메뉴 건너뛰기




Volumn 42, Issue 2, 2015, Pages 407-420

Free-breathing pediatric MRI with nonrigid motion correction and acceleration

Author keywords

autofocus; compressed sensing; nonrigid motion; parallel imaging; pediatric abdominal MRI; soft gating

Indexed keywords

ABDOMINAL RADIOGRAPHY; ARTICLE; CHILD; CLINICAL ARTICLE; CONTRAST ENHANCEMENT; DIAPHRAGM; DIFFUSION WEIGHTED IMAGING; FEMALE; HUMAN; IMAGE DISPLAY; IMAGE QUALITY; IMAGE RECONSTRUCTION; LIVER BLOOD VESSEL; MALE; MATHEMATICAL COMPUTING; NUCLEAR MAGNETIC RESONANCE IMAGING; PEDIATRICS; PRIORITY JOURNAL; RESPIRATORY TRACT PARAMETERS; VOLUMETRY; ACCELERATION; ALGORITHM; ARTIFACT; BREATHING MECHANICS; COMPUTER ASSISTED DIAGNOSIS; IMAGE ENHANCEMENT; MOTION; OBSERVER VARIATION; PRESCHOOL CHILD; PROCEDURES; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; THREE DIMENSIONAL IMAGING;

EID: 84937564434     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.24785     Document Type: Article
Times cited : (137)

