메뉴 건너뛰기




Volumn 235, Issue , 2015, Pages 151-157

Arrayed-type touch sensor using micro liquid metal droplets with large dynamic range and high sensitivity

Author keywords

Capacitive touch sensor; High sensitivity; Large dynamic range; Liquid metal droplet; Truncated pyramid shaped PDMS chamber

Indexed keywords

CAPACITANCE; CONTACT SENSORS; DROPS; ELECTRODES; FABRICATION; IMAGE RESOLUTION; LIQUID METALS; LIQUIDS; MICROCHANNELS; OXIDE FILMS; POLYDIMETHYLSILOXANE; SILICONES;

EID: 84944395764     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2015.09.044     Document Type: Article
Times cited : (26)

References (21)
  • 2
    • 0042431781 scopus 로고    scopus 로고
    • Tactile sensing technology for minimal access surgery - A review
    • M.E.H. Eltaib, and J.R. Hewit Tactile sensing technology for minimal access surgery - a review Mechatronics 13 2003 1163 1177
    • (2003) Mechatronics , vol.13 , pp. 1163-1177
    • Eltaib, M.E.H.1    Hewit, J.R.2
  • 3
    • 84860367849 scopus 로고    scopus 로고
    • A review of tactile sensing technologies with applications in biomedical engineering
    • M.I. Tiwana, S.J. Redmond, and N.H. Lovell A review of tactile sensing technologies with applications in biomedical engineering Sens. Actuators A: Phys. 179 2012 17 31
    • (2012) Sens. Actuators A: Phys. , vol.179 , pp. 17-31
    • Tiwana, M.I.1    Redmond, S.J.2    Lovell, N.H.3
  • 5
    • 33749654379 scopus 로고    scopus 로고
    • Human tactile perception as a standard for artificial tactile sensing - A review
    • J. Dargahi Human tactile perception as a standard for artificial tactile sensing - a review Int. J. Med. Robot. Comput. Assist. Surg. 1 2004 23 35
    • (2004) Int. J. Med. Robot. Comput. Assist. Surg. , vol.1 , pp. 23-35
    • Dargahi, J.1
  • 7
    • 79952646836 scopus 로고    scopus 로고
    • Real-time measurement of the three-axis contact force distribution using a flexible capacitive polymer tactile sensor
    • H.-K. Lee, J. Chung, S.-I. Chang, and E. Yoon Real-time measurement of the three-axis contact force distribution using a flexible capacitive polymer tactile sensor J. Micromech. Microeng. 21 2011 035010
    • (2011) J. Micromech. Microeng. , vol.21 , pp. 035010
    • Lee, H.-K.1    Chung, J.2    Chang, S.-I.3    Yoon, E.4
  • 8
    • 84871048971 scopus 로고    scopus 로고
    • A polymer-based capacitive sensing array for normal and shear force measurement
    • M.Y. Cheng, C.L. Lin, Y.T. Lai, and Y.J. Yang A polymer-based capacitive sensing array for normal and shear force measurement Sensors 10 2010 10211 10225
    • (2010) Sensors , vol.10 , pp. 10211-10225
    • Cheng, M.Y.1    Lin, C.L.2    Lai, Y.T.3    Yang, Y.J.4
  • 9
    • 84878127076 scopus 로고    scopus 로고
    • Polymer-based flexible capacitive sensor for three-axial force measurements
    • J.A. Dobrzynska, and M.A.M. Gijs Polymer-based flexible capacitive sensor for three-axial force measurements J. Micromech. Microeng. 23 2013 015009
    • (2013) J. Micromech. Microeng. , vol.23 , pp. 015009
    • Dobrzynska, J.A.1    Gijs, M.A.M.2
  • 10
    • 49149093632 scopus 로고    scopus 로고
    • Normal and shear force measurement using a flexible polymer tactile sensor with embedded multiple capacitors
    • H.-K. Lee, J. Chung, S.-I. Chang, and E. Yoon Normal and shear force measurement using a flexible polymer tactile sensor with embedded multiple capacitors J. Microelectromech. Syst. 17 2008 934 942
    • (2008) J. Microelectromech. Syst. , vol.17 , pp. 934-942
    • Lee, H.-K.1    Chung, J.2    Chang, S.-I.3    Yoon, E.4
  • 11
    • 84900018815 scopus 로고    scopus 로고
    • Flexible three-axial force sensor for soft and highly sensitive artificial touch
    • 14
    • L. Viry, A. Levi, M. Totaro, A. Mondini, V. Mattoli, B. Mazzolai, and et al. Flexible three-axial force sensor for soft and highly sensitive artificial touch Adv. Mat. 26 2014 2659 2664 14
    • (2014) Adv. Mat. , vol.26 , pp. 2659-2664
