-
1
-
-
84907035999
-
Computer-aided fixation of spinal implants
-
L.P. Nolte, H. Visarius, E. Arm, F. Langlotz, O. Schwarzenbach, and L. Zamorano Computer-aided fixation of spinal implants J Image Guid Surg 1 1995 88 93
-
(1995)
J Image Guid Surg
, vol.1
, pp. 88-93
-
-
Nolte, L.P.1
Visarius, H.2
Arm, E.3
Langlotz, F.4
Schwarzenbach, O.5
Zamorano, L.6
-
2
-
-
0002880775
-
A new approach to computer-aided spine surgery: Fluoroscopy-based surgical navigation
-
L.P. Nolte, M.A. Slomczykowski, U. Berlemann, and et al. A new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation Eur Spine J 9 Suppl. 1 2000 S78 88
-
(2000)
Eur Spine J
, vol.9
, pp. S78-S88
-
-
Nolte, L.P.1
Slomczykowski, M.A.2
Berlemann, U.3
-
3
-
-
79953862902
-
Clinical and methodological precision of spinal navigation assisted by 3D intraoperative O-arm radiographic imaging
-
M.F. Oertel, J. Hobart, M. Stein, V. Schreiber, and W. Scharbrodt Clinical and methodological precision of spinal navigation assisted by 3D intraoperative O-arm radiographic imaging J Neurosurg Spine 14 2011 532 536
-
(2011)
J Neurosurg Spine
, vol.14
, pp. 532-536
-
-
Oertel, M.F.1
Hobart, J.2
Stein, M.3
Schreiber, V.4
Scharbrodt, W.5
-
4
-
-
2342535057
-
Intraoperative Iso-C C-arm navigation in craniospinal surgery: The first 60 cases
-
J.S. Hott, V.R. Deshmukh, J.D. Klopfenstein, and et al. Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases Neurosurgery 54 2004 1131 1136
-
(2004)
Neurosurgery
, vol.54
, pp. 1131-1136
-
-
Hott, J.S.1
Deshmukh, V.R.2
Klopfenstein, J.D.3
-
6
-
-
40949104442
-
The 2007 recommendations of the International Commission on Radiological Protection. ICRP publication 103
-
Anonymous The 2007 recommendations of the International Commission on Radiological Protection. ICRP publication 103 Ann ICRP 37 2007 1 332
-
(2007)
Ann ICRP
, vol.37
, pp. 1-332
-
-
-
7
-
-
0141563573
-
Occupational exposure from common fluoroscopic projections used in orthopaedic surgery
-
N. Theocharopoulos, K. Perisinakis, J. Damilakis, G. Papadokostakis, A. Hadjipavlou, and N. Gourtsoyiannis Occupational exposure from common fluoroscopic projections used in orthopaedic surgery J Bone Joint Surg Am 85-A 2003 1698 1703
-
(2003)
J Bone Joint Surg Am
, vol.85A
, pp. 1698-1703
-
-
Theocharopoulos, N.1
Perisinakis, K.2
Damilakis, J.3
Papadokostakis, G.4
Hadjipavlou, A.5
Gourtsoyiannis, N.6
-
8
-
-
33646590640
-
Ionising radiation exposure to orthopaedic trainees: The effect of sub-specialty training
-
M.J. Oddy, and C.H. Aldam Ionising radiation exposure to orthopaedic trainees: the effect of sub-specialty training Ann R Coll Surg Engl 88 2006 297 301
-
(2006)
Ann R Coll Surg Engl
, vol.88
, pp. 297-301
-
-
Oddy, M.J.1
Aldam, C.H.2
-
9
-
-
0034667336
-
Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion
-
Y.R. Rampersaud, K.T. Foley, Shen A.C., S. Williams, and M. Solomito Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion Spine 25 2000 2637 2645
-
(2000)
Spine
, vol.25
