메뉴 건너뛰기




Volumn 17, Issue 5, 2015, Pages 792-796

Management of end-stage erectile dysfunction and stress urinary incontinence after radical prostatectomy by simultaneous dual implantation using a single trans-scrotal incision: Surgical technique and outcomes

Author keywords

[No Author keywords available]

Indexed keywords

AMOXICILLIN; CLAVULANIC ACID; GENTAMICIN; LEVOFLOXACIN;

EID: 84940758799     PISSN: 1008682X     EISSN: 17457262     Source Type: Journal    
DOI: 10.4103/1008-682X.143757     Document Type: Article
Times cited : (17)

References (29)
  • 1
    • 84860266865 scopus 로고    scopus 로고
    • International variation in prostate cancer incidence and mortality rates
    • Center MM, Jemal A, Lortet-Tieulent J, Ward E, Ferlay J, et al. International variation in prostate cancer incidence and mortality rates. Eur Urol 2012; 61: 1079-92.
    • (2012) Eur Urol , vol.61 , pp. 1079-1092
    • Center, M.M.1    Jemal, A.2    Lortet-Tieulent, J.3    Ward, E.4    Ferlay, J.5
  • 2
    • 84864486220 scopus 로고    scopus 로고
    • Systematic review and meta-analysis of studies reporting urinary continence recovery after robot-assisted radical prostatectomy
    • Ficarra V, Novara G, Rosen RC, Artibani W, Carroll PR, et al. Systematic review and meta-analysis of studies reporting urinary continence recovery after robot-assisted radical prostatectomy. Eur Urol 2012; 62: 405-17.
    • (2012) Eur Urol , vol.62 , pp. 405-417
    • Ficarra, V.1    Novara, G.2    Rosen, R.C.3    Artibani, W.4    Carroll, P.R.5
  • 3
    • 84864448127 scopus 로고    scopus 로고
    • Systematic review and meta-analysis of studies reporting potency rates after robot-assisted radical prostatectomy
    • Ficarra V, Novara G, Ahlering TE, Costello A, Eastham JA, et al. Systematic review and meta-analysis of studies reporting potency rates after robot-assisted radical prostatectomy. Eur Urol 2012; 62: 418-30.
    • (2012) Eur Urol , vol.62 , pp. 418-430
    • Ficarra, V.1    Novara, G.2    Ahlering, T.E.3    Costello, A.4    Eastham, J.A.5
  • 4
    • 0034685027 scopus 로고    scopus 로고
    • Urinary and sexual function after radical prostatectomy for clinically localized prostate cancer: The prostate cancer outcomes study
    • Stanford JL, Feng Z, Hamilton AS, Gilliland FD, Stephenson RA, et al. Urinary and sexual function after radical prostatectomy for clinically localized prostate cancer: the prostate cancer outcomes study. JAMA 2000; 283: 354-60.
    • (2000) JAMA , vol.283 , pp. 354-360
    • Stanford, J.L.1    Feng, Z.2    Hamilton, A.S.3    Gilliland, F.D.4    Stephenson, R.A.5
  • 5
    • 0015649828 scopus 로고
    • Management of erectile impotence Use of implantable inflatable prosthesis
    • Scott FB, Bradley WE, Timm GW. Management of erectile impotence. Use of implantable inflatable prosthesis. Urology 1973; 2: 80-2.
    • (1973) Urology , vol.2 , pp. 80-82
    • Scott, F.B.1    Bradley, W.E.2    Timm, G.W.3
  • 6
    • 84868534860 scopus 로고    scopus 로고
    • EAU guidelines on surgical treatment of urinary incontinence
    • Lucas MG, Bosch RJ, Burkhard FC, Cruz F, Madden TB, et al. EAU guidelines on surgical treatment of urinary incontinence. Eur Urol 2012; 62: 1118-29.
    • (2012) Eur Urol , vol.62 , pp. 1118-1129
    • Lucas, M.G.1    Bosch, R.J.2    Burkhard, F.C.3    Cruz, F.4    Madden, T.B.5
  • 7
    • 0037213864 scopus 로고    scopus 로고
