메뉴 건너뛰기




Volumn 53, Issue 5, 2016, Pages 313-325

Generation of data on within-subject biological variation in laboratory medicine: An update

Author keywords

analytical goals; between subject biological variation; index of individuality; inter individual biological variation; Intra individual biological variation; normality test; reference change value; within subject biological variation

Indexed keywords

ANALYTIC METHOD; CHECKLIST; HUMAN; LABORATORY; MEDICINE; PRACTICE GUIDELINE; PRIORITY JOURNAL; PUBLICATION; REFERENCE VALUE; REVIEW; SCIENTIST; SENSITIVITY ANALYSIS; BIOLOGICAL VARIATION; DIAGNOSTIC PROCEDURE; REPRODUCIBILITY; STANDARDS;

EID: 84961202240     PISSN: 10408363     EISSN: 1549781X     Source Type: Journal    
DOI: 10.3109/10408363.2016.1150252     Document Type: Review
Times cited : (83)

References (82)
  • 2
    • 0024342985 scopus 로고
    • Generation and application of data on biological variation in clinical chemistry
    • C.G.Fraser, E.K.Harris Generation and application of data on biological variation in clinical chemistry. Crit Rev Clin Lab Sci 1989;27:409–37
    • (1989) Crit Rev Clin Lab Sci , vol.27 , pp. 409-437
    • Fraser, C.G.1    Harris, E.K.2
  • 3
    • 84901597521 scopus 로고    scopus 로고
    • Verification of in vitro medical diagnostics (IVD) metrological traceability: responsibilities and strategies
    • F.Braga, M.Panteghini Verification of in vitro medical diagnostics (IVD) metrological traceability: responsibilities and strategies. Clin Chim Acta 2014;432:55–61
    • (2014) Clin Chim Acta , vol.432 , pp. 55-61
    • Braga, F.1    Panteghini, M.2
  • 4
    • 0033392528 scopus 로고    scopus 로고
    • Strategies to set global analytical quality specifications in laboratory medicine
    • C.G.Fraser, A.Kallner, D.Kenny,. Strategies to set global analytical quality specifications in laboratory medicine. Scand J Clin Lab Invest 1999;59:475–585
    • (1999) Scand J Clin Lab Invest , vol.59 , pp. 475-585
    • Fraser, C.G.1    Kallner, A.2    Kenny, D.3
  • 5
    • 84929091339 scopus 로고    scopus 로고
    • Defining analytical performance specifications 15 years after the Stockholm conference
    • M.Panteghini, S.Sandberg Defining analytical performance specifications 15 years after the Stockholm conference. Clin Chem Lab Med 2015;53:829–32
    • (2015) Clin Chem Lab Med , vol.53 , pp. 829-832
    • Panteghini, M.1    Sandberg, S.2
  • 6
    • 84929092769 scopus 로고    scopus 로고
    • Defining analytical performance specifications: Consensus Statement from the 1st Strategic Conference of the European Federation of Clinical Chemistry and Laboratory Medicine
    • S.Sandberg, C.Fraser, A.R.Horvath,. Defining analytical performance specifications: Consensus Statement from the 1st Strategic Conference of the European Federation of Clinical Chemistry and Laboratory Medicine. Clin Chem Lab Med 2015;53:833–5
    • (2015) Clin Chem Lab Med , vol.53 , pp. 833-835
    • Sandberg, S.1    Fraser, C.2    Horvath, A.R.3
  • 7
    • 77951752784 scopus 로고    scopus 로고
    • Establishment of outcome-related analytic performance goals
    • G.G.Klee Establishment of outcome-related analytic performance goals. Clin Chem 2010;56:714–22
    • (2010) Clin Chem , vol.56 , pp. 714-722
    • Klee, G.G.1
  • 8
    • 0031031761 scopus 로고    scopus 로고
    • Proposal for setting generally applicable quality goals solely based on biology
    • C.G.Fraser, P.Hyltoft Peterson, J.C.Libeer,. Proposal for setting generally applicable quality goals solely based on biology. Ann Clin Biochem 1997;34:8–12
    • (1997) Ann Clin Biochem , vol.34 , pp. 8-12