, pp. 2637-2645
-
-
Rampersaud, Y.R.1
Foley, K.T.2
Shen, A.C.3
Williams, S.4
Solomito, M.5
-
10
-
-
84875898496
-
Use of CT-based intraoperative spinal navigation: Management of radiation exposure to operator, staff, and patients
-
J.R. Bandela, R.P. Jacob, M. Arreola, T.M. Griglock, F. Bova, and Yang M. Use of CT-based intraoperative spinal navigation: management of radiation exposure to operator, staff, and patients World Neurosurg 79 2013 390 394
-
(2013)
World Neurosurg
, vol.79
, pp. 390-394
-
-
Bandela, J.R.1
Jacob, R.P.2
Arreola, M.3
Griglock, T.M.4
Bova, F.5
Yang, M.6
-
11
-
-
85043113579
-
Fluoroscopic radiation exposure in spinal surgery: In vivo evaluation for operating room personnel
-
D.S. Mulconrey Fluoroscopic radiation exposure in spinal surgery: in vivo evaluation for operating room personnel J Spinal Disord Tech 2013
-
(2013)
J Spinal Disord Tech
-
-
Mulconrey, D.S.1
-
12
-
-
0027484342
-
Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members
-
S.I. Esses, B.L. Sachs, and V. Dreyzin Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members Spine 18 1993 2231 2238
-
(1993)
Spine
, vol.18
, pp. 2231-2238
-
-
Esses, S.I.1
Sachs, B.L.2
Dreyzin, V.3
-
13
-
-
84923850524
-
Position and complications of pedicle screw insertion with or without image-navigation techniques in the thoracolumbar spine: A meta-analysis of comparative studies
-
Tang J., Zhu Z., T. Sui, Kong D., and Cao X. Position and complications of pedicle screw insertion with or without image-navigation techniques in the thoracolumbar spine: a meta-analysis of comparative studies J Biomed Res 28 2014 228 239
-
(2014)
J Biomed Res
, vol.28
, pp. 228-239
-
-
Tang, J.1
Zhu, Z.2
Sui, T.3
Kong, D.4
Cao, X.5
-
14
-
-
84893337997
-
The accuracy of pedicle screw placement using intraoperative image guidance systems
-
A. Mason, R. Paulsen, J.M. Babuska, and et al. The accuracy of pedicle screw placement using intraoperative image guidance systems J Neurosurg Spine 20 2014 196 203
-
(2014)
J Neurosurg Spine
, vol.20
, pp. 196-203
-
-
Mason, A.1
Paulsen, R.2
Babuska, J.M.3
-
15
-
-
84861304427
-
Accuracy of pedicle screw placement: A systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques
-
I.D. Gelalis, N.K. Paschos, E.E. Pakos, and et al. Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques Eur Spine J 21 2012 247 255
-
(2012)
Eur Spine J
, vol.21
, pp. 247-255
-
-
Gelalis, I.D.1
Paschos, N.K.2
Pakos, E.E.3
-
16
-
-
17044434219
-
Measurement of effective dose for paediatric scoliotic patients
-
L. Chih-I, D. McLean, and J. Robinson Measurement of effective dose for paediatric scoliotic patients Radiography 11 2005 89 97
-
(2005)
Radiography
, vol.11
, pp. 89-97
-
-
Chih-I, L.1
McLean, D.2
Robinson, J.3
-
17
-
-
84901806922
-
A survey of organ equivalent and effective doses from diagnostic radiology procedures
-
E.K. Osei, and J. Darko A survey of organ equivalent and effective doses from diagnostic radiology procedures ISRN Radiol 2013 2013 1 9
