메뉴 건너뛰기




Volumn 71, Issue 3, 2014, Pages 990-1001

ESPIRiT - An eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA

Author keywords

autocalibration; compressed sensing; GRAPPA; parallel imaging; SENSE

Indexed keywords

COMPRESSED SENSING; EIGENVALUES AND EIGENFUNCTIONS;

EID: 84894420593     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24751     Document Type: Article
Times cited : (1286)

References (38)
  • 1
    • 0027319233 scopus 로고
    • Fast imaging using subencoding data sets from multiple detectors
    • Ra JB, Rim CY,. Fast imaging using subencoding data sets from multiple detectors. Magn Reson Med 1993; 30: 142-145.
    • (1993) Magn Reson Med , vol.30 , pp. 142-145
    • Ra, J.B.1    Rim, C.Y.2
  • 4
    • 77955102061 scopus 로고    scopus 로고
    • SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space
    • Lustig M, Pauly JM,. SPIRiT: iterative self-consistent parallel imaging reconstruction from arbitrary k-space. Magn Reson Med 2010; 64: 457-471.
    • (2010) Magn Reson Med , vol.64 , pp. 457-471
    • Lustig, M.1    Pauly, J.M.2
  • 5
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann KP, Weiger M, Börnert P, Boesiger P,. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001; 46: 638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.P.1    Weiger, M.2    Börnert, P.3    Boesiger, P.4
  • 7
    • 34250320137 scopus 로고    scopus 로고
    • Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint
    • Block KT, Uecker M, Frahm J,. Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint. Magn Reson Med 2007; 57: 1086-1098.
    • (2007) Magn Reson Med , vol.57 , pp. 1086-1098
    • Block, K.T.1    Uecker, M.2    Frahm, J.3
  • 8
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho DL, Pauly JM,. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58: 1182-1195.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.L.2    Pauly, J.M.3
  • 10
    • 34250364567 scopus 로고    scopus 로고
    • Joint image reconstruction and sensitivity estimation in SENSE (JSENSE)
    • Ying L, Sheng J,. Joint image reconstruction and sensitivity estimation in SENSE (JSENSE). Magn Reson Med 2007; 57: 1196-1202.
    • (2007) Magn Reson Med , vol.57 , pp. 1196-1202
    • Ying, L.1    Sheng, J.2
  • 11
    • 51449090553 scopus 로고    scopus 로고
    • Image reconstruction by regularized nonlinear inversion - Joint estimation of coil sensitivities and image content
    • Uecker M, Hohage T, Block KT, Frahm J,. Image reconstruction by regularized nonlinear inversion-joint estimation of coil sensitivities and image content. Magn Reson Med 2008; 60: 674-682.
    • (2008) Magn Reson Med , vol.60 , pp. 674-682
    • Uecker, M.1    Hohage, T.2    Block, K.T.3    Frahm, J.4
  • 12
    • 84861881823 scopus 로고    scopus 로고
    • Efficient L1SPIRiT reconstruction (ESPIRiT) for highly accelerated 3d volumetric MRI with parallel imaging and compressed sensing
    • In, Stockholm, Sweden, p
    • Lai P, Lustig M, Brau AC, Vasanawala S, Beatty PJ, Alley M,. Efficient L1SPIRiT reconstruction (ESPIRiT) for highly accelerated 3d volumetric MRI with parallel imaging and compressed sensing. In Proceedings of the 18th Annual Meeting of ISMRM, Stockholm, Sweden, 2010. p. 345.
    • (2010) Proceedings of the 18th Annual Meeting of ISMRM , pp. 345
    • Lai, P.1    Lustig, M.2    Brau, A.C.3    Vasanawala, S.4    Beatty, P.J.5    Alley, M.6
  • 15
    • 10044289695 scopus 로고    scopus 로고
    • POCSENSE: POCS-based reconstruction for sensitivity encoded magnetic resonance imaging
    • Samsonov AA, Kholmovski EG, Parker DL, Johnson CR,. POCSENSE: POCS-based reconstruction for sensitivity encoded magnetic resonance imaging. Magn Reson Med 2004; 52: 1397-1406.
    • (2004) Magn Reson Med , vol.52 , pp. 1397-1406
    • Samsonov, A.A.1    Kholmovski, E.G.2    Parker, D.L.3    Johnson, C.R.4
  • 16
    • 33745686035 scopus 로고    scopus 로고