    • Fraser, C.G.1    Hyltoft Peterson, P.2    Libeer, J.C.3
  • 9
    • 80052247980 scopus 로고    scopus 로고
    • Gross overestimation of total allowable error based on biological variation
    • W.P.Oosterhuis Gross overestimation of total allowable error based on biological variation. Clin Chem 2011;57:1334–6
    • (2011) Clin Chem , vol.57 , pp. 1334-1336
    • Oosterhuis, W.P.1
  • 11
    • 0025086837 scopus 로고
    • Setting analytical goals for random analytical error in specific clinical monitoring situations
    • C.G.Fraser, P.Hyltoft Peterson, M.L.Larsen Setting analytical goals for random analytical error in specific clinical monitoring situations. Clin Chem 1990;36:1625–8
    • (1990) Clin Chem , vol.36 , pp. 1625-1628
    • Fraser, C.G.1    Hyltoft Peterson, P.2    Larsen, M.L.3
  • 13
    • 0019747737 scopus 로고
    • Statistical aspect of reference values in clinical pathology
    • E.K.Harris Statistical aspect of reference values in clinical pathology. Prog Clin Pathol 1981;8:45–66
    • (1981) Prog Clin Pathol , vol.8 , pp. 45-66
    • Harris, E.K.1
  • 14
    • 84855927552 scopus 로고    scopus 로고
    • Making better use of differences in serial laboratory results
    • C.G.Fraser Making better use of differences in serial laboratory results. Ann Clin Biochem 2012;49:1–3
    • (2012) Ann Clin Biochem , vol.49 , pp. 1-3
    • Fraser, C.G.1
  • 15
    • 84867764499 scopus 로고    scopus 로고
    • Reference change values
    • C.G.Fraser Reference change values. Clin Chem Lab Med 2012;50:807–12
    • (2012) Clin Chem Lab Med , vol.50 , pp. 807-812
    • Fraser, C.G.1
  • 16
    • 0020680638 scopus 로고
    • On the calculation of a “reference change” for comparing two consecutive measurements
    • E.K.Harris, T.Yasaka On the calculation of a “reference change” for comparing two consecutive measurements. Clin Chem 1983;29:25–30
    • (1983) Clin Chem , vol.29 , pp. 25-30
    • Harris, E.K.1    Yasaka, T.2
  • 18
    • 84874785871 scopus 로고    scopus 로고
    • Estimate of intraindividual variability of C-reactive protein: a challenging issue
    • F.Braga, S.Ferraro, D.Szöke,. Estimate of intraindividual variability of C-reactive protein: a challenging issue. Clin Chim Acta 2013;419:85–6
    • (2013) Clin Chim Acta , vol.419 , pp. 85-86
    • Braga, F.1    Ferraro, S.2    Szöke, D.3
  • 19
    • 84928019941 scopus 로고    scopus 로고
    • A new robust statistical model for interpretation of differences in serial test results from an individual
    • F.Braga, S.Ferraro, F.Ieva,. A new robust statistical model for interpretation of differences in serial test results from an individual. Clin Chem Lab Med 2015;53:815–22
    • (2015) Clin Chem Lab Med , vol.53 , pp. 815-822
    • Braga, F.1    Ferraro, S.2    Ieva, F.3
  • 20
    • 58149239885 scopus 로고    scopus 로고
    • Current issues in measurement and reporting of urinary albumin excretion
    • W.G.Miller, D.E.Bruns, G.L.Hortin,. Current issues in measurement and reporting of urinary albumin excretion. Clin Chem 2009;55:24–38
    • (2009) Clin Chem , vol.55 , pp. 24-38
    • Miller, W.G.1    Bruns, D.E.2    Hortin, G.L.3
  • 21
    • 77956455682 scopus 로고    scopus 로고
    • Biological variation of glycated hemoglobin
    • F.Braga, A.Dolci, A.Mosca,. Biological variation of glycated hemoglobin. Clin Chim Acta 2010;411:1006–10
    • (2010) Clin Chim Acta , vol.411 , pp. 1006-1010
    • Braga, F.1    Dolci, A.2    Mosca, A.3
  • 22
    • 84861337481 scopus 로고    scopus 로고
    • Biologic variability of C-reactive protein: is the available information reliable?