-
(2013)
ISRN Radiol
, vol.2013
, pp. 1-9
-
-
Osei, E.K.1
Darko, J.2
-
18
-
-
67650536250
-
Ionizing radiation exposure of the population of the United States
-
Bethesda, MD
-
National Council of Radiation Protection and Measurements Ionizing radiation exposure of the population of the United States NCRP Report No 160, Bethesda, MD 2009
-
(2009)
NCRP Report No 160
-
-
-
19
-
-
51549112607
-
The measurement, reporting, and management of radiation dose in CT
-
College Park, MD
-
American Association of Physicists in Medicine The measurement, reporting, and management of radiation dose in CT AAPM Report No 96, College Park, MD 2008
-
(2008)
AAPM Report No 96
-
-
-
20
-
-
84877881640
-
Comparison between percutaneous and traditional fixation of lumbar spine fracture: Intraoperative radiation exposure levels and outcomes
-
N. Bronsard, T. Boli, M. Challali, and et al. Comparison between percutaneous and traditional fixation of lumbar spine fracture: intraoperative radiation exposure levels and outcomes Orthop Traumatol Surg Res 99 2013 162 168
-
(2013)
Orthop Traumatol Surg Res
, vol.99
, pp. 162-168
-
-
Bronsard, N.1
Boli, T.2
Challali, M.3
-
21
-
-
84884363647
-
Minimally invasive transforaminal lumbar interbody fusions and fluoroscopy: A low-dose protocol to minimize ionizing radiation
-
J.C. Clark, G. Jasmer, F.F. Marciano, and L.M. Tumialan Minimally invasive transforaminal lumbar interbody fusions and fluoroscopy: a low-dose protocol to minimize ionizing radiation Neurosurg Focus 35 2013 E8
-
(2013)
Neurosurg Focus
, vol.35
, pp. E8
-
-
Clark, J.C.1
Jasmer, G.2
Marciano, F.F.3
Tumialan, L.M.4
-
22
-
-
79959470062
-
Fluoroscopic exposure in modern spinal surgery
-
P. Fransen Fluoroscopic exposure in modern spinal surgery Acta Orthop Belg 77 2011 386 389
-
(2011)
Acta Orthop Belg
, vol.77
, pp. 386-389
-
-
Fransen, P.1
-
23
-
-
3242676907
-
Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion
-
K. Perisinakis, N. Theocharopoulos, J. Damilakis, and et al. Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion Spine 29 2004 1555 1560
-
(2004)
Spine
, vol.29
, pp. 1555-1560
-
-
Perisinakis, K.1
Theocharopoulos, N.2
Damilakis, J.3
-
24
-
-
84902544564
-
Comparative radiation exposure using standard fluoroscopy versus cone-beam computed tomography for posterior instrumented fusion in adolescent idiopathic scoliosis
-
C. O'Donnell, A. Maertens, V. Bompadre, T.A. Wagner, and W. Krengel 3rd. Comparative radiation exposure using standard fluoroscopy versus cone-beam computed tomography for posterior instrumented fusion in adolescent idiopathic scoliosis Spine 39 2014 E850 5
-
(2014)
Spine
, vol.39
, pp. E850-E855
-
-
O'Donnell, C.1
Maertens, A.2
Bompadre, V.3
Wagner, T.A.4
Krengel, W.5
-
25
-
-
84901829762
-
Comparison of the clinical outcome in overweight or obese patients after minimally invasive versus open transforaminal lumbar interbody fusion
-
