-
1
-
-
0031427801
-
Internal fixation in the osteoporotic spine
-
COI: 1:STN:280:DyaK1c%2FptlOisA%3D%3D
-
Hu SS (1997) Internal fixation in the osteoporotic spine. Spine (Phila Pa 1976) 22(24 Suppl):43S–48S
-
(1997)
Spine (Phila Pa 1976)
, vol.22
, pp. 43S-48S
-
-
Hu, S.S.1
-
2
-
-
0027365874
-
Stability of transpedicle screwing for the osteoporotic spine. An in vitro study of the mechanical stability
-
COI: 1:STN:280:DyaK2c7gsFOqtQ%3D%3D
-
Okuyama K, Sato K, Abe E, Inaba H, Shimada Y, Murai H (1993) Stability of transpedicle screwing for the osteoporotic spine. An in vitro study of the mechanical stability. Spine (Phila Pa 1976) 18(15):2240–2245
-
(1993)
Spine (Phila Pa 1976)
, vol.18
, Issue.15
, pp. 2240-2245
-
-
Okuyama, K.1
Sato, K.2
Abe, E.3
Inaba, H.4
Shimada, Y.5
Murai, H.6
-
3
-
-
85042409560
-
Comparison of pedicle screw fixation strength among different transpedicular trajectories: a finite element study
-
Matsukawa K, Yato Y, Hynes RA, Imabayashi H, Hosogane N, Yoshihara Y et al (2015) Comparison of pedicle screw fixation strength among different transpedicular trajectories: a finite element study. J Spinal Disord Tech [Epub ahead of print]
-
(2015)
J Spinal Disord Tech [Epub ahead of print]
-
-
Matsukawa, K.1
Yato, Y.2
Hynes, R.A.3
Imabayashi, H.4
Hosogane, N.5
Yoshihara, Y.6
-
4
-
-
84919482444
-
Krag versus caudad trajectory technique for pedicle screw insertion in osteoporotic vertebrae: biomechanical comparison and analysis
-
Yuan Q, Han X, Han X, He D, Liu B, Tian W (2014) Krag versus caudad trajectory technique for pedicle screw insertion in osteoporotic vertebrae: biomechanical comparison and analysis. Spine (Phila Pa 1976) 39(26B):B27–B35
-
(2014)
Spine (Phila Pa 1976)
, vol.39
, Issue.26B
, pp. B27-B35
-
-
Yuan, Q.1
Han, X.2
Han, X.3
He, D.4
Liu, B.5
Tian, W.6
-
5
-
-
84958829520
-
-
Brodkef DS: Fenestrated screws augmented with PMMA increase the pull-out strength of sacral pedicle screws. J Spinal Disord Tech [Epub ahead of print]
-
Colmana M, Pondb J, Bachusc K, Lawrenced BD, Spikere WR, Brodkef DS (2014) Fenestrated screws augmented with PMMA increase the pull-out strength of sacral pedicle screws. J Spinal Disord Tech [Epub ahead of print]
-
(2014)
Spikere WR
-
-
Colmana, M.1
Pondb, J.2
Bachusc, K.3
Lawrenced, B.D.4
-
6
-
-
84974604293
-
Should we use cortical bone screws for cortical bone trajectory?
-
PID: 25594731
-
Ueno M, Sakai R, Tanaka K, Inoue G, Uchida K, Imura T et al (2015) Should we use cortical bone screws for cortical bone trajectory? J Neurosurg Spine 22(4):416–421
-
(2015)
J Neurosurg Spine
, vol.22
, Issue.4
, pp. 416-421
-
-
Ueno, M.1
Sakai, R.2
Tanaka, K.3
Inoue, G.4
Uchida, K.5
Imura, T.6
-
7
-
-
64849089881
-
Cortical bone trajectory for lumbar pedicle screws
-
COI: 1:STN:280:DC%2BD1M3pvFShsQ%3D%3D, PID: 18790684
-
Santoni BG, Hynes RA, McGilvray KC, Rodriguez-Canessa G, Lyons AS, Henson MA et al (2009) Cortical bone trajectory for lumbar pedicle screws. Spine J 9(5):366–373
-
(2009)
Spine J
, vol.9
, Issue.5
, pp. 366-373
-
-
Santoni, B.G.1
Hynes, R.A.2
McGilvray, K.C.3
Rodriguez-Canessa, G.4
Lyons, A.S.5
Henson, M.A.6
-
8
-
-
79955603027
-
Pedicle screw insertion angle and pullout strength: comparison of 2 proposed strategies
-
Inceoglu S, Montgomery WH Jr, St Clair S, McLain RF (2011) Pedicle screw insertion angle and pullout strength: comparison of 2 proposed strategies. J Neurosurg Spine (Phila Pa 1976) 14(5):670–676
-
(2011)
J Neurosurg Spine (Phila Pa 1976)
, vol.14
, Issue.5
, pp. 670-676
-
-
Inceoglu, S.1
Montgomery, W.H.2
St Clair, S.3
