메뉴 건너뛰기




Volumn 23, Issue 2, 2015, Pages 217-229

Hyperpolarized Gas MR Imaging: Technique and Applications

Author keywords

Hyperpolarized gas; Lung imaging; MR imaging; Pulmonary gas exchange; Pulmonary ventilation; Xenon (129Xe)

Indexed keywords

HELIUM; XENON; ISOTOPE;

EID: 84929317815     PISSN: 10649689     EISSN: 15579786     Source Type: Journal    
DOI: 10.1016/j.mric.2015.01.003     Document Type: Review
Times cited : (89)

References (49)
  • 1
    • 84871511126 scopus 로고    scopus 로고
    • Deaths: preliminary data for 2011
    • Hoyert D.L., Xu J. Deaths: preliminary data for 2011. Natl Vital Stat Rep 2012, 61(6):1-51.
    • (2012) Natl Vital Stat Rep , vol.61 , Issue.6 , pp. 1-51
    • Hoyert, D.L.1    Xu, J.2
  • 2
    • 78650915946 scopus 로고    scopus 로고
    • Costs of asthma in the United States: 2002-2007
    • Barnett S.B., Nurmagambetov T.A. Costs of asthma in the United States: 2002-2007. JAllergy Clin Immunol 2011, 127(1):145-152.
    • (2011) JAllergy Clin Immunol , vol.127 , Issue.1 , pp. 145-152
    • Barnett, S.B.1    Nurmagambetov, T.A.2
  • 3
    • 84870765540 scopus 로고    scopus 로고
    • Incidence and prevalence of idiopathic pulmonary fibrosis: review of the literature
    • Nalysnyk L., Cid-Ruzafa J., Rotella P., et al. Incidence and prevalence of idiopathic pulmonary fibrosis: review of the literature. Eur Respir Rev 2012, 21(126):355-361.
    • (2012) Eur Respir Rev , vol.21 , Issue.126 , pp. 355-361
    • Nalysnyk, L.1    Cid-Ruzafa, J.2    Rotella, P.3
  • 4
    • 2942720573 scopus 로고    scopus 로고
    • The nature of small-airway obstruction in chronic obstructive pulmonary disease
    • Hogg J.C., Chu F., Utokaparch S., et al. The nature of small-airway obstruction in chronic obstructive pulmonary disease. NEngl J Med 2004, 350(26):2645-2653.
    • (2004) NEngl J Med , vol.350 , Issue.26 , pp. 2645-2653
    • Hogg, J.C.1    Chu, F.2    Utokaparch, S.3
  • 5
    • 0031020842 scopus 로고    scopus 로고
    • Clinical and personality profiles and survival in patients with COPD
    • Ashutosh K., Haldipur C., Boucher M.L. Clinical and personality profiles and survival in patients with COPD. Chest 1997, 111(1):95-98.
    • (1997) Chest , vol.111 , Issue.1 , pp. 95-98
    • Ashutosh, K.1    Haldipur, C.2    Boucher, M.L.3
  • 6
    • 0029023351 scopus 로고
    • Evaluation of the short-form 36-item questionnaire to measure health-related quality of life in patients with COPD
    • Mahler D.A., Mackowiak J.I. Evaluation of the short-form 36-item questionnaire to measure health-related quality of life in patients with COPD. Chest 1995, 107(6):1585-1589.
    • (1995) Chest , vol.107 , Issue.6 , pp. 1585-1589
    • Mahler, D.A.1    Mackowiak, J.I.2
  • 7
    • 0036252278 scopus 로고    scopus 로고
    • Dyspnea is a better predictor of 5-year survival than airway obstruction in patients with COPD
    • Nishimura K., Izumi T., Tsukino M., et al. Dyspnea is a better predictor of 5-year survival than airway obstruction in patients with COPD. Chest 2002, 121(5):1434-1440.
    • (2002) Chest , vol.121 , Issue.5 , pp. 1434-1440
    • Nishimura, K.1    Izumi, T.2    Tsukino, M.3
  • 8
    • 33744826801 scopus 로고    scopus 로고
    • Early emphysematous changes in asymptomatic smokers: detection with 3HE MR imaging 1
    • Fain S.B., Panth S.R., Evans M.D., et al. Early emphysematous changes in asymptomatic smokers: detection with 3HE MR imaging 1. Radiology 2006, 239(3):875-883.