Wang J., Zhou Y., Z. Feng Zhang, C. Qing Li, W. Jie Zheng, and Liu J. Comparison of the clinical outcome in overweight or obese patients after minimally invasive versus open transforaminal lumbar interbody fusion J Spinal Disord Tech 27 2014 202 206
-
(2014)
J Spinal Disord Tech
, vol.27
, pp. 202-206
-
-
Wang, J.1
Zhou, Y.2
Feng Zhang, Z.3
Qing Li, C.4
Jie Zheng, W.5
Liu, J.6
-
26
-
-
84901012136
-
Reduction in radiation during percutaneous lumbar pedicle screw placement using a new device
-
Zhang L., Zhou X., Cai X., Zhang H., Fu Q., and He S. Reduction in radiation during percutaneous lumbar pedicle screw placement using a new device Minim Invasive Ther Allied Technol 23 2014 173 178
-
(2014)
Minim Invasive Ther Allied Technol
, vol.23
, pp. 173-178
-
-
Zhang, L.1
Zhou, X.2
Cai, X.3
Zhang, H.4
Fu, Q.5
He, S.6
-
27
-
-
84944889705
-
Percutaneous pedicle screw placement in lumbar spine: A comparison study between the novel guidance system and the conventional fluoroscopy method
-
Gu G., Zhang H., He S., and et al. Percutaneous pedicle screw placement in lumbar spine: a comparison study between the novel guidance system and the conventional fluoroscopy method J Spinal Disord Tech 28 2013 E522 7
-
(2013)
J Spinal Disord Tech
, vol.28
, pp. E522-E527
-
-
Gu, G.1
Zhang, H.2
He, S.3
-
28
-
-
84880046774
-
Comparison of isocentric C-arm 3-dimensional navigation and conventional fluoroscopy for C1 lateral mass and C2 pedicle screw placement for atlantoaxial instability
-
Yang Y.L., Zhou D.S., and He J.L. Comparison of isocentric C-arm 3-dimensional navigation and conventional fluoroscopy for C1 lateral mass and C2 pedicle screw placement for atlantoaxial instability J Spinal Disord Tech 26 2013 127 134
-
(2013)
J Spinal Disord Tech
, vol.26
, pp. 127-134
-
-
Yang, Y.L.1
Zhou, D.S.2
He, J.L.3
-
29
-
-
84870189587
-
Percutaneous lumbar pedicle screw placement aided by computer-assisted fluoroscopy-based navigation: Perioperative results of a prospective, comparative, multicenter study
-
Yang B.P., M.M. Wahl, and C.S. Idler Percutaneous lumbar pedicle screw placement aided by computer-assisted fluoroscopy-based navigation: perioperative results of a prospective, comparative, multicenter study Spine 37 2012 2055 2060
-
(2012)
Spine
, vol.37
, pp. 2055-2060
-
-
Yang, B.P.1
Wahl, M.M.2
Idler, C.S.3
-
30
-
-
84872321305
-
Minimally invasive transforaminal lumbar interbody fusion aided with computer-assisted spinal navigation system combined with electromyography monitoring
-
Luo W., Zhang F., Liu T., Du X.L., Chen A.M., and Li F. Minimally invasive transforaminal lumbar interbody fusion aided with computer-assisted spinal navigation system combined with electromyography monitoring Chin Med J 125 2012 3947 3951
-
(2012)
Chin Med J
, vol.125
, pp. 3947-3951
-
-
Luo, W.1
Zhang, F.2
Liu, T.3
Du, X.L.4
Chen, A.M.5
Li, F.6
-
31
-
-
84878892368
-
Fluoroscopy for transpedicular screw placement in scoliosis: To what extent can radiation exposure be reduced by the freehand technique?
