-
1
-
-
84971343807
-
Standards of Medical Care in Diabetes - 2015
-
American Diabetes Association
-
American Diabetes Association Standards of Medical Care in Diabetes - 2015 Diabetes Care 38 Suppl. 1 2015 S8 S17
-
(2015)
Diabetes Care
, vol.38
, pp. S8-S17
-
-
-
3
-
-
65949125091
-
Stabilization of glucose in blood samples: Why it matters
-
[editorial]
-
D.E. Bruns, and W.C. Knowler Stabilization of glucose in blood samples: why it matters Clin. Chem. 55 2009 850 852 [editorial]
-
(2009)
Clin. Chem.
, vol.55
, pp. 850-852
-
-
Bruns, D.E.1
Knowler, W.C.2
-
4
-
-
17744400689
-
Optimization of prenalytical conditions and analysis of plasma glucose. 1. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitus
-
M. Stahl, L.H. Jørgensen, P. Hyltoft Peteresen, I. Brandslund, N. De Fine Olivarius, and K. Borch-Johnsen Optimization of prenalytical conditions and analysis of plasma glucose. 1. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitus Scand. J. Clin. Lab. Invest. 61 2001 169 180
-
(2001)
Scand. J. Clin. Lab. Invest.
, vol.61
, pp. 169-180
-
-
Stahl, M.1
Jørgensen, L.H.2
Hyltoft Peteresen, P.3
Brandslund, I.4
De Fine Olivarius, N.5
Borch-Johnsen, K.6
-
5
-
-
0016661815
-
Sodium iodoacetate as an antiglycolitic agent in blood samples
-
E. Marbach, M. McLean, M. Scharn, and T. Jones Sodium iodoacetate as an antiglycolitic agent in blood samples Clin. Chem. 21 1975 1810 1812
-
(1975)
Clin. Chem.
, vol.21
, pp. 1810-1812
-
-
Marbach, E.1
McLean, M.2
Scharn, M.3
Jones, T.4
-
7
-
-
0023819702
-
A new method of inhibiting glycolysis in blood samples
-
K. Uchida, R. Matuse, E. Toyoda, S. Okuda, and S. Tomita A new method of inhibiting glycolysis in blood samples Clin. Chim. Acta 172 1988 101 108
-
(1988)
Clin. Chim. Acta
, vol.172
, pp. 101-108
-
-
Uchida, K.1
Matuse, R.2
Toyoda, E.3
Okuda, S.4
Tomita, S.5
-
8
-
-
43449138195
-
Stabilization of glucose in blood specimens: Mechanism of delay in fluoride inhibition of glycolysis
-
[Letter]
-
L. Mikesh, and D.E. Bruns Stabilization of glucose in blood specimens: mechanism of delay in fluoride inhibition of glycolysis Clin. Chem. 54 2008 930 931 [Letter]
-
(2008)
Clin. Chem.
, vol.54
, pp. 930-931
-
-
Mikesh, L.1
Bruns, D.E.2
-
9
-
-
84880272024
-
Sodium fluoride: An ineffective inhibitor of glycolysis
-
R. Gambino Sodium fluoride: an ineffective inhibitor of glycolysis Ann. Clin. Biochem. 50 2013 3 5
-
(2013)
Ann. Clin. Biochem.
, vol.50
, pp. 3-5
-
-
Gambino, R.1
-
10
-
-
65949094591
-
Acidification of blood is superior to sodium fluoride alone as an inhibitor of glycolysis
-
R. Gambino, J. Piscitelli, T.A. Ackattupathil, J.L. Theriault, R.D. Andrin, M.L. Sanfilippo, and M. Etienne Acidification of blood is superior to sodium fluoride alone as an inhibitor of glycolysis Clin. Chem. 55 2009 1019 1021
-
(2009)
Clin. Chem.
, vol.55
, pp. 1019-1021
-
-
Gambino, R.1
Piscitelli, J.2
Ackattupathil, T.A.3
Theriault, J.L.4
Andrin, R.D.5
Sanfilippo, M.L.6
Etienne, M.7
-
11
-
-
79957759364
-
Executive summary: Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus
-
D.B. Sacks, M. Arnold, G.L. Bakris, D.E. Bruns, A.R. Horvath, A.R. Kirkman, A. Lernmark, B.E. Metzger, and D.M. Nathan Executive summary: guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus Clin. Chem. 57 2011 793 798
-
(2011)
Clin. Chem.
