메뉴 건너뛰기




Volumn 101, Issue , 2015, Pages 55-61

Laser speckle contrast imaging for assessing microcirculatory changes in multiple splanchnic organs and the gracilis muscle during hemorrhagic shock and fluid resuscitation

Author keywords

Fluid resuscitation; Hemorrhagic shock; Laser speckle contrast imaging; Microcirculation; Multiple splanchnic organs

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; BLOOD FLOW; BLOOD FLOW INTENSITY; CONTROLLED STUDY; DIAGNOSTIC IMAGING; FLUID RESUSCITATION; GRACILIS MUSCLE; HEART RATE; HEMORRHAGIC SHOCK; INTESTINE MUCOSA; KIDNEY; LASER SPECKLE CONTRAST IMAGING; LIVER; MALE; MEAN ARTERIAL PRESSURE; MICROANGIOPATHY; NONHUMAN; OXYGEN SATURATION; PEYER PATCH; PRIORITY JOURNAL; RAT; SEROSA; SEROSAL MUSCULAR LAYER; TISSUE OXYGEN SATURATION; ANIMAL; CHEMISTRY; FLUID THERAPY; HEMODYNAMICS; LASER; MICROCIRCULATION; PATHOLOGY; PHYSIOLOGY; PROCEDURES; RESUSCITATION; SHOCK, HEMORRHAGIC; SKELETAL MUSCLE; SPLANCHNIC BLOOD FLOW; WISTAR RAT;

EID: 84938877502     PISSN: 00262862     EISSN: 10959319     Source Type: Journal    
DOI: 10.1016/j.mvr.2015.06.003     Document Type: Article
Times cited : (18)

