메뉴 건너뛰기




Volumn 50, Issue 5, 2012, Pages 807-812

Reference change values

Author keywords

Biological variation; Imprecision; Probability; Reference change values

Indexed keywords

ACCURACY; CALCULATION; CHRONIC DISEASE; CLINICAL LABORATORY; HUMAN; LABORATORY INFORMATION MANAGEMENT SYSTEM; MEDICAL EDUCATION; MEDICAL INFORMATION SYSTEM; PRACTICE GUIDELINE; PRIORITY JOURNAL; PROBABILITY; REFERENCE CHANGE VALUE; REFERENCE VALUE; REVIEW; SEMANTICS; STANDARDIZATION;

EID: 84867764499     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/CCLM.2011.733     Document Type: Review
Times cited : (217)

References (31)
  • 2
    • 4344570957 scopus 로고    scopus 로고
    • Inherent biological variation and reference values
    • Fraser CG. Inherent biological variation and reference values. Clin Chem Lab Med 2004;42:758-64.
    • (2004) Clin Chem Lab Med , vol.42 , pp. 758-764
    • Fraser, C.G.1
  • 3
    • 66249133346 scopus 로고    scopus 로고
    • Reference change values: The way forward in monitoring
    • Fraser CG. Reference change values: the way forward in monitoring. Ann Clin Biochem 2009;46:264-5.
    • (2009) Ann Clin Biochem , vol.46 , pp. 264-265
    • Fraser, C.G.1
  • 4
    • 0020680638 scopus 로고
    • On the calculation of a "reference change" for comparing two consecutive measurements
    • Harris EK, Yasaka T. On the calculation of a "reference change" for comparing two consecutive measurements. Clin Chem 1983;29:25-30.
    • (1983) Clin Chem , vol.29 , pp. 25-30
    • Harris, E.K.1    Yasaka, T.2
  • 7
    • 3242702506 scopus 로고    scopus 로고
    • Test result variation and the quality of evidence-based clinical guidelines
    • Fraser CG. Test result variation and the quality of evidence-based clinical guidelines. Clin Chim Acta 2004;346:19-24.
    • (2004) Clin Chim Acta , vol.346 , pp. 19-24
    • Fraser, C.G.1
  • 8
    • 0031031761 scopus 로고    scopus 로고
    • Proposal for setting generally applicable quality goals solely based on biology
    • Fraser CG, Hyltoft Petersen P, Libeer JC, Ricós C. Proposal for setting generally applicable quality goals solely based on biology. Ann Clin Biochem 1997;34:8-12.
    • (1997) Ann Clin Biochem , vol.34 , pp. 8-12
    • Fraser, C.G.1    Hyltoft Petersen, P.2    Libeer, J.C.3    Ricós, C.4
  • 9
    • 79954465764 scopus 로고    scopus 로고
    • Collective opinion paper on findings of the 2010 convocation of experts on laboratory quality
    • Cooper G, De Jonge N, Ehrmeyer S, Yundt-Pacheco J, Jansen R, Ricos C, et al. Collective opinion paper on findings of the 2010 convocation of experts on laboratory quality. Clin Chem Lab Med 2011;49:793-802.
    • (2011) Clin Chem Lab Med , vol.49 , pp. 793-802
    • Cooper, G.1    De Jonge, N.2    Ehrmeyer, S.3    Yundt-Pacheco, J.4    Jansen, R.5    Ricos, C.6
  • 11
    • 33644869566 scopus 로고    scopus 로고
    • Guidelines on the diagnosis and management of multiple myeloma 2005
    • Smith A, Wisloff F, Samson D. Guidelines on the diagnosis and management of multiple myeloma 2005. Br J Haematol 2006;132:410-51.
    • (2006) Br J Haematol , vol.132 , pp. 410-451
    • Smith, A.1    Wisloff, F.2    Samson, D.3
  • 12
    • 36649017237 scopus 로고    scopus 로고
    • National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines: Use of cardiac troponin and B-type natri-uretic peptide or n-terminal proB-type natriuretic peptide for etiologies other than acute coronary syndromes and heart failure
    • National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines: use of cardiac troponin and B-type natri-uretic peptide or n-terminal proB-type natriuretic peptide for etiologies other than acute coronary syndromes and heart failure. Clin Chem 2007;53:2086-96.
    • (2007) Clin Chem , vol.53 , pp. 2086-2096
  • 13
    • 77953007710 scopus 로고    scopus 로고
    • Being rational about (im) precision: A statement from the Biochemistry Subcommittee of the Joint European Society of Cardiology/American College of Cardiology Foundation/American Heart Association/World Heart Federation Task Force for the Definition of Myocardial Infarction
    • Jaffe AS, Apple FS, Morrow DA, Lindahl B, Katus HA. Being rational about (im) precision: a statement from the Biochemistry Subcommittee of the Joint European Society of Cardiology/American College of Cardiology Foundation/American Heart Association/World Heart Federation Task Force for the Definition of Myocardial Infarction. Clin Chem 2010;56:941-3.
    • (2010) Clin Chem , vol.56 , pp. 941-943
    • Jaffe, A.S.1    Apple, F.S.2    Morrow, D.A.3    Lindahl, B.4    Katus, H.A.5
  • 14
    • 65949119138 scopus 로고    scopus 로고
    • Role of monitoring changes in sensitive cardiac tro-ponin I assay results for early diagnosis of myocardial infarction and prediction of risk of adverse events
    • Apple FS, Pearce LA, Smith SW, Kaczmarek JM, Murakami MM. Role of monitoring changes in sensitive cardiac tro-ponin I assay results for early diagnosis of myocardial infarction and prediction of risk of adverse events. Clin Chem 2009;55:930-7.
