메뉴 건너뛰기




Volumn 25, Issue 6, 2015, Pages 1598-1606

Chest CT using spectral filtration: radiation dose, image quality, and spectrum of clinical utility

Author keywords

Pneumonia; Radiation dose; Spectral filtration; Thorax; X ray computed tomography

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CONTRAST TO NOISE RATIO; CONTROLLED STUDY; DIAGNOSTIC VALUE; FEMALE; FIGURE OF MERIT; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; IMAGE RECONSTRUCTION; LUNG DISEASE; LUNG NODULE; LUNG PARENCHYMA; MALE; PILOT STUDY; PLEURA DISEASE; PNEUMONIA; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE REDUCTION; RADIOLOGICAL PARAMETERS; RADIOMETRY; RETROSPECTIVE STUDY; SIZE SPECIFIC DOSE ESTIMATE; SPECTRAL FILTRATION COMPUTED TOMOGRAPHY; STATISTICAL ANALYSIS; IMAGE ENHANCEMENT; IMAGE PROCESSING; LUNG; MIDDLE AGED; OBSERVER VARIATION; PROCEDURES; RADIOGRAPHY; REPRODUCIBILITY;

EID: 84930002836     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-014-3559-1     Document Type: Article
Times cited : (67)

References (22)
  • 1
    • 0034055634 scopus 로고    scopus 로고
    • Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions
    • COI: 1:STN:280:DC%2BD3c7jtV2huw%3D%3D, PID: 10663775
    • Greess H, Wolf H, Baum U et al (2000) Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions. Eur Radiol 10:391–394
    • (2000) Eur Radiol , vol.10 , pp. 391-394
    • Greess, H.1    Wolf, H.2    Baum, U.3
  • 2
    • 0041343248 scopus 로고    scopus 로고
    • Dose reduction in multidetector CT using attenuation-based online tube current modulation
    • Tack D, De Maertelaer V, Gevenois PA (2003) Dose reduction in multidetector CT using attenuation-based online tube current modulation. Am J Roentgenol 181:331–334
    • (2003) Am J Roentgenol , vol.181 , pp. 331-334
    • Tack, D.1    De Maertelaer, V.2    Gevenois, P.A.3
  • 3
    • 1342266221 scopus 로고    scopus 로고
    • Strategies for CT radiation dose optimization
    • PID: 14739312
    • Kalra MK, Maher MM, Toth TL et al (2004) Strategies for CT radiation dose optimization. Radiology 230:619–628
    • (2004) Radiology , vol.230 , pp. 619-628
    • Kalra, M.K.1    Maher, M.M.2    Toth, T.L.3
  • 4
    • 80052962265 scopus 로고    scopus 로고
    • Radiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image space
    • COI: 1:STN:280:DC%2BC3Mfktlamug%3D%3D, PID: 21861995
    • Hu XH, Ding XF, Wu RZ, Zhang MM (2011) Radiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image space. Clin Radiol 66:1023–1029
    • (2011) Clin Radiol , vol.66 , pp. 1023-1029
    • Hu, X.H.1    Ding, X.F.2    Wu, R.Z.3    Zhang, M.M.4
  • 5
    • 84870380018 scopus 로고    scopus 로고
    • Low-dose CT of the lung: potential value of iterative reconstructions
    • PID: 22699873
    • Baumueller S, Winklehner A, Karlo C et al (2012) Low-dose CT of the lung: potential value of iterative reconstructions. Eur Radiol 22:2597–2606
    • (2012) Eur Radiol , vol.22 , pp. 2597-2606
    • Baumueller, S.1    Winklehner, A.2    Karlo, C.3
  • 6
    • 84868319541 scopus 로고    scopus 로고
    • Radiation dose reduction of chest CT with iterative reconstruction in image space – part I: studies on image quality using dual source CT
    • PID: 23118569
    • Hwang HJ, Seo JB, Lee JS et al (2012) Radiation dose reduction of chest CT with iterative reconstruction in image space – part I: studies on image quality using dual source CT. Korean J Radiol 13:711–719
    • (2012) Korean J Radiol , vol.13 , pp. 711-719
    • Hwang, H.J.1    Seo, J.B.2    Lee, J.S.3
  • 7
    • 84863666413 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: a pilot study
    • Yamada Y, Jinzaki M, Tanami Y et al (2012) Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: a pilot study. Investig Radiol 47:482–489
    • (2012) Investig Radiol , vol.47 , pp. 482-489
    • Yamada, Y.1    Jinzaki, M.2    Tanami, Y.3
  • 8
    • 84874935300 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique
    • Katsura M, Matsuda I, Akahane M et al (2013) Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique. Investig Radiol 48:206–212
    • (2013) Investig Radiol , vol.48 , pp. 206-212
    • Katsura, M.1    Matsuda, I.2    Akahane, M.3
  • 9
    • 84878598953 scopus 로고    scopus 로고
    • Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations
    • PID: 22892722
    • Neroladaki A, Botsikas D, Boudabbous S, Becker CD, Montet X (2013) Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations. Eur Radiol 23:360–366
    • (2013) Eur Radiol , vol.23 , pp. 360-366
    • Neroladaki, A.1    Botsikas, D.2    Boudabbous, S.3    Becker, C.D.4    Montet, X.5
  • 10
    • 84902172225 scopus 로고    scopus 로고
    • Ultralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping
    • Gordic S, Morsbach F, Schmidt B et al (2014) Ultralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping. Investig Radiol
    • (2014) Investig Radiol
    • Gordic, S.1    Morsbach, F.2    Schmidt, B.3
  • 11
    • 84902368516 scopus 로고    scopus 로고
    • Image quality and radiation dose of low tube voltage 3 generation dual-source coronary CT angiography in obese patients: a phantom study
    • Meinel FG, Canstein C, Schoepf UJ et al (2014) Image quality and radiation dose of low tube voltage 3 generation dual-source coronary CT angiography in obese patients: a phantom study. Eur Radiol
    • (2014) Eur Radiol
    • Meinel, F.G.1    Canstein, C.2    Schoepf, U.J.3
  • 12
    • 77957358643 scopus 로고    scopus 로고
    • Multisection CT protocols: sex-and age-specific conversion factors used to determine effective dose from dose-length product
    • PID: 20851940
    • Deak PD, Smal Y, Kalender WA (2010) Multisection CT protocols: sex-and age-specific conversion factors used to determine effective dose from dose-length product. Radiology 257:158
    • (2010) Radiology , vol.257 , pp. 158
    • Deak, P.D.1    Smal, Y.2    Kalender, W.A.3
  • 14
    • 84867954971 scopus 로고    scopus 로고
    • Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations
    • Boone J, Strauss K, Cody D et al (2011) Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations. Report of AAPM Task Group 204
    • (2011) Report of AAPM Task Group , pp. 204
    • Boone, J.1    Strauss, K.2    Cody, D.3
  • 15
    • 75349092506 scopus 로고    scopus 로고
    • Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm—initial clinical experience
    • PID: 20032149
    • Marin D, Nelson RC, Schindera ST et al (2010) Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm—initial clinical experience. Radiology 254:145–153
    • (2010) Radiology , vol.254 , pp. 145-153
    • Marin, D.1    Nelson, R.C.2    Schindera, S.T.3
  • 16
    • 0003415539 scopus 로고
    • Practical statistics for medical research
    • Altman DG (1990) Practical statistics for medical research. CRC Press
    • (1990) CRC Press
    • Altman, D.G.1
  • 17
    • 80051481645 scopus 로고    scopus 로고
    • Sequential versus volumetric computed tomography in the follow-up of chronic bronchopulmonary diseases: comparison of diagnostic information and radiation dose in 63 adults
    • PID: 21785287
    • Bendaoud S, Remy-Jardin M, Wallaert B et al (2011) Sequential versus volumetric computed tomography in the follow-up of chronic bronchopulmonary diseases: comparison of diagnostic information and radiation dose in 63 adults. J Thorac Imaging 26:190–195
    • (2011) J Thorac Imaging , vol.26 , pp. 190-195
    • Bendaoud, S.1    Remy-Jardin, M.2    Wallaert, B.3
  • 18
    • 84876366477 scopus 로고    scopus 로고
    • Reduced-dose low-voltage chest CT angiography with Sinogram-affirmed iterative reconstruction versus standard-dose filtered back projection
    • PID: 23297336
    • Pontana F, Pagniez J, Duhamel A et al (2013) Reduced-dose low-voltage chest CT angiography with Sinogram-affirmed iterative reconstruction versus standard-dose filtered back projection. Radiology 267:609–618
    • (2013) Radiology , vol.267 , pp. 609-618
    • Pontana, F.1    Pagniez, J.2    Duhamel, A.3
  • 19
    • 41649097351 scopus 로고    scopus 로고
    • Ultra-low-dose MDCT of the chest: influence on automated lung nodule detection
    • PID: 18385555
    • Lee JY, Chung MJ, Yi CA, Lee KS (2008) Ultra-low-dose MDCT of the chest: influence on automated lung nodule detection. Korean J Radiol 9:95–101
    • (2008) Korean J Radiol , vol.9 , pp. 95-101
    • Lee, J.Y.1    Chung, M.J.2    Yi, C.A.3    Lee, K.S.4
  • 20
    • 47249166093 scopus 로고    scopus 로고
    • Effective doses in radiology and diagnostic nuclear medicine: a catalog
    • PID: 18566177
    • Mettler FA, Huda W, Yoshizumi TT, Mahesh M (2008) Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248:254
    • (2008) Radiology , vol.248 , pp. 254
    • Mettler, F.A.1    Huda, W.2    Yoshizumi, T.T.3    Mahesh, M.4
  • 21
    • 84857880921 scopus 로고    scopus 로고
    • Chest CT incidentalomas: thyroid lesions, enlarged mediastinal lymph nodes, and lung nodules
    • PID: 22391408
    • Frank L, Quint LE (2012) Chest CT incidentalomas: thyroid lesions, enlarged mediastinal lymph nodes, and lung nodules. Cancer Imaging 12:41–48
    • (2012) Cancer Imaging , vol.12 , pp. 41-48
    • Frank, L.1    Quint, L.E.2
  • 22
    • 84878100233 scopus 로고    scopus 로고
    • Respiratory tract infections in the immunocompromised
    • PID: 23508112
    • Godbole G, Gant V (2013) Respiratory tract infections in the immunocompromised. Curr Opin Pulm Med 19:244–250
    • (2013) Curr Opin Pulm Med , vol.19 , pp. 244-250
    • Godbole, G.1    Gant, V.2