McLain, R.F.4
-
9
-
-
84896723365
-
In vivo analysis of insertional torque during pedicle screwing using cortical bone trajectory technique
-
Matsukawa K, Yato Y, Kato T, Imabayashi H, Asazuma T, Nemoto K (2014) In vivo analysis of insertional torque during pedicle screwing using cortical bone trajectory technique. Spine (Phila Pa 1976) 39(4):E240–E245
-
(2014)
Spine (Phila Pa 1976)
, vol.39
, Issue.4
, pp. E240-E245
-
-
Matsukawa, K.1
Yato, Y.2
Kato, T.3
Imabayashi, H.4
Asazuma, T.5
Nemoto, K.6
-
10
-
-
72849115041
-
In vivo three-dimensional morphometric analysis of the lumbar pedicle isthmus
-
Sugisaki K, An HS, Espinoza Orías AA, Rhim R, Andersson GB, Inoue N (2009) In vivo three-dimensional morphometric analysis of the lumbar pedicle isthmus. Spine (Phila Pa 1976) 34(24):2599–2604
-
(2009)
Spine (Phila Pa 1976)
, vol.34
, Issue.24
, pp. 2599-2604
-
-
Sugisaki, K.1
An, H.S.2
Espinoza Orías, A.A.3
Rhim, R.4
Andersson, G.B.5
Inoue, N.6
-
11
-
-
67749110199
-
An anatomical study of the mid-lateral pars relative to the pedicle footprint in the lower lumbar spine
-
Su BW, Kim PD, Cha TD, Lee J, April EW, Weidenbaum M, Vaccaro AR (2009) An anatomical study of the mid-lateral pars relative to the pedicle footprint in the lower lumbar spine. Spine (Phila Pa 1976) 34(13):1355–1362
-
(2009)
Spine (Phila Pa 1976)
, vol.34
, Issue.13
, pp. 1355-1362
-
-
Su, B.W.1
Kim, P.D.2
Cha, T.D.3
Lee, J.4
April, E.W.5
Weidenbaum, M.6
Vaccaro, A.R.7
-
12
-
-
14844353716
-
Accurate determination of isthmus of lumbar pedicle: a morphometric study using reformatted computed tomographic images
-
Li B, Jiang B, Fu Z, Zhang D, Wang T (2004) Accurate determination of isthmus of lumbar pedicle: a morphometric study using reformatted computed tomographic images. Spine (Phila Pa 1976) 29(21):2438–2444
-
(2004)
Spine (Phila Pa 1976)
, vol.29
, Issue.21
, pp. 2438-2444
-
-
Li, B.1
Jiang, B.2
Fu, Z.3
Zhang, D.4
Wang, T.5
-
13
-
-
37649008179
-
Does the shape of the L5 vertebral body depend on the height of CT slices in the pedicle? Evaluation of the shape of the L5 vertebral body with a multicut CT scan
-
Alfonso M, Palacio P, Bastarrika G, Villas C (2008) Does the shape of the L5 vertebral body depend on the height of CT slices in the pedicle? Evaluation of the shape of the L5 vertebral body with a multicut CT scan. Spine (Phila Pa 1976) 33(1):E1–E5
-
(2008)
Spine (Phila Pa 1976)
, vol.33
, Issue.1
, pp. E1-E5
-
-
Alfonso, M.1
Palacio, P.2
Bastarrika, G.3
Villas, C.4
-
14
-
-
84881477180
-
Morphometric measurement of cortical bone trajectory for lumbar pedicle screw insertion using computed tomography
-
PID: 23429319
-
Matsukawa K, Yato Y, Nemoto O, Imabayashi H, Asazuma T, Nemoto K (2013) Morphometric measurement of cortical bone trajectory for lumbar pedicle screw insertion using computed tomography. J Spinal Disord Tech 26(6):E248–E253
-
(2013)
J Spinal Disord Tech
, vol.26
, Issue.6
, pp. E248-E253
-
-
Matsukawa, K.1
Yato, Y.2
Nemoto, O.3
Imabayashi, H.4
Asazuma, T.5
Nemoto, K.6
-
15
-
-
0033503395
-
Pedicle screw placement at the sacrum: anatomical characterization and limitations at S1
-
COI: 1:STN:280:DyaK1MzhtVWnuw%3D%3D, PID: 10382776
-
Robertson PA, Plank LD (1999) Pedicle screw placement at the sacrum: anatomical characterization and limitations at S1. J Spinal Disord 12(3):227–233
-
(1999)
J Spinal Disord
, vol.12
, Issue.3
, pp. 227-233
-
-
Robertson, P.A.1
Plank, L.D.2
-
16
-
-
0025890130
-
Surgical anatomy of the sacrum: a guide for rational screw fixation
-
COI: 1:STN:280:DyaK3MzitVansA%3D%3D
-
