메뉴 건너뛰기




Volumn 216, Issue , 2015, Pages 614-621

Development of a novel reagentless, screen-printed amperometric biosensor based on glutamate dehydrogenase and NAD+, integrated with multi-walled carbon nanotubes for the determination of glutamate in food and clinical applications

Author keywords

Keywords Amperometric glutamate biosensor Screen printed Multiwalled carbon nanotubes (MWCNTs) Reagentless

Indexed keywords

BIOSENSORS; BODY FLUIDS; ELECTROCATALYSTS; ELECTRODES; SENSITIVITY ANALYSIS; SIGNAL TO NOISE RATIO; SODIUM CHLORIDE; TRANSDUCERS; YARN;

EID: 84929158738     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2015.04.066     Document Type: Article
Times cited : (58)

References (45)
  • 1
    • 84884845794 scopus 로고    scopus 로고
    • Increased glutamate and homocysteine and decreased glutamine levels in autism: a review and strategies for future studies of amino acids in autism
    • A. Ghanizadeh Increased glutamate and homocysteine and decreased glutamine levels in autism: a review and strategies for future studies of amino acids in autism Dis. Markers 35 2013 281 286 10.1155/2013/536521
    • (2013) Dis. Markers , vol.35 , pp. 281-286
    • Ghanizadeh, A.1
  • 2
    • 0342981455 scopus 로고    scopus 로고
    • Duration of glutamate release after acute ischemic stroke
    • A. Davalos, J. Castillo, J. Serena, and M. Noya Duration of glutamate release after acute ischemic stroke Stroke 28 1997 708 710 10.1161/01.STR.28.4.708
    • (1997) Stroke , vol.28 , pp. 708-710
    • Davalos, A.1    Castillo, J.2    Serena, J.3    Noya, M.4
  • 4
    • 77953188782 scopus 로고    scopus 로고
    • Glutamatergic theories of schizophrenia
    • D.C. Javitt Glutamatergic theories of schizophrenia Isr. J. Psychiatry Relat. Sci. 47 2010 4 16
    • (2010) Isr. J. Psychiatry Relat. Sci. , vol.47 , pp. 4-16
    • Javitt, D.C.1
  • 5
    • 0346461630 scopus 로고    scopus 로고
    • Glutamate and depression: clinical and preclinical studies
    • I.A. Paul, and P. Skolnick Glutamate and depression: clinical and preclinical studies Ann. N. Y. Acad. Sci. 1003 2003 250 272
    • (2003) Ann. N. Y. Acad. Sci. , vol.1003 , pp. 250-272
    • Paul, I.A.1    Skolnick, P.2
  • 6
    • 84855594723 scopus 로고    scopus 로고
    • Application of enzyme biosensors in analysis of food and beverages
    • R. Monosik, M. Stredansky, J. Tkac, and E. Sturdik Application of enzyme biosensors in analysis of food and beverages Food Anal. Methods 5 2011 40 53 10.1007/s12161-011-9222-4
    • (2011) Food Anal. Methods , vol.5 , pp. 40-53
    • Monosik, R.1    Stredansky, M.2    Tkac, J.3    Sturdik, E.4
  • 7
    • 84907575369 scopus 로고    scopus 로고
    • Development of a disposable screen printed amperometric biosensor based on glutamate dehydrogenase, for the determination of glutamate in clinical and food applications
    • G. Hughes, R.M. Pemberton, P.R. Fielden, and J.P. Hart Development of a disposable screen printed amperometric biosensor based on glutamate dehydrogenase, for the determination of glutamate in clinical and food applications Anal. Bioanal. Electrochem. 6 2014 435 449
    • (2014) Anal. Bioanal. Electrochem. , vol.6 , pp. 435-449
    • Hughes, G.1    Pemberton, R.M.2    Fielden, P.R.3    Hart, J.P.4
  • 8
    • 14344256125 scopus 로고    scopus 로고
    • Carbon-nanotube based electrochemical biosensors: a review
    • J. Wang Carbon-nanotube based electrochemical biosensors: a review Electroanalysis 17 2005 7 14 10.1002/elan.200403113
    • (2005) Electroanalysis , vol.17 , pp. 7-14
    • Wang, J.1
  • 9
    • 4444313518 scopus 로고    scopus 로고
