Volumn 40, Issue 1, 2014, Pages 13-25

Clinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstruction

Author keywords

coil compression; compressed sensing; contrast enhanced abdominal pediatric MRI; parallel imaging

Indexed keywords

ADRENAL GLAND; ANATOMICAL CONCEPTS; CHILD; CLINICAL ARTICLE; COIL COMPRESSION; CONTRAST ENHANCED ABDOMINAL PEDIATRIC MAGNETIC RESONANCE IMAGING; CONTRAST ENHANCEMENT; CONTROLLED STUDY; FAST COMBINED PARALLEL IMAGING COMPRESSED SENSING METHOD; FEMALE; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; INFANT; LIVER; LIVER VEIN; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PANCREAS; PORTAL VEIN; PRIORITY JOURNAL; RADIOLOGIST; RENAL ARTERY; REVIEW; SPINE; ABDOMEN; ALGORITHM; COMPUTER ASSISTED DIAGNOSIS; DIAGNOSTIC USE; FEASIBILITY STUDY; IMAGE ENHANCEMENT; INFORMATION PROCESSING; OBSERVER VARIATION; PATHOLOGY; PRESCHOOL CHILD; PROCEDURES; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; SINGLE BLIND PROCEDURE;

EID: 84902367741     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.24333     Document Type: Review
Times cited : (86)