    • (2006) Radiology , vol.239 , Issue.3 , pp. 875-883
    • Fain, S.B.1    Panth, S.R.2    Evans, M.D.3
  • 9
    • 77953937210 scopus 로고    scopus 로고
    • Chronic obstructive pulmonary disease: longitudinal hyperpolarized 3He MR imaging 1
    • Kirby M., Mathew L., Wheatley A., et al. Chronic obstructive pulmonary disease: longitudinal hyperpolarized 3He MR imaging 1. Radiology 2010, 256(1):280-289.
    • (2010) Radiology , vol.256 , Issue.1 , pp. 280-289
    • Kirby, M.1    Mathew, L.2    Wheatley, A.3
  • 10
    • 0032871921 scopus 로고    scopus 로고
    • Hyperpolarized 3He-enhanced MR imaging of lung transplant recipients: preliminary results
    • McAdams H.P., Palmer S.M., Donnelly L.F., et al. Hyperpolarized 3He-enhanced MR imaging of lung transplant recipients: preliminary results. AJR Am J Roentgenol 1999, 173(4):955-959.
    • (1999) AJR Am J Roentgenol , vol.173 , Issue.4 , pp. 955-959
    • McAdams, H.P.1    Palmer, S.M.2    Donnelly, L.F.3
  • 11
    • 33750451994 scopus 로고    scopus 로고
    • Hyperpolarized 3helium magnetic resonance ventilation imaging of the lung in cystic fibrosis: comparison with high resolution CT and spirometry
    • McMahon C.J., Dodd J.D., Hill C., et al. Hyperpolarized 3helium magnetic resonance ventilation imaging of the lung in cystic fibrosis: comparison with high resolution CT and spirometry. Eur Radiol 2006, 16(11):2483-2490.
    • (2006) Eur Radiol , vol.16 , Issue.11 , pp. 2483-2490
    • McMahon, C.J.1    Dodd, J.D.2    Hill, C.3
  • 12
    • 27244452469 scopus 로고    scopus 로고
    • Hyperpolarized HHe 3 MRI of the lung in cystic fibrosis
    • Mentore K., Froh D.K., de Lange E.E., et al. Hyperpolarized HHe 3 MRI of the lung in cystic fibrosis. Acad Radiol 2005, 12(11):1423-1429.
    • (2005) Acad Radiol , vol.12 , Issue.11 , pp. 1423-1429
    • Mentore, K.1    Froh, D.K.2    de Lange, E.E.3
  • 13
    • 0036136992 scopus 로고    scopus 로고
    • Emphysema: hyperpolarized helium 3 diffusion MR imaging of the lungs compared with spirometric indexes-initial experience1
    • Salerno M., de Lange E.E., Altes T.A., et al. Emphysema: hyperpolarized helium 3 diffusion MR imaging of the lungs compared with spirometric indexes-initial experience1. Radiology 2002, 222(1):252-260.
    • (2002) Radiology , vol.222 , Issue.1 , pp. 252-260
    • Salerno, M.1    de Lange, E.E.2    Altes, T.A.3
  • 14
    • 79959696672 scopus 로고    scopus 로고
    • For some, helium-3 supply picture is brightening
    • Kramer D. For some, helium-3 supply picture is brightening. Physics Today 2011.
    • (2011) Physics Today
    • Kramer, D.1
  • 15
    • 84908405683 scopus 로고    scopus 로고
    • Measuring diffusion limitation with a perfusion-limited gas-hyperpolarized 129Xe gas-transfer spectroscopy in patients with idiopathic pulmonary fibrosis
    • Kaushik S.S., Freeman M.S., Yoon S.W., et al. Measuring diffusion limitation with a perfusion-limited gas-hyperpolarized 129Xe gas-transfer spectroscopy in patients with idiopathic pulmonary fibrosis. JAppl Physiol (1985) 2014, 117(6):577-585.