    • F.Braga, M.Panteghini Biologic variability of C-reactive protein: is the available information reliable? Clin Chim Acta 2012;413:1179–83
    • (2012) Clin Chim Acta , vol.413 , pp. 1179-1183
    • Braga, F.1    Panteghini, M.2
  • 23
    • 84888105658 scopus 로고    scopus 로고
    • A systematic review of data on biological variation for alanine aminotransferase, aspartate aminotransferase and γ-glutamyl transferase
    • A.Carobene, F.Braga, T.Roraas,. A systematic review of data on biological variation for alanine aminotransferase, aspartate aminotransferase and γ-glutamyl transferase. Clin Chem Lab Med 2013;51:1997–2007
    • (2013) Clin Chem Lab Med , vol.51 , pp. 1997-2007
    • Carobene, A.1    Braga, F.2    Roraas, T.3
  • 24
    • 84929080089 scopus 로고    scopus 로고
    • A checklist for critical appraisal of studies of biological variation
    • W.A.Bartlett, F.Braga, A.Carobene,. A checklist for critical appraisal of studies of biological variation. Clin Chem Lab Med 2015;53:879–85
    • (2015) Clin Chem Lab Med , vol.53 , pp. 879-885
    • Bartlett, W.A.1    Braga, F.2    Carobene, A.3
  • 26
    • 34548025386 scopus 로고    scopus 로고
    • Within-subject biological variation in disease: collated data and clinical consequences
    • C.1.Ricós, N.Iglesias, J.V.García-Lario,. Within-subject biological variation in disease: collated data and clinical consequences. Ann Clin Biochem 2007;44:343–52
    • (2007) Ann Clin Biochem , vol.44 , pp. 343-352
    • Ricós, C.1    Iglesias, N.2    García-Lario, J.V.3
  • 27
    • 34548036768 scopus 로고    scopus 로고
    • Is variation in biological variation a problem?
    • N.Lawson Is variation in biological variation a problem? Ann Clin Biochem 2007;44:319–20
    • (2007) Ann Clin Biochem , vol.44 , pp. 319-320
    • Lawson, N.1
  • 28
    • 82755167827 scopus 로고    scopus 로고
    • Improved monitoring of differences in serial laboratory results
    • C.G.Fraser Improved monitoring of differences in serial laboratory results. Clin Chem 2011;57:1635–7
    • (2011) Clin Chem , vol.57 , pp. 1635-1637
    • Fraser, C.G.1
  • 29
    • 0024385363 scopus 로고
    • Biological variability of 26 clinical chemistry analytes in elderly people
    • C.Fraser, S.T.Cummings, S.P.Wilkinson,. Biological variability of 26 clinical chemistry analytes in elderly people. Clin Chem 1989;35:783–6
    • (1989) Clin Chem , vol.35 , pp. 783-786
    • Fraser, C.1    Cummings, S.T.2    Wilkinson, S.P.3
  • 30
    • 84867832240 scopus 로고    scopus 로고
    • Age dependence of within-subject biological variation of nine common clinical chemistry analytes
    • A.Carobene, M.S.Graziani, C.Lo Cascio,. Age dependence of within-subject biological variation of nine common clinical chemistry analytes. Clin Chem Lab Med 2012;50:841–4
    • (2012) Clin Chem Lab Med , vol.50 , pp. 841-844
    • Carobene, A.1    Graziani, M.S.2    Lo Cascio, C.3
  • 31
    • 84907179658 scopus 로고    scopus 로고
    • The importance of individual biology in the clinical use of serum biomarkers for ovarian cancer
    • F.Braga, S.Ferraro, R.Mozzi,. The importance of individual biology in the clinical use of serum biomarkers for ovarian cancer. Clin Chem Lab Med 2014;52:1625–31
    • (2014) Clin Chem Lab Med , vol.52 , pp. 1625-1631
    • Braga, F.1    Ferraro, S.2    Mozzi, R.3
  • 32
    • 0023334280 scopus 로고
    • Longer-term biological variation of commonly analyzed serum constituents
    • E.M.Gowans, C.G.Fraser Longer-term biological variation of commonly analyzed serum constituents. Clin Chem 1987;33:717
    • (1987) Clin Chem , vol.33 , pp. 717
    • Gowans, E.M.1    Fraser, C.G.2
  • 33
    • 84883444778 scopus 로고    scopus 로고
    • Proposta di una “checklist” per il prelievo di sangue venoso
    • G.Lippi, C.Mattiuzzi, G.Banfi Proposta di una “checklist” per il prelievo di sangue venoso. Biochim Clin 2013;37:312–17