    • Discrepancy-based adaptive regularization for GRAPPA reconstruction
    • Qu P, Wang C, Shen GX,. Discrepancy-based adaptive regularization for GRAPPA reconstruction. J Magn Reson Imaging 2006; 24: 248-255.
    • (2006) J Magn Reson Imaging , vol.24 , pp. 248-255
    • Qu, P.1    Wang, C.2    Shen, G.X.3
  • 17
    • 84875369339 scopus 로고    scopus 로고
    • Improved parallel MR imaging using a coefficient penalized regularization for GRAPPA reconstruction
    • Liu W, Tang X, Ma Y, Gao JH,. Improved parallel MR imaging using a coefficient penalized regularization for GRAPPA reconstruction. Magn Reson Med 2013; 69: 1109-1114.
    • (2013) Magn Reson Med , vol.69 , pp. 1109-1114
    • Liu, W.1    Tang, X.2    Ma, Y.3    Gao, J.H.4
  • 18
    • 84894461181 scopus 로고    scopus 로고
    • Nonlinear Reconstruction Methods for Parallel Magnetic Resonance Imaging
    • Georg-August-Universität Göttingen
    • Uecker M,. Nonlinear Reconstruction Methods for Parallel Magnetic Resonance Imaging, PhD thesis, Georg-August-Universität Göttingen, 2009.
    • (2009) PhD Thesis
    • Uecker, M.1
  • 19
    • 80054823866 scopus 로고    scopus 로고
    • Parallel reconstruction using null operations
    • Zhang J, Liu C, Moseley ME,. Parallel reconstruction using null operations. Magn Reson Med 2011; 66: 1241-1253.
    • (2011) Magn Reson Med , vol.66 , pp. 1241-1253
    • Zhang, J.1    Liu, C.2    Moseley, M.E.3
  • 20
    • 33744540030 scopus 로고    scopus 로고
    • The use of an adaptive reconstruction for array coil sensitivity mapping and intensity normalization
    • In, Honolulu, Hawaii, USA, p
    • Griswold M, Walsh D, Heidemann R, Haase A, Jakob P,. The use of an adaptive reconstruction for array coil sensitivity mapping and intensity normalization. In Proceedings of the 10th Annual Meeting of ISMRM, Honolulu, Hawaii, USA, 2002. p. 2410.
    • (2002) Proceedings of the 10th Annual Meeting of ISMRM , pp. 2410
    • Griswold, M.1    Walsh, D.2    Heidemann, R.3    Haase, A.4    Jakob, P.5
  • 22
    • 20744449792 scopus 로고    scopus 로고
    • The design and implementation of FFTW3
    • Frigo M, Johnson SG,. The design and implementation of FFTW3. Proc IEEE 2005; 93: 216-231.
    • (2005) Proc IEEE , vol.93 , pp. 216-231
    • Frigo, M.1    Johnson, S.G.2
  • 23
    • 80055051537 scopus 로고    scopus 로고
    • Practical parallel imaging compressed sensing MRI: Summary of two years of experience in accelerating body MRI of pediatric patients
    • In, Chicago
    • Vasanawala SS, Murphy MJ, Alley MT, Lai P, Keutzer K, Pauly JM, Lustig M,. Practical parallel imaging compressed sensing MRI: summary of two years of experience in accelerating body MRI of pediatric patients. In I S Biomed Imaging, Chicago, 2011. pp 1039-1043.
    • (2011) I S Biomed Imaging , pp. 1039-1043
    • Vasanawala, S.S.1    Murphy, M.J.2    Alley, M.T.3    Lai, P.4    Keutzer, K.5    Pauly, J.M.6    Lustig, M.7
  • 24
    • 84872910908 scopus 로고    scopus 로고
    • Coil compression for accelerated imaging with Cartesian sampling
    • Zhang T, Pauly JM, Vasanawala SS, Lustig M,. Coil compression for accelerated imaging with Cartesian sampling. Magn Reson Med 2013; 69: 571-582.
    • (2013) Magn Reson Med , vol.69 , pp. 571-582
    • Zhang, T.1    Pauly, J.M.2    Vasanawala, S.S.3    Lustig, M.4
  • 25
    • 84984520202 scopus 로고
    • The retrieval of harmonics from a covariance function
    • Pisarenko VF,. The retrieval of harmonics from a covariance function. Geophys J Roy Astr S 1973; 33: 347-366.
    • (1973) Geophys J Roy Astr S , vol.33 , pp. 347-366
    • Pisarenko, V.F.1
  • 26
    • 0022683359 scopus 로고
    • Multiple emitter location and signal parameter estimation
    • Schmidt RO,. Multiple emitter location and signal parameter estimation. IEEE Trans Antennas Propag 1986; 34: 276-280.
    • (1986) IEEE Trans Antennas Propag , vol.34 , pp. 276-280