    • (2014) JAppl Physiol (1985) , vol.117 , Issue.6 , pp. 577-585
    • Kaushik, S.S.1    Freeman, M.S.2    Yoon, S.W.3
  • 16
    • 0028466202 scopus 로고
    • Biological magnetic resonance imaging using laser-polarized 129Xe
    • Albert M.S., Cates G.D., Driehuys B., et al. Biological magnetic resonance imaging using laser-polarized 129Xe. Nature 1994, 370(6486):199-201.
    • (1994) Nature , vol.370 , Issue.6486 , pp. 199-201
    • Albert, M.S.1    Cates, G.D.2    Driehuys, B.3
  • 17
    • 8544247178 scopus 로고    scopus 로고
    • MR imaging and spectroscopy using hyperpolarized 129Xe gas: preliminary human results
    • Mugler J.P., Driehuys B., Brookeman J.R. MR imaging and spectroscopy using hyperpolarized 129Xe gas: preliminary human results. Magn Reson Med 1997, 37:809-815.
    • (1997) Magn Reson Med , vol.37 , pp. 809-815
    • Mugler, J.P.1    Driehuys, B.2    Brookeman, J.R.3
  • 18
    • 0026584549 scopus 로고
    • Anaesthesia and the 'inert' gases with special reference to xenon
    • Kennedy R.R., Stokes J.W., Downing P. Anaesthesia and the 'inert' gases with special reference to xenon. Anaesth Intensive Care 1992, 20(1):66-70.
    • (1992) Anaesth Intensive Care , vol.20 , Issue.1 , pp. 66-70
    • Kennedy, R.R.1    Stokes, J.W.2    Downing, P.3
  • 19
    • 0039669134 scopus 로고    scopus 로고
    • Nuclear magnetic resonance imaging with hyperpolarised helium-3
    • Ebert M., Grossmann T., Heil W., et al. Nuclear magnetic resonance imaging with hyperpolarised helium-3. Lancet 1996, 347(9011):1297-1299.
    • (1996) Lancet , vol.347 , Issue.9011 , pp. 1297-1299
    • Ebert, M.1    Grossmann, T.2    Heil, W.3
  • 20
    • 8944220243 scopus 로고    scopus 로고
    • Human lung air spaces: potential for MR imaging with hyperpolarized He-3
    • MacFall J.R., Charles H.C., Black R.D., et al. Human lung air spaces: potential for MR imaging with hyperpolarized He-3. Radiology 1996, 200(2):553-558.
    • (1996) Radiology , vol.200 , Issue.2 , pp. 553-558
    • MacFall, J.R.1    Charles, H.C.2    Black, R.D.3
  • 21
    • 73249132982 scopus 로고    scopus 로고
    • Hyperpolarised 3He MRI versus HRCT in COPD and normal volunteers: PHIL trial
    • van Beek E.J., Dahmen A.M., Stavngaard T., et al. Hyperpolarised 3He MRI versus HRCT in COPD and normal volunteers: PHIL trial. Eur Respir J 2009, 34(6):1311-1321.
    • (2009) Eur Respir J , vol.34 , Issue.6 , pp. 1311-1321
    • van Beek, E.J.1    Dahmen, A.M.2    Stavngaard, T.3
  • 22
    • 0344980295 scopus 로고    scopus 로고
    • Spatially resolved measurements of hyperpolarized gas properties in the lung invivo. Part I: diffusion coefficient
    • Chen X.J., Möller H.E., Chawla M.S., et al. Spatially resolved measurements of hyperpolarized gas properties in the lung invivo. Part I: diffusion coefficient. Magn Reson Med 1999, 42(4):721-728.
    • (1999) Magn Reson Med , vol.42 , Issue.4 , pp. 721-728
    • Chen, X.J.1    Möller, H.E.2    Chawla, M.S.3
  • 23
    • 79952785642 scopus 로고    scopus 로고
    • Diffusion-weighted hyperpolarized 129Xe MRI in healthy volunteers and subjects with chronic obstructive pulmonary disease
    • Kaushik S.S., Cleveland Z.I., Cofer G.P., et al. Diffusion-weighted hyperpolarized 129Xe MRI in healthy volunteers and subjects with chronic obstructive pulmonary disease. Magn Reson Med 2011, 65(4):1154-1165.