-
T. Ege, S. Bilgic, K. Koca, and et al. Fluoroscopy for transpedicular screw placement in scoliosis: to what extent can radiation exposure be reduced by the freehand technique? Turk Neurosurg 23 2013 344 348
-
(2013)
Turk Neurosurg
, vol.23
, pp. 344-348
-
-
Ege, T.1
Bilgic, S.2
Koca, K.3
-
32
-
-
79956210866
-
Minimally invasive or open transforaminal lumbar interbody fusion as revision surgery for patients previously treated by open discectomy and decompression of the lumbar spine
-
Wang J., Zhou Y., Zhang Z.F., Li C.Q., Zheng W.J., and Liu J. Minimally invasive or open transforaminal lumbar interbody fusion as revision surgery for patients previously treated by open discectomy and decompression of the lumbar spine Eur Spine J 20 2011 623 628
-
(2011)
Eur Spine J
, vol.20
, pp. 623-628
-
-
Wang, J.1
Zhou, Y.2
Zhang, Z.F.3
Li, C.Q.4
Zheng, W.J.5
Liu, J.6
-
33
-
-
78349304254
-
Comparison of one-level minimally invasive and open transforaminal lumbar interbody fusion in degenerative and isthmic spondylolisthesis grades 1 and 2
-
Wang J., Zhou Y., Zhang Z.F., Li C.Q., Zheng W.J., and Liu J. Comparison of one-level minimally invasive and open transforaminal lumbar interbody fusion in degenerative and isthmic spondylolisthesis grades 1 and 2 Eur Spine J 19 2010 1780 1784
-
(2010)
Eur Spine J
, vol.19
, pp. 1780-1784
-
-
Wang, J.1
Zhou, Y.2
Zhang, Z.F.3
Li, C.Q.4
Zheng, W.J.5
Liu, J.6
-
34
-
-
58849164909
-
Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion
-
R.K. Bindal, S. Glaze, M. Ognoskie, V. Tunner, R. Malone, and S. Ghosh Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion J Neurosurg Spine 9 2008 570 573
-
(2008)
J Neurosurg Spine
, vol.9
, pp. 570-573
-
-
Bindal, R.K.1
Glaze, S.2
Ognoskie, M.3
Tunner, V.4
Malone, R.5
Ghosh, S.6
-
35
-
-
45949103909
-
Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery
-
C.W. Kim, Y.P. Lee, W. Taylor, A. Oygar, and W.K. Kim Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery Spine J 8 2008 584 590
-
(2008)
Spine J
, vol.8
, pp. 584-590
-
-
Kim, C.W.1
Lee, Y.P.2
Taylor, W.3
Oygar, A.4
Kim, W.K.5
-
36
-
-
35948933032
-
Fluoroscopy-based navigation system in spine surgery
-
P. Merloz, J. Troccaz, H. Vouaillat, and et al. Fluoroscopy-based navigation system in spine surgery Proc Inst Mech Eng [H] 221 2007 813 820
-
(2007)
Proc Inst Mech Eng [H]
, vol.221
, pp. 813-820
-
-
Merloz, P.1
Troccaz, J.2
Vouaillat, H.3
-
37
-
-
32944477651
-
Utility of computerized isocentric fluoroscopy for minimally invasive spinal surgical techniques
-
A.T. Villavicencio, S. Burneikiene, K.R. Bulsara, and J.J. Thramann Utility of computerized isocentric fluoroscopy for minimally invasive spinal surgical techniques J Spinal Disord Tech 18 2005 369 375
-
(2005)
J Spinal Disord Tech
, vol.18
, pp. 369-375
-
-
Villavicencio, A.T.1
Burneikiene, S.2
Bulsara, K.R.3
Thramann, J.J.4
-
38
-
-
84902258273
-
Radiation exposure to the surgeon and the patient during posterior lumbar spinal instrumentation: A prospective randomized comparison of navigated versus non-navigated freehand techniques
-
J. Villard, Y.M. Ryang, A.K. Demetriades, and et al. Radiation exposure to the surgeon and the patient during posterior lumbar spinal instrumentation: a prospective randomized comparison of navigated versus non-navigated freehand techniques Spine 39 2014 1004 1009
-
(2014)
Spine
, vol.39
, pp. 1004-1009
-
-
Villard, J.1
Ryang, Y.M.2
Demetriades, A.K.3
-
39
-
-
84897047102
-
Can radiation exposure to the surgeon be reduced with freehand pedicle screw fixation technique in pediatric spinal deformity correction? A prospective multicenter study
-
H.Y. Erken, H. Burc, G. Saka, I. Akmaz, and M. Aydogan Can radiation exposure to the surgeon be reduced with freehand pedicle screw fixation technique in pediatric spinal deformity correction? A prospective multicenter study Spine 39 2014 521 525
-
(2014)
Spine
, vol.39
, pp. 521-525
-
-
Erken, H.Y.1
Burc, H.2
Saka, G.3
Akmaz, I.4
Aydogan, M.5
-
40
-
-
77955574857
-
Can computer-assisted surgery reduce the effective dose for spinal fusion and sacroiliac screw insertion?
