Volumn 29, Issue 14, 2004, Pages 1555-1560

Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion

Author keywords

Effective dose; Fluoroscopy; Gonadal dose; Pedicle screw insertion; Radiation risks

Indexed keywords

ADULT; ARTICLE; BONE SCREW; CANCER; CANCER RISK; CLINICAL ARTICLE; DOSIMETRY; EXPERIMENTAL MODEL; FEMALE; FLUOROSCOPY; GENDER; GONAD; HUMAN; HUMAN TISSUE; MALE; MEASUREMENT; OPERATION DURATION; OSTEOSYNTHESIS; PRIORITY JOURNAL; RADIATION DOSE; RADIATION EXPOSURE; RADIATION INJURY; RADIOSENSITIVITY; SAFETY; SKIN INJURY; SPINE DISEASE; SURGICAL TECHNIQUE; TISSUE LEVEL;

EID: 3242676907     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.BRS.0000131214.57597.21     Document Type: Article
Times cited : (114)

References (26)
  • 1
    • 0033794424 scopus 로고    scopus 로고
    • The use of Pedicle-screw internal fixation for the operative treatment of spinal disorders
    • Gaines RW. The use of Pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 2000;82:1458-76.
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 1458-1476
    • Gaines, R.W.1
  • 2
    • 0037227158 scopus 로고    scopus 로고
    • Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: Technique and short-term complications
    • Carbone JJ, Tortolani PJ, LG Quartararo. Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: Technique and short-term complications. Spine 2003;28:91-7.
    • (2003) Spine , vol.28 , pp. 91-97
    • Carbone, J.J.1    Tortolani, P.J.2    Quartararo, L.G.3
  • 3
    • 0033562611 scopus 로고    scopus 로고
    • Radiation dose for pedicle screw insertion: Fluoroscopic method versus computer-assisted surgery
    • Slomczykowski M, Mini R, Schneeberger P, et al. Radiation dose for pedicle screw insertion: fluoroscopic method versus computer-assisted surgery. Spine 1999;24:975-83.
    • (1999) Spine , vol.24 , pp. 975-983
    • Slomczykowski, M.1    Mini, R.2    Schneeberger, P.3
  • 4
    • 0032527481 scopus 로고    scopus 로고
    • Complications of pediatric thoracolumbar and lumbar pedicle screws
    • Brown CA, Lenke LG, Bridwell KH, et al. Complications of pediatric thoracolumbar and lumbar pedicle screws. Spine 1998;23:1566-71.
    • (1998) Spine , vol.23 , pp. 1566-1571
    • Brown, C.A.1    Lenke, L.G.2    Bridwell, K.H.3
  • 5
    • 0025930020 scopus 로고
    • Recommendations of the International Commission on Radiological Protection
    • International Commission on Radiological Protection. Recommendations of the International Commission on Radiological Protection. Ann ICRP 1990;21.
    • (1990) Ann ICRP , pp. 21
  • 6
    • 0031885073 scopus 로고    scopus 로고
    • A study of patient radiation doses in interventional radiological procedures
    • Mc Parland BJ. A study of patient radiation doses in interventional radiological procedures. Br J Radiol 1998;71:175-85.
    • (1998) Br J Radiol , vol.71 , pp. 175-185
    • Mc Parland, B.J.1
  • 7
    • 0032963530 scopus 로고    scopus 로고
    • Radiation dose in interventional fluoroscopic procedures
    • Geise RA, O'Dea TJ. Radiation dose in interventional fluoroscopic procedures. Appl Radiat Isot 1999;50:173-84.
    • (1999) Appl Radiat Isot , vol.50 , pp. 173-184
    • Geise, R.A.1    O'Dea, T.J.2
  • 8
    • 0035403070 scopus 로고    scopus 로고
    • Fluoroscopy. Patient radiation exposure issues
    • Mahesh M. Fluoroscopy. Patient radiation exposure issues. Radiographics 2001;21:1033-45.
    • (2001) Radiographics , vol.21 , pp. 1033-1045
    • Mahesh, M.1
  • 9
    • 0037833538 scopus 로고    scopus 로고
    • Radiation doses in interventional radiology procedures: The RAD-IR study: Part I: Overall measures of dose
    • Miller DL, Balter S, Cole PE, et al. Radiation doses in interventional radiology procedures: the RAD-IR study: part I: overall measures of dose. J Vasc Interv Radiol 2003;14:711-27.
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 711-727
    • Miller, D.L.1    Balter, S.2    Cole, P.E.3
  • 12
    • 0034436030 scopus 로고    scopus 로고
    • Avoidance of radiation injuries from medical interventional procedures
    • Valentin J. Avoidance of radiation injuries from medical interventional procedures. Ann ICRP 2000;30:7-67.
    • (2000) Ann ICRP , vol.30 , pp. 7-67
    • Valentin, J.1
  • 13
    • 0030228293 scopus 로고    scopus 로고
