Volumn 114, Issue , 2015, Pages 53-61

Capillary isoelectric focusing method development and validation for investigation of recombinant therapeutic monoclonal antibody

Author keywords

Capillary electrophoresis; Isoelectric focusing; Method development; Monoclonal antibody; Validation

Indexed keywords

MONOCLONAL ANTIBODY; PEPTIDE; PROTEIN; RECOMBINANT ANTIBODY; BUFFER; ELECTROLYTE; IMMUNOGLOBULIN G; INORGANIC SALT; ISOPROTEIN; RECOMBINANT PROTEIN; UREA;

EID: 84930216206     PISSN: 07317085     EISSN: 1873264X     Source Type: Journal    
DOI: 10.1016/j.jpba.2015.04.037     Document Type: Article
Times cited : (44)

References (21)
  • 1
    • 84883879484 scopus 로고    scopus 로고
    • Physicochemical and functional comparability between the proposed biosimilar rituximab GP2013 and originator rituximab
    • Visser J., Feuerstein I., Stangler T., Schmiederer T., Fritsch C., Schiestl M. Physicochemical and functional comparability between the proposed biosimilar rituximab GP2013 and originator rituximab. BioDrugs 2013, 27:495-507.
    • (2013) BioDrugs , vol.27 , pp. 495-507
    • Visser, J.1    Feuerstein, I.2    Stangler, T.3    Schmiederer, T.4    Fritsch, C.5    Schiestl, M.6
  • 3
    • 0019934863 scopus 로고
    • Structural and numerical variations of the carbohydrate moiety of immunoglobulin G
    • Mizuochi T., Taniguchi T., Shimizu A., Kobata A. Structural and numerical variations of the carbohydrate moiety of immunoglobulin G. J. Immunol. 1982, 129:2016-2020.
    • (1982) J. Immunol. , vol.129 , pp. 2016-2020
    • Mizuochi, T.1    Taniguchi, T.2    Shimizu, A.3    Kobata, A.4
  • 4
    • 0025218112 scopus 로고
    • Structural heterogeneity of sugar chains in immunoglobulin G. Conformation of immunoglobulin G molecule and substrate specificities of glycosyltransferases
    • Fujii S., Nishiura T., Nishikawa A., Miura R., Taniguchi N. Structural heterogeneity of sugar chains in immunoglobulin G. Conformation of immunoglobulin G molecule and substrate specificities of glycosyltransferases. J. Biol. Chem. 1990, 265:6009-6018.
    • (1990) J. Biol. Chem. , vol.265 , pp. 6009-6018
    • Fujii, S.1    Nishiura, T.2    Nishikawa, A.3    Miura, R.4    Taniguchi, N.5
  • 6
    • 81055126364 scopus 로고    scopus 로고
    • Imaged capillary isoelectric focusing for charge-variant analysis of biopharmaceuticals
    • Michels D.A., Salas-Solano O., Felten C. Imaged capillary isoelectric focusing for charge-variant analysis of biopharmaceuticals. Bioprocess Int. 2011, 9(10):48-54.
    • (2011) Bioprocess Int. , vol.9 , Issue.10 , pp. 48-54
    • Michels, D.A.1    Salas-Solano, O.2    Felten, C.3
  • 7
    • 77958549515 scopus 로고    scopus 로고
    • Rapid comparison of a candidate biosimilar to an innovator monoclonal antibody with advanced liquid chromatography and mass spectrometry technologies
    • Xie H., Chakraborty A., Ahn J., Yu Y.Q., Dakshinamoorthy D.P., Gilar M., Chen W., St.Skilton J., Mazzeo J.F. Rapid comparison of a candidate biosimilar to an innovator monoclonal antibody with advanced liquid chromatography and mass spectrometry technologies. mAbs 2010, 2:379-394.
    • (2010) mAbs , vol.2 , pp. 379-394
    • Xie, H.1    Chakraborty, A.2    Ahn, J.3    Yu, Y.Q.4    Dakshinamoorthy, D.P.5    Gilar, M.6    Chen, W.7    Skilton, S.J.8    Mazzeo, J.F.9
  • 8
    • 84877328542 scopus 로고    scopus 로고
    • Top-down structural analysis of an intact monoclonal antibody by electron capture dissociation-fourier transform ion cyclotron resonance-mass spectrometry
    • Mao Y., Valeja S.G., Rouse J.C., Hendrickson C.L., Marshall A.G. Top-down structural analysis of an intact monoclonal antibody by electron capture dissociation-fourier transform ion cyclotron resonance-mass spectrometry. Anal. Chem. 2013, 85:4239-4246.
    • (2013) Anal. Chem. , vol.85 , pp. 4239-4246
    • Mao, Y.1    Valeja, S.G.2    Rouse, J.C.3    Hendrickson, C.L.4    Marshall, A.G.5
  • 9
    • 84899912693 scopus 로고    scopus 로고
    • Charge profiling and stability testing of biosimilar by capillary isoelectric focusing
    • Cao J., Sun W., Gong F., Liu W. Charge profiling and stability testing of biosimilar by capillary isoelectric focusing. Electrophoresis 2014, 35:1461-1468.
    • (2014) Electrophoresis , vol.35 , pp. 1461-1468
    • Cao, J.1    Sun, W.2    Gong, F.3    Liu, W.4
  • 10
    • 0025914761 scopus 로고
    • Coated capillaries and additives for the separation of proteins by capillary zone electrophoresis and capillary isoelectric focusing