    • (2011) Magn Reson Med , vol.65 , Issue.4 , pp. 1154-1165
    • Kaushik, S.S.1    Cleveland, Z.I.2    Cofer, G.P.3
  • 24
    • 19344368069 scopus 로고    scopus 로고
    • Emphysematous changes and normal variation in smokers and COPD patients using diffusion 3He MRI
    • Swift A.J., Wild J.M., Fichele S., et al. Emphysematous changes and normal variation in smokers and COPD patients using diffusion 3He MRI. Eur J Radiol 2005, 54(3):352-358.
    • (2005) Eur J Radiol , vol.54 , Issue.3 , pp. 352-358
    • Swift, A.J.1    Wild, J.M.2    Fichele, S.3
  • 25
    • 36148998718 scopus 로고    scopus 로고
    • Hyperpolarized (129)Xe MRI: a viable functional lung imaging modality?
    • Patz S., Hersman F.W., Muradian I., et al. Hyperpolarized (129)Xe MRI: a viable functional lung imaging modality?. Eur J Radiol 2007, 64(3):335-344.
    • (2007) Eur J Radiol , vol.64 , Issue.3 , pp. 335-344
    • Patz, S.1    Hersman, F.W.2    Muradian, I.3
  • 26
    • 0023144262 scopus 로고
    • Adverse reactions to xenon-enhanced CT cerebral blood flow determination
    • Latchaw R.E., Yonas H., Pentheny S.L., et al. Adverse reactions to xenon-enhanced CT cerebral blood flow determination. Radiology 1987, 163(1):251-254.
    • (1987) Radiology , vol.163 , Issue.1 , pp. 251-254
    • Latchaw, R.E.1    Yonas, H.2    Pentheny, S.L.3
  • 27
    • 84455200725 scopus 로고    scopus 로고
    • Chronic obstructive pulmonary disease: safety and tolerability of hyperpolarized 129Xe MR imaging in healthy volunteers and patients
    • Driehuys B., Martinez-Jimenez S., Cleveland Z.I., et al. Chronic obstructive pulmonary disease: safety and tolerability of hyperpolarized 129Xe MR imaging in healthy volunteers and patients. Radiology 2012, 262(1):279-289.
    • (2012) Radiology , vol.262 , Issue.1 , pp. 279-289
    • Driehuys, B.1    Martinez-Jimenez, S.2    Cleveland, Z.I.3
  • 28
    • 33144457338 scopus 로고    scopus 로고
    • Optical pumping system design for large production of hyperpolarized Xe 129
    • Ruset I.C., Ketel S., Hersman F.W. Optical pumping system design for large production of hyperpolarized Xe 129. Phys Rev Lett 2006, 96(5):53002.
    • (2006) Phys Rev Lett , vol.96 , Issue.5 , pp. 53002
    • Ruset, I.C.1    Ketel, S.2    Hersman, F.W.3
  • 29
    • 84863477192 scopus 로고    scopus 로고
    • Hyperpolarized 129Xe magnetic resonance imaging: tolerability in healthy volunteers and subjects with pulmonary disease
    • Shukla Y., Wheatley A., Kirby M., et al. Hyperpolarized 129Xe magnetic resonance imaging: tolerability in healthy volunteers and subjects with pulmonary disease. Acad Radiol 2012, 19(8):941-951.
    • (2012) Acad Radiol , vol.19 , Issue.8 , pp. 941-951
    • Shukla, Y.1    Wheatley, A.2    Kirby, M.3
  • 30
    • 0001482464 scopus 로고
    • Nuclear polarization in He 3 gas induced by optical pumping and dipolar exchange
    • Bouchiat M.A., Carver T.R., Varnum C.M. Nuclear polarization in He 3 gas induced by optical pumping and dipolar exchange. Phys Rev Lett 1960.
    • (1960) Phys Rev Lett
    • Bouchiat, M.A.1    Carver, T.R.2    Varnum, C.M.3
  • 31
    • 85017728399 scopus 로고
    • The optical production and the optical detection of an inequality of population of the levels of spatial quantification of atoms. Application to the experiments
    • Kastler A. The optical production and the optical detection of an inequality of population of the levels of spatial quantification of atoms. Application to the experiments. JPhys Radium 1950.