, vol.57
, pp. 793-798
-
-
Sacks, D.B.1
Arnold, M.2
Bakris, G.L.3
Bruns, D.E.4
Horvath, A.R.5
Kirkman, A.R.6
Lernmark, A.7
Metzger, B.E.8
Nathan, D.M.9
-
12
-
-
84964269848
-
Procedures for the collection of diagnostic blood specimens by venipuncture; Approved standard
-
CLSI sixth ed. Clinical and Laboratory Standards Institute Wayne, PA
-
CLSI Procedures for the collection of diagnostic blood specimens by venipuncture; approved standard CLSI Document GP41-A6 sixth ed. 2007 Clinical and Laboratory Standards Institute Wayne, PA
-
(2007)
CLSI Document GP41-A6
-
-
-
13
-
-
48649089665
-
Biological variation database, and quality specifications for imprecision, bias and total error (desirable and minimum)
-
J. Minchinela, C. Ricós, C. Perich, P. Fernández-Calle, V. Alvarez, M. Domenech, M. Simón, C. Biosca, B. Boned, F. Cava, J.V. García-Lario, and M.P. Fernández-Fernández Biological variation database, and quality specifications for imprecision, bias and total error (desirable and minimum) The 2014 Update 2014 Available at: (https://www.westgard.com/biodatabase1.htm)
-
(2014)
The 2014 Update
-
-
Minchinela, J.1
Ricós, C.2
Perich, C.3
Fernández-Calle, P.4
Alvarez, V.5
Domenech, M.6
Simón, M.7
Biosca, C.8
Boned, B.9
Cava, F.10
García-Lario, J.V.11
Fernández-Fernández, M.P.12
-
14
-
-
84903737429
-
Plasma glucose measurement in diabetes: Impact and implications in sample collection procedures with focus on the first hour after sample collection
-
H. Chan, H. Lunt, H. Thompson, H.F. Heenan, M.A. Frampton, and C.M. Florkowski Plasma glucose measurement in diabetes: impact and implications in sample collection procedures with focus on the first hour after sample collection Clin. Chem. Lab. Med. 52 2014 1061 1068
-
(2014)
Clin. Chem. Lab. Med.
, vol.52
, pp. 1061-1068
-
-
Chan, H.1
Lunt, H.2
Thompson, H.3
Heenan, H.F.4
Frampton, M.A.5
Florkowski, C.M.6
-
15
-
-
34447319106
-
Glycolysis inhibitors negatively bias blood glucose measurements: Potential impact on reported prevalence of diabetes mellitus
-
W.S. Waring, L.E. Evans, and C.T. Kirkpatrick Glycolysis inhibitors negatively bias blood glucose measurements: potential impact on reported prevalence of diabetes mellitus J. Clin. Pathol. 60 2007 820 823
-
(2007)
J. Clin. Pathol.
, vol.60
, pp. 820-823
-
-
Waring, W.S.1
Evans, L.E.2
Kirkpatrick, C.T.3
-
16
-
-
68149166768
-
Rapid separation is superior to fluoride for preventing in vitro reductions in measured blood glucose concentration
-
R.Z. Shi, E.S. Seeley, R. Bowen, and J.D. Faix Rapid separation is superior to fluoride for preventing in vitro reductions in measured blood glucose concentration J. Clin. Pathol. 62 2009 752 753
-
(2009)
J. Clin. Pathol.
, vol.62
, pp. 752-753
-
-
Shi, R.Z.1
Seeley, E.S.2
Bowen, R.3
Faix, J.D.4
-
17
-
-
84873327721
-
Impact of blood sample collection and processing methods on glucose levels in community outreach studies
-
M. Turchiano, C. Nguyen, A. Fierman, M. Lifshitz, and A. Convit Impact of blood sample collection and processing methods on glucose levels in community outreach studies J. Environ. Public Health 2013 2013 256151 10.1155/2013/256151
-
(2013)
J. Environ. Public Health
, vol.2013
, pp. 256151
-
-
Turchiano, M.1
Nguyen, C.2
Fierman, A.3
Lifshitz, M.4
Convit, A.5
-
18
-
-
84908127330
-
® RST blood collection tube for routine chemistry analytes: Clinical significance of differences and stability study
-
® RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study Biochem. Med. 24 2014 368 375
-
(2014)
Biochem. Med.
, vol.24
, pp. 368-375
-
-
Kocjancic, M.1
Cargonja, J.2
Delic-Knezevic, A.3
-
19
-
-
84924405779
-
It takes acid, rather than ice, to freeze glucose
-
MAR
-
Berg Van den, M.H.M. Thelen, S.W. Van Thiel, and K.J.M. Boonen It takes acid, rather than ice, to freeze glucose Sci. Rep. 5 Mar 2015 8875 10.1038/srep08875
-
(2015)
Sci. Rep.