    • (2013) Biochim Clin , vol.37 , pp. 312-317
    • Lippi, G.1    Mattiuzzi, C.2    Banfi, G.3
  • 34
    • 84883374677 scopus 로고    scopus 로고
    • Giavarina D per il Gruppo di Studio Intersocietario SIBioC-SIMeL-CISMEL sulla Variabilità Extra-Analitica del Dato di Laboratorio. Raccomandazioni per il prelievo di sangue venoso
    • G.Lippi, M.Caputo, G.Banfi,. Giavarina D per il Gruppo di Studio Intersocietario SIBioC-SIMeL-CISMEL sulla Variabilità Extra-Analitica del Dato di Laboratorio. Raccomandazioni per il prelievo di sangue venoso. Biochim Clin 2008;32:569–77
    • (2008) Biochim Clin , vol.32 , pp. 569-577
    • Lippi, G.1    Caputo, M.2    Banfi, G.3
  • 35
    • 0037406354 scopus 로고    scopus 로고
    • On the comparison of serum and plasma samples in troponin assays
    • M.Panteghini, F.Pagani On the comparison of serum and plasma samples in troponin assays. Clin Chem 2003;49:835–6
    • (2003) Clin Chem , vol.49 , pp. 835-836
    • Panteghini, M.1    Pagani, F.2
  • 37
    • 84871813127 scopus 로고    scopus 로고
    • Biological variation of neuroendocrine tumor markers chromogranin A and neuron-specific enolase
    • F.Braga, S.Ferraro, R.Mozzi,. Biological variation of neuroendocrine tumor markers chromogranin A and neuron-specific enolase. Clin Biochem 2013;46:148–51
    • (2013) Clin Biochem , vol.46 , pp. 148-151
    • Braga, F.1    Ferraro, S.2    Mozzi, R.3
  • 38
    • 0028821766 scopus 로고
    • Biological variation in bone-derived biochemical markers in serum
    • M.Panteghini, F.Pagani Biological variation in bone-derived biochemical markers in serum. Scand J Clin Lab Invest 1995;55:609–16
    • (1995) Scand J Clin Lab Invest , vol.55 , pp. 609-616
    • Panteghini, M.1    Pagani, F.2
  • 39
    • 0027497090 scopus 로고
    • Significance of various parameters derived from biological variability for lipid and lipoprotein analyses
    • F.Pagani, M.Panteghini Significance of various parameters derived from biological variability for lipid and lipoprotein analyses. Clin Biochem 1993;26:415–20
    • (1993) Clin Biochem , vol.26 , pp. 415-420
    • Pagani, F.1    Panteghini, M.2
  • 40
    • 0034039258 scopus 로고    scopus 로고
    • Seasonal and biological variation of blood concentrations of total cholesterol, dehydroepiandrosterone sulfate, hemoglobin A1c, IgA, prolactin, and free testosterone in healthy women
    • A.H.Garde, A.M.Hansen, L.T.Skovgaard,. Seasonal and biological variation of blood concentrations of total cholesterol, dehydroepiandrosterone sulfate, hemoglobin A1c, IgA, prolactin, and free testosterone in healthy women. Clin Chem 2000;46:551–9
    • (2000) Clin Chem , vol.46 , pp. 551-559
    • Garde, A.H.1    Hansen, A.M.2    Skovgaard, L.T.3
  • 41
    • 44349178752 scopus 로고    scopus 로고
    • Traceability, reference systems and result comparability
    • M.Panteghini Traceability, reference systems and result comparability. Clin Biochem Rev 2007;28:97–104
    • (2007) Clin Biochem Rev , vol.28 , pp. 97-104
    • Panteghini, M.1
  • 42
    • 84888115451 scopus 로고    scopus 로고
    • Standardization and analytical goals for glycated hemoglobin measurement
    • F.Braga, M.Panteghini Standardization and analytical goals for glycated hemoglobin measurement. Clin Chem Lab Med 2013;51:1719–26
    • (2013) Clin Chem Lab Med , vol.51 , pp. 1719-1726
    • Braga, F.1    Panteghini, M.2
  • 43
    • 79956314334 scopus 로고    scopus 로고
    • Revaluation of biological variation of glycated hemoglobin (HbA1c) using an accurately designed protocol and an assay traceable to the IFCC reference system
    • F.Braga, A.Dolci, M.Montagnana,. Revaluation of biological variation of glycated hemoglobin (HbA1c) using an accurately designed protocol and an assay traceable to the IFCC reference system. Clin Chim Acta 2011;412:1412–16
    • (2011) Clin Chim Acta , vol.412 , pp. 1412-1416