    • New surgical technique for sphincter urinary control system using upper transverse scrotal incision
    • Wilson S, Delk J 2 nd, Henry GD, Siegel AL. New surgical technique for sphincter urinary control system using upper transverse scrotal incision. J Urol 2003; 169: 261-4.
    • (2003) J Urol , vol.169 , pp. 261-264
    • Wilson, S.1    Delk, I.I.J.2    Henry, G.D.3    Siegel, A.L.4
  • 8
    • 77957340854 scopus 로고    scopus 로고
    • New enhancements of the scrotal one-incision technique for placement of artificial urinary sphincter allow proximal cuff placement
    • Wilson SK, Aliotta PJ, Salem EA, Mulcahy JJ. New enhancements of the scrotal one-incision technique for placement of artificial urinary sphincter allow proximal cuff placement. J Sex Med 2010; 7: 3510-5.
    • (2010) J Sex Med , vol.7 , pp. 3510-3515
    • Wilson, S.K.1    Aliotta, P.J.2    Salem, E.A.3    Mulcahy, J.J.4
  • 9
    • 84868208748 scopus 로고    scopus 로고
    • Surgical implantation of artificial urinary device and penile prosthesis through trans-scrotal incision for postprostatectomy urinary incontinence and erectile dysfunction: Synchronous or delayed procedure?
    • Rolle L, Ceruti C, Sedigh O, Timpano M, Destefanis P, et al. Surgical implantation of artificial urinary device and penile prosthesis through trans-scrotal incision for postprostatectomy urinary incontinence and erectile dysfunction: synchronous or delayed procedure? Urology 2012; 80: 1046-50.
    • (2012) Urology , vol.80 , pp. 1046-1050
    • Rolle, L.1    Ceruti, C.2    Sedigh, O.3    Timpano, M.4    Destefanis, P.5
  • 10
    • 84872170576 scopus 로고    scopus 로고
    • Simultaneous penile prosthesis and male sling/artificial urinary sphincter
    • Lee D, Romero C, Alba F, Westney OL, Wang R. Simultaneous penile prosthesis and male sling/artificial urinary sphincter. Asian J Androl 2013; 15: 10-5.
    • (2013) Asian J Androl , vol.15 , pp. 10-15
    • Lee, D.1    Romero, C.2    Alba, F.3    Westney, O.L.4    Wang, R.5
  • 11
    • 84873058504 scopus 로고    scopus 로고
    • High submuscular placement of urologic prosthetic balloons and reservoirs via transscrotal approach
    • Morey AF, Cefalu CA, Hudak SJ. High submuscular placement of urologic prosthetic balloons and reservoirs via transscrotal approach. J Sex Med 2013; 10: 603-10.
    • (2013) J Sex Med , vol.10 , pp. 603-610
    • Morey, A.F.1    Cefalu, C.A.2    Hudak, S.J.3
  • 13
    • 0142215451 scopus 로고    scopus 로고
    • Surgical approaches for penile prosthesis implantation: Penoscrotal vs infrapubic
    • Montague DK, Angermeir KW. Surgical approaches for penile prosthesis implantation: penoscrotal vs infrapubic. Int J Impot Res 2003; 15 Suppl 5: S134-5.
    • (2003) Int J Impot Res , vol.15 , pp. S134-S135
    • Montague, D.K.1    Angermeir, K.W.2
  • 14
    • 75849147892 scopus 로고    scopus 로고
    • Inflatable penile prosthesis implantation without corporeal dilation: A cavernous tissue sparing technique
    • Moncada I, Martínez-Salamanca JI, Jara J, Cabello R, Moralejo M, et al. Inflatable penile prosthesis implantation without corporeal dilation: a cavernous tissue sparing technique. J Urol 2010; 183: 1123-6.
    • (2010) J Urol , vol.183 , pp. 1123-1126
    • Moncada, I.1    Martínez-Salamanca, J.I.2    Jara, J.3    Cabello, R.4    Moralejo, M.5
  • 15
    • 3042757797 scopus 로고    scopus 로고
    • ICIQ: A brief and robust measure for evaluating the symptoms and impact of urinary incontinence
