메뉴 건너뛰기




Volumn 1, Issue 1, 2013, Pages

A two-channel detection method for autofluorescence correction and efficient on-bead screening of one-bead one-compound combinatorial libraries using the COPAS fluorescence activated bead sorting system

Author keywords

[No Author keywords available]

Indexed keywords


EID: 84940056597     PISSN: None     EISSN: 20506120     Source Type: Journal    
DOI: 10.1088/2050-6120/1/1/017001     Document Type: Article
Times cited : (15)

References (29)
  • 1
    • 38349101338 scopus 로고    scopus 로고
    • Screening of a one bead-one compound combinatorial library for β-actin identifies molecules active toward Ramos B-lymphoma cells
    • Miyamoto S, Liu R, Hung S, Wang X and Lam K S 2008 Screening of a one bead-one compound combinatorial library for β-actin identifies molecules active toward Ramos B-lymphoma cells Anal. Biochem. 374 112-20
    • (2008) Anal. Biochem. , vol.374 , pp. 112-120
    • Miyamoto, S.1    Liu, R.2    Hung, S.3    Wang, X.4    Lam, K.S.5
  • 2
    • 58949090838 scopus 로고    scopus 로고
    • Synthesis and screening of a cyclic peptide library: Discovery of small-molecule ligands against human prolactin receptor
    • Liu T, Joo S H, Voorhees J L, Brooks C L and Pei D 2009 Synthesis and screening of a cyclic peptide library: discovery of small-molecule ligands against human prolactin receptor Bioorg. Med. Chem. 17 1026-33
    • (2009) Bioorg. Med. Chem. , vol.17 , pp. 1026-1033
    • Liu, T.1    Joo, S.H.2    Voorhees, J.L.3    Brooks, C.L.4    Pei, D.5
  • 3
    • 78649884200 scopus 로고    scopus 로고
    • Random glycopeptide bead libraries for seromic biomarker discovery
    • Kračun S K et al 2010 Random glycopeptide bead libraries for seromic biomarker discovery J. Proteome Res. 9 6705-14
    • (2010) J. Proteome Res. , vol.9 , pp. 6705-6714
    • Kračun, S.K.1
  • 4
    • 84866108537 scopus 로고    scopus 로고
    • Towards mimicking short linear peptide motifs: Identification of new mixed α, β-peptidomimetic ligands for SLAM-Associated Protein (SAP) by confocal on-bead screening
    • Hintersteiner M, Knox A, Mudd G and Auer M 2012 Towards mimicking short linear peptide motifs: identification of new mixed α, β-peptidomimetic ligands for SLAM-Associated Protein (SAP) by confocal on-bead screening J. Chem. Biol. 5 63-79
    • (2012) J. Chem. Biol. , vol.5 , pp. 63-79
    • Hintersteiner, M.1    Knox, A.2    Mudd, G.3    Auer, M.4
  • 5
    • 4344626204 scopus 로고    scopus 로고
    • Transformation of low-affinity lead compounds into high-affinity protein capture agents
    • Reddy M M, Bachhawat-Sikder K and Kodadek T 2004 Transformation of low-affinity lead compounds into high-affinity protein capture agents Chem. Biol. 11 1127-37
    • (2004) Chem. Biol. , vol.11 , pp. 1127-1137
    • Reddy, M.M.1    Bachhawat-Sikder, K.2    Kodadek, T.3
  • 7
    • 34347208609 scopus 로고    scopus 로고
    • Identification of a peptoid inhibitor of the proteasome 19S regulatory particle
    • Lim H-S, Archer C T and Kodadek T 2007 Identification of a peptoid inhibitor of the proteasome 19S regulatory particle J. Am. Chem. Soc. 129 7750-1
    • (2007) J. Am. Chem. Soc. , vol.129 , pp. 7750-7751
    • Lim, H.-S.1    Archer, C.T.2    Kodadek, T.3
  • 8
    • 0033783911 scopus 로고    scopus 로고
    • Determination of the binding specificity of the SH2 domains of protein tyrosine phosphatase SHP-1 through the screening of a combinatorial phosphotyrosyl peptide library
    • Beebe K D, Wang P, Arabaci G and Pei D 2000 Determination of the binding specificity of the SH2 domains of protein tyrosine phosphatase SHP-1 through the screening of a combinatorial phosphotyrosyl peptide library Biochemistry 39 13251-60
    • (2000) Biochemistry , vol.39 , pp. 13251-13260
    • Beebe, K.D.1    Wang, P.2    Arabaci, G.3    Pei, D.4
  • 9
    • 80052745646 scopus 로고    scopus 로고
    • High-throughput screening of one-bead-one-compound libraries: Identification of cyclic peptidyl inhibitors against calcineurin/NFAT interaction
    • Liu T, Qian Z, Xiao Q and Pei D 2011 High-throughput screening of one-bead-one-compound libraries: identification of cyclic peptidyl inhibitors against calcineurin/NFAT interaction ACS Comb. Sci. 13 537-46
    • (2011) ACS Comb. Sci. , vol.13 , pp. 537-546
    • Liu, T.1    Qian, Z.2    Xiao, Q.3    Pei, D.4
  • 10
    • 78650323748 scopus 로고    scopus 로고