    • Braga, F.1    Dolci, A.2    Montagnana, M.3
  • 44
    • 84887241852 scopus 로고    scopus 로고
    • Evaluation of the impact of standardization process on the quality of serum creatinine determination in Italian laboratories
    • A.Carobene, F.Ceriotti, I.Infusino,. Evaluation of the impact of standardization process on the quality of serum creatinine determination in Italian laboratories. Clin Clin Acta 2014;427:100–6
    • (2014) Clin Clin Acta , vol.427 , pp. 100-106
    • Carobene, A.1    Ceriotti, F.2    Infusino, I.3
  • 45
    • 44949254207 scopus 로고    scopus 로고
    • Enzymatic assays for creatinine: time for action
    • M.Panteghini Enzymatic assays for creatinine: time for action. Clin Chem Lab Med 2008;46:567–72
    • (2008) Clin Chem Lab Med , vol.46 , pp. 567-572
    • Panteghini, M.1
  • 46
    • 84880658467 scopus 로고    scopus 로고
    • Quality requirements for troponin assays – An overview
    • Alexandria, NSW, Australia: The Australasian Association of Clinical Biochemists Inc
    • M.Panteghini Quality requirements for troponin assays – An overview. In: Troponin Monograph 2012. Alexandria, NSW, Australia: The Australasian Association of Clinical Biochemists Inc., 2012:53–61
    • (2012) Troponin Monograph 2012 , pp. 53-61
    • Panteghini, M.1
  • 47
    • 84975200847 scopus 로고    scopus 로고
    • Procalcitonin in healthy individuals. Electronic letter to Barassi A, Pallotti F, d Eril GM. Biological variation of procalcitonin in healthy individuals
    • V.C.Vasile, A.K.Saenger, J.M.Kroning,. Procalcitonin in healthy individuals. Electronic letter to Barassi A, Pallotti F, d Eril GM. Biological variation of procalcitonin in healthy individuals. Clin Chem 2004;50:1086. Available at: http://www.zoominfo.com/CachedPage/?archive_id=0&page_id=857341327&page_url=//www.clinchem.org/cgi/eletters/50/10/1878&page_last_updated=2004-10-11T03:42:47&firstName=Nils&lastName=Morgenthaler
    • (2004) Clin Chem , vol.50 , pp. 1086
    • Vasile, V.C.1    Saenger, A.K.2    Kroning, J.M.3
  • 48
    • 79959723393 scopus 로고    scopus 로고
    • Biological variation and reference change value of high-sensitivity troponin T in healthy individuals during short and intermediate follow-up periods
    • L.Frankenstein, A.H.Wu, K.Hallermayer,. Biological variation and reference change value of high-sensitivity troponin T in healthy individuals during short and intermediate follow-up periods. Clin Chem 2011;57:1068–71
    • (2011) Clin Chem , vol.57 , pp. 1068-1071
    • Frankenstein, L.1    Wu, A.H.2    Hallermayer, K.3
  • 49
    • 84975190425 scopus 로고    scopus 로고
    • Procalcitonin in healthy individuals. Electronic letter to Barassi A, Pallotti F, d'Eril GM. Biological variation of procalcitonin in healthy individuals
    • G.M.Nils, J.Struck, A.Bergmann Procalcitonin in healthy individuals. Electronic letter to Barassi A, Pallotti F, d'Eril GM. Biological variation of procalcitonin in healthy individuals. Clin Chem 2004;50:1878.Available at: http://www.zoominfo.com/CachedPage/?archive_id=0&page_id=857341327&page_url=//www.clinchem.org/cgi/eletters/50/10/1878&page_last_updated=2004-10-11T03:42:47&firstName=Nils&lastName=Morgenthaler
    • (2004) Clin Chem , vol.50
    • Nils, G.M.1    Struck, J.2    Bergmann, A.3
  • 50
    • 0015056904 scopus 로고
    • Biological and analytic components of variation in long-term studies of serum constituents in normal subjects. IV. Results of a study designed to eliminate long-term analytic deviations
    • D.S.Young, E.K.Harris, E.Cotlove Biological and analytic components of variation in long-term studies of serum constituents in normal subjects. IV. Results of a study designed to eliminate long-term analytic deviations. Clin Chem 1971;17:403–10
    • (1971) Clin Chem , vol.17 , pp. 403-410
    • Young, D.S.1    Harris, E.K.2    Cotlove, E.3
