-
1
-
-
0017871668
-
Atlanto-axial arthrodesis by the wedge compression method
-
Brooks AL, Jenkins EB. Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am. 1978;60:279-284.
-
(1978)
J Bone Joint Surg Am
, vol.60
, pp. 279-284
-
-
Brooks, A.L.1
Jenkins, E.B.2
-
2
-
-
1442275221
-
Skeletal traction in the treatment of fractures and dislocations of the cervical spine
-
Gallie WE. Skeletal traction in the treatment of fractures and dislocations of the cervical spine. Ann Surg. 1937;106:770-776.
-
(1937)
Ann Surg
, vol.106
, pp. 770-776
-
-
Gallie, W.E.1
-
3
-
-
0021367515
-
Posterior stabilization with an interlaminar clamp in cervical injuries: Technical note and review of the long term experience with the method
-
Holness RO, Huestis WS, Howes WJ, et al. Posterior stabilization with an interlaminar clamp in cervical injuries: technical note and review of the long term experience with the method. Neurosurgery. 1984;14:318-322.
-
(1984)
Neurosurgery
, vol.14
, pp. 318-322
-
-
Holness, R.O.1
Huestis, W.S.2
Howes, W.J.3
-
4
-
-
0023282239
-
Surgical stabilization of C1 and C2 fractures
-
Grob D, Magerl F. Surgical stabilization of C1 and C2 fractures. Orthopade. 1987;16:46-54.
-
(1987)
Orthopade
, vol.16
, pp. 46-54
-
-
Grob, D.1
Magerl, F.2
-
5
-
-
0035890208
-
Posterior C1-C2 fusion with polyaxial screw and rod fixation
-
Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976). 2001;26:2467-2471.
-
(2001)
Spine (Phila Pa 1976)
, vol.26
, pp. 2467-2471
-
-
Harms, J.1
Melcher, R.P.2
-
6
-
-
0030973318
-
Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique
-
Madawi AA, Casey AT, Solanki GA, et al. Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg. 1997;86:961-968.
-
(1997)
J Neurosurg
, vol.86
, pp. 961-968
-
-
Madawi, A.A.1
Casey, A.T.2
Solanki, G.A.3
-
7
-
-
0032143648
-
Anatomic study for ideal and safe posterior C1-C2 transarticular screw fixation
-
Jun BY. Anatomic study for ideal and safe posterior C1-C2 transarticular screw fixation. Spine (Phila Pa 1976). 1998;23:1703-1707.
-
(1998)
Spine (Phila Pa 1976)
, vol.23
, pp. 1703-1707
-
-
Jun, B.Y.1
-
8
-
-
33748079472
-
Does computer-assisted spine surgery reduce intraoperative radiation doses?
-
discussion 2028
-
Gebhard FT, Kraus MD, Schneider E, et al. Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine (Phila Pa 1976). 2006;31:2024-2027; discussion 2028.
-
(2006)
Spine (Phila Pa 1976)
, vol.31
, pp. 2024-2027
-
-
Gebhard, F.T.1
Kraus, M.D.2
Schneider, E.3
-
9
-
-
33846239956
-
Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries
-
Rajasekaran S, Vidyadhara S, Ramesh P, et al. Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine (Phila Pa 1976). 2007;32:E56-E64.
-
(2007)
Spine (Phila Pa 1976)
, vol.32
-
-
Rajasekaran, S.1
Vidyadhara, S.2
Ramesh, P.3
-
10
-
-
2342535057
-
Intraoperative Iso-C C-arm navigation in craniospinal surgery: The first 60 cases
-
discussion 1136-1137
-
Hott JS, Deshmukh VR, Klopfenstein JD, et al. Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurgery. 2004;54:1131-1136; discussion 1136-1137.
-
(2004)
Neurosurgery
, vol.54
, pp. 1131-1136
-
-
Hott, J.S.1
Deshmukh, V.R.2
Klopfenstein, J.D.3
-
11
-
-
0037234486
-
Navigated transoral approach to the cranial base and the craniocervical junction: Technical note
-
discussion 251
-
Vougioukas VI, Hubbe U, Schipper J, et al. Navigated transoral approach to the cranial base and the craniocervical junction: technical note. Neurosurgery. 2003;52:247-250; discussion 251.