-
M.D. Kraus, G. Krischak, P. Keppler, F.T. Gebhard, and U.H. Schuetz Can computer-assisted surgery reduce the effective dose for spinal fusion and sacroiliac screw insertion? Clin Orthop Relat Res 468 2010 2419 2429
-
(2010)
Clin Orthop Relat Res
, vol.468
, pp. 2419-2429
-
-
Kraus, M.D.1
Krischak, G.2
Keppler, P.3
Gebhard, F.T.4
Schuetz, U.H.5
-
41
-
-
33749519625
-
Radiation exposure during pedicle screw placement in adolescent idiopathic scoliosis: Is fluoroscopy safe?
-
M. Ul Haque, H.L. Shufflebarger, M. O'Brien, and A. Macagno Radiation exposure during pedicle screw placement in adolescent idiopathic scoliosis: is fluoroscopy safe? Spine 31 2006 2516 2520
-
(2006)
Spine
, vol.31
, pp. 2516-2520
-
-
Ul Haque, M.1
Shufflebarger, H.L.2
O'Brien, M.3
Macagno, A.4
-
42
-
-
68349104323
-
Image-guided pedicle screw insertion accuracy: A meta-analysis
-
Tian N.F., and Xu H.Z. Image-guided pedicle screw insertion accuracy: a meta-analysis Int Orthop 33 2009 895 903
-
(2009)
Int Orthop
, vol.33
, pp. 895-903
-
-
Tian, N.F.1
Xu, H.Z.2
-
43
-
-
33846683025
-
Pedicle screw placement accuracy: A meta-analysis
-
V. Kosmopoulos, and C. Schizas Pedicle screw placement accuracy: a meta-analysis Spine 32 2007 E111 20
-
(2007)
Spine
, vol.32
, pp. E111-E120
-
-
Kosmopoulos, V.1
Schizas, C.2
-
44
-
-
84962955913
-
Economic evaluation of intraoperative cone beam CT-based navigation for the placement of spinal pedicle screws: A patient level cost effectiveness analysis
-
N. Dea, C. Fisher, J. Batke, and J. Street Economic evaluation of intraoperative cone beam CT-based navigation for the placement of spinal pedicle screws: a patient level cost effectiveness analysis Global Spine Congress Abstract 2015
-
(2015)
Global Spine Congress Abstract
-
-
Dea, N.1
Fisher, C.2
Batke, J.3
Street, J.4
-
45
-
-
77951143798
-
Functional outcome of computer-assisted spinal pedicle screw placement: A systematic review and meta-analysis of 23 studies including 5,992 pedicle screws
-
R. Verma, S. Krishan, K. Haendlmayer, and A. Mohsen Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws Eur Spine J 19 2010 370 375
-
(2010)
Eur Spine J
, vol.19
, pp. 370-375
-
-
Verma, R.1
Krishan, S.2
Haendlmayer, K.3
Mohsen, A.4
-
46
-
-
84901261284
-
Does less invasive spine surgery result in increased radiation exposure? A systematic review
-
Yu E., and S.N. Khan Does less invasive spine surgery result in increased radiation exposure? A systematic review Clin Orthop Relat Res 472 2014 1738 1748
-
(2014)
Clin Orthop Relat Res
, vol.472
, pp. 1738-1748
-
-
Yu, E.1
Khan, S.N.2
-
47
-
-
58149291992
-
Comparison of radiation exposure in lumbar pedicle screw placement with fluoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging
-
H.E. Smith, M.D. Welsch, R.C. Sasso, and A.R. Vaccaro Comparison of radiation exposure in lumbar pedicle screw placement with fluoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging J Spinal Cord Med 31 2008 532 537
-
(2008)
J Spinal Cord Med
, vol.31
, pp. 532-537
-
-
Smith, H.E.1
Welsch, M.D.2
Sasso, R.C.3
Vaccaro, A.R.4
-
48
-
-
33748079472
-
Does computer-assisted spine surgery reduce intraoperative radiation doses?
