메뉴 건너뛰기




Volumn 25, Issue 3, 2016, Pages 870-876

Morphometric measurement of the lumbosacral spine for minimally invasive cortical bone trajectory implant using computed tomography

Author keywords

Cortical bone trajectory; Facet; Lumbosacral spine; Pedicle

Indexed keywords

ADULT; AGED; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CORTICAL BONE TRAJECTORY; DEMOGRAPHY; FEMALE; HUMAN; LUMBOSACRAL SPINE; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; MIDDLE AGED; MORPHOMETRICS; PEDICLE SCREW; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING; VERTEBRA BODY; VERY ELDERLY; YOUNG ADULT; ANATOMIC LANDMARK; DIAGNOSTIC IMAGING; LUMBAR VERTEBRA; MINIMALLY INVASIVE SURGERY; PROCEDURES; SACRUM; SPINE FUSION; SURGERY; X-RAY COMPUTED TOMOGRAPHY; ZYGAPOPHYSEAL JOINT;

EID: 84958762293     PISSN: 09406719     EISSN: 14320932     Source Type: Journal    
DOI: 10.1007/s00586-015-4224-3     Document Type: Article
Times cited : (15)

References (23)
  • 1
    • 0031427801 scopus 로고    scopus 로고
    • Internal fixation in the osteoporotic spine
    • COI: 1:STN:280:DyaK1c%2FptlOisA%3D%3D
    • Hu SS (1997) Internal fixation in the osteoporotic spine. Spine (Phila Pa 1976) 22(24 Suppl):43S–48S
    • (1997) Spine (Phila Pa 1976) , vol.22 , pp. 43S-48S
    • Hu, S.S.1
  • 2
    • 0027365874 scopus 로고
    • Stability of transpedicle screwing for the osteoporotic spine. An in vitro study of the mechanical stability
    • COI: 1:STN:280:DyaK2c7gsFOqtQ%3D%3D
    • Okuyama K, Sato K, Abe E, Inaba H, Shimada Y, Murai H (1993) Stability of transpedicle screwing for the osteoporotic spine. An in vitro study of the mechanical stability. Spine (Phila Pa 1976) 18(15):2240–2245
    • (1993) Spine (Phila Pa 1976) , vol.18 , Issue.15 , pp. 2240-2245
    • Okuyama, K.1    Sato, K.2    Abe, E.3    Inaba, H.4    Shimada, Y.5    Murai, H.6
  • 4
    • 84919482444 scopus 로고    scopus 로고
    • Krag versus caudad trajectory technique for pedicle screw insertion in osteoporotic vertebrae: biomechanical comparison and analysis
    • Yuan Q, Han X, Han X, He D, Liu B, Tian W (2014) Krag versus caudad trajectory technique for pedicle screw insertion in osteoporotic vertebrae: biomechanical comparison and analysis. Spine (Phila Pa 1976) 39(26B):B27–B35
    • (2014) Spine (Phila Pa 1976) , vol.39 , Issue.26B , pp. B27-B35
    • Yuan, Q.1    Han, X.2    Han, X.3    He, D.4    Liu, B.5    Tian, W.6
  • 5
    • 84958829520 scopus 로고    scopus 로고
    • Brodkef DS: Fenestrated screws augmented with PMMA increase the pull-out strength of sacral pedicle screws. J Spinal Disord Tech [Epub ahead of print]
    • Colmana M, Pondb J, Bachusc K, Lawrenced BD, Spikere WR, Brodkef DS (2014) Fenestrated screws augmented with PMMA increase the pull-out strength of sacral pedicle screws. J Spinal Disord Tech [Epub ahead of print]
    • (2014) Spikere WR
    • Colmana, M.1    Pondb, J.2    Bachusc, K.3    Lawrenced, B.D.4
  • 6
    • 84974604293 scopus 로고    scopus 로고
    • Should we use cortical bone screws for cortical bone trajectory?
    • PID: 25594731
    • Ueno M, Sakai R, Tanaka K, Inoue G, Uchida K, Imura T et al (2015) Should we use cortical bone screws for cortical bone trajectory? J Neurosurg Spine 22(4):416–421
    • (2015) J Neurosurg Spine , vol.22 , Issue.4 , pp. 416-421
    • Ueno, M.1    Sakai, R.2    Tanaka, K.3    Inoue, G.4    Uchida, K.5    Imura, T.6
  • 8
  • 9
    • 84896723365 scopus 로고    scopus 로고
    • In vivo analysis of insertional torque during pedicle screwing using cortical bone trajectory technique