  • 51
    • 84929070241 scopus 로고    scopus 로고
    • Performance criteria for combined uncertainty budget in the implementation of metrological traceability
    • F.Braga, I.Infusino, M.Panteghini Performance criteria for combined uncertainty budget in the implementation of metrological traceability. Clin Chem Lab Med 2015;53:905–12
    • (2015) Clin Chem Lab Med , vol.53 , pp. 905-912
    • Braga, F.1    Infusino, I.2    Panteghini, M.3
  • 52
    • 0000898845 scopus 로고
    • An analysis of variance test for normality (complete samples)
    • S.S.Shapiro, M.B.Wilk An analysis of variance test for normality (complete samples). Biometrika 1965;52:591–611
    • (1965) Biometrika , vol.52 , pp. 591-611
    • Shapiro, S.S.1    Wilk, M.B.2
  • 53
    • 84975171739 scopus 로고
    • Kolmogorov–Smirnov one-sample test
    • Daniel W.W., (ed), 2nd ed., Boston (MA): Cengage
    • W.W.Daniel Kolmogorov–Smirnov one-sample test. In: W.W.Daniel, ed. Applied Nonparametric Statistics. 2nd ed. Boston (MA): Cengage, 1990:319–30
    • (1990) Applied Nonparametric Statistics , pp. 319-330
    • Daniel, W.W.1
  • 54
    • 77956815759 scopus 로고    scopus 로고
    • Wilcoxon–Mann–Whitney or t-test? On assumptions for hypothesis tests and multiple interpretations of decision rules
    • M.P.Fay, M.A.Proschan Wilcoxon–Mann–Whitney or t-test? On assumptions for hypothesis tests and multiple interpretations of decision rules. Stat Surv 2010;4:1–39. doi: 10.1214/09-SS051
    • (2010) Stat Surv , vol.4 , pp. 1-39
    • Fay, M.P.1    Proschan, M.A.2
  • 56
    • 0002044602 scopus 로고
    • The distribution of the largest of a set of estimated variances as a fraction of their total
    • W.G.Cochran The distribution of the largest of a set of estimated variances as a fraction of their total. Ann Hum Genet 1941;11:47–52
    • (1941) Ann Hum Genet , vol.11 , pp. 47-52
    • Cochran, W.G.1
  • 58
  • 59
    • 0019636384 scopus 로고
    • A comparative study of tests for homogeneity of variances, with applications to the outer continental shelf bidding data
    • W.J.Conover, M.E.Johnson, M.M.Johnson A comparative study of tests for homogeneity of variances, with applications to the outer continental shelf bidding data. Technometrics 1981;23:351–61
    • (1981) Technometrics , vol.23 , pp. 351-361
    • Conover, W.J.1    Johnson, M.E.2    Johnson, M.M.3
  • 60
    • 84865714284 scopus 로고    scopus 로고
    • Confidence intervals and power calculations for within-subject biological variation: effect of analytical variation, number of replicates, number of samples and number of individuals
    • T.Roraas, P.H.Petersen, S.Sandberg Confidence intervals and power calculations for within-subject biological variation: effect of analytical variation, number of replicates, number of samples and number of individuals. Clin Chem 2012;58:1306–13
    • (2012) Clin Chem , vol.58 , pp. 1306-1313
    • Roraas, T.1    Petersen, P.H.2    Sandberg, S.3
  • 61
    • 84921866537 scopus 로고    scopus 로고
    • Terms and symbols used on studies of biological variation: the need for harmonisation
    • A.M.Simundic, S.Kackov, M.Miler,. Terms and symbols used on studies of biological variation: the need for harmonisation. Clin Chem 2015;61:438–9
    • (2015) Clin Chem , vol.61 , pp. 438-439
    • Simundic, A.M.1    Kackov, S.2    Miler, M.3
  • 62
    • 84920897028 scopus 로고    scopus 로고
    • Biological variation database: structure and criteria used for generation and update
    • C.Perich, J.Minchinela, C.Ricós,. Biological variation database: structure and criteria used for generation and update. Clin Chem Lab Med 2015;53:299–305
    • (2015) Clin Chem Lab Med , vol.53 , pp. 299-305
    • Perich, C.1    Minchinela, J.2    Ricós, C.3
  • 63
    • 84944031123 scopus 로고    scopus 로고
    • How to assess the quality of your analytical method?
