaro, A.R.2    Brislin, B.3    Nachwalter, R.4    Hilibrand, A.S.5    Albert, T.J.6
  • 5
    • 0029163406 scopus 로고
    • A comparison of fluoroscopy and computed tomography-derived volumetric multiple exposure transmission holography for the guidance of lumbar pedicle screw insertion
    • Benzel EC, Rupp FW, McCormack BM, Baldwin NG, Anson JA, Adams MS: A comparison of fluoroscopy and computed tomography-derived volumetric multiple exposure transmission holography for the guidance of lumbar pedicle screw insertion. Neurosurgery 37: 711-716, 1995
    • (1995) Neurosurgery , vol.37 , pp. 711-716
    • Benzel, E.C.1    Rupp, F.W.2    McCormack, B.M.3    Baldwin, N.G.4    Anson, J.A.5    Adams, M.S.6
  • 6
    • 0034491195 scopus 로고    scopus 로고
    • Computer-assisted fluoroscopic targeting system for pedicle screw insertion
    • Choi WW, Green BA, Levi AD: Computer-assisted fluoroscopic targeting system for pedicle screw insertion. Neurosurgery 47: 872-878, 2000
    • (2000) Neurosurgery , vol.47 , pp. 872-878
    • Choi, W.W.1    Green, B.A.2    Levi, A.D.3
  • 7
    • 0037271763 scopus 로고    scopus 로고
    • Intraoperative computerized tomography for improved accuracy of spinal navigation in pedicle screw placement of the thoracic spine
    • Ebmeier K, Giest K, Kalff R: Intraoperative computerized tomography for improved accuracy of spinal navigation in pedicle screw placement of the thoracic spine. Acta Neurochir Suppl 85: 105-113, 2003
    • (2003) Acta Neurochir Suppl , vol.85 , pp. 105-113
    • Ebmeier, K.1    Giest, K.2    Kalff, R.3
  • 8
    • 0029044493 scopus 로고
    • Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography
    • Farber GL, Place HM, Mazur RA, Jones DE, Damiano TR: Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography. Spine (Phila Pa 1976) 20: 1494-1499, 1995
    • (1995) Spine (Phila Pa 1976) , vol.20 , pp. 1494-1499
    • Farber, G.L.1    Place, H.M.2    Mazur, R.A.3    Jones, D.E.4    Damiano, T.R.5
  • 9
    • 46149126169 scopus 로고    scopus 로고
    • Pedicle screw insertion: Computed tomography versus fluoroscopic image guidance
    • Fu TS, Wong CB, Tsai TT, Liang YC, Chen LH, Chen WJ: Pedicle screw insertion: computed tomography versus fluoroscopic image guidance. Int Orthop 32: 517-521, 2008
    • (2008) Int Orthop , vol.32 , pp. 517-521
    • Fu, T.S.1    Wong, C.B.2    Tsai, T.T.3    Liang, Y.C.4    Chen, L.H.5    Chen, W.J.6
  • 10
    • 33750088448 scopus 로고    scopus 로고
    • Image-guided spinal surgery
    • Holly LT: Image-guided spinal surgery. Int J Med Robot 2: 7-15, 2006
    • (2006) Int J Med Robot , vol.2 , pp. 7-15
    • Holly, L.T.1
  • 11
    • 33947153987 scopus 로고    scopus 로고
    • Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients
    • Ito H, Neo M, Yoshida M, Fujibayashi S, Yoshitomi H, Nakamura T: Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients. Rheumatol Int 27: 567-574, 2007
    • (2007) Rheumatol Int , vol.27 , pp. 567-574
    • Ito, H.1    Neo, M.2    Yoshida, M.3    Fujibayashi, S.4    Yoshitomi, H.5    Nakamura, T.6
  • 12
    • 0034466242 scopus 로고    scopus 로고
    • Cervical pedicle screw insertion: Assessment of safety and accuracy with computer-assisted image guidance
    • Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K: Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord 13: 218-224, 2000
    • (2000) J Spinal Disord , vol.13 , pp. 218-224
    • Kamimura, M.1    Ebara, S.2    Itoh, H.3    Tateiwa, Y.4    Kinoshita, T.5    Takaoka, K.6
  • 13
    • 25444518981 scopus 로고    scopus 로고
    • Evaluation of pedicle screw placement in the deformed spine using intraoperative plain radiographs: A comparison with computerized tomography
    • Kim YJ, Lenke LG, Cheh G, Riew KD: Evaluation of pedicle screw placement in the deformed spine using intraoperative plain radiographs: a comparison with computerized tomography. Spine (Phila Pa 1976) 30: 2084-2088, 2005
    • (2005) Spine (Phila Pa 1976) , vol.30 , pp. 2084-2088