    • Avery K, Donovan J, Peters TJ, Shaw C, Gotoh M, et al. ICIQ: a brief and robust measure for evaluating the symptoms and impact of urinary incontinence. Neurourol Urodyn 2004; 23: 322-30.
    • (2004) Neurourol Urodyn , vol.23 , pp. 322-330
    • Avery, K.1    Donovan, J.2    Peters, T.J.3    Shaw, C.4    Gotoh, M.5
  • 16
    • 0032929493 scopus 로고    scopus 로고
    • Quality of life of women with urinary incontinence: Further development of the incontinence quality of life instrument (I-QOL)
    • Patrick DL, Martin ML, Bushnell DM, Yalcin I, Wagner TH, et al. Quality of life of women with urinary incontinence: further development of the incontinence quality of life instrument (I-QOL). Urology 1999; 53: 71-6.
    • (1999) Urology , vol.53 , pp. 71-76
    • Patrick, D.L.1    Martin, M.L.2    Bushnell, D.M.3    Yalcin, I.4    Wagner, T.H.5
  • 17
    • 22144498081 scopus 로고    scopus 로고
    • The current role of the artificial urinary sphincter for the treatment of urinary incontinence
    • Hussain M, Greenwell TJ, Venn SN, Mundy AR. The current role of the artificial urinary sphincter for the treatment of urinary incontinence. J Urol 2005; 174: 418-24.
    • (2005) J Urol , vol.174 , pp. 418-424
    • Hussain, M.1    Greenwell, T.J.2    Venn, S.N.3    Mundy, A.R.4
  • 18
    • 0033373460 scopus 로고    scopus 로고
    • Development and evaluation of an abridged, 5-item version of the International Index of Erectile Function (IIEF-5) as a diagnostic tool for erectile dysfunction
    • Rosen RC, Cappelleri JC, Smith MD, Lipsky J, Peña BM. Development and evaluation of an abridged, 5-item version of the International Index of Erectile Function (IIEF-5) as a diagnostic tool for erectile dysfunction. Int J Impot Res 1999; 11: 319-26.
    • (1999) Int J Impot Res , vol.11 , pp. 319-326
    • Rosen, R.C.1    Cappelleri, J.C.2    Smith, M.D.3    Lipsky, J.4    Peña, B.M.5
  • 19
    • 77953948992 scopus 로고    scopus 로고
    • Guidelines on male sexual dysfunction: Erectile dysfunction and premature ejaculation
    • Hatzimouratidis K, Amar E, Eardley I, Giuliano F, Hatzichristou D, et al. Guidelines on male sexual dysfunction: erectile dysfunction and premature ejaculation. Eur Urol 2010; 57: 804-14.
    • (2010) Eur Urol , vol.57 , pp. 804-814
    • Hatzimouratidis, K.1    Amar, E.2    Eardley, I.3    Giuliano, F.4    Hatzichristou, D.5
  • 21
    • 33646356201 scopus 로고    scopus 로고
    • Synchronous prosthetic implantation through a transscrotal incision: An outcome analysis
    • Kendirci M, Gupta S, Shaw K, Morey A, Jones L, et al. Synchronous prosthetic implantation through a transscrotal incision: an outcome analysis. J Urol 2006; 175: 2218-22.
    • (2006) J Urol , vol.175 , pp. 2218-2222
    • Kendirci, M.1    Gupta, S.2    Shaw, K.3    Morey, A.4    Jones, L.5
  • 22
    • 84888637261 scopus 로고    scopus 로고
    • Combined inflatable penile prosthesis-artificial urinary sphincter implantation: No increased risk of adverse events compared to single or staged device implantation
    • Segal RL, Cabrini MR, Harris ED, Mostwin JL, Bivalacqua TJ, et al. Combined inflatable penile prosthesis-artificial urinary sphincter implantation: no increased risk of adverse events compared to single or staged device implantation. J Urol 2013; 190: 2183-8.
    • (2013) J Urol , vol.190 , pp. 2183-2188
    • Segal, R.L.1    Cabrini, M.R.2    Harris, E.D.3    Mostwin, J.L.4    Bivalacqua, T.J.5