    • E.Topic, N.Nikolac, M.Panteghini,. How to assess the quality of your analytical method? Clin Chem Lab Med 2015;53:1707–18
    • (2015) Clin Chem Lab Med , vol.53 , pp. 1707-1718
    • Topic, E.1    Nikolac, N.2    Panteghini, M.3
  • 64
    • 84865378821 scopus 로고    scopus 로고
    • Intraindividual variability of C- reactive protein: the multi-ethnic study of atherosclerosis
    • E.M.DeGoma, B.French, R.L.Dunbar,. Intraindividual variability of C- reactive protein: the multi-ethnic study of atherosclerosis. Atherosclerosis 2012;224:274–9
    • (2012) Atherosclerosis , vol.224 , pp. 274-279
    • DeGoma, E.M.1    French, B.2    Dunbar, R.L.3
  • 65
    • 59649104144 scopus 로고    scopus 로고
    • Tracking of high-sensitivity C-reactive protein after an initially elevated concentration: the JUPITER Study
    • R.D.J.Glynn, J.G.MacFadyen, P.M.Ridker Tracking of high-sensitivity C-reactive protein after an initially elevated concentration: the JUPITER Study. Clin Chem 2009;55:305–12
    • (2009) Clin Chem , vol.55 , pp. 305-312
    • Glynn, R.D.J.1    MacFadyen, J.G.2    Ridker, P.M.3
  • 66
    • 0036191680 scopus 로고    scopus 로고
    • Limited clinical utility of high-sensitivity plasma C-reactive protein assays
    • B.Campbell, T.Badrick, R.Flatman,. Limited clinical utility of high-sensitivity plasma C-reactive protein assays. Ann Clin Biochem 2002;39:85–8
    • (2002) Ann Clin Biochem , vol.39 , pp. 85-88
    • Campbell, B.1    Badrick, T.2    Flatman, R.3
  • 67
    • 84875224028 scopus 로고    scopus 로고
    • Serum human epididymis protein 4 vs carbohydrate antigen 125 for ovarian cancer diagnosis: a systematic review
    • S.Ferraro, F.Braga, M.Lanzoni,. Serum human epididymis protein 4 vs carbohydrate antigen 125 for ovarian cancer diagnosis: a systematic review. J Clin Pathol 2013;66:273–81
    • (2013) J Clin Pathol , vol.66 , pp. 273-281
    • Ferraro, S.1    Braga, F.2    Lanzoni, M.3
  • 69
    • 78049518359 scopus 로고    scopus 로고
    • Ovarian tumor marker HE4 is differently expressed during the phase of menstrual cycle in healthy young women
    • E.Anastasi, T.Granato, G.G.Marchei,. Ovarian tumor marker HE4 is differently expressed during the phase of menstrual cycle in healthy young women. Tumor Biol 2010;31:411–15
    • (2010) Tumor Biol , vol.31 , pp. 411-415
    • Anastasi, E.1    Granato, T.2    Marchei, G.G.3
  • 70
    • 84928746194 scopus 로고    scopus 로고
    • Body mass index does not influence human hepididymis protein 4 concentrations in serum
    • S.Ferraro, S.Borille, S.Caruso,. Body mass index does not influence human hepididymis protein 4 concentrations in serum. Clin Chim Acta 2015;446:163–4
    • (2015) Clin Chim Acta , vol.446 , pp. 163-164
    • Ferraro, S.1    Borille, S.2    Caruso, S.3
  • 71
    • 79959545138 scopus 로고    scopus 로고
    • C-reactive protein in the primary prevention of myocardial infarction and stroke
    • Ridker P.M., Rifai N., (eds), St-Laurent (QC): MediEdition
    • P.M.Ridker, N.Rifai. C-reactive protein in the primary prevention of myocardial infarction and stroke. In: P.M.Ridker, N.Rifai eds. C-reactive protein and cardiovascular disease. St-Laurent (QC): MediEdition, 2006:1–23
    • (2006) C-reactive protein and cardiovascular disease , pp. 1-23
    • Ridker, P.M.1    Rifai, N.2
  • 72
    • 59649120505 scopus 로고    scopus 로고
    • Seasonal and sex variation of high-sensitivity C reactive protein in healthy adults: a longitudinal study
    • D.E.Chiriboga, Y.Ma, W.Li,. Seasonal and sex variation of high-sensitivity C reactive protein in healthy adults: a longitudinal study. Clin Chem 2009;55:313–21
    • (2009) Clin Chem , vol.55 , pp. 313-321
    • Chiriboga, D.E.1    Ma, Y.2    Li, W.3
  • 73
    • 75149130955 scopus 로고    scopus 로고
    • Diagnosis and classification of diabetes mellitus