    • (1950) JPhys Radium
    • Kastler, A.1
  • 32
    • 0036299548 scopus 로고    scopus 로고
    • Nuclear magnetic resonance of laser-polarized noble gases in molecules, materials, and organisms
    • Goodson B.M. Nuclear magnetic resonance of laser-polarized noble gases in molecules, materials, and organisms. JMagn Reson 2002, 155(2):157-216.
    • (2002) JMagn Reson , vol.155 , Issue.2 , pp. 157-216
    • Goodson, B.M.1
  • 33
    • 0031480383 scopus 로고    scopus 로고
    • Spin-exchange optical pumping of noble-gas nuclei
    • Walker T.G., Happer W. Spin-exchange optical pumping of noble-gas nuclei. Rev Mod Phys 1997, 69(2):629-642.
    • (1997) Rev Mod Phys , vol.69 , Issue.2 , pp. 629-642
    • Walker, T.G.1    Happer, W.2
  • 34
    • 84883373676 scopus 로고    scopus 로고
    • Near-unity nuclear polarization with an open-source 129Xe hyperpolarizer for NMR and MRI
    • Nikolaou P., Coffey A.M., Walkup L.L., et al. Near-unity nuclear polarization with an open-source 129Xe hyperpolarizer for NMR and MRI. Proc Natl Acad Sci U S A 2013, 110:14150-14155.
    • (2013) Proc Natl Acad Sci U S A , vol.110 , pp. 14150-14155
    • Nikolaou, P.1    Coffey, A.M.2    Walkup, L.L.3
  • 35
    • 0031593279 scopus 로고    scopus 로고
    • Biomedical imaging using hyperpolarized noble gas MRI: pulse sequence considerations
    • Zhao L., Albert M.S. Biomedical imaging using hyperpolarized noble gas MRI: pulse sequence considerations. Nucl Instrum Methods Phys Res A 1998, 402:454-460.
    • (1998) Nucl Instrum Methods Phys Res A , vol.402 , pp. 454-460
    • Zhao, L.1    Albert, M.S.2
  • 37
    • 84863397729 scopus 로고    scopus 로고
    • Direct visualisation of collateral ventilation in COPD with hyperpolarised gas MRI
    • Marshall H., Deppe M.H., Parra-Robles J., et al. Direct visualisation of collateral ventilation in COPD with hyperpolarised gas MRI. Thorax 2012, 67(7):613-617.
    • (2012) Thorax , vol.67 , Issue.7 , pp. 613-617
    • Marshall, H.1    Deppe, M.H.2    Parra-Robles, J.3
  • 38
    • 84890110300 scopus 로고    scopus 로고
    • Hyperpolarized (3) He and (129) Xe MRI: differences in asthma before bronchodilation
    • Svenningsen S., Kirby M., Starr D., et al. Hyperpolarized (3) He and (129) Xe MRI: differences in asthma before bronchodilation. JMagn Reson Imaging 2013, 38(6):1521-1530.
    • (2013) JMagn Reson Imaging , vol.38 , Issue.6 , pp. 1521-1530
    • Svenningsen, S.1    Kirby, M.2    Starr, D.3
  • 39
    • 84890549460 scopus 로고    scopus 로고
    • Lung injury induced by secondhand smoke exposure detected with hyperpolarized helium-3 diffusion MR
    • Wang C., Mugler J.P., de Lange E.E., et al. Lung injury induced by secondhand smoke exposure detected with hyperpolarized helium-3 diffusion MR. JMagn Reson Imaging 2014, 39(1):77-84.
    • (2014) JMagn Reson Imaging , vol.39 , Issue.1 , pp. 77-84
    • Wang, C.1    Mugler, J.P.2    de Lange, E.E.3
  • 40
    • 27244442120 scopus 로고    scopus 로고
    • Detection of age-dependent changes in healthy adult lungs with diffusion-weighted 3He MRI
    • Fain S.B., Altes T.A., Panth S.R., et al. Detection of age-dependent changes in healthy adult lungs with diffusion-weighted 3He MRI. Acad Radiol 2005, 12(11):1385-1393.