    • HDAC6 and Ubp-M BUZ domains recognize specific C-terminal sequences of proteins
    • Hard R L, Liu J, Shen J, Zhou P and Pei D 2010 HDAC6 and Ubp-M BUZ domains recognize specific C-terminal sequences of proteins Biochemistry 49 10737-46
    • (2010) Biochemistry , vol.49 , pp. 10737-10746
    • Hard, R.L.1    Liu, J.2    Shen, J.3    Zhou, P.4    Pei, D.5
  • 11
    • 77957758524 scopus 로고    scopus 로고
    • Determination of the substrate specificity of protein-tyrosine phosphatase TULA-2 and identification of syk as a TULA-2 substrate
    • Chen X et al 2010 Determination of the substrate specificity of protein-tyrosine phosphatase TULA-2 and identification of syk as a TULA-2 substrate J. Biol. Chem. 285 31268-76
    • (2010) J. Biol. Chem. , vol.285 , pp. 31268-31276
    • Chen, X.1
  • 12
    • 3342967725 scopus 로고    scopus 로고
    • The chemical hunt for the identification of drugable targets 1
    • Meisner N C et al 2004 The chemical hunt for the identification of drugable targets 1 Curr. Opin. Chem. Biol. 8 424-31
    • (2004) Curr. Opin. Chem. Biol. , vol.8 , pp. 424-431
    • Meisner, N.C.1
  • 13
    • 77958113414 scopus 로고    scopus 로고
    • Identification of a small molecule inhibitor of importin b mediated nuclear import by confocal on-bead screening of tagged one-bead one-compound libraries
    • Hintersteiner M et al 2010 Identification of a small molecule inhibitor of importin b mediated nuclear import by confocal on-bead screening of tagged one-bead one-compound libraries ACS Chem. Biol. 5 967-79
    • (2010) ACS Chem. Biol. , vol.5 , pp. 967-979
    • Hintersteiner, M.1
  • 14
    • 33645506465 scopus 로고    scopus 로고
    • Optimized protocols for the isolation of specific protein-binding peptides or peptoids from combinatorial libraries displayed on beads 1
    • Kodadek T and Bachhawat-Sikder K 2006 Optimized protocols for the isolation of specific protein-binding peptides or peptoids from combinatorial libraries displayed on beads 1 Mol. Biosyst. 2 25-35
    • (2006) Mol. Biosyst. , vol.2 , pp. 25-35
    • Kodadek, T.1    Bachhawat-Sikder, K.2
  • 15
    • 67749119955 scopus 로고    scopus 로고
    • Single bead labeling method for combining confocal fluorescence on-bead screening and solution validation of tagged one-bead one-compound libraries
    • Hintersteiner M et al 2009 Single bead labeling method for combining confocal fluorescence on-bead screening and solution validation of tagged one-bead one-compound libraries Chem. Biol. 16 724-35
    • (2009) Chem. Biol. , vol.16 , pp. 724-735
    • Hintersteiner, M.1
  • 16
    • 0344443721 scopus 로고    scopus 로고
    • Quantum dots as a visual aid for screening bead-bound combinatorial libraries
    • Olivos H J, Bachhawat-Sikder K and Kodadek T 2003 Quantum dots as a visual aid for screening bead-bound combinatorial libraries ChemBioChem 4 1242-5
    • (2003) ChemBioChem , vol.4 , pp. 1242-1245
    • Olivos, H.J.1    Bachhawat-Sikder, K.2    Kodadek, T.3
  • 17
    • 75149127271 scopus 로고    scopus 로고
    • On-bead library screening made easier
    • Pei D 2010 On-bead library screening made easier Chem. Biol. 17 3-4
    • (2010) Chem. Biol. , vol.17 , pp. 3-4
    • Pei, D.1
  • 18
    • 75149135954 scopus 로고    scopus 로고
    • Seamless bead to microarray screening: Rapid identification of the highest affinity protein ligands from large combinatorial libraries
    • Astle J M et al 2010 Seamless bead to microarray screening: rapid identification of the highest affinity protein ligands from large combinatorial libraries Chem. Biol. 17 38-45
    • (2010) Chem. Biol. , vol.17 , pp. 38-45
    • Astle, J.M.1
  • 19
    • 67749150858 scopus 로고    scopus 로고
    • Confocal nanoscanning, bead picking (CONA): Picko screen microscopes for automated and quantitative screening of one-bead one-compound libraries
    • Hintersteiner M et al 2009 Confocal nanoscanning, bead picking (CONA): picko screen microscopes for automated and quantitative screening of one-bead one-compound libraries J. Comb. Chem. 11 886-94
    • (2009) J. Comb. Chem. , vol.11 , pp. 886-894
    • Hintersteiner, M.1
  • 20
    • 30144435945 scopus 로고    scopus 로고
    • SIRT1 top 40 hits: Use of one-bead, one-compound acetyl-peptide libraries and quantum dots to probe deacetylase specificity
    • Garske A L and Denu J M 2006 SIRT1 top 40 hits: use of one-bead, one-compound acetyl-peptide libraries and quantum dots to probe deacetylase specificity Biochemistry 45 94-101