    • Matsukawa K, Yato Y, Kato T, Imabayashi H, Asazuma T, Nemoto K (2014) In vivo analysis of insertional torque during pedicle screwing using cortical bone trajectory technique. Spine (Phila Pa 1976) 39(4):E240–E245
    • (2014) Spine (Phila Pa 1976) , vol.39 , Issue.4 , pp. E240-E245
    • Matsukawa, K.1    Yato, Y.2    Kato, T.3    Imabayashi, H.4    Asazuma, T.5    Nemoto, K.6
  • 11
    • 67749110199 scopus 로고    scopus 로고
    • An anatomical study of the mid-lateral pars relative to the pedicle footprint in the lower lumbar spine
    • Su BW, Kim PD, Cha TD, Lee J, April EW, Weidenbaum M, Vaccaro AR (2009) An anatomical study of the mid-lateral pars relative to the pedicle footprint in the lower lumbar spine. Spine (Phila Pa 1976) 34(13):1355–1362
    • (2009) Spine (Phila Pa 1976) , vol.34 , Issue.13 , pp. 1355-1362
    • Su, B.W.1    Kim, P.D.2    Cha, T.D.3    Lee, J.4    April, E.W.5    Weidenbaum, M.6    Vaccaro, A.R.7
  • 12
    • 14844353716 scopus 로고    scopus 로고
    • Accurate determination of isthmus of lumbar pedicle: a morphometric study using reformatted computed tomographic images
    • Li B, Jiang B, Fu Z, Zhang D, Wang T (2004) Accurate determination of isthmus of lumbar pedicle: a morphometric study using reformatted computed tomographic images. Spine (Phila Pa 1976) 29(21):2438–2444
    • (2004) Spine (Phila Pa 1976) , vol.29 , Issue.21 , pp. 2438-2444
    • Li, B.1    Jiang, B.2    Fu, Z.3    Zhang, D.4    Wang, T.5
  • 13
    • 37649008179 scopus 로고    scopus 로고
    • Does the shape of the L5 vertebral body depend on the height of CT slices in the pedicle? Evaluation of the shape of the L5 vertebral body with a multicut CT scan
    • Alfonso M, Palacio P, Bastarrika G, Villas C (2008) Does the shape of the L5 vertebral body depend on the height of CT slices in the pedicle? Evaluation of the shape of the L5 vertebral body with a multicut CT scan. Spine (Phila Pa 1976) 33(1):E1–E5
    • (2008) Spine (Phila Pa 1976) , vol.33 , Issue.1 , pp. E1-E5
    • Alfonso, M.1    Palacio, P.2    Bastarrika, G.3    Villas, C.4
  • 14
    • 84881477180 scopus 로고    scopus 로고
    • Morphometric measurement of cortical bone trajectory for lumbar pedicle screw insertion using computed tomography
    • PID: 23429319
    • Matsukawa K, Yato Y, Nemoto O, Imabayashi H, Asazuma T, Nemoto K (2013) Morphometric measurement of cortical bone trajectory for lumbar pedicle screw insertion using computed tomography. J Spinal Disord Tech 26(6):E248–E253
    • (2013) J Spinal Disord Tech , vol.26 , Issue.6 , pp. E248-E253
    • Matsukawa, K.1    Yato, Y.2    Nemoto, O.3    Imabayashi, H.4    Asazuma, T.5    Nemoto, K.6
  • 15
    • 0033503395 scopus 로고    scopus 로고
    • Pedicle screw placement at the sacrum: anatomical characterization and limitations at S1
    • COI: 1:STN:280:DyaK1MzhtVWnuw%3D%3D, PID: 10382776
    • Robertson PA, Plank LD (1999) Pedicle screw placement at the sacrum: anatomical characterization and limitations at S1. J Spinal Disord 12(3):227–233
    • (1999) J Spinal Disord , vol.12 , Issue.3 , pp. 227-233
    • Robertson, P.A.1    Plank, L.D.2
  • 16
    • 0025890130 scopus 로고
    • Surgical anatomy of the sacrum: a guide for rational screw fixation
    • COI: 1:STN:280:DyaK3MzitVansA%3D%3D
    • Esses SI, Botsford DJ, Huler RJ, Rauschning W (1991) Surgical anatomy of the sacrum: a guide for rational screw fixation. Spine (Phila Pa 1976) 16(6 Suppl):S283–S288
    • (1991) Spine (Phila Pa 1976) , vol.16 , pp. S283-S288
    • Esses, S.I.1    Botsford, D.J.2    Huler, R.J.3    Rauschning, W.4
  • 17
    • 0032076151 scopus 로고    scopus 로고