    • Kim, Y.J.1    Lenke, L.G.2    Cheh, G.3    Riew, K.D.4
  • 14
    • 33846683025 scopus 로고    scopus 로고
    • Pedicle screw placement accuracy: A meta-analysis
    • Kosmopoulos V, Schizas C: Pedicle screw placement accuracy: a meta-analysis. Spine (Phila Pa 1976) 32: E111-E120, 2007
    • (2007) Spine (Phila Pa 1976) , vol.32 , pp. E111-E120
    • Kosmopoulos, V.1    Schizas, C.2
  • 15
    • 34250782220 scopus 로고    scopus 로고
    • Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: Comparison between conventional fluoroscopic and computer-assisted technique
    • Kotani Y, Abumi K, Ito M, Takahata M, Sudo H, Ohshima S, et al: Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique. Spine (Phila Pa 1976) 32: 1543-1550, 2007
    • (2007) Spine (Phila Pa 1976) , vol.32 , pp. 1543-1550
    • Kotani, Y.1    Abumi, K.2    Ito, M.3    Takahata, M.4    Sudo, H.5    Ohshima, S.6
  • 16
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomised controlled clinical study in 100 consecutive patients
    • Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D: Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9: 235-240, 2000
    • (2000) Eur Spine J , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikoski, M.3    Lohikoski, J.4    Schlenzka, D.5
  • 17
    • 0030926450 scopus 로고    scopus 로고
    • Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients
    • Laine T, Schlenzka D, Mäkitalo K, Tallroth K, Nolte LP, Visarius H: Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients. Spine (Phila Pa 1976) 22: 1254-1258, 1997
    • (1997) Spine (Phila Pa 1976) , vol.22 , pp. 1254-1258
    • Laine, T.1    Schlenzka, D.2    Mäkitalo, K.3    Tallroth, K.4    Nolte, L.P.5    Visarius, H.6
  • 18
    • 1842564006 scopus 로고    scopus 로고
    • Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: A proposed systematic approach to improve accuracy of interpretation
    • Learch TJ, Massie JB, Pathria MN, Ahlgren BA, Garfin SR: Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation. Spine (Phila Pa 1976) 29: 767-773, 2004
    • (2004) Spine (Phila Pa 1976) , vol.29 , pp. 767-773
    • Learch, T.J.1    Massie, J.B.2    Pathria, M.N.3    Ahlgren, B.A.4    Garfin, S.R.5
  • 19
    • 33846886691 scopus 로고    scopus 로고
    • Clinical accuracy of cervicothoracic pedicle screw placement: A comparison of the "open" lamino-foraminotomy and computer-assisted techniques
    • Lee GYF, Massicotte EM, Rampersaud YR: Clinical accuracy of cervicothoracic pedicle screw placement: a comparison of the "open" lamino-foraminotomy and computer-assisted techniques. J Spinal Disord Tech 20: 25-32, 2007
    • (2007) J Spinal Disord Tech , vol.20 , pp. 25-32
    • Gyf, L.1    Massicotte, E.M.2    Rampersaud, Y.R.3
  • 20
    • 3242700371 scopus 로고    scopus 로고
    • Single versus separate registration for computer-assisted lumbar pedicle screw placement
    • Lee TC, Yang LC, Liliang PC, Su TM, Rau CS, Chen HJ: Single versus separate registration for computer-assisted lumbar pedicle screw placement. Spine (Phila Pa 1976) 29: 1585- 1589, 2004
    • (2004) Spine (Phila Pa 1976) , vol.29 , pp. 1585-1589
    • Lee, T.C.1    Yang, L.C.2    Liliang, P.C.3    Su, T.M.4    Rau, C.S.5    Chen, H.J.6
  • 21
    • 35348900058 scopus 로고    scopus 로고
    • A comparison of two techniques in image-guided thoracic pedicle screw placement: A retrospective study of 37 patients and 277 pedicle screws
    • Lekovic GP, Potts EA, Karahalios DG, Hall G: A comparison of two techniques in image-guided thoracic pedicle screw placement: a retrospective study of 37 patients and 277 pedicle screws. J Neurosurg Spine 7: 393-398, 2007
    • (2007) J Neurosurg Spine , vol.7 , pp. 393-398
    • Lekovic, G.P.1    Potts, E.A.2    Karahalios, D.G.3    Hall, G.4
  • 22
    • 77954924261 scopus 로고    scopus 로고
    • Clinical applications of computer-assisted navigation technique in spinal pedicle screw internal fixation
    • (Chinese)