References (23)
  • 1
    • 43549096651 scopus 로고    scopus 로고
    • Imaging of abdominal tumours: CT or MRI?
    • Olsen OE,. Imaging of abdominal tumours: CT or MRI? Pediatr Radiol 2008; 38 (Suppl 3): 452-458.
    • (2008) Pediatr Radiol , vol.38 , Issue.SUPPL. 3 , pp. 452-458
    • Olsen, O.E.1
  • 2
    • 80053055766 scopus 로고    scopus 로고
    • MR imaging of the abdomen and pelvis in infants, children, and adolescents
    • Darge K, Anupindi SA, Jaramillo D,. MR imaging of the abdomen and pelvis in infants, children, and adolescents. Radiology 2011; 261: 12-29.
    • (2011) Radiology , vol.261 , pp. 12-29
    • Darge, K.1    Anupindi, S.A.2    Jaramillo, D.3
  • 3
    • 84856463074 scopus 로고    scopus 로고
    • Advances in pediatric body MRI
    • Vasanawala SS, Lustig M,. Advances in pediatric body MRI. Pediatr Radiol 2011; 41 (Suppl 2): 549-554.
    • (2011) Pediatr Radiol , vol.41 , Issue.SUPPL. 2 , pp. 549-554
    • Vasanawala, S.S.1    Lustig, M.2
  • 4
    • 37249046527 scopus 로고    scopus 로고
    • Deep sedation and minimal anesthesia
    • Sury MR, Smith JH,. Deep sedation and minimal anesthesia. Paediatr Anaesth 2008; 18: 18-24.
    • (2008) Paediatr Anaesth , vol.18 , pp. 18-24
    • Sury, M.R.1    Smith, J.H.2
  • 6
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002; 47: 1202-1210.
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 8
    • 33645712892 scopus 로고    scopus 로고
    • Compressed sensing
    • Donoho D,. Compressed sensing. IEEE Trans Inf Theory 2006; 52: 1289-1306.
    • (2006) IEEE Trans Inf Theory , vol.52 , pp. 1289-1306
    • Donoho, D.1
  • 9
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM,. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58: 1182-1195.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 10
    • 73149123165 scopus 로고    scopus 로고
    • Accelerating SENSE using compressed sensing
    • Liang D, Liu B, Wang J, Ying L,. Accelerating SENSE using compressed sensing. Magn Reson Med 2009; 62: 1574-1584.
    • (2009) Magn Reson Med , vol.62 , pp. 1574-1584
    • Liang, D.1    Liu, B.2    Wang, J.3    Ying, L.4
  • 12
    • 80055051537 scopus 로고    scopus 로고
    • Practical parallel imaging compressed sensing MRI: Summary of two years of experience in accelerating body MRI of pediatric patients
    • Chicago
    • Vasanawala SS, Murphy MJ, Alley MT, et al. Practical parallel imaging compressed sensing MRI: summary of two years of experience in accelerating body MRI of pediatric patients. In: Proceedings of IEEE International Symposium on Biomedical Imaging, Chicago, 2011. p 1039-1043.
    • (2011) Proceedings of IEEE International Symposium on Biomedical Imaging , pp. 1039-1043
    • Vasanawala, S.S.1    Murphy, M.J.2    Alley, M.T.3
  • 13
    • 38949120094 scopus 로고    scopus 로고
    • Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods
    • Brau AC, Beatty PJ, Skare S, Bammer R,. Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods. Magn Reson Med 2008; 59: 382-395.
    • (2008) Magn Reson Med , vol.59 , pp. 382-395
    • Brau, A.C.1    Beatty, P.J.2    Skare, S.3    Bammer, R.4
  • 14
    • 84861844027 scopus 로고    scopus 로고
    • Fast L1-SPIRiT compressed sensing parallel imaging MRI: Scalable parallel implementation and clinically feasible runtime
    • Murphy M, Alley M, Demmel J, Keutzer K, Vasanawala S, Lustig M,. Fast L1-SPIRiT compressed sensing parallel imaging MRI: scalable parallel implementation and clinically feasible runtime. IEEE Trans Med Imaging 2012; 31: 1250-1262.
    • (2012) IEEE Trans Med Imaging , vol.31 , pp. 1250-1262
    • Murphy, M.1    Alley, M.2    Demmel, J.3    Keutzer, K.4    Vasanawala, S.5    Lustig, M.6
  • 15
    • 84867891452 scopus 로고    scopus 로고
    • Millimeter isotropic resolution volumetric pediatric abdominal MRI with a dedicated 32 channel phased array coil
    • Montreal, (abstract 161)
    • Vasanawala S, Grafendorfer T, Calderon P, et al. Millimeter isotropic resolution volumetric pediatric abdominal MRI with a dedicated 32 channel phased array coil. In: Proceedings of the 19th Annual Meeting of ISMRM, Montreal, 2011. (abstract 161).
    • (2011) Proceedings of the 19th Annual Meeting of ISMRM
    • Vasanawala, S.1    Grafendorfer, T.2    Calderon, P.3
  • 16
    • 22744435455 scopus 로고    scopus 로고
    • 64-channel array coil for single echo acquisition magnetic resonance imaging
    • McDougall MP, Wright SM,. 64-channel array coil for single echo acquisition magnetic resonance imaging. Magn Reson Med 2005; 54: 386-392.
    • (2005) Magn Reson Med , vol.54 , pp. 386-392
    • McDougall, M.P.1    Wright, S.M.2
  • 17
    • 44949111448 scopus 로고    scopus 로고
    • A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 Telsa
    • Schmitt M, Potthast A, Sosnovik DE, et al. A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 Telsa. Magn Reson Med 2008; 59: 1431-1439.
    • (2008) Magn Reson Med , vol.59 , pp. 1431-1439
    • Schmitt, M.1    Potthast, A.2    Sosnovik, D.E.3
  • 19
    • 37349080140 scopus 로고    scopus 로고
    • A software channel compression technique for faster reconstruction with many channels
    • Huang F, Vijayakumar S, Li Y, Hertel S, Duensing GR,. A software channel compression technique for faster reconstruction with many channels. Magn Reson Imaging 2008; 26: 133-141.
    • (2008) Magn Reson Imaging , vol.26 , pp. 133-141
    • Huang, F.1    Vijayakumar, S.2    Li, Y.3    Hertel, S.4    Duensing, G.R.5
  • 20
    • 84872910908 scopus 로고    scopus 로고
    • Coil compression for accelerated imaging with Cartesian sampling
    • Zhang T, Pauly JM, Vasanawala SS, Lustig M,. Coil compression for accelerated imaging with Cartesian sampling. Magn Reson Med 2013; 69: 571-582.
    • (2013) Magn Reson Med , vol.69 , pp. 571-582
    • Zhang, T.1    Pauly, J.M.2    Vasanawala, S.S.3    Lustig, M.4
  • 21
    • 77955102061 scopus 로고    scopus 로고
    • SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space
    • Lustig M, Pauly JM,. SPIRiT: iterative self-consistent parallel imaging reconstruction from arbitrary k-space. Magn Reson Med 2010; 64: 457-471.
    • (2010) Magn Reson Med , vol.64 , pp. 457-471
    • Lustig, M.1    Pauly, J.M.2
  • 22
    • 85043358321 scopus 로고    scopus 로고
    • Improved time-resolved, 3D phase contrast imaging through variable Poisson sampling and partial respiratory triggering
    • Montreal, (abstract 1218
    • Alley MT, Murphy MJ, Keutzer K, et al. Improved time-resolved, 3D phase contrast imaging through variable Poisson sampling and partial respiratory triggering. In: Proceedings of the 19th Annual Meeting of ISMRM, Montreal, 2011. (abstract 1218.
    • (2011) Proceedings of the 19th Annual Meeting of ISMRM
    • Alley, M.T.1    Murphy, M.J.2    Keutzer, K.3
  • 23
    • 38949156006 scopus 로고    scopus 로고
    • A method for autocalibrating 2-D accelerated volumetric parallel imaging with clinically practical reconstruction times
    • Berlin, (abstract 1749)
    • Beatty P, Brau A, Chang S, et al. A method for autocalibrating 2-D accelerated volumetric parallel imaging with clinically practical reconstruction times. In: Proceedings of the 15th Annual Meeting of ISMRM, Berlin, 2007. (abstract 1749).
    • (2007) Proceedings of the 15th Annual Meeting of ISMRM
    • Beatty, P.1    Brau, A.2    Chang, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.