-
(2003)
Neurosurgery
, vol.52
, pp. 247-250
-
-
Vougioukas, V.I.1
Hubbe, U.2
Schipper, J.3
-
12
-
-
4544380403
-
Fractures of the odontoid process of the axis. 1974
-
Anderson LD, D'Alonzo RT. Fractures of the odontoid process of the axis. 1974. J Bone Joint Surg Am. 2004;86-A:2081.
-
(2004)
J Bone Joint Surg Am
, vol.86 A
, pp. 2081
-
-
Anderson, L.D.1
D'Alonzo, R.T.2
-
13
-
-
45149130015
-
Odontoid screw placement using isocentric 3-dimensional C-arm fluoroscopy
-
Summers LE, Kouri JG, Yang M, et al. Odontoid screw placement using isocentric 3-dimensional C-arm fluoroscopy. J Spinal Disord Tech. 2008;21:45-48.
-
(2008)
J Spinal Disord Tech
, vol.21
, pp. 45-48
-
-
Summers, L.E.1
Kouri, J.G.2
Yang, M.3
-
14
-
-
70350721638
-
Posterior C1 lateral mass and C2 pedicle screw internal fixation for atlantoaxial instability
-
Xie Y, Li Z, Tang H, et al. Posterior C1 lateral mass and C2 pedicle screw internal fixation for atlantoaxial instability. J Clin Neurosci. 2009;16:1592-1594.
-
(2009)
J Clin Neurosci
, vol.16
, pp. 1592-1594
-
-
Xie, Y.1
Li, Z.2
Tang, H.3
-
15
-
-
78649284471
-
Comparison of the clinical accuracy of cervical (C2-C7) pedicle screw insertion assisted by fluoroscopy, computed tomography-based navigation, and intraoperative three-dimensional C-arm navigation
-
Liu YJ, Tian W, Liu B, et al. Comparison of the clinical accuracy of cervical (C2-C7) pedicle screw insertion assisted by fluoroscopy, computed tomography-based navigation, and intraoperative three-dimensional C-arm navigation. Chin Med J (Engl). 2010;123: 2995-2998.
-
(2010)
Chin Med J (Engl)
, vol.123
, pp. 2995-2998
-
-
Liu, Y.J.1
Tian, W.2
Liu, B.3
-
16
-
-
0028284239
-
Plate and screw fixation for atlanto-axial subluxation
-
Goel A, Laheri V. Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien). 1994;129:47-53.
-
(1994)
Acta Neurochir (Wien)
, vol.129
, pp. 47-53
-
-
Goel, A.1
Laheri, V.2
-
17
-
-
13444291294
-
Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: Transarticular screw fixation versus screw and rod fixation
-
discussion 151-159
-
Kuroki H, Rengachary SS, Goel VK, et al. Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: transarticular screw fixation versus screw and rod fixation. Neurosurgery. 2005;56:151-159; discussion 151-159.
-
(2005)
Neurosurgery
, vol.56
, pp. 151-159
-
-
Kuroki, H.1
Rengachary, S.S.2
Goel, V.K.3
-
18
-
-
35848942147
-
Atlantoaxial fusion: A biomechanical analysis of two C1-C2 fusion techniques
-
Claybrooks R, Kayanja M, Milks R, et al. Atlantoaxial fusion: a biomechanical analysis of two C1-C2 fusion techniques. Spine J. 2007;7:682-688.
-
(2007)
Spine J
, vol.7
, pp. 682-688
-
-
Claybrooks, R.1
Kayanja, M.2
Milks, R.3
-
19
-
-
68549122780
-
Undetected vertebral artery groove and foramen violations during C1 lateral mass and C2 pedicle screw placement
-
Yeom JS, Buchowski JM, Park KW, et al. Undetected vertebral artery groove and foramen violations during C1 lateral mass and C2 pedicle screw placement. Spine (Phila Pa 1976). 2008;33: E942-E949.
-
(2008)
Spine (Phila Pa 1976)
, vol.33
-
-
Yeom, J.S.1
Buchowski, J.M.2
Park, K.W.3
-
20
-
-
0142120120
-
Improved accuracy of computerassisted cervical pedicle screw insertion
-
Kotani Y, Abumi K, Ito M, et al. Improved accuracy of computerassisted cervical pedicle screw insertion. J Neurosurg. 2003;99:257-263.