    • Li SG, Sheng L, Zhao H, Zhang JG, Zhai JL, Zhu Y: [Clinical applications of computer-assisted navigation technique in spinal pedicle screw internal fixation.] Zhonghua Yi Xue Za Zhi 89: 736-739, 2009 (Chinese)
    • (2009) Zhonghua Yi Xue Za Zhi , vol.89 , pp. 736-739
    • Li, S.G.1    Sheng, L.2    Zhao, H.3    Zhang, J.G.4    Zhai, J.L.5    Zhu, Y.6
  • 23
    • 39049192490 scopus 로고    scopus 로고
    • Accuracy of CT-based navigation of pedicle screws implantation in the cervical spine compared with X-ray fluoroscopy technique
    • (Chinese)
    • Liu YJ, Tian W, Liu B, Li Q, Hu L, Li ZY, et al: [Accuracy of CT-based navigation of pedicle screws implantation in the cervical spine compared with X-ray fluoroscopy technique.] Zhonghua Wai Ke Za Zhi 43: 1328-1330, 2005 (Chinese)
    • (2005) Zhonghua Wai Ke Za Zhi , vol.43 , pp. 1328-1330
    • Liu, Y.J.1    Tian, W.2    Liu, B.3    Li, Q.4    Hu, L.5    Li, Z.Y.6
  • 26
    • 0037442352 scopus 로고    scopus 로고
    • Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: A cadaver study
    • Mirza SK, Wiggins GC, Kuntz C IV, York JE, Bellabarba C, Knonodi MA, et al: Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study. Spine (Phila Pa 1976) 28: 402-413, 2003
    • (2003) Spine (Phila Pa 1976) , vol.28 , pp. 402-413
    • Mirza, S.K.1    Wiggins, G.C.2    Kuntz, C.I.V.3    York, J.E.4    Bellabarba, C.5    Knonodi, M.A.6
  • 27
    • 70349871137 scopus 로고    scopus 로고
    • Comparison of the percutaneous screw placement precision of isocentric C-arm 3-dimensional fluoroscopy-navigated pedicle screw implantation and conventional fluoroscopy method with minimally invasive surgery
    • Nakashima H, Sato K, Ando T, Inoh H, Nakamura H: Comparison of the percutaneous screw placement precision of isocentric C-arm 3-dimensional fluoroscopy-navigated pedicle screw implantation and conventional fluoroscopy method with minimally invasive surgery. J Spinal Disord Tech 22: 468-472, 2009
    • (2009) J Spinal Disord Tech , vol.22 , pp. 468-472
    • Nakashima, H.1    Sato, K.2    Ando, T.3    Inoh, H.4    Nakamura, H.5
  • 29
    • 61549092238 scopus 로고    scopus 로고
    • Placement of thoracolumbar pedicle screws using three-dimensional image guidance: Experience in a large patient cohort. Clinical article
    • Nottmeier EW, Seemer W, Young PM: Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort. Clinical article. J Neurosurg Spine 10: 33-39, 2009
    • (2009) J Neurosurg Spine , vol.10 , pp. 33-39
    • Nottmeier, E.W.1    Seemer, W.2    Young, P.M.3
  • 30
    • 78650923994 scopus 로고    scopus 로고
    • Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: Analysis of 6816 consecutive screws
    • Parker SL, McGirt MJ, Farber SH, Amin AG, Rick AM, Suk I, et al: Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws. Neurosurgery 68: 170-178, 2011
    • (2011) Neurosurgery , vol.68 , pp. 170-178
    • Parker, S.L.1    McGirt, M.J.2    Farber, S.H.3    Amin, A.G.4    Rick, A.M.5    Suk, I.6
  • 31
    • 33846239956 scopus 로고    scopus 로고
    • Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries
    • Rajasekaran S, Vidyadhara S, Ramesh P, Shetty AP: Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine (Phila Pa 1976) 32: E56-E64, 2007
    • (2007) Spine (Phila Pa 1976) , vol.32 , pp. E56-E64
    • Rajasekaran, S.1    Vidyadhara, S.2    Ramesh, P.3    Shetty, A.P.4
  • 32
    • 0035865653 scopus 로고    scopus 로고
    • Accuracy requirements for image-guided spinal pedicle screw placement
    • Rampersaud YR, Simon DA, Foley KT: Accuracy requirements for image-guided spinal pedicle screw placement. Spine (Phila Pa 1976) 26: 352-359, 2001
    • (2001) Spine (Phila Pa 1976) , vol.26 , pp. 352-359
    • Rampersaud, Y.R.1    Simon, D.A.2    Foley, K.T.3
  • 33
    • 0036726784 scopus 로고    scopus 로고
    • Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement
    • Rao G, Brodke DS, Rondina M, Dailey AT: Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement. J Neurosurg 97 (2 Suppl): 223-226, 2002
    • (2002) J Neurosurg , vol.97 , Issue.2 , pp. 223-226
