메뉴 건너뛰기




Volumn 47, Issue 7-8, 2014, Pages 683-685

The shift from fluoride/oxalate to acid citrate/fluoride blood collection tubes for glucose testing - The impact upon patient results

Author keywords

Antiglycolytic additives; Diagnostic errors; Glucose; Preanalytical conditions

Indexed keywords

CITRIC ACID; EDETIC ACID; FLUORIDE; GLUCOSE; OXALIC ACID; FLUOROPHOSPHATE; GLUCOSE BLOOD LEVEL; OXALIC ACID DERIVATIVE; PHOSPHATE;

EID: 84900310157     PISSN: 00099120     EISSN: 18732933     Source Type: Journal    
DOI: 10.1016/j.clinbiochem.2014.01.011     Document Type: Article
Times cited : (21)

References (9)
  • 1
    • 0024596090 scopus 로고
    • Effectiveness of sodium fluoride as a preservative of glucose in blood
    • Chan A.Y., Swaminathan R., Cockram C.S. Effectiveness of sodium fluoride as a preservative of glucose in blood. Clin Chem 1989, 35:315-317.
    • (1989) Clin Chem , vol.35 , pp. 315-317
    • Chan, A.Y.1    Swaminathan, R.2    Cockram, C.S.3
  • 2
    • 84880272024 scopus 로고    scopus 로고
    • Sodium fluoride: an ineffective inhibitor of glycolysis
    • Gambino R. Sodium fluoride: an ineffective inhibitor of glycolysis. Ann Clin Biochem 2013, 50:3-5.
    • (2013) Ann Clin Biochem , vol.50 , pp. 3-5
    • Gambino, R.1
  • 4
    • 79957759364 scopus 로고    scopus 로고
    • Executive summary: guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus
    • Sacks D.B., Arnold M., Bakris G.L., Bruns D.E., Horvath A.R., Kirkman M.S., et al. Executive summary: guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem 2011, 57:793-798.
    • (2011) Clin Chem , vol.57 , pp. 793-798
    • Sacks, D.B.1    Arnold, M.2    Bakris, G.L.3    Bruns, D.E.4    Horvath, A.R.5    Kirkman, M.S.6
  • 5
    • 84872038947 scopus 로고    scopus 로고
    • It's time for a better blood collection tube to improve the reliability of glucose results
    • Peake M.J., Bruns D.E., Sacks D.B., Horvath A.R. It's time for a better blood collection tube to improve the reliability of glucose results. Diabetes Care 2013, 36:e2.
    • (2013) Diabetes Care , vol.36
    • Peake, M.J.1    Bruns, D.E.2    Sacks, D.B.3    Horvath, A.R.4
  • 6
    • 53549109464 scopus 로고    scopus 로고
    • Use of routine clinical laboratory data to define reference intervals
    • Shine B. Use of routine clinical laboratory data to define reference intervals. Ann Clin Biochem 2008, 45:467-475.
    • (2008) Ann Clin Biochem , vol.45 , pp. 467-475
    • Shine, B.1
  • 7
    • 84873615005 scopus 로고    scopus 로고
    • Are fluoride-containing blood tubes still needed for glucose testing?
    • Bruns D.E. Are fluoride-containing blood tubes still needed for glucose testing?. Clin Biochem 2013, 46:289-290.
    • (2013) Clin Biochem , vol.46 , pp. 289-290
    • Bruns, D.E.1
  • 8
    • 65949125091 scopus 로고    scopus 로고
    • Stabilization of glucose in blood samples: why it matters
    • Bruns D.E., Knowler W.C. Stabilization of glucose in blood samples: why it matters. Clin Chem 2009, 55:850-852.
    • (2009) Clin Chem , vol.55 , pp. 850-852
    • Bruns, D.E.1    Knowler, W.C.2
  • 9
    • 84888112243 scopus 로고    scopus 로고
    • Stabilization of glucose in blood samples: out with the old, in with the new
    • Gambino R., Bruns D.E. Stabilization of glucose in blood samples: out with the old, in with the new. Clin Chem Lab Med 2013, 1-3.
    • (2013) Clin Chem Lab Med , pp. 1-3
    • Gambino, R.1    Bruns, D.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.