-
(2003)
J Neurosurg
, vol.99
, pp. 257-263
-
-
Kotani, Y.1
Abumi, K.2
Ito, M.3
-
21
-
-
77954536009
-
Accuracy and complications of transpedicular C2 screw placement without the use of spinal navigation
-
Mueller CA, Roesseler L, Podlogar M, et al. Accuracy and complications of transpedicular C2 screw placement without the use of spinal navigation. Eur Spine J. 2010;19:809-814.
-
(2010)
Eur Spine J
, vol.19
, pp. 809-814
-
-
Mueller, C.A.1
Roesseler, L.2
Podlogar, M.3
-
22
-
-
77957782917
-
Long-term results of computer-assisted posterior occipitocervical reconstruction
-
Ogihara N, Takahashi J, Hirabayashi H, et al. Long-term results of computer-assisted posterior occipitocervical reconstruction. World Neurosurg. 2010;73:722-728.
-
(2010)
World Neurosurg
, vol.73
, pp. 722-728
-
-
Ogihara, N.1
Takahashi, J.2
Hirabayashi, H.3
-
23
-
-
58149291992
-
Comparison of radiation exposure in lumbar pedicle screw placement with fluoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging
-
Smith HE, Welsch MD, Sasso RC, et al. Comparison of radiation exposure in lumbar pedicle screw placement with fluoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging. J Spinal Cord Med. 2008;31:532-537.
-
(2008)
J Spinal Cord Med
, vol.31
, pp. 532-537
-
-
Smith, H.E.1
Welsch, M.D.2
Sasso, R.C.3
-
24
-
-
67649791453
-
Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure
-
Zwingmann J, Konrad G, Kotter E, et al. Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure. Clin Orthop Relat Res. 2009;467:1833-1838.
-
(2009)
Clin Orthop Relat Res
, vol.467
, pp. 1833-1838
-
-
Zwingmann, J.1
Konrad, G.2
Kotter, E.3
-
25
-
-
34147164687
-
Accuracy analysis of Iso-C3D versus fluoroscopy-based navigated retrograde drilling of osteochondral lesions: A pilot study
-
Citak M, Kendoff D, Kfuri M, et al. Accuracy analysis of Iso-C3D versus fluoroscopy-based navigated retrograde drilling of osteochondral lesions: a pilot study. J Bone Joint Surg Br. 2007;89: 323-326.
-
(2007)
J Bone Joint Surg Br
, vol.89
, pp. 323-326
-
-
Citak, M.1
Kendoff, D.2
Kfuri, M.3
-
26
-
-
33745048496
-
Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: Results of a controlled experimental investigation
-
Briem D, Linhart W, Lehmann W, et al. Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation. Eur Spine J. 2006;15:757-763.
-
(2006)
Eur Spine J
, vol.15
, pp. 757-763
-
-
Briem, D.1
Linhart, W.2
Lehmann, W.3
-
27
-
-
0142120104
-
Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placement: Technical note
-
Holly LT, Foley KT. Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placement: technical note. J Neurosurg. 2003;99(3 suppl):324-329.
-
(2003)
J Neurosurg
, vol.99
, Issue.3 SUPPL.
, pp. 324-329
-
-
Holly, L.T.1
Foley, K.T.2
-
28
-
-
2942567909
-
Computer aided tumor resection in the pelvis
-
Krettek C, Geerling J, Bastian L, et al. Computer aided tumor resection in the pelvis. Injury. 2004;35(suppl 1):79-83.
-
(2004)
Injury
, vol.35
, Issue.SUPPL. 1
, pp. 79-83
-
-
Krettek, C.1
Geerling, J.2
Bastian, L.3
-
29
-
-
84855169629
-
Anterior single screw fixation of odontoid fracture with intraoperative iso-C 3-dimensional imaging
-
Yang YL, Fu BS, Li RW, et al. Anterior single screw fixation of odontoid fracture with intraoperative iso-C 3-dimensional imaging. Eur Spine J. 2011;20:1899-1907.
-
(2011)
Eur Spine J
, vol.20
, pp. 1899-1907
-
-
Yang, Y.L.1
Fu, B.S.2
Li, R.W.3
|