    • Schmidt, R.O.1
  • 27
    • 0024702515 scopus 로고
    • ESPRIT - Estimation of signal parameters via rotational invariance techniques
    • Roy R, Kailath T,. ESPRIT-estimation of signal parameters via rotational invariance techniques. IEEE Trans Acoust Speech Signal Process 1989; 37: 984-995.
    • (1989) IEEE Trans Acoust Speech Signal Process , vol.37 , pp. 984-995
    • Roy, R.1    Kailath, T.2
  • 28
    • 0033078512 scopus 로고    scopus 로고
    • Perfect blind restoration of images blurred by multiple filters: Theory and efficient algorithms
    • Harikumar G, Bresler Y,. Perfect blind restoration of images blurred by multiple filters: theory and efficient algorithms. IEEE Trans Image Process 1999; 8: 202-219.
    • (1999) IEEE Trans Image Process , vol.8 , pp. 202-219
    • Harikumar, G.1    Bresler, Y.2
  • 29
    • 81455136668 scopus 로고    scopus 로고
    • Generic feasibility of perfect reconstruction with short FIR filters in multichannel systems
    • Sharif B, Bresler Y,. Generic feasibility of perfect reconstruction with short FIR filters in multichannel systems. IEEE Trans Sig Proc 2011; 59: 5814-5829.
    • (2011) IEEE Trans Sig Proc , vol.59 , pp. 5814-5829
    • Sharif, B.1    Bresler, Y.2
  • 30
    • 77955196100 scopus 로고    scopus 로고
    • Image reconstruction from phased-array MRI data based on multichannel blind deconvolution
    • In, Rotterdam
    • She H, Chen RR, Liang D, Chang Y, Ying L,. Image reconstruction from phased-array MRI data based on multichannel blind deconvolution. In I S Biomed Imaging, Rotterdam, 2010. pp 760-763.
    • (2010) I S Biomed Imaging , pp. 760-763
    • She, H.1    Chen, R.R.2    Liang, D.3    Chang, Y.4    Ying, L.5
  • 31
    • 80055036034 scopus 로고    scopus 로고
    • Distortion-optimal self-calibrating parallel MRI by blind interpolation in subsampled filter banks
    • In, Chicago
    • Sharif B, Bresler Y,. Distortion-optimal self-calibrating parallel MRI by blind interpolation in subsampled filter banks. In I S Biomed Imaging, Chicago, 2011. pp 52-56.
    • (2011) I S Biomed Imaging , pp. 52-56
    • Sharif, B.1    Bresler, Y.2
  • 32
    • 84355164748 scopus 로고    scopus 로고
    • Calibrationless parallel imaging reconstruction by structured low-rank matrix completion
    • In, Stockholm, Sweden, p
    • Lustig M, Elad M, Pauly JM,. Calibrationless parallel imaging reconstruction by structured low-rank matrix completion. In Proceedings of the 18th Annual Meeting of ISMRM, Stockholm, Sweden, 2010. p. 2870.
    • (2010) Proceedings of the 18th Annual Meeting of ISMRM , pp. 2870
    • Lustig, M.1    Elad, M.2    Pauly, J.M.3
  • 35
    • 0034060592 scopus 로고    scopus 로고
    • Adaptive reconstruction of phased array MR imagery
    • Walsh DO, Gmitro AF, Marcellin MW,. Adaptive reconstruction of phased array MR imagery. Magn Reson Med 2000; 43: 682-690.
    • (2000) Magn Reson Med , vol.43 , pp. 682-690
    • Walsh, D.O.1    Gmitro, A.F.2    Marcellin, M.W.3
  • 36
    • 36349013208 scopus 로고    scopus 로고
    • Multichannel estimation of coil sensitivities in parallel MRI
    • In, Washington
    • Morrison RL, Jacob M, Do MN,. Multichannel estimation of coil sensitivities in parallel MRI. In I S Biomed Imaging, Washington, 2007. pp 117-120.
    • (2007) I S Biomed Imaging , pp. 117-120
    • Morrison, R.L.1    Jacob, M.2    Do, M.N.3
  • 38
    • 84894459653 scopus 로고    scopus 로고
    • Making SENSE of chemical shift: Separating species in single-shot EPI using multiple coils
    • In, Melbourne, Australia, p
    • Uecker M, Lustig M,. Making SENSE of chemical shift: separating species in single-shot EPI using multiple coils. In Proceedings of the 20th Annual Meeting of ISMRM, Melbourne, Australia, 2012. p. 2490
    • (2012) Proceedings of the 20th Annual Meeting of ISMRM , pp. 2490
    • Uecker, M.1    Lustig, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.