    • (2005) Acad Radiol , vol.12 , Issue.11 , pp. 1385-1393
    • Fain, S.B.1    Altes, T.A.2    Panth, S.R.3
  • 41
    • 67651229631 scopus 로고    scopus 로고
    • Validity of apparent diffusion coefficient hyperpolarized 3He-MRI using MSCT and pulmonary function tests as references
    • Diaz S., Casselbrant I., Piitulainen E., et al. Validity of apparent diffusion coefficient hyperpolarized 3He-MRI using MSCT and pulmonary function tests as references. Eur J Radiol 2009, 71(2):257-263.
    • (2009) Eur J Radiol , vol.71 , Issue.2 , pp. 257-263
    • Diaz, S.1    Casselbrant, I.2    Piitulainen, E.3
  • 42
    • 0019291109 scopus 로고
    • Solubility of inert gases in biological fluids and tissues: a review
    • Weathersby P.K., Homer L.D. Solubility of inert gases in biological fluids and tissues: a review. Undersea Biomed Res 1980, 7(4):277-296.
    • (1980) Undersea Biomed Res , vol.7 , Issue.4 , pp. 277-296
    • Weathersby, P.K.1    Homer, L.D.2
  • 44
    • 0033822157 scopus 로고    scopus 로고
    • Probing lung physiology with xenon polarization transfer contrast (XTC)
    • Ruppert K., Brookeman J.R., Hagspiel K.D., et al. Probing lung physiology with xenon polarization transfer contrast (XTC). Magn Reson Med 2000, 44(3):349-357.
    • (2000) Magn Reson Med , vol.44 , Issue.3 , pp. 349-357
    • Ruppert, K.1    Brookeman, J.R.2    Hagspiel, K.D.3
  • 45
    • 77957880663 scopus 로고    scopus 로고
    • Hyperpolarized 129Xe MR imaging of alveolar gas uptake in humans
    • Cleveland Z.I., Cofer G.P., Metz G., et al. Hyperpolarized 129Xe MR imaging of alveolar gas uptake in humans. PLoS One 2010, 5(8):e12192.
    • (2010) PLoS One , vol.5 , Issue.8 , pp. e12192
    • Cleveland, Z.I.1    Cofer, G.P.2    Metz, G.3
  • 46
    • 78650737069 scopus 로고    scopus 로고
    • Simultaneous magnetic resonance imaging of ventilation distribution and gas uptake in the human lung using hyperpolarized xenon-129
    • Mugler J.P., Altes T.A., Ruset I.C., et al. Simultaneous magnetic resonance imaging of ventilation distribution and gas uptake in the human lung using hyperpolarized xenon-129. Proc Natl Acad Sci U S A 2010, 107:21707-21712.
    • (2010) Proc Natl Acad Sci U S A , vol.107 , pp. 21707-21712
    • Mugler, J.P.1    Altes, T.A.2    Ruset, I.C.3
  • 47
    • 84892806625 scopus 로고    scopus 로고
    • Regional mapping of gas uptake by blood and tissue in the human lung using hyperpolarized xenon-129 MRI
    • Qing K., Ruppert K., Jiang Y., et al. Regional mapping of gas uptake by blood and tissue in the human lung using hyperpolarized xenon-129 MRI. JMagn Reson Imaging 2014, 39(2):346-359.
    • (2014) JMagn Reson Imaging , vol.39 , Issue.2 , pp. 346-359
    • Qing, K.1    Ruppert, K.2    Jiang, Y.3
  • 49
    • 84886795234 scopus 로고    scopus 로고
    • Optimized 3D ultrashort echo time pulmonary MRI
    • Johnson K.M., Fain S.B., Schiebler M.L., et al. Optimized 3D ultrashort echo time pulmonary MRI. Magn Reson Med 2013, 70(5):1241-1250.
    • (2013) Magn Reson Med , vol.70 , Issue.5 , pp. 1241-1250
    • Johnson, K.M.1    Fain, S.B.2    Schiebler, M.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.