References (39)
  • 1
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ,. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997; 38: 591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 3
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • Griswold MA, Jakob PM, Heidemann RM, et al., Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002; 47: 1202-1210.
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 4
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM,. Sparse MRI: The application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58: 1182-1195.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 6
    • 84902367741 scopus 로고    scopus 로고
    • Clinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstruction
    • Zhang T, Chowdhury S, Lustig M, et al., Clinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstruction. J Magn Reson Imaging 2014; 40: 13-25.
    • (2014) J Magn Reson Imaging , vol.40 , pp. 13-25
    • Zhang, T.1    Chowdhury, S.2    Lustig, M.3
  • 7
    • 0036206253 scopus 로고    scopus 로고
    • Detection and elimination of motion artifacts by regeneration of k-space
    • Bydder M, Larkman DJ, Hajnal JV,. Detection and elimination of motion artifacts by regeneration of k-space. Magn Reson Med 2002; 47: 677-686.
    • (2002) Magn Reson Med , vol.47 , pp. 677-686
    • Bydder, M.1    Larkman, D.J.2    Hajnal, J.V.3
  • 9
    • 81355147706 scopus 로고    scopus 로고
    • Compressed-sensing motion compensation (CosMo): A joint prospective-retrospective respiratory navigator for coronary MRI
    • Moghari MH, Akçakaya M, O'Connor A, et al., Compressed-sensing motion compensation (CosMo): a joint prospective-retrospective respiratory navigator for coronary MRI. Magn Reson Med 2011; 66: 1674-1681.
    • (2011) Magn Reson Med , vol.66 , pp. 1674-1681
    • Moghari, M.H.1    Akçakaya, M.2    O'Connor, A.3
  • 10
    • 0027093023 scopus 로고
    • Projection reconstruction techniques for reduction of motion effects in MRI
    • Glover GH, Pauly JM,. Projection reconstruction techniques for reduction of motion effects in MRI. Magn Reson Med 1992; 28: 275-289.
    • (1992) Magn Reson Med , vol.28 , pp. 275-289
    • Glover, G.H.1    Pauly, J.M.2
  • 11
    • 0036319895 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory
    • Barger A V, Block WF, Toropov Y, Grist TM, Mistretta CA,. Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory. Magn Reson Med 2002; 48: 297-305.
    • (2002) Magn Reson Med , vol.48 , pp. 297-305
    • Barger, A.V.1    Block, W.F.2    Toropov, Y.3    Grist, T.M.4    Mistretta, C.A.5
  • 12
    • 84871607756 scopus 로고    scopus 로고
    • Free-breathing contrast-enhanced multiphase MRI of the liver using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling
    • Chandarana H, Feng L, Block TK, et al., Free-breathing contrast-enhanced multiphase MRI of the liver using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling. Invest Radiol 2013; 48: 10-16.
    • (2013) Invest Radiol , vol.48 , pp. 10-16
    • Chandarana, H.1    Feng, L.2    Block, T.K.3
  • 13
    • 30344446972 scopus 로고    scopus 로고
    • Three-dimensional reconstruction of limited-view projections for contrast-enhanced magnetic resonance angiography at high temporal and spatial resolution
    • Huang Y, Gurr D, Wright GA,. Three-dimensional reconstruction of limited-view projections for contrast-enhanced magnetic resonance angiography at high temporal and spatial resolution. Magn Reson Med 2006; 55: 68-74.
    • (2006) Magn Reson Med , vol.55 , pp. 68-74
    • Huang, Y.1    Gurr, D.2    Wright, G.A.3
  • 14
    • 77955114700 scopus 로고    scopus 로고
    • 3D undersampled golden-radial phase encoding for DCE-MRA using inherently regularized iterative SENSE
    • Prieto C, Uribe S, Razavi R, Atkinson D, Schaeffter T,. 3D undersampled golden-radial phase encoding for DCE-MRA using inherently regularized iterative SENSE. Magn Reson Med 2010; 64: 514-526.
    • (2010) Magn Reson Med , vol.64 , pp. 514-526
    • Prieto, C.1    Uribe, S.2    Razavi, R.3    Atkinson, D.4    Schaeffter, T.5
  • 15
    • 46849091615 scopus 로고    scopus 로고
    • Generalized reconstruction by inversion of coupled systems (GRICS) applied to free-breathing MRI
    • Odille F, Vuissoz P-A, Marie P-Y, Felblinger J,. Generalized reconstruction by inversion of coupled systems (GRICS) applied to free-breathing MRI. Magn Reson Med 2008; 60: 146-157.
    • (2008) Magn Reson Med , vol.60 , pp. 146-157
    • Odille, F.1    Vuissoz, P.-A.2    Marie, P.-Y.3    Felblinger, J.4
  • 16
    • 79958770897 scopus 로고    scopus 로고
    • Hierarchical adaptive local affine registration for fast and robust respiratory motion estimation
    • Buerger C, Schaeffter T, King AP,. Hierarchical adaptive local affine registration for fast and robust respiratory motion estimation. Med Image Anal 2011; 15: 551-564.
    • (2011) Med Image Anal , vol.15 , pp. 551-564
    • Buerger, C.1    Schaeffter, T.2    King, A.P.3
  • 17
    • 81355161604 scopus 로고    scopus 로고
    • Nonrigid retrospective respiratory motion correction in whole-heart coronary MRA
    • Schmidt JFM, Buehrer M, Boesiger P, Kozerke S,. Nonrigid retrospective respiratory motion correction in whole-heart coronary MRA. Magn Reson Med 2011; 66: 1541-1549.
    • (2011) Magn Reson Med , vol.66 , pp. 1541-1549
    • Schmidt, J.F.M.1    Buehrer, M.2    Boesiger, P.3    Kozerke, S.4
  • 21
    • 84861227005 scopus 로고    scopus 로고
    • Improved least squares MR image reconstruction using estimates of k-space data consistency
    • Johnson KM, Block WF, Reeder SB, Samsonov A,. Improved least squares MR image reconstruction using estimates of k-space data consistency. Magn Reson Med 2012; 67: 1600-1608.