  • 23
    • 84855647094 scopus 로고    scopus 로고
    • Dual implantation of artificial urinary sphincter and inflatable penile prostheses for concurrent male urinary incontinence and erectile dysfunction
    • Al-Shaiji TF. Dual implantation of artificial urinary sphincter and inflatable penile prostheses for concurrent male urinary incontinence and erectile dysfunction. Adv Urol 2011; 2011: 178312.
    • (2011) Adv Urol , vol.2011 , pp. 178312
    • Al-Shaiji, T.F.1
  • 24
    • 84860311463 scopus 로고    scopus 로고
    • Asynchronous implantation of a penile pros thesis (AMS 700) in patients with an artificial urinary sphincter (AMS 800): What functional outcomes can we expect from the AMS 1500?
    • Alechinsky L, Phé V, Yates DR, Bourgade V, Parra J, et al. Asynchronous implantation of a penile prosthesis (AMS 700) in patients with an artificial urinary sphincter (AMS 800): what functional outcomes can we expect from the AMS 1500?. Prog Urol 2010; 22: 354-9.
    • (2010) Prog Urol , vol.22 , pp. 354-359
    • Alechinsky, L.1    Phé, V.2    Yates, D.R.3    Bourgade, V.4    Parra, J.5
  • 25
    • 42749083410 scopus 로고    scopus 로고
    • Patient satisfaction after dual implantation of inflatable penile and artificial urinary sphincter prostheses
    • Mancini JG, Kizer WS, Jones LA, Mora RV, Morey AF. Patient satisfaction after dual implantation of inflatable penile and artificial urinary sphincter prostheses. Urology 2008; 71: 893-6.
    • (2008) Urology , vol.71 , pp. 893-896
    • Mancini, J.G.1    Kizer, W.S.2    Jones, L.A.3    Mora, R.V.4    Morey, A.F.5
  • 26
    • 40849107756 scopus 로고    scopus 로고
    • Perineal approach for artificial urinary sphincter implantation appears to control male stress incontinence better than the transscrotal approach
    • Henry GD, Graham SM, Cleves M.A., Simmons CJ, Flynn B. Perineal approach for artificial urinary sphincter implantation appears to control male stress incontinence better than the transscrotal approach. J Urol 2008; 179: 1475-9.
    • (2008) J Urol , vol.179 , pp. 1475-1479
    • Henry, G.D.1    Graham, S.M.2    Cleves, M.A.3    Simmons, C.J.4    Flynn, B.5
  • 27
    • 0033978232 scopus 로고    scopus 로고
    • Postprostatectomy urinary incontinence: The case for artificial urinary sphincter implantation
    • Montague DK, Angermeier KW. Postprostatectomy urinary incontinence: the case for artificial urinary sphincter implantation. Urology 2000; 55: 2-4.
    • (2000) Urology , vol.55 , pp. 2-4
    • Montague, D.K.1    Angermeier, K.W.2
  • 28
    • 36349002816 scopus 로고    scopus 로고
    • Dual implantation of penile and sphincter implants in the post-prostatectomy patient
    • Kumar R, Nehra A. Dual implantation of penile and sphincter implants in the post-prostatectomy patient. Curr Urol Rep 2007; 8: 477-81.
    • (2007) Curr Urol Rep , vol.8 , pp. 477-481
    • Kumar, R.1    Nehra, A.2
  • 29
    • 18844430285 scopus 로고    scopus 로고
    • Cost and time benefits of dual implantation of inflatable penile and artificial urinary sphincter prosthetics by single incision
    • Sellers CL, Morey AF, Jones LA. Cost and time benefits of dual implantation of inflatable penile and artificial urinary sphincter prosthetics by single incision. Urology 2005; 65: 852-3.
    • (2005) Urology , vol.65 , pp. 852-853
    • Sellers, C.L.1    Morey, A.F.2    Jones, L.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.