    • Radiation skin injuries from fluoroscopy
    • Shope B. Radiation skin injuries from fluoroscopy. Radiographics 1996;16:1195-9.
    • (1996) Radiographics , vol.16 , pp. 1195-1199
    • Shope, B.1
  • 14
    • 0034989324 scopus 로고    scopus 로고
    • Skin injuries from fluoroscopically guided procedures: Part 1, characteristics of radiation injury
    • Koenig TR, Wolff D, Mettler FA, Wagner LK. Skin injuries from fluoroscopically guided procedures: part 1, characteristics of radiation injury. Am J Roentgenol 2001;177:3-11.
    • (2001) Am J Roentgenol , vol.177 , pp. 3-11
    • Koenig, T.R.1    Wolff, D.2    Mettler, F.A.3    Wagner, L.K.4
  • 16
    • 0036828515 scopus 로고    scopus 로고
    • Minimizing radiation-induced skin injury in interventional radiology procedures
    • Miller DL, Balter S, Noonan PT, et al. Minimizing radiation-induced skin injury in interventional radiology procedures. Radiology 2002;225:329-36.
    • (2002) Radiology , vol.225 , pp. 329-336
    • Miller, D.L.1    Balter, S.2    Noonan, P.T.3
  • 17
    • 0033858074 scopus 로고    scopus 로고
    • Estimation of fetal radiation dose from computed tomography scanning in late pregnancy: Depth dose data from routine examinations
    • Damilakis J, Perisinakis K, Voloudaki A, et al. Estimation of fetal radiation dose from computed tomography scanning in late pregnancy: depth dose data from routine examinations. Invest Radiol 2000;35:527-33.
    • (2000) Invest Radiol , vol.35 , pp. 527-533
    • Damilakis, J.1    Perisinakis, K.2    Voloudaki, A.3
  • 18
    • 0023790873 scopus 로고
    • Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement
    • Weinstein JN, Spratt KF, Spengler D, et al. Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 1988;13:1012-8.
    • (1988) Spine , vol.13 , pp. 1012-1018
    • Weinstein, J.N.1    Spratt, K.F.2    Spengler, D.3
  • 19
    • 0036283764 scopus 로고    scopus 로고
    • Patient effective radiation dose and associated risk from transmission scans using Gd-153 line sources in cardiac SPECT studies
    • Perisinakis K, Theocharopoulos N, Karkavitsas N, et al. Patient effective radiation dose and associated risk from transmission scans using Gd-153 line sources in cardiac SPECT studies. Health Phys 2002;83:847-53.
    • (2002) Health Phys , vol.83 , pp. 847-853
    • Perisinakis, K.1    Theocharopoulos, N.2    Karkavitsas, N.3
  • 22
    • 0004618846 scopus 로고
    • Biological effects of high x-ray doses
    • Balter S, Shope T, eds. Oak Brook, IL: Radiological Society of North America
    • Wagner LK. Biological effects of high x-ray doses. In: Balter S, Shope T, eds. Syllabus: A Categorical Course in Physics. Oak Brook, IL: Radiological Society of North America; 1995:167-70.
    • (1995) Syllabus: A Categorical Course in Physics , pp. 167-170
    • Wagner, L.K.1
  • 23
    • 0343526789 scopus 로고    scopus 로고
    • Radiation exposure during fluoroscopically assisted pedicle screw insertion in the lumbar spine
    • Jones DP, Robertson PA, Lunt B, et al. Radiation exposure during fluoroscopically assisted pedicle screw insertion in the lumbar spine. Spine 2000;25:1538-41.
    • (2000) Spine , vol.25 , pp. 1538-1541
    • Jones, D.P.1    Robertson, P.A.2    Lunt, B.3
  • 24
    • 0000928327 scopus 로고
    • Hereditary effects of radiation
    • Hall EJ, ed. Philadelphia, PA: J.B. Lippincott Co
    • Hall EJ. Hereditary effects of radiation. In: Hall EJ, ed. Radiobiology for the Radiologist. Philadelphia, PA: J.B. Lippincott Co; 1994.
    • (1994) Radiobiology for the Radiologist
    • Hall, E.J.1
  • 25
    • 0029895158 scopus 로고    scopus 로고
    • Prediction of scoliotic Cobb angle with the use of the scoliometer
    • Korovessis PG, Stamatakis MV. Prediction of scoliotic Cobb angle with the use of the scoliometer. Spine 1996;21:1661-6.
    • (1996) Spine , vol.21 , pp. 1661-1666
    • Korovessis, P.G.1    Stamatakis, M.V.2
  • 26
    • 0035102006 scopus 로고    scopus 로고
    • Prediction of thoracic kyphosis using the Debrunner kyphometer
    • Korovessis P, Petsinis G, Papazisis, et al. Prediction of thoracic kyphosis using the Debrunner kyphometer. J Spinal Disord 2001;14:67-72.
    • (2001) J Spinal Disord , vol.14 , pp. 67-72
    • Korovessis, P.1    Petsinis, G.2    Papazisis3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.