    • (2012) Magn Reson Med , vol.67 , pp. 1600-1608
    • Johnson, K.M.1    Block, W.F.2    Reeder, S.B.3    Samsonov, A.4
  • 22
    • 84937613970 scopus 로고    scopus 로고
    • Reduction of respiratory motion artifacts for free-breathing whole-heart coronary MRA by weighted iterative reconstruction
    • [Epub ahead of print].
    • Forman C, Piccini D, Grimm R, Hutter J, Hornegger J, Zenge MO,. Reduction of respiratory motion artifacts for free-breathing whole-heart coronary MRA by weighted iterative reconstruction. Magn Reson Med 2014 [Epub ahead of print].
    • (2014) Magn Reson Med
    • Forman, C.1    Piccini, D.2    Grimm, R.3    Hutter, J.4    Hornegger, J.5    Zenge, M.O.6
  • 24
    • 30344458822 scopus 로고    scopus 로고
    • Undersampled elliptical centric view-order for improved spatial resolution in contrast-enhanced MR angiography
    • Madhuranthakam AJ, Hu HH, Barger AV, et al., Undersampled elliptical centric view-order for improved spatial resolution in contrast-enhanced MR angiography. Magn Reson Med 2006; 55: 50-58.
    • (2006) Magn Reson Med , vol.55 , pp. 50-58
    • Madhuranthakam, A.J.1    Hu, H.H.2    Barger, A.V.3
  • 25
    • 51449092401 scopus 로고    scopus 로고
    • 3D high temporal and spatial resolution contrast-enhanced MR angiography of the whole brain
    • Haider CR, Hu HH, Campeau NG, Huston J, Riederer SJ,. 3D high temporal and spatial resolution contrast-enhanced MR angiography of the whole brain. Magn Reson Med 2008; 60: 749-760.
    • (2008) Magn Reson Med , vol.60 , pp. 749-760
    • Haider, C.R.1    Hu, H.H.2    Campeau, N.G.3    Huston, J.4    Riederer, S.J.5
  • 26
    • 66249143725 scopus 로고    scopus 로고
    • Contrast-enhanced MR angiography using time resolved interleaved projection sampling with three-dimensional Cartesian phase and slice encoding (TRIPPS)
    • Du J,. Contrast-enhanced MR angiography using time resolved interleaved projection sampling with three-dimensional Cartesian phase and slice encoding (TRIPPS). Magn Reson Med 2009; 61: 918-924.
    • (2009) Magn Reson Med , vol.61 , pp. 918-924
    • Du, J.1
  • 30
    • 84894420593 scopus 로고    scopus 로고
    • ESPIRiT-an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA
    • Uecker M, Lai P, Murphy MJ, et al., ESPIRiT-an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA. Magn Reson Med 2014; 71: 990-1001.
    • (2014) Magn Reson Med , vol.71 , pp. 990-1001
    • Uecker, M.1    Lai, P.2    Murphy, M.J.3
  • 32
    • 77955102061 scopus 로고    scopus 로고
    • SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space
    • Lustig M, Pauly JM,. SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space. Magn Reson Med 2010; 64: 457-471.
    • (2010) Magn Reson Med , vol.64 , pp. 457-471
    • Lustig, M.1    Pauly, J.M.2
  • 33
    • 85014561619 scopus 로고    scopus 로고
    • A fast iterative shrinkage-thresholding algorithm for linear inverse problems
    • Beck A, Teboulle M,. A fast iterative shrinkage-thresholding algorithm for linear inverse problems. SIAM J Imaging Sci 2009; 2: 183-202.
    • (2009) SIAM J Imaging Sci , vol.2 , pp. 183-202
    • Beck, A.1    Teboulle, M.2
  • 34
    • 0030739762 scopus 로고    scopus 로고
    • Motion-adapted gating based on k-space weighting for reduction of respiratory motion artifacts
    • Weiger M, Börnert P, Proksa R, Schäffter T, Haase A,. Motion-adapted gating based on k-space weighting for reduction of respiratory motion artifacts. Magn Reson Med 1997; 38: 322-333.
    • (1997) Magn Reson Med , vol.38 , pp. 322-333
    • Weiger, M.1    Börnert, P.2    Proksa, R.3    Schäffter, T.4    Haase, A.5
  • 35
    • 84904474344 scopus 로고    scopus 로고
    • Nonrigid autofocus motion correction for coronary MR angiography with a 3D cones trajectory
    • Ingle RR, Wu HH, Addy NO, et al., Nonrigid autofocus motion correction for coronary MR angiography with a 3D cones trajectory. Magn Reson Med 2014; 72: 347-61.
    • (2014) Magn Reson Med , vol.72 , pp. 347-361
    • Ingle, R.R.1    Wu, H.H.2    Addy, N.O.3
  • 36
    • 51449085600 scopus 로고    scopus 로고
    • Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo
    • Busse RF, Brau ACS, Vu A, et al., Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo. Magn Reson Med 2008; 60: 640-649.
    • (2008) Magn Reson Med , vol.60 , pp. 640-649
    • Busse, R.F.1    Brau, A.C.S.2    Vu, A.3
  • 37
    • 0036845522 scopus 로고    scopus 로고
    • Single-breathhold 3D-trueFISP cine cardiac imaging
    • Jung BA, Hennig J, Scheffler K,. Single-breathhold 3D-trueFISP cine cardiac imaging. Magn Reson Med 2002; 48: 921-925.
    • (2002) Magn Reson Med , vol.48 , pp. 921-925
    • Jung, B.A.1    Hennig, J.2    Scheffler, K.3
  • 38
    • 37349080140 scopus 로고    scopus 로고
    • A software channel compression technique for faster reconstruction with many channels
    • Huang F, Vijayakumar S, Li Y, Hertel S, Duensing GR,. A software channel compression technique for faster reconstruction with many channels. Magn Reson Imaging 2008; 26: 133-141.
    • (2008) Magn Reson Imaging , vol.26 , pp. 133-141
    • Huang, F.1    Vijayakumar, S.2    Li, Y.3    Hertel, S.4    Duensing, G.R.5
  • 39
    • 84872910908 scopus 로고    scopus 로고
    • Coil compression for accelerated imaging with Cartesian sampling
    • Zhang T, Pauly JM, Vasanawala SS, Lustig M,. Coil compression for accelerated imaging with Cartesian sampling. Magn Reson Med 2013; 69: 571-582.
    • (2013) Magn Reson Med , vol.69 , pp. 571-582
    • Zhang, T.1    Pauly, J.M.2    Vasanawala, S.S.3    Lustig, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.