References (25)
  • 1
    • 0033194919 scopus 로고    scopus 로고
    • Near-infrared spectroscopy measurement of regional tissue oxyhemoglobin saturation during hemorrhagic shock
    • Beilman G.J., et al. Near-infrared spectroscopy measurement of regional tissue oxyhemoglobin saturation during hemorrhagic shock. Shock 1999, 12:196-200.
    • (1999) Shock , vol.12 , pp. 196-200
    • Beilman, G.J.1
  • 2
    • 77953165954 scopus 로고    scopus 로고
    • Laser speckle contrast imaging in biomedical optics
    • Boas D.A., Dunn A.K. Laser speckle contrast imaging in biomedical optics. J. Biomed. Opt. 2010, 15:011109.
    • (2010) J. Biomed. Opt. , vol.15 , pp. 011109
    • Boas, D.A.1    Dunn, A.K.2
  • 3
    • 84922260078 scopus 로고    scopus 로고
    • Laser speckle contrast imaging for assessment of abdominal visceral microcirculation in acute peritonitis: does sequential impairments exist?
    • Ding C., et al. Laser speckle contrast imaging for assessment of abdominal visceral microcirculation in acute peritonitis: does sequential impairments exist?. Microvasc. Res. 2014, 95:26-30.
    • (2014) Microvasc. Res. , vol.95 , pp. 26-30
    • Ding, C.1
  • 4
    • 67649968882 scopus 로고    scopus 로고
    • Review of laser speckle contrast techniques for visualizing tissue perfusion
    • Draijer M., et al. Review of laser speckle contrast techniques for visualizing tissue perfusion. Lasers Med. Sci. 2009, 24:639-651.
    • (2009) Lasers Med. Sci. , vol.24 , pp. 639-651
    • Draijer, M.1
  • 5
    • 60449086833 scopus 로고    scopus 로고
    • Systemic and microcirculatory responses to progressive hemorrhage
    • Dubin A., et al. Systemic and microcirculatory responses to progressive hemorrhage. Intensive Care Med. 2009, 35:556-564.
    • (2009) Intensive Care Med. , vol.35 , pp. 556-564
    • Dubin, A.1
  • 6
    • 84887048962 scopus 로고    scopus 로고
    • Synergistic deleterious effect of hypoxemia and hypovolemia on microcirculation in intestinal villi*
    • Harrois A., et al. Synergistic deleterious effect of hypoxemia and hypovolemia on microcirculation in intestinal villi*. Crit. Care Med. 2013, 41:e376-e384.
    • (2013) Crit. Care Med. , vol.41 , pp. e376-e384
    • Harrois, A.1
  • 7
    • 0036333529 scopus 로고    scopus 로고
    • Clinical review: splanchnic ischaemia
    • Jakob S.M. Clinical review: splanchnic ischaemia. Crit. Care 2002, 6:306-312.
    • (2002) Crit. Care , vol.6 , pp. 306-312
    • Jakob, S.M.1
  • 8
    • 74049114584 scopus 로고    scopus 로고
    • Fluid resuscitation does not improve renal oxygenation during hemorrhagic shock in rats
    • Legrand M., et al. Fluid resuscitation does not improve renal oxygenation during hemorrhagic shock in rats. Anesthesiology 2010, 112:119-127.
    • (2010) Anesthesiology , vol.112 , pp. 119-127
    • Legrand, M.1
  • 9
    • 79960495953 scopus 로고    scopus 로고
    • Design of a tissue oxygenation monitor and verification on human skin
    • Optical Society of America, Munich, N. Ramanujam, J. Popp (Eds.)
    • Liu H., et al. Design of a tissue oxygenation monitor and verification on human skin. Clinical and Biomedical Spectroscopy and Imaging II 2011, Vol. 8087:80871Y. Optical Society of America, Munich. N. Ramanujam, J. Popp (Eds.).
    • (2011) Clinical and Biomedical Spectroscopy and Imaging II , vol.8087 , pp. 80871Y
    • Liu, H.1
  • 10
    • 0034069937 scopus 로고    scopus 로고
    • Intestinal microvascular patterns during hemorrhagic shock
    • Morini S., et al. Intestinal microvascular patterns during hemorrhagic shock. Dig. Dis. Sci. 2000, 45:710-722.
    • (2000) Dig. Dis. Sci. , vol.45 , pp. 710-722
    • Morini, S.1
  • 11
    • 84922067358 scopus 로고    scopus 로고
    • Crystalloids versus colloids: exploring differences in fluid requirements by systematic review and meta-regression
    • Orbegozo Cortes D., et al. Crystalloids versus colloids: exploring differences in fluid requirements by systematic review and meta-regression. Anesth. Analg. 2015, 120:389-402.
    • (2015) Anesth. Analg. , vol.120 , pp. 389-402
    • Orbegozo Cortes, D.1
  • 12
    • 0029792273 scopus 로고    scopus 로고
    • Splanchnic ischemia and gut mucosal injury in sepsis and the multiple organ dysfunction syndrome
    • Pastores S.M., et al. Splanchnic ischemia and gut mucosal injury in sepsis and the multiple organ dysfunction syndrome. Am. J. Gastroenterol. 1996, 91:1697-1710.
    • (1996) Am. J. Gastroenterol. , vol.91 , pp. 1697-1710
    • Pastores, S.M.1
  • 13
    • 0033560867 scopus 로고    scopus 로고
    • Preserved arterial flow secures hepatic oxygenation during haemorrhage in the pig
    • Rasmussen A., et al. Preserved arterial flow secures hepatic oxygenation during haemorrhage in the pig. J. Physiol. 1999, 516(Pt 2):539-548.
    • (1999) J. Physiol. , vol.516 , pp. 539-548
    • Rasmussen, A.1