    • Viry, L.1    Levi, A.2    Totaro, M.3    Mondini, A.4    Mattoli, V.5    Mazzolai, B.6
  • 12
    • 84860383259 scopus 로고    scopus 로고
    • Flexible microfluidic normal force sensor skin for tactile feedback
    • R.D. Ponce Wong, J.D. Posner, and V.J. Santos Flexible microfluidic normal force sensor skin for tactile feedback Sens. Actuators A: Phys. 179 2012 62 69
    • (2012) Sens. Actuators A: Phys. , vol.179 , pp. 62-69
    • Ponce Wong, R.D.1    Posner, J.D.2    Santos, V.J.3
  • 14
    • 77949570747 scopus 로고    scopus 로고
    • Capacitive pressure sensor with very large dynamic range
    • E.G. Bakhoum Capacitive pressure sensor with very large dynamic range IEEE Trans. Compon. Packag. Technol. 33 2010 79 83
    • (2010) IEEE Trans. Compon. Packag. Technol. , vol.33 , pp. 79-83
    • Bakhoum, E.G.1
  • 15
    • 0036853462 scopus 로고    scopus 로고
    • A bulk microfabricated multi-axis capacitive cellular force sensor using transverse comb drives
    • Y. Sun, B.J. Nelson, D.P. Potasek, and E. Enikov A bulk microfabricated multi-axis capacitive cellular force sensor using transverse comb drives J. Micromech. Microeng. 12 2002 832
    • (2002) J. Micromech. Microeng. , vol.12 , pp. 832
    • Sun, Y.1    Nelson, B.J.2    Potasek, D.P.3    Enikov, E.4
  • 16
    • 0036544175 scopus 로고    scopus 로고
    • A micromechanical switch with electrostatically driven liquid-metal droplet
    • J. Kim, W. Shen, L. Latorre, and C.-J. Kim A micromechanical switch with electrostatically driven liquid-metal droplet Sens. Actuators A: Phys. 97-98 2002 672 679
    • (2002) Sens. Actuators A: Phys. , vol.97-98 , pp. 672-679
    • Kim, J.1    Shen, W.2    Latorre, L.3    Kim, C.-J.4
  • 17
    • 79952533429 scopus 로고    scopus 로고
    • Development and characterization of a novel configurable MEMS inertial switch using a microscale liquid-metal droplet in a microstructured channel
    • K. Yoo, U. Park, and J. Kim Development and characterization of a novel configurable MEMS inertial switch using a microscale liquid-metal droplet in a microstructured channel Sens. Actuators A: Phys. 166 2011 234 240
    • (2011) Sens. Actuators A: Phys. , vol.166 , pp. 234-240
    • Yoo, K.1    Park, U.2    Kim, J.3
  • 18
    • 84878148931 scopus 로고    scopus 로고
    • Pneumatic RF MEMS switch using a liquid metal droplet
    • S. Baek, U. Park, I.H. Choi, and J. Kim Pneumatic RF MEMS switch using a liquid metal droplet J. Micromech. Microeng. 23 2013 055006
    • (2013) J. Micromech. Microeng. , vol.23 , pp. 055006
    • Baek, S.1    Park, U.2    Choi, I.H.3    Kim, J.4
  • 19
    • 40949155859 scopus 로고    scopus 로고
    • Micro-impedance inclinometer with wide-angle measuring capability and no damping effect
    • C.H. Lin, and S.M. Kuo Micro-impedance inclinometer with wide-angle measuring capability and no damping effect Sens. Actuators A: Phys. 143 2008 113 119
    • (2008) Sens. Actuators A: Phys. , vol.143 , pp. 113-119
    • Lin, C.H.1    Kuo, S.M.2
  • 20
    • 0034333620 scopus 로고    scopus 로고
    • Microfabricated elastomeric stencils for micropatterning cell cultures
    • A. Folch, B.H. Jo, O. Hurtado, D.J. Beebe, and M. Toner Microfabricated elastomeric stencils for micropatterning cell cultures J. Biomed. Mater. Res. 52 2000 346 353
    • (2000) J. Biomed. Mater. Res. , vol.52 , pp. 346-353
    • Folch, A.1    Jo, B.H.2    Hurtado, O.3    Beebe, D.J.4    Toner, M.5
  • 21
    • 33845517787 scopus 로고    scopus 로고
    • A flexible polymer tactile sensor: Fabrication and modular expandability for large area deployment
    • H.-K. Lee, S.-I. Chang, and E. Yoon A flexible polymer tactile sensor: fabrication and modular expandability for large area deployment J. Microelectromech. Syst. 15 2006 1681 1686
    • (2006) J. Microelectromech. Syst. , vol.15 , pp. 1681-1686
    • Lee, H.-K.1    Chang, S.-I.2    Yoon, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.