메뉴 건너뛰기




Volumn 57, Issue 12, 2011, Pages 1635-1637

Improved monitoring of differences in serial laboratory results

Author keywords

[No Author keywords available]

Indexed keywords

MONOCLONAL ANTIBODY; MONOCLONAL PROTEIN; PROTEIN; TROPONIN; UNCLASSIFIED DRUG;

EID: 82755167827     PISSN: 00099147     EISSN: 15308561     Source Type: Journal    
DOI: 10.1373/clinchem.2011.175026     Document Type: Editorial
Times cited : (25)

References (14)
  • 1
    • 4344570957 scopus 로고    scopus 로고
    • Inherent biological variation and reference values
    • DOI 10.1515/CCLM.2004.128
    • Fraser CG. Inherent biological variation and reference values. Clin Chem Lab Med 2004;42:758-64. (Pubitemid 39137225)
    • (2004) Clinical Chemistry and Laboratory Medicine , vol.42 , Issue.7 , pp. 758-764
    • Fraser, C.G.1
  • 2
    • 66249133346 scopus 로고    scopus 로고
    • Reference change values: The way forward in monitoring
    • Fraser CG. Reference change values: the way forward in monitoring. Ann Clin Biochem 2009;46:264-5.
    • (2009) Ann Clin Biochem , vol.46 , pp. 264-265
    • Fraser, C.G.1
  • 3
    • 82755190444 scopus 로고    scopus 로고
    • Long-term biologic variation of serum protein electrophoresis M-spike, urine M-spike, and monoclonal serum free light chain quantification: Implications for monitoring monoclonal gammopathies
    • Katzmann JA, Snyder MR, Rajkumar SV, Kyle RA, Therneau TM, Benson JT, Dispenzieri A. Long-term biologic variation of serum protein electrophoresis M-spike, urine M-spike, and monoclonal serum free light chain quantification: implications for monitoring monoclonal gammopathies. Clin Chem 2011;57:1687-92.
    • (2011) Clin Chem , vol.57 , pp. 1687-1692
    • Katzmann, J.A.1    Snyder, M.R.2    Rajkumar, S.V.3    Kyle, R.A.4    Therneau, T.M.5    Benson, J.T.6    Dispenzieri, A.7
  • 5
    • 33644869566 scopus 로고    scopus 로고
    • Guidelines on the diagnosis and management of multiple myeloma 2005
    • on behalf of the UK Myeloma Forum, Nordic Myeloma Study Group and British Committee for Standards in Haematology
    • Smith A, Wisloff F, Samson D, on behalf of the UK Myeloma Forum, Nordic Myeloma Study Group and British Committee for Standards in Haematology. Guidelines on the diagnosis and management of multiple myeloma 2005. Br J Haematol 2006;132:410-51.
    • (2006) Br J Haematol , vol.132 , pp. 410-451
    • Smith, A.1    Wisloff, F.2    Samson, D.3
  • 8
    • 74549158121 scopus 로고    scopus 로고
    • Biological variation database, and quality specifications for imprecision, bias and total error (desirable and minimum)
    • Westgard QC. Accessed September 2011
    • Ricós C, García-Lario J-V, Alvares V, Cava F, Domenech M, Hernández A, et al. Biological variation database, and quality specifications for imprecision, bias and total error (desirable and minimum). The 2010 update. Westgard QC. http://www.westgard.com/biodatabase-2010-update. htm (Accessed September 2011).
    • The 2010 Update
    • Ricós, C.1    García-Lario, J.-V.2    Alvares, V.3    Cava, F.4    Domenech, M.5    Hernández, A.6
  • 9
    • 34548025386 scopus 로고    scopus 로고
    • Within-subject biological variation in disease: Collated data and clinical consequences
    • See Accessed September 2011
    • Ricós C, Iglesias N, García-Lario J-V, Simón M, Cava F, Hernández A, et al. Within-subject biological variation in disease: collated data and clinical consequences. Ann Clin Biochem 2007:44:343-52. See http://www.westgard.com/biological-variation-in-patients-with-disease.htm (Accessed September 2011).
    • (2007) Ann Clin Biochem , vol.44 , pp. 343-352
    • Ricós, C.1    Iglesias, N.2    García-Lario, J.-V.3    Simón, M.4    Cava, F.5    Hernández, A.6
  • 11
    • 75149122477 scopus 로고    scopus 로고
    • Biological variation of glycated haemoglobin in a paediatric population and its application to calculation of significant change between results
    • Desmeules P, Cousineau J, Allard P. Biological variation of glycated haemoglobin in a paediatric population and its application to calculation of significant change between results. Ann Clin Biochem 2010;47:35-8.
    • (2010) Ann Clin Biochem , vol.47 , pp. 35-38
    • Desmeules, P.1    Cousineau, J.2    Allard, P.3
  • 12
    • 77958181146 scopus 로고    scopus 로고
    • The use of serial patient blood gas, electrolyte and glucose results to derive biologic variation: A new tool to assess the acceptability of intensive care unit testing
    • Cembrowski GS, Tran DV, Higgins TN. The use of serial patient blood gas, electrolyte and glucose results to derive biologic variation: a new tool to assess the acceptability of intensive care unit testing. Clin Chem Lab Med 2010;48:1447-54.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 1447-1454
    • Cembrowski, G.S.1    Tran, D.V.2    Higgins, T.N.3
  • 13
    • 0024342985 scopus 로고
    • Generation and application of data on biological variation in clinical chemistry
    • Fraser CG, Harris EK. Generation and application of data on biological variation in clinical chemistry. Crit Rev Clin Lab Sci 1989;27:409-37.
    • (1989) Crit Rev Clin Lab Sci , vol.27 , pp. 409-437
    • Fraser, C.G.1    Harris, E.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.