Esses SI, Botsford DJ, Huler RJ, Rauschning W (1991) Surgical anatomy of the sacrum: a guide for rational screw fixation. Spine (Phila Pa 1976) 16(6 Suppl):S283–S288
-
(1991)
Spine (Phila Pa 1976)
, vol.16
, pp. S283-S288
-
-
Esses, S.I.1
Botsford, D.J.2
Huler, R.J.3
Rauschning, W.4
-
17
-
-
0032076151
-
The internal bony architecture of the sacrum
-
COI: 1:STN:280:DyaK1c3ltFCgug%3D%3D
-
Peretz AM, Hipp JA, Heggeness MH (1998) The internal bony architecture of the sacrum. Spine (Phila Pa 1976) 23(9):971–974
-
(1998)
Spine (Phila Pa 1976)
, vol.23
, Issue.9
, pp. 971-974
-
-
Peretz, A.M.1
Hipp, J.A.2
Heggeness, M.H.3
-
18
-
-
0033951314
-
Variation in bone mineral density of the sacrum in young adults and its significance for sacral fixation
-
COI: 1:STN:280:DC%2BD3c7mslOmtg%3D%3D
-
Zheng Y, Lu WW, Zhu Q, Qin L, Zhong S, Leong JC (2000) Variation in bone mineral density of the sacrum in young adults and its significance for sacral fixation. Spine (Phila Pa 1976) 25(3):353–357
-
(2000)
Spine (Phila Pa 1976)
, vol.25
, Issue.3
, pp. 353-357
-
-
Zheng, Y.1
Lu, W.W.2
Zhu, Q.3
Qin, L.4
Zhong, S.5
Leong, J.C.6
-
19
-
-
0033954922
-
Internal architecture of the sacrum in the elderly. An anatomic and radiographic study
-
COI: 1:STN:280:DC%2BD3c7mslOntg%3D%3D
-
Ebraheim N, Sabry FF, Nadim Y, Xu R, Yeasting RA (2000) Internal architecture of the sacrum in the elderly. An anatomic and radiographic study. Spine (Phila Pa 1976) 25(3):292–297
-
(2000)
Spine (Phila Pa 1976)
, vol.25
, Issue.3
, pp. 292-297
-
-
Ebraheim, N.1
Sabry, F.F.2
Nadim, Y.3
Xu, R.4
Yeasting, R.A.5
-
20
-
-
84905495112
-
Cortical bone trajectory for lumbosacral fixation: penetrating S-1 endplate screw technique: technical note
-
PID: 24766288
-
Matsukawa K, Yato Y, Kato T, Imabayashi H, Asazuma T, Nemoto K (2014) Cortical bone trajectory for lumbosacral fixation: penetrating S-1 endplate screw technique: technical note. J Neurosurg Spine 21(2):203–209
-
(2014)
J Neurosurg Spine
, vol.21
, Issue.2
, pp. 203-209
-
-
Matsukawa, K.1
Yato, Y.2
Kato, T.3
Imabayashi, H.4
Asazuma, T.5
Nemoto, K.6
-
21
-
-
84881012172
-
The “medio-latero-superior trajectory technique”: an alternative cortical trajectory for pedicle fixation
-
Mobbs RJ (2013) The “medio-latero-superior trajectory technique”: an alternative cortical trajectory for pedicle fixation. Orthopaed Surg 5(1):56–59
-
(2013)
Orthopaed Surg
, vol.5
, Issue.1
, pp. 56-59
-
-
Mobbs, R.J.1
-
22
-
-
84907562798
-
Hybrid technique of cortical bone trajectory and pedicle screwing for minimally invasive spine reconstruction surgery: a technical note
-
Takata Y, Matsuura T, Higashino K, Sakai T, Mishiro T, Suzue N et al (2014) Hybrid technique of cortical bone trajectory and pedicle screwing for minimally invasive spine reconstruction surgery: a technical note. J Med Investig JMI 61(3–4):388–392
-
(2014)
J Med Investig JMI
, vol.61
, Issue.3-4
, pp. 388-392
-
-
Takata, Y.1
Matsuura, T.2
Higashino, K.3
Sakai, T.4
Mishiro, T.5
Suzue, N.6
-
23
-
-
84897667745
-
Novel placement of cortical bone trajectory screws in previously instrumented pedicles for adjacent-segment lumbar disease using CT image-guided navigation
-
PID: 24580010
-
Rodriguez A, Neal MT, Liu A, Somasundaram A, Hsu W, Branch CL Jr (2014) Novel placement of cortical bone trajectory screws in previously instrumented pedicles for adjacent-segment lumbar disease using CT image-guided navigation. Neurosurg Focus 36(3):E9
-
(2014)
Neurosurg Focus
, vol.36
, Issue.3
, pp. E9
-
-
Rodriguez, A.1
Neal, M.T.2
Liu, A.3
Somasundaram, A.4
Hsu, W.5
Branch, C.L.6
|