    • Carbon nanotube-chitosan system for electrochemical sensing based on dehydrogenase enzymes
    • M. Zhang, A. Smith, and W. Gorski Carbon nanotube-chitosan system for electrochemical sensing based on dehydrogenase enzymes Anal. Chem. 76, 2004 5045 5050 10.1021/ac049519u
    • (2004) Anal. Chem. , vol.76 , pp. 5045-5050
    • Zhang, M.1    Smith, A.2    Gorski, W.3
  • 10
    • 0001837555 scopus 로고    scopus 로고
    • Fast electron transfer kinetics on multiwalled carbon nanotube microbundle electrodes
    • J.M. Nugent, K.S.V. Santhanam, A. Rubio, and P.M. Ajayan Fast electron transfer kinetics on multiwalled carbon nanotube microbundle electrodes Nano Lett. 1 2001 87 91 10.1021/nl005521z
    • (2001) Nano Lett. , vol.1 , pp. 87-91
    • Nugent, J.M.1    Santhanam, K.S.V.2    Rubio, A.3    Ajayan, P.M.4
  • 11
    • 0034253374 scopus 로고    scopus 로고
    • Development of a disposable ethanol biosensor based on a chemically modified screen-printed electrode coated with alcohol oxidase for the analysis of beer
    • M. Boujtita, J.P. Hart, and R. Pittson Development of a disposable ethanol biosensor based on a chemically modified screen-printed electrode coated with alcohol oxidase for the analysis of beer Biosens. Bioelectron. 15 2000 257 263
    • (2000) Biosens. Bioelectron. , vol.15 , pp. 257-263
    • Boujtita, M.1    Hart, J.P.2    Pittson, R.3
  • 12
    • 34248590308 scopus 로고    scopus 로고
    • Amperometric biosensor for lactate based on lactate dehydrogenase and Meldola Blue coimmobilized on multi-wall carbon-nanotube
    • A.C. Pereira, M.R. Aguiar, A. Kisner, D.V. Macedo, and L.T. Kubota Amperometric biosensor for lactate based on lactate dehydrogenase and Meldola Blue coimmobilized on multi-wall carbon-nanotube Sens. Actuators B: Chem. 124 2007 269 276 10.1016/j.snb.2006.12.042
    • (2007) Sens. Actuators B: Chem. , vol.124 , pp. 269-276
    • Pereira, A.C.1    Aguiar, M.R.2    Kisner, A.3    Macedo, D.V.4    Kubota, L.T.5
  • 13
    • 33947589671 scopus 로고    scopus 로고
    • Electrocatalytic oxidation of NADH with Meldola's blue functionalized carbon nanotubes electrodes
    • L. Zhu, J. Zhai, R. Yang, C. Tian, and L. Guo Electrocatalytic oxidation of NADH with Meldola's blue functionalized carbon nanotubes electrodes Biosens. Bioelectron. 22 11 2007 2768 2773
    • (2007) Biosens. Bioelectron. , vol.22 , Issue.11 , pp. 2768-2773
    • Zhu, L.1    Zhai, J.2    Yang, R.3    Tian, C.4    Guo, L.5
  • 14
    • 37049089624 scopus 로고
    • Development of a disposable amperometric sensor for reduced nicotinamide adenine dinucleotide based on a chemically modified screen-printed carbon electrode
    • S.D. Sprules, J.P. Hart, S.A. Wring, and R. Pittson Development of a disposable amperometric sensor for reduced nicotinamide adenine dinucleotide based on a chemically modified screen-printed carbon electrode Analyst 119 1994 253 10.1039/an9941900253
    • (1994) Analyst , vol.119 , pp. 253
    • Sprules, S.D.1    Hart, J.P.2    Wring, S.A.3    Pittson, R.4
  • 15
    • 84872959506 scopus 로고    scopus 로고
    • Potential applications of chitosan nanoparticles as novel support in enzyme immobilization
    • H.J. Malmiri, M. Ali, G. Jahanian, and A. Berenjian Potential applications of chitosan nanoparticles as novel support in enzyme immobilization Am. J. Biochem. Biotechnol 8 2012 203 219 10.3844/ajbbsp.2012.203.219
    • (2012) Am. J. Biochem. Biotechnol , vol.8 , pp. 203-219
    • Malmiri, H.J.1    Ali, M.2    Jahanian, G.3    Berenjian, A.4
  • 16
    • 30144439606 scopus 로고    scopus 로고
    • Composite film of carbon nanotubes and chitosan for preparation of amperometric hydrogen peroxide biosensor