  • 14
    • 79957859121 scopus 로고    scopus 로고
    • Increasing the "region of interest" and "time of interest", both reduce the variability of blood flow measurements using laser speckle contrast imaging
    • Rousseau P., et al. Increasing the "region of interest" and "time of interest", both reduce the variability of blood flow measurements using laser speckle contrast imaging. Microvasc. Res. 2011, 82:88-91.
    • (2011) Microvasc. Res. , vol.82 , pp. 88-91
    • Rousseau, P.1
  • 15
    • 78249231988 scopus 로고    scopus 로고
    • Excellent reproducibility of laser speckle contrast imaging to assess skin microvascular reactivity
    • Roustit M., et al. Excellent reproducibility of laser speckle contrast imaging to assess skin microvascular reactivity. Microvasc. Res. 2010, 80:505-511.
    • (2010) Microvasc. Res. , vol.80 , pp. 505-511
    • Roustit, M.1
  • 16
    • 84922346013 scopus 로고    scopus 로고
    • Quantification of microcirculatory blood flow: a sensitive and clinically relevant prognostic marker in murine models of sepsis
    • (1985)
    • Sand C.A., et al. Quantification of microcirculatory blood flow: a sensitive and clinically relevant prognostic marker in murine models of sepsis. J. Appl. Physiol. 2015, 118:344-354. (1985).
    • (2015) J. Appl. Physiol. , vol.118 , pp. 344-354
    • Sand, C.A.1
  • 17
    • 3242711143 scopus 로고    scopus 로고
    • Hemorheological disorders in the microcirculation following hemorrhage
    • Sordia T., et al. Hemorheological disorders in the microcirculation following hemorrhage. Clin. Hemorheol. Microcirc. 2004, 30:461-462.
    • (2004) Clin. Hemorheol. Microcirc. , vol.30 , pp. 461-462
    • Sordia, T.1
  • 18
    • 84876310029 scopus 로고    scopus 로고
    • Laser speckle contrast imaging for assessment of liver microcirculation
    • Sturesson C., et al. Laser speckle contrast imaging for assessment of liver microcirculation. Microvasc. Res. 2013, 87:34-40.
    • (2013) Microvasc. Res. , vol.87 , pp. 34-40
    • Sturesson, C.1
  • 19
    • 0029948994 scopus 로고    scopus 로고
    • Determinants of splanchnic blood flow
    • Takala J. Determinants of splanchnic blood flow. Br. J. Anaesth. 1996, 77:50-58.
    • (1996) Br. J. Anaesth. , vol.77 , pp. 50-58
    • Takala, J.1
  • 20
    • 81055157019 scopus 로고    scopus 로고
    • Comparison of laser speckle contrast imaging with laser Doppler for assessing microvascular function
    • Tew G.A., et al. Comparison of laser speckle contrast imaging with laser Doppler for assessing microvascular function. Microvasc. Res. 2011, 82:326-332.
    • (2011) Microvasc. Res. , vol.82 , pp. 326-332
    • Tew, G.A.1
  • 21
    • 10244255222 scopus 로고    scopus 로고
    • Microcirculatory heterogeneity in the rat small intestine during compromised flow conditions
    • Vajda K., et al. Microcirculatory heterogeneity in the rat small intestine during compromised flow conditions. Microcirculation 2004, 11:307-315.
    • (2004) Microcirculation , vol.11 , pp. 307-315
    • Vajda, K.1
  • 22
    • 84863806331 scopus 로고    scopus 로고
    • Microcirculation follows macrocirculation in heart and gut in the acute phase of hemorrhagic shock and isovolemic autologous whole blood resuscitation in pigs
    • van Iterson M., et al. Microcirculation follows macrocirculation in heart and gut in the acute phase of hemorrhagic shock and isovolemic autologous whole blood resuscitation in pigs. Transfusion 2012, 52:1552-1559.
    • (2012) Transfusion , vol.52 , pp. 1552-1559
    • van Iterson, M.1
  • 23
    • 84862994957 scopus 로고    scopus 로고
    • Dexmedetomidine prevents alterations of intestinal microcirculation that are induced by surgical stress and pain in a novel rat model
    • Yeh Y.C., et al. Dexmedetomidine prevents alterations of intestinal microcirculation that are induced by surgical stress and pain in a novel rat model. Anesth. Analg. 2012, 115:46-53.
    • (2012) Anesth. Analg. , vol.115 , pp. 46-53
    • Yeh, Y.C.1
  • 24
    • 84859707921 scopus 로고    scopus 로고
    • Enoxaparin sodium prevents intestinal microcirculatory dysfunction in endotoxemic rats
    • Yeh Y.C., et al. Enoxaparin sodium prevents intestinal microcirculatory dysfunction in endotoxemic rats. Crit. Care 2012, 16:R59.
    • (2012) Crit. Care , vol.16 , pp. R59
    • Yeh, Y.C.1
  • 25
    • 70349876722 scopus 로고    scopus 로고
    • Mesenteric microcirculatory dysfunctions and translocation of indigenous bacteria in a rat model of strangulated small bowel obstruction
    • Zanoni F.L., et al. Mesenteric microcirculatory dysfunctions and translocation of indigenous bacteria in a rat model of strangulated small bowel obstruction. Clinics (Sao Paulo) 2009, 64:911-919.
    • (2009) Clinics (Sao Paulo) , vol.64 , pp. 911-919
    • Zanoni, F.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.