메뉴 건너뛰기




Volumn 47, Issue 7-8, 2014, Pages 625-628

Increased plasma glucose levels after change of recommendation from NaF to citrate blood collection tubes

Author keywords

Blood collection tube; Glucose; Plasma; Preanalytical process; Sample stability

Indexed keywords

CITRIC ACID; GLUCOSE; HEMOGLOBIN A1C; SODIUM FLUORIDE; GLUCOSE BLOOD LEVEL;

EID: 84900312246     PISSN: 00099120     EISSN: 18732933     Source Type: Journal    
DOI: 10.1016/j.clinbiochem.2014.02.022     Document Type: Article
Times cited : (23)

References (17)
  • 1
    • 79957715132 scopus 로고    scopus 로고
    • Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus
    • Sacks D.B., Arnold M., Bakris G.L., Bruns D.E., Horvath A.R., Kirkman M.S., et al. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem 2011, 57:e1-e47.
    • (2011) Clin Chem , vol.57
    • Sacks, D.B.1    Arnold, M.2    Bakris, G.L.3    Bruns, D.E.4    Horvath, A.R.5    Kirkman, M.S.6
  • 2
    • 80051981694 scopus 로고    scopus 로고
    • Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus
    • Sacks D.B., Arnold M., Bakris G.L., Bruns D.E., Horvath A.R., Kirkman M.S., et al. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Diabetes Care 2011, 34:e61-e99.
    • (2011) Diabetes Care , vol.34
    • Sacks, D.B.1    Arnold, M.2    Bakris, G.L.3    Bruns, D.E.4    Horvath, A.R.5    Kirkman, M.S.6
  • 4
    • 0024596090 scopus 로고
    • Effectiveness of sodium fluoride as a preservative of glucose in blood
    • Chan A.Y., Swaminathan R., Cockram C.S. Effectiveness of sodium fluoride as a preservative of glucose in blood. Clin Chem 1989, 35:315-317.
    • (1989) Clin Chem , vol.35 , pp. 315-317
    • Chan, A.Y.1    Swaminathan, R.2    Cockram, C.S.3
  • 5
    • 43449138195 scopus 로고    scopus 로고
    • Stabilization of glucose in blood specimens: mechanism of delay in fluoride inhibition of glycolysis
    • Mikesh L.M., Bruns D.E. Stabilization of glucose in blood specimens: mechanism of delay in fluoride inhibition of glycolysis. Clin Chem 2008, 54:930-932.
    • (2008) Clin Chem , vol.54 , pp. 930-932
    • Mikesh, L.M.1    Bruns, D.E.2
  • 9
    • 78651276631 scopus 로고    scopus 로고
    • Diagnosis and classification of diabetes mellitus
    • American Diabetes Association
    • American Diabetes Association Diagnosis and classification of diabetes mellitus. Diabetes Care 2011, 34:S62-S69.
    • (2011) Diabetes Care , vol.34
  • 10
    • 9144234059 scopus 로고    scopus 로고
    • IFCC Working Group on HbA1c Standardization. IFCC reference system for measurements of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study
    • [C:\pubmed\14709644]
    • Hoelzel W., Weykamp C., Jeppsson J.O., Miedema K., Barr J.R., Goodall I., et al. IFCC Working Group on HbA1c Standardization. IFCC reference system for measurements of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study. Clin Chem 2004, 50:166-174. [C:\pubmed\14709644].
    • (2004) Clin Chem , vol.50 , pp. 166-174
    • Hoelzel, W.1    Weykamp, C.2    Jeppsson, J.O.3    Miedema, K.4    Barr, J.R.5    Goodall, I.6
  • 11
    • 84900304948 scopus 로고    scopus 로고
    • Available at: URL:, [accessed on Feb 20, 2014] EQUALIS
    • EQUALIS Available at: URL:, [accessed on Feb 20, 2014]. http://www.equalis.se/en/start.aspx.
  • 12
    • 65949125091 scopus 로고    scopus 로고
    • Stabilization of glucose in blood samples: why it matters
    • Bruns D.E., Knowler W.C. Stabilization of glucose in blood samples: why it matters. Clin Chem 2009, 55:850-852.
    • (2009) Clin Chem , vol.55 , pp. 850-852
    • Bruns, D.E.1    Knowler, W.C.2
  • 14
    • 84891794711 scopus 로고    scopus 로고
    • Diagnosis of gestational diabetes mellitus: it is time for international consensus
    • Sacks D.B. Diagnosis of gestational diabetes mellitus: it is time for international consensus. Clin Chem 2014, 60:141-143.
    • (2014) Clin Chem , vol.60 , pp. 141-143
    • Sacks, D.B.1
  • 15
    • 84873731597 scopus 로고    scopus 로고
    • A comparison of glucose concentration in paired specimens collected in serum separator and fluoride/potassium oxalate blood collection tubes under survey 'field' conditions
    • Fernandez L., Jee P., Klein M.J., Fischer P., Perkins S.L., Brooks S.P. A comparison of glucose concentration in paired specimens collected in serum separator and fluoride/potassium oxalate blood collection tubes under survey 'field' conditions. Clin Biochem 2013, 46:285-288.
    • (2013) Clin Biochem , vol.46 , pp. 285-288
    • Fernandez, L.1    Jee, P.2    Klein, M.J.3    Fischer, P.4    Perkins, S.L.5    Brooks, S.P.6
  • 16
    • 84888112243 scopus 로고    scopus 로고
    • Stabilization of glucose in blood samples: out with the old, in with the new
    • Gambino R., Bruns D.E. Stabilization of glucose in blood samples: out with the old, in with the new. Clin Chem Lab Med 2013, 51:1883-1885.
    • (2013) Clin Chem Lab Med , vol.51 , pp. 1883-1885
    • Gambino, R.1    Bruns, D.E.2
  • 17
    • 84872038947 scopus 로고    scopus 로고
    • It's time for a better blood collection tube to improve the reliability of glucose results
    • Peake M.J., Bruns D.E., Sacks D.B., Horvath A.R. It's time for a better blood collection tube to improve the reliability of glucose results. Diabetes Care 2013, 36:e2.
    • (2013) Diabetes Care , vol.36
    • Peake, M.J.1    Bruns, D.E.2    Sacks, D.B.3    Horvath, A.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.