    • Rao, G.1    Brodke, D.S.2    Rondina, M.3    Dailey, A.T.4
  • 34
    • 27144527301 scopus 로고    scopus 로고
    • Cervical pedicle screws: Conventional versus computer-assisted placement of cannulated screws
    • Richter M, Cakir B, Schmidt R: Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine (Phila Pa 1976) 30: 2280-2287, 2005
    • (2005) Spine (Phila Pa 1976) , vol.30 , pp. 2280-2287
    • Richter, M.1    Cakir, B.2    Schmidt, R.3
  • 36
    • 14844347683 scopus 로고    scopus 로고
    • Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle
    • Sakamoto T, Neo M, Nakamura T: Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle. Spine (Phila Pa 1976) 29: 2510-2515, 2004
    • (2004) Spine (Phila Pa 1976) , vol.29 , pp. 2510-2515
    • Sakamoto, T.1    Neo, M.2    Nakamura, T.3
  • 37
    • 1542288140 scopus 로고    scopus 로고
    • Accuracy of CT-based navitation of pedicle screws in the thoracic spine compared with conventional technique
    • (Ger)
    • Schnake KJ, König B, Berth U, Schroeder RJ, Kandziora F, Stöckle U, et al: [Accuracy of CT-based navitation of pedicle screws in the thoracic spine compared with conventional technique.] Unfallchirurg 107: 104-112, 2004 (Ger)
    • (2004) Unfallchirurg , vol.107 , pp. 104-112
    • Schnake, K.J.1    König, B.2    Berth, U.3    Schroeder, R.J.4    Kandziora, F.5    Stöckle, U.6
  • 39
    • 27744580272 scopus 로고    scopus 로고
    • Prospective screw misplacement analysis after conventional and navigated pedicle screw implantation
    • (Ger)
    • Seller K, Wild A, Urselmann L, Krauspe R: [Prospective screw misplacement analysis after conventional and navigated pedicle screw implantation.] Biomed Tech (Berl) 50: 287-292, 2005 (Ger)
    • (2005) Biomed Tech (Berl) , vol.50 , pp. 287-292
    • Seller, K.1    Wild, A.2    Urselmann, L.3    Krauspe, R.4
  • 40
    • 0033562611 scopus 로고    scopus 로고
    • Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery
    • Slomczykowski M, Roberto M, Schneeberger P, Ozdoba C, Vock P: Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery. Spine (Phila Pa 1976) 24: 975-983, 1999
    • (1999) Spine (Phila Pa 1976) , vol.24 , pp. 975-983
    • Slomczykowski, M.1    Roberto, M.2    Schneeberger, P.3    Ozdoba, C.4    Vock, P.5
  • 41
    • 80052564997 scopus 로고    scopus 로고
    • Pedicle screw insertion accuracy with different assisted methods: A systematic review and meta-analysis of comparative studies
    • Tian NF, Huang QS, Zhou P, Zhou Y, Wu RK, Lou Y, et al: Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies. Eur Spine J 20: 846-859, 2011
    • (2011) Eur Spine J , vol.20 , pp. 846-859
    • Tian, N.F.1    Huang, Q.S.2    Zhou, P.3    Zhou, Y.4    Wu, R.K.5    Lou, Y.6
  • 42
    • 68349104323 scopus 로고    scopus 로고
    • Image-guided pedicle screw insertion accuracy: A meta-analysis
    • Tian NF, Xu HZ: Image-guided pedicle screw insertion accuracy: a meta-analysis. Int Orthop 33: 895-903, 2009
    • (2009) Int Orthop , vol.33 , pp. 895-903
    • Tian, N.F.1    Xu, H.Z.2
  • 44
    • 77951143798 scopus 로고    scopus 로고
    • Functional outcome of computer-assisted spinal pedicle screw placement: A systematic review and meta-analysis of 23 studies including 5, 992 pedicle screws
    • Verma R, Krishan S, Haendlmayer K, Mohsen A: Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5, 992 pedicle screws. Eur Spine J 19: 370-375, 2010
    • (2010) Eur Spine J , vol.19 , pp. 370-375
    • Verma, R.1    Krishan, S.2    Haendlmayer, K.3    Mohsen, A.4
  • 45
    • 0033512262 scopus 로고    scopus 로고
    • Thoracic pedicle screw placement guided by computed tomographic measurements
    • Xu R, Ebraheim NA, Shepherd ME, Yeasting RA: Thoracic pedicle screw placement guided by computed tomographic measurements. J Spinal Disord 12: 222-226, 1999
    • (1999) J Spinal Disord , vol.12 , pp. 222-226
    • Xu, R.1    Ebraheim, N.A.2    Shepherd, M.E.3    Yeasting, R.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.