    • The internal bony architecture of the sacrum
    • COI: 1:STN:280:DyaK1c3ltFCgug%3D%3D
    • Peretz AM, Hipp JA, Heggeness MH (1998) The internal bony architecture of the sacrum. Spine (Phila Pa 1976) 23(9):971–974
    • (1998) Spine (Phila Pa 1976) , vol.23 , Issue.9 , pp. 971-974
    • Peretz, A.M.1    Hipp, J.A.2    Heggeness, M.H.3
  • 18
    • 0033951314 scopus 로고    scopus 로고
    • Variation in bone mineral density of the sacrum in young adults and its significance for sacral fixation
    • COI: 1:STN:280:DC%2BD3c7mslOmtg%3D%3D
    • Zheng Y, Lu WW, Zhu Q, Qin L, Zhong S, Leong JC (2000) Variation in bone mineral density of the sacrum in young adults and its significance for sacral fixation. Spine (Phila Pa 1976) 25(3):353–357
    • (2000) Spine (Phila Pa 1976) , vol.25 , Issue.3 , pp. 353-357
    • Zheng, Y.1    Lu, W.W.2    Zhu, Q.3    Qin, L.4    Zhong, S.5    Leong, J.C.6
  • 19
    • 0033954922 scopus 로고    scopus 로고
    • Internal architecture of the sacrum in the elderly. An anatomic and radiographic study
    • COI: 1:STN:280:DC%2BD3c7mslOntg%3D%3D
    • Ebraheim N, Sabry FF, Nadim Y, Xu R, Yeasting RA (2000) Internal architecture of the sacrum in the elderly. An anatomic and radiographic study. Spine (Phila Pa 1976) 25(3):292–297
    • (2000) Spine (Phila Pa 1976) , vol.25 , Issue.3 , pp. 292-297
    • Ebraheim, N.1    Sabry, F.F.2    Nadim, Y.3    Xu, R.4    Yeasting, R.A.5
  • 20
    • 84905495112 scopus 로고    scopus 로고
    • Cortical bone trajectory for lumbosacral fixation: penetrating S-1 endplate screw technique: technical note
    • PID: 24766288
    • Matsukawa K, Yato Y, Kato T, Imabayashi H, Asazuma T, Nemoto K (2014) Cortical bone trajectory for lumbosacral fixation: penetrating S-1 endplate screw technique: technical note. J Neurosurg Spine 21(2):203–209
    • (2014) J Neurosurg Spine , vol.21 , Issue.2 , pp. 203-209
    • Matsukawa, K.1    Yato, Y.2    Kato, T.3    Imabayashi, H.4    Asazuma, T.5    Nemoto, K.6
  • 21
    • 84881012172 scopus 로고    scopus 로고
    • The “medio-latero-superior trajectory technique”: an alternative cortical trajectory for pedicle fixation
    • Mobbs RJ (2013) The “medio-latero-superior trajectory technique”: an alternative cortical trajectory for pedicle fixation. Orthopaed Surg 5(1):56–59
    • (2013) Orthopaed Surg , vol.5 , Issue.1 , pp. 56-59
    • Mobbs, R.J.1
  • 22
    • 84907562798 scopus 로고    scopus 로고
    • Hybrid technique of cortical bone trajectory and pedicle screwing for minimally invasive spine reconstruction surgery: a technical note
    • Takata Y, Matsuura T, Higashino K, Sakai T, Mishiro T, Suzue N et al (2014) Hybrid technique of cortical bone trajectory and pedicle screwing for minimally invasive spine reconstruction surgery: a technical note. J Med Investig JMI 61(3–4):388–392
    • (2014) J Med Investig JMI , vol.61 , Issue.3-4 , pp. 388-392
    • Takata, Y.1    Matsuura, T.2    Higashino, K.3    Sakai, T.4    Mishiro, T.5    Suzue, N.6
  • 23
    • 84897667745 scopus 로고    scopus 로고
    • Novel placement of cortical bone trajectory screws in previously instrumented pedicles for adjacent-segment lumbar disease using CT image-guided navigation
    • PID: 24580010
    • Rodriguez A, Neal MT, Liu A, Somasundaram A, Hsu W, Branch CL Jr (2014) Novel placement of cortical bone trajectory screws in previously instrumented pedicles for adjacent-segment lumbar disease using CT image-guided navigation. Neurosurg Focus 36(3):E9
    • (2014) Neurosurg Focus , vol.36 , Issue.3 , pp. E9
    • Rodriguez, A.1    Neal, M.T.2    Liu, A.3    Somasundaram, A.4    Hsu, W.5    Branch, C.L.6