    • American Diabetes Association. Diagnosis and classification of diabetes mellitus. Diabetes Care 2010;33:S62–9
    • (2010) Diabetes Care , vol.33 , pp. S62-S69
  • 74
    • 0030159203 scopus 로고    scopus 로고
    • Development of a reference system for the international standardization of HbA1c/glycohemoglobin determinations
    • W.Hoelzel, K.Miedema Development of a reference system for the international standardization of HbA1c/glycohemoglobin determinations. J Int Fed Clin Chem 1996;9:62–7
    • (1996) J Int Fed Clin Chem , vol.9 , pp. 62-67
    • Hoelzel, W.1    Miedema, K.2
  • 75
    • 39749107290 scopus 로고    scopus 로고
    • The IFCC reference measurement system for HbA1c: a 6-year progress report
    • C.Weykamp, W.G.John, A.Mosca,. The IFCC reference measurement system for HbA1c: a 6-year progress report. Clin Chem 2008;54:240–8
    • (2008) Clin Chem , vol.54 , pp. 240-248
    • Weykamp, C.1    John, W.G.2    Mosca, A.3
  • 76
    • 79551488806 scopus 로고    scopus 로고
    • Status of hemoglobin A1c measurement and goals for improvement: from chaos to order for improving diabetes care
    • R.R.Little, C.L.Rohlfing, D.B.Sacks Status of hemoglobin A1c measurement and goals for improvement: from chaos to order for improving diabetes care. Clin Chem 2011;57:205–14
    • (2011) Clin Chem , vol.57 , pp. 205-214
    • Little, R.R.1    Rohlfing, C.L.2    Sacks, D.B.3
  • 77
    • 34548719355 scopus 로고    scopus 로고
    • Implementation of haemoglobin A1c results traceable to the IFCC reference system: the way forward
    • M.Panteghini, W.G.John Implementation of haemoglobin A1c results traceable to the IFCC reference system: the way forward. Clin Chem Lab Med 2007;45:942–4
    • (2007) Clin Chem Lab Med , vol.45 , pp. 942-944
    • Panteghini, M.1    John, W.G.2
  • 78
    • 9144234059 scopus 로고    scopus 로고
    • Wiedmeyer HM on behalf of the IFCC Working Group on HbA1c Standardization IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study
    • W.Hoelzel, C.Weykamp, J.Jeppsson,. Wiedmeyer HM on behalf of the IFCC Working Group on HbA1c Standardization IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study. Clin Chem 2004;50:166–74
    • (2004) Clin Chem , vol.50 , pp. 166-174
    • Hoelzel, W.1    Weykamp, C.2    Jeppsson, J.3
  • 79
    • 79961044207 scopus 로고    scopus 로고
    • The analytical goals for hemoglobin A1c measurement in IFCC units and National Glycohemoglobin Standardization Program units are different
    • C.W.Weykamp, A.Mosca, P.Gillery,. The analytical goals for hemoglobin A1c measurement in IFCC units and National Glycohemoglobin Standardization Program units are different. Clin Chem 2011;57:1204–6
    • (2011) Clin Chem , vol.57 , pp. 1204-1206
    • Weykamp, C.W.1    Mosca, A.2    Gillery, P.3
  • 80
    • 84866650846 scopus 로고    scopus 로고
    • Biological variation of free light chains in serum
    • F.Braga, I.Infusino, A.Dolci,. Biological variation of free light chains in serum. Clin Chim Acta 2013;415:10–11
    • (2013) Clin Chim Acta , vol.415 , pp. 10-11
    • Braga, F.1    Infusino, I.2    Dolci, A.3
  • 81
    • 72249097973 scopus 로고    scopus 로고
    • Scrutiny of variance results for outliers: Cochran’s test optimized
    • R.U.’t Lam Scrutiny of variance results for outliers: Cochran’s test optimized. Anal Chim Acta 2010;659:68–84
    • (2010) Anal Chim Acta , vol.659 , pp. 68-84
    • ’t Lam, R.U.1
  • 82
    • 84870484683 scopus 로고    scopus 로고
    • Biologic variation of copper, ceruloplasmin and copper/ceruloplasmin ratio (Cu:Cp) in serum
    • F.Braga, D.Szőke, C.Valente,. Biologic variation of copper, ceruloplasmin and copper/ceruloplasmin ratio (Cu:Cp) in serum. Clin Chim Acta 2013;415:295–6
    • (2013) Clin Chim Acta , vol.415 , pp. 295-296
    • Braga, F.1    Szőke, D.2    Valente, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.