, vol.5
, pp. 8875
-
-
Van Den, B.1
Thelen, M.H.M.2
Van Thiel, S.W.3
Boonen, K.J.M.4
-
20
-
-
0017199297
-
Stabilization of blood glucose by cooling with ice: An effective procedure for preservation of samples from adults and newborns
-
Y.L. Lin, C.H. Smith, and D.N. Diezler Stabilization of blood glucose by cooling with ice: an effective procedure for preservation of samples from adults and newborns Clin. Chem. 22 1976 2031 2033
-
(1976)
Clin. Chem.
, vol.22
, pp. 2031-2033
-
-
Lin, Y.L.1
Smith, C.H.2
Diezler, D.N.3
-
21
-
-
33644831902
-
Influence of hemolysis on routine clinical chemistry testing
-
G. Lippi, G.L. Salvagno, M. Montagnana, G. Brocco, and G.C. Guidi Influence of hemolysis on routine clinical chemistry testing Clin. Chem. Lab. Med. 44 2006 311 316
-
(2006)
Clin. Chem. Lab. Med.
, vol.44
, pp. 311-316
-
-
Lippi, G.1
Salvagno, G.L.2
Montagnana, M.3
Brocco, G.4
Guidi, G.C.5
-
22
-
-
84888112243
-
Stabilization of glucose in blood samples: Out with the old, in with the new
-
[editorial]
-
C. Gambino, and R.D.E. Bruns Stabilization of glucose in blood samples: out with the old, in with the new Clin. Chem. Lab. Med. 51 2013 1883 1885 [editorial]
-
(2013)
Clin. Chem. Lab. Med.
, vol.51
, pp. 1883-1885
-
-
Gambino, C.1
Bruns, R.D.E.2
-
23
-
-
84903711077
-
Stability of glucose in plasma with different anticoagulants
-
M. Fobker Stability of glucose in plasma with different anticoagulants Clin. Chem. Lab. Med. 52 2014 1057 1060
-
(2014)
Clin. Chem. Lab. Med.
, vol.52
, pp. 1057-1060
-
-
Fobker, M.1
-
24
-
-
84924755738
-
What is the most suitable blood collection tube for glucose estimation
-
G. Dimeski, K.S. Yow, and N.N. Brown What is the most suitable blood collection tube for glucose estimation Ann. Clin. Biochem. 52 2015 270 275
-
(2015)
Ann. Clin. Biochem.
, vol.52
, pp. 270-275
-
-
Dimeski, G.1
Yow, K.S.2
Brown, N.N.3
-
25
-
-
43249096940
-
Hyperglycemia and adverse pregnancy outcomes
-
HAPO Study Cooperative Research Group
-
HAPO Study Cooperative Research Group, B.E. Metzger, L.P. Lowe, A.R. Dayer, E.R. Trimble, U. Chaovarindr, D.R. Coustan, D.R. Hadden, D.R. McCance, M. Hod, H.D. McIntyre, J.J. Oats, B. Persson, M.S. Rogers, and D.A. Sacks Hyperglycemia and adverse pregnancy outcomes N. Engl. J. Med. 358 2008 1991 2002
-
(2008)
N. Engl. J. Med.
, vol.358
, pp. 1991-2002
-
-
Metzger, B.E.1
Lowe, L.P.2
Dayer, A.R.3
Trimble, E.R.4
Chaovarindr, U.5
Coustan, D.R.6
Hadden, D.R.7
McCance, D.R.8
Hod, M.9
McIntyre, H.D.10
Oats, J.J.11
Persson, B.12
Rogers, M.S.13
Sacks, D.A.14
-
26
-
-
84900310157
-
The shift from fluoride/oxalate to acid citrate/fluoride blood collection tubes for glucose testing - The impact upon patients results
-
M. Norman, and I. Jones The shift from fluoride/oxalate to acid citrate/fluoride blood collection tubes for glucose testing - the impact upon patients results Clin. Biochem. 47 2014 683 685
-
(2014)
Clin. Biochem.
, vol.47
, pp. 683-685
-
-
Norman, M.1
Jones, I.2
-
27
-
-
84900312246
-
Increased plasma glucose levels after change of recommendation from NaF to citrate blood collection tubes
-
P. Ridefelt, T. Akerfeldt, and J. Helmersson-Karlqvist Increased plasma glucose levels after change of recommendation from NaF to citrate blood collection tubes Clin. Biochem. 47 2014 625 628
-
(2014)
Clin. Biochem.
, vol.47
, pp. 625-628
-
-
Ridefelt, P.1
Akerfeldt, T.2
Helmersson-Karlqvist, J.3
|