    • (2006) Biochemistry , vol.45 , pp. 94-101
    • Garske, A.L.1    Denu, J.M.2
  • 21
    • 60849100790 scopus 로고    scopus 로고
    • Screening of one-bead-one-peptide combinatorial library using red fluorescent dyes. Presence of positive and false positive beads
    • Marani M M et al 2009 Screening of one-bead-one-peptide combinatorial library using red fluorescent dyes. Presence of positive and false positive beads J. Comb. Chem. 11 146-50
    • (2009) J. Comb. Chem. , vol.11 , pp. 146-150
    • Marani, M.M.1
  • 22
    • 33845510644 scopus 로고    scopus 로고
    • Aminodeoxychorismate synthase inhibitors from one-bead one-compound combinatorial libraries: Staged' inhibitor design
    • Dixon S et al 2006 Aminodeoxychorismate synthase inhibitors from one-bead one-compound combinatorial libraries:'staged' inhibitor design J. Med. Chem. 49 7413-26
    • (2006) J. Med. Chem. , vol.49 , pp. 7413-7426
    • Dixon, S.1
  • 23
    • 77955722797 scopus 로고    scopus 로고
    • 3-nitro-tyrosine as an internal quencher of autofluorescence enhances the compatibility of fluorescence based screening of OBOC combinatorial libraries Comb
    • Townsend J et al 2010 3-nitro-tyrosine as an internal quencher of autofluorescence enhances the compatibility of fluorescence based screening of OBOC combinatorial libraries Comb. Chem. High Throughput Screen 13 422-9
    • (2010) Chem. High Throughput Screen , vol.13 , pp. 422-429
    • Townsend, J.1
  • 24
    • 84867546573 scopus 로고    scopus 로고
    • On-bead screens sample narrower affinity ranges of protein-ligand interactions compared to equivalent solution assays
    • Hintersteiner M, Buehler C and Auer M 2012 On-bead screens sample narrower affinity ranges of protein-ligand interactions compared to equivalent solution assays ChemPhysChem 13 3472-80
    • (2012) ChemPhysChem , vol.13 , pp. 3472-3480
    • Hintersteiner, M.1    Buehler, C.2    Auer, M.3
  • 25
    • 0022820657 scopus 로고
    • Cell-by-cell autofluorescence correction for low signal-to-noise systems: Application to epidermal growth factor endocytosis by 3T3 fibroblasts
    • Roederer M and Murphy R F 1986 Cell-by-cell autofluorescence correction for low signal-to-noise systems: application to epidermal growth factor endocytosis by 3T3 fibroblasts Cytometry 7 558-65
    • (1986) Cytometry , vol.7 , pp. 558-565
    • Roederer, M.1    Murphy, R.F.2
  • 26
    • 0028894703 scopus 로고
    • Autofluorescence correction for fluorescence in situ hybridization
    • Szöllösi J, Lockett S J, Balázs M and Waldman F M 1995 Autofluorescence correction for fluorescence in situ hybridization Cytometry 20 356-61
    • (1995) Cytometry , vol.20 , pp. 356-361
    • Szöllösi, J.1    Lockett, S.J.2    Balázs, M.3    Waldman, F.M.4
  • 27
    • 0036199260 scopus 로고    scopus 로고
    • A ratiometric method of autofluorescence correction used for the quantification of evans blue dye fluorescence in rabbit arterial tissues
    • Murphy C L and Lever M J 2002 A ratiometric method of autofluorescence correction used for the quantification of evans blue dye fluorescence in rabbit arterial tissues Exp. Physiol. 87 163-70
    • (2002) Exp. Physiol. , vol.87 , pp. 163-170
    • Murphy, C.L.1    Lever, M.J.2
  • 28
    • 0036628631 scopus 로고    scopus 로고
    • Long wavelength fluorophores and cell-by-cell correction for autofluorescence significantly improves the accuracy of flow cytometric energy transfer measurements on a dual-laser benchtop flow cytometer
    • Sebestyén Z et al 2002 Long wavelength fluorophores and cell-by-cell correction for autofluorescence significantly improves the accuracy of flow cytometric energy transfer measurements on a dual-laser benchtop flow cytometer Cytometry 48 124-35
    • (2002) Cytometry , vol.48 , pp. 124-135
    • Sebestyén, Z.1
  • 29
    • 33644916094 scopus 로고    scopus 로고
    • A simple correction for cell autofluorescence for multiparameter cell-based analysis of human solid tumors
    • Smith C A, Pollice A, Emlet D and Shackney S E 2006 A simple correction for cell autofluorescence for multiparameter cell-based analysis of human solid tumors Cytometry B 70B 91-103
    • (2006) Cytometry B , vol.70 , pp. 91-103
    • Smith, C.A.1    Pollice, A.2    Emlet, D.3    Shackney, S.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.