    • Mazzeo J.R., Krull I.S. Coated capillaries and additives for the separation of proteins by capillary zone electrophoresis and capillary isoelectric focusing. Biotechniques 1991, 10:638-645.
    • (1991) Biotechniques , vol.10 , pp. 638-645
    • Mazzeo, J.R.1    Krull, I.S.2
  • 11
    • 0001171807 scopus 로고
    • Adaptation of the equipment for high-performance electrophoresis to isoelectric focusing
    • Hjerten S., Zhu M.D. Adaptation of the equipment for high-performance electrophoresis to isoelectric focusing. J. Chromatogr. A. 1985, 346:265-270.
    • (1985) J. Chromatogr. A. , vol.346 , pp. 265-270
    • Hjerten, S.1    Zhu, M.D.2
  • 12
    • 84897445031 scopus 로고    scopus 로고
    • Development of imaged capillary isoelectric focusing method and use of capillary zone electrophoresis in hepatitis B vaccine RECOMBIVAX HB®
    • Rustandi R.R., Wang F., Hamm C., Cuciniello J.J., Marley M.L. Development of imaged capillary isoelectric focusing method and use of capillary zone electrophoresis in hepatitis B vaccine RECOMBIVAX HB®. Electrophoresis 2014, 35:1072-1078.
    • (2014) Electrophoresis , vol.35 , pp. 1072-1078
    • Rustandi, R.R.1    Wang, F.2    Hamm, C.3    Cuciniello, J.J.4    Marley, M.L.5
  • 13
    • 59249095069 scopus 로고    scopus 로고
    • Application of imaging capillary IEF for characterization and quantitative analysis of recombinant protein charge heterogeneity
    • Sosic Z., Houde D., Blum A., Carlage T., Lyubarskaya Y. Application of imaging capillary IEF for characterization and quantitative analysis of recombinant protein charge heterogeneity. Electrophoresis 2008, 29:4368-4376.
    • (2008) Electrophoresis , vol.29 , pp. 4368-4376
    • Sosic, Z.1    Houde, D.2    Blum, A.3    Carlage, T.4    Lyubarskaya, Y.5
  • 14
    • 65949125092 scopus 로고    scopus 로고
    • Analysis of charge heterogeneities in mAbs using imaged CE
    • He X.Z., Que A.H., Mo J.J. Analysis of charge heterogeneities in mAbs using imaged CE. Electrophoresis 2009, 30:714-722.
    • (2009) Electrophoresis , vol.30 , pp. 714-722
    • He, X.Z.1    Que, A.H.2    Mo, J.J.3
  • 15
    • 33644653747 scopus 로고    scopus 로고
    • Free-flow zone electrophoresis and isoelectric focusing using a microfabricated glass device with ion permeable membranes
    • Kohlheyer D., Besselink G.A.J., Schlautmann S., Schasfoort R.B.M. Free-flow zone electrophoresis and isoelectric focusing using a microfabricated glass device with ion permeable membranes. Lab Chip 2006, 6:374-380.
    • (2006) Lab Chip , vol.6 , pp. 374-380
    • Kohlheyer, D.1    Besselink, G.A.J.2    Schlautmann, S.3    Schasfoort, R.B.M.4
  • 17
    • 72849122502 scopus 로고    scopus 로고
    • A systematic study in CIEF: Defining and optimizing experimental parameters critical to method reproducibility and robustness
    • Mack S., Cruzado-Park I., Chapman J., Ratnayake C., Vigh G. A systematic study in CIEF: Defining and optimizing experimental parameters critical to method reproducibility and robustness. Electrophoresis 2009, 30:4049-4058.
    • (2009) Electrophoresis , vol.30 , pp. 4049-4058
    • Mack, S.1    Cruzado-Park, I.2    Chapman, J.3    Ratnayake, C.4    Vigh, G.5
  • 18
    • 34248223594 scopus 로고    scopus 로고
    • CIEF with hydrodynamic and chemical mobilization for the separation of forms of α-1-acid glycoprotein
    • Lacunza I., Diez-Masa J.C., de Frutos M. CIEF with hydrodynamic and chemical mobilization for the separation of forms of α-1-acid glycoprotein. Electrophoresis 2007, 28:1204-1213.
    • (2007) Electrophoresis , vol.28 , pp. 1204-1213
    • Lacunza, I.1    Diez-Masa, J.C.2    de Frutos, M.3
  • 20
    • 84866506945 scopus 로고    scopus 로고
    • Development and validation of a rapid capillary zone electrophoresis method for determining charge variants of mAb
    • Shi Y., Li Z., Qiao Y., Lin J. Development and validation of a rapid capillary zone electrophoresis method for determining charge variants of mAb. J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 2012, 906:63-68.
    • (2012) J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. , vol.906 , pp. 63-68
    • Shi, Y.1    Li, Z.2    Qiao, Y.3    Lin, J.4
  • 21
    • 79960363638 scopus 로고    scopus 로고
    • A high-resolution capillary isoelectric focusing method for the determination of therapeutic recombinant monoclonal antibody
    • Lin J., Tan Q., Wang S. A high-resolution capillary isoelectric focusing method for the determination of therapeutic recombinant monoclonal antibody. J. Sep. Sci. 2011, 35:1696-1702.
    • (2011) J. Sep. Sci. , vol.35 , pp. 1696-1702
    • Lin, J.1    Tan, Q.2    Wang, S.3