-
F.T. Gebhard, M.D. Kraus, E. Schneider, U.C. Liener, L. Kinzl, and M. Arand Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine 31 2006 2024 2027
-
(2006)
Spine
, vol.31
, pp. 2024-2027
-
-
Gebhard, F.T.1
Kraus, M.D.2
Schneider, E.3
Liener, U.C.4
Kinzl, L.5
Arand, M.6
-
49
-
-
0842348097
-
Risk of cancer from diagnostic X-rays: Estimates for the UK and 14 other countries
-
A. Berrington de Gonzalez, and S. Darby Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries Lancet 363 2004 345 351
-
(2004)
Lancet
, vol.363
, pp. 345-351
-
-
Berrington De Gonzalez, A.1
Darby, S.2
-
50
-
-
0034071315
-
Assessing exposure to cosmic radiation during long-haul flights
-
J.F. Bottollier-Depois, Q. Chau, P. Bouisset, G. Kerlau, L. Plawinski, and L. Lebaron-Jacobs Assessing exposure to cosmic radiation during long-haul flights Radiat Res 153 2000 526 532
-
(2000)
Radiat Res
, vol.153
, pp. 526-532
-
-
Bottollier-Depois, J.F.1
Chau, Q.2
Bouisset, P.3
Kerlau, G.4
Plawinski, L.5
Lebaron-Jacobs, L.6
-
51
-
-
79961066961
-
Radiation exposure issues in orthopaedics
-
1-10
-
B.D. Giordano, J.N. Grauer, C.P. Miller, T.L. Morgan, and G.R. Rechtine 2nd. Radiation exposure issues in orthopaedics J Bone Joint Surg Am 93 2011 e69 1-10
-
(2011)
J Bone Joint Surg Am
, vol.93
, pp. e69
-
-
Giordano, B.D.1
Grauer, J.N.2
Miller, C.P.3
Morgan, T.L.4
Rechtine, G.R.5
-
52
-
-
78649742049
-
Cumulative effective dose associated with radiography and CT of adolescents with spinal injuries
-
S.P. Lemburg, S.A. Peters, D. Roggenland, V. Nicolas, and C.M. Heyer Cumulative effective dose associated with radiography and CT of adolescents with spinal injuries AJR Am J Roentgenol 195 2010 1411 1417
-
(2010)
AJR Am J Roentgenol
, vol.195
, pp. 1411-1417
-
-
Lemburg, S.P.1
Peters, S.A.2
Roggenland, D.3
Nicolas, V.4
Heyer, C.M.5
-
53
-
-
33846197520
-
Radiation exposure from diagnostic imaging in severely injured trauma patients
-
H.C. Tien, L.N. Tremblay, S.B. Rizoli, and et al. Radiation exposure from diagnostic imaging in severely injured trauma patients J Trauma 62 2007 151 156
-
(2007)
J Trauma
, vol.62
, pp. 151-156
-
-
Tien, H.C.1
Tremblay, L.N.2
Rizoli, S.B.3
-
54
-
-
84876416562
-
Radiation exposure to the surgeon during percutaneous endoscopic lumbar discectomy: A prospective study
-
Y. Ahn, C.H. Kim, J.H. Lee, S.H. Lee, and J.S. Kim Radiation exposure to the surgeon during percutaneous endoscopic lumbar discectomy: a prospective study Spine 38 2013 617 625
-
(2013)
Spine
, vol.38
, pp. 617-625
-
-
Ahn, Y.1
Kim, C.H.2
Lee, J.H.3
Lee, S.H.4
Kim, J.S.5
-
55
-
-
84873576215
-
Worldwide survey on the use of navigation in spine surgery
-
R. Hartl, K.S. Lam, Wang J., A. Korge, F. Kandziora, and L. Audige Worldwide survey on the use of navigation in spine surgery World Neurosurg 79 2013 162 172
-
(2013)
World Neurosurg
, vol.79
, pp. 162-172