    • (2009) Clin Chem , vol.55 , pp. 930-937
    • Apple, F.S.1    Pearce, L.A.2    Smith, S.W.3    Kaczmarek, J.M.4    Murakami, M.M.5
  • 15
    • 84884413263 scopus 로고    scopus 로고
    • The long-term biologic variation of serum protein electrophoresis M-spike, urine M-spike, and monoclonal serum free light chain quantitation: Implications for monitoring monoclonal gammopathies
    • in press
    • Katzmann JA, Snyder MR, Rajkumar SV, Kyle RA, Therneau TM, Benson JT, et al. The long-term biologic variation of serum protein electrophoresis M-spike, urine M-spike, and monoclonal serum free light chain quantitation: implications for monitoring monoclonal gammopathies. Clin Chem, in press.
    • Clin Chem
    • Katzmann, J.A.1    Snyder, M.R.2    Rajkumar, S.V.3    Kyle, R.A.4    Therneau, T.M.5    Benson, J.T.6
  • 17
    • 75149122477 scopus 로고    scopus 로고
    • Biological variation of glycated haemoglobin in a paediatric population and its application to calculation of significant change between results
    • Desmeules P, Cousineau J, Allard P. Biological variation of glycated haemoglobin in a paediatric population and its application to calculation of significant change between results. Ann Clin Biochem 2010;47:35-8.
    • (2010) Ann Clin Biochem , vol.47 , pp. 35-38
    • Desmeules, P.1    Cousineau, J.2    Allard, P.3
  • 19
    • 84884412277 scopus 로고    scopus 로고
    • Improved monitoring of differences in serial laboratory results
    • in press
    • Fraser CG. Improved monitoring of differences in serial laboratory results. Clin Chem, in press.
    • Clin Chem
    • Fraser, C.G.1
  • 20
    • 34548036768 scopus 로고    scopus 로고
    • Is variation in biological variation a problem ?
    • Lawson N. Is variation in biological variation a problem ? Ann Clin Biochem 2007;44:319-29.
    • (2007) Ann Clin Biochem , vol.44 , pp. 319-329
    • Lawson, N.1
  • 23
    • 4344605064 scopus 로고
    • Biological variation in the elderly; implications for reference values
    • Faulkner WR, Meites S, editors, Washington, DC: AACC Press
    • Fraser CG. Biological variation in the elderly; implications for reference values. In: Faulkner WR, Meites S, editors. Geriatric Clinical Chemistry Reference Values, Washington, DC: AACC Press, 1994:44.
    • (1994) Geriatric Clinical Chemistry Reference Values , pp. 44
    • Fraser, C.G.1
  • 24
    • 77958181146 scopus 로고    scopus 로고
    • The use of serial patient blood gas, electrolyte and glucose results to derive biologic variation: A new tool to assess the acceptability of intensive care unit testing
    • Cembrowski GS, Trani D V, Higgins TN, The use of serial patient blood gas, electrolyte and glucose results to derive biologic variation: a new tool to assess the acceptability of intensive care unit testing. Clin Chem Lab Med 2010;48:1447-54.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 1447-1454
    • Cembrowski, G.S.1    Trani, D.V.2    Higgins, T.N.3
  • 25
    • 0024342985 scopus 로고
    • Generation and application of data on biological variation in clinical chemistry
    • Fraser CG, Harris EK. Generation and application of data on biological variation in clinical chemistry. Crit Rev Clin Lab Sci 1989;27:409-37.
    • (1989) Crit Rev Clin Lab Sci , vol.27 , pp. 409-437
    • Fraser, C.G.1    Harris, E.K.2
  • 26
    • 0036827338 scopus 로고    scopus 로고
    • Biological variation data are necessary prerequisites for objective autoverification of clinical laboratory data
    • Fraser CG, Stevenson HP, Kennedy IMG. Biological variation data are necessary prerequisites for objective autoverification of clinical laboratory data. Accred Qual Assur 2002;7:455-60.
    • (2002) Accred Qual Assur , vol.7 , pp. 455-460
    • Fraser, C.G.1    Stevenson, H.P.2    Kennedy, I.M.G.3
  • 28
    • 33746605983 scopus 로고    scopus 로고
    • Reference change values for brain natriuretic peptides revisited
    • Fokkema MR, Herrmann Z, Muskiet FAJ, Moecks J. Reference change values for brain natriuretic peptides revisited. Clin Chem 2006;52:1602-3.
    • (2006) Clin Chem , vol.52 , pp. 1602-1603
    • Fokkema, M.R.1    Herrmann, Z.2    Muskiet, F.A.J.3    Moecks, J.4
  • 29
    • 79959723393 scopus 로고    scopus 로고
    • Biological variation and reference change value of high-sensitivity troponin T in healthy individuals during short and intermediate follow-up periods
    • Frankenstein L, Wu AH, Hallermayer K, Wians FH, Giannitsi E, Katus HA. Biological variation and reference change value of high-sensitivity troponin T in healthy individuals during short and intermediate follow-up periods. Clin Chem 2011;57:1068-71.
    • (2011) Clin Chem , vol.57 , pp. 1068-1071
    • Frankenstein, L.1    Wu, A.H.2    Hallermayer, K.3    Wians, F.H.4    Giannitsi, E.5    Katus, H.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.