-
-
Hartl, R.1
Lam, K.S.2
Wang, J.3
Korge, A.4
Kandziora, F.5
Audige, L.6
-
56
-
-
84962936462
-
-
Washington DC
-
Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation, Board on Radiation Effects Research, Division on Earth and Life Studies, and NATIONAL RESEARCH COUNCIL OF THE NATIONAL ACADEMIES BEIR VII, Phase I, Letter Report (1998) Washington DC 1998
-
(1998)
BEIR VII, Phase I, Letter Report (1998)
-
-
Division on Earth and Life Studies1
-
57
-
-
84856752846
-
Optimization of radiation exposure and image quality of the cone-beam O-arm intraoperative imaging system in spinal surgery
-
K. Abul-Kasim, M. Soderberg, E. Selariu, M. Gunnarsson, M. Kherad, and A. Ohlin Optimization of radiation exposure and image quality of the cone-beam O-arm intraoperative imaging system in spinal surgery J Spinal Disord Tech 25 2012 52 58
-
(2012)
J Spinal Disord Tech
, vol.25
, pp. 52-58
-
-
Abul-Kasim, K.1
Soderberg, M.2
Selariu, E.3
Gunnarsson, M.4
Kherad, M.5
Ohlin, A.6
-
58
-
-
0033562611
-
Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery
-
M. Slomczykowski, M. Roberto, P. Schneeberger, C. Ozdoba, and P. Vock Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery Spine 24 1999 975 982
-
(1999)
Spine
, vol.24
, pp. 975-982
-
-
Slomczykowski, M.1
Roberto, M.2
Schneeberger, P.3
Ozdoba, C.4
Vock, P.5
-
59
-
-
84917697998
-
Radiation safety and spine surgery: Systematic review of exposure limits and methods to minimize radiation exposure
-
D. Srinivasan, K.D. Than, Wang A.C., and et al. Radiation safety and spine surgery: systematic review of exposure limits and methods to minimize radiation exposure World Neurosurg 82 2014 1337 1343
-
(2014)
World Neurosurg
, vol.82
, pp. 1337-1343
-
-
Srinivasan, D.1
Than, K.D.2
Wang, A.C.3
-
60
-
-
79960718881
-
Pause and pulse: Ten steps that help manage radiation dose during pediatric fluoroscopy
-
M. Hernanz-Schulman, M.J. Goske, I.H. Bercha, and K.J. Strauss Pause and pulse: ten steps that help manage radiation dose during pediatric fluoroscopy AJR Am J Roentgenol 197 2011 475 481
-
(2011)
AJR Am J Roentgenol
, vol.197
, pp. 475-481
-
-
Hernanz-Schulman, M.1
Goske, M.J.2
Bercha, I.H.3
Strauss, K.J.4
-
61
-
-
0037624000
-
Radiation dose reduction to medical staff during vertebroplasty: A review of techniques and methods to mitigate occupational dose
-
R. Kruger, and T. Faciszewski Radiation dose reduction to medical staff during vertebroplasty: a review of techniques and methods to mitigate occupational dose Spine 28 2003 1608 1613
-
(2003)
Spine
, vol.28
, pp. 1608-1613
-
-
Kruger, R.1
Faciszewski, T.2
-
62
-
-
0035044834
-
Inspection of lead aprons: Criteria for rejection
-
K. Lambert, and T. McKeon Inspection of lead aprons: criteria for rejection Health Phys 80 5 Suppl. 2001 S67 9
-
(2001)
Health Phys
, vol.80
, Issue.5
, pp. S67-S69
-
-
Lambert, K.1
McKeon, T.2
|