    • L. Qian, and X. Yang Composite film of carbon nanotubes and chitosan for preparation of amperometric hydrogen peroxide biosensor Talanta 68 2006 721 727 10.1016/j.talanta.2005.05.030
    • (2006) Talanta , vol.68 , pp. 721-727
    • Qian, L.1    Yang, X.2
  • 17
    • 84887838559 scopus 로고    scopus 로고
    • Dispersion of carbon nanotubes in water and non-aqueous solvents
    • O.V. Kharissova, B.I. Kharisov, and E.G. de Casas Ortiz Dispersion of carbon nanotubes in water and non-aqueous solvents RSC Adv. 3 2013 24812 10.1039/c3ra43852j
    • (2013) RSC Adv. , vol.3 , pp. 24812
    • Kharissova, O.V.1    Kharisov, B.I.2    De Casas Ortiz, E.G.3
  • 18
    • 33947432432 scopus 로고    scopus 로고
    • Coimmobilization of dehydrogenases and their cofactors in electrochemical biosensors
    • M. Zhang, C. Mullens, and W. Gorski Coimmobilization of dehydrogenases and their cofactors in electrochemical biosensors Anal. Chem. 79 2007 2446 2450 10.1021/ac061698n
    • (2007) Anal. Chem. , vol.79 , pp. 2446-2450
    • Zhang, M.1    Mullens, C.2    Gorski, W.3
  • 19
    • 33845462132 scopus 로고    scopus 로고
    • Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode
    • B.-Y. Wu, S.-H. Hou, F. Yin, J. Li, Z.-X. Zhao, J.-D. Huang, and Q. Chen Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode Biosens. Bioelectron. 22 2007 838 844 10.1016/j.bios.2006.03.009
    • (2007) Biosens. Bioelectron. , vol.22 , pp. 838-844
    • Wu, B.-Y.1    Hou, S.-H.2    Yin, F.3    Li, J.4    Zhao, Z.-X.5    Huang, J.-D.6    Chen, Q.7
  • 20
    • 32644489486 scopus 로고    scopus 로고
    • Multilayer membranes for glucose biosensing via layer-by-layer assembly of multiwall carbon nanotubes and glucose oxidase
    • H. Zhao, and H. Ju Multilayer membranes for glucose biosensing via layer-by-layer assembly of multiwall carbon nanotubes and glucose oxidase Anal. Biochem. 350 2006 138 144 10.1016/j.ab.2005.11.034
    • (2006) Anal. Biochem. , vol.350 , pp. 138-144
    • Zhao, H.1    Ju, H.2
  • 21
    • 79960454519 scopus 로고    scopus 로고
    • Reagentless biosensor based on layer-by-layer assembly of functional multiwall carbon nanotubes and enzyme-mediator biocomposite
    • X. Zhou, F. Xi, Y. Zhang, and X. Lin Reagentless biosensor based on layer-by-layer assembly of functional multiwall carbon nanotubes and enzyme-mediator biocomposite J. Zhejiang Univ. Sci. B 12 2011 468 476 10.1631/jzus.B1000280
    • (2011) J. Zhejiang Univ. Sci. B , vol.12 , pp. 468-476
    • Zhou, X.1    Xi, F.2    Zhang, Y.3    Lin, X.4
  • 22
    • 34347225594 scopus 로고    scopus 로고
    • Layer-by-layer assembly as a versatile bottom-up nanofabrication technique for exploratory research and realistic application
    • K. Ariga, J.P. Hill, and Q. Ji Layer-by-layer assembly as a versatile bottom-up nanofabrication technique for exploratory research and realistic application Phys. Chem. Chem. Phys. 9 2007 2319 2340 10.1039/b700410a
    • (2007) Phys. Chem. Chem. Phys. , vol.9 , pp. 2319-2340
    • Ariga, K.1    Hill, J.P.2    Ji, Q.3
  • 25
    • 77952550269 scopus 로고    scopus 로고
    • An investigation on dispersion of carbon nanotubes in chitosan aqueous solutions
    • Y.-T. Shieh, H.-M. Wu, Y.-K. Twu, and Y.-C. Chung An investigation on dispersion of carbon nanotubes in chitosan aqueous solutions Colloid Polym. Sci. 288 2009 377 385 10.1007/s00396-009-2126-9
    • (2009) Colloid Polym. Sci. , vol.288 , pp. 377-385
    • Shieh, Y.-T.1    Wu, H.-M.2    Twu, Y.-K.3    Chung, Y.-C.4
  • 26
    • 70450252140 scopus 로고    scopus 로고
    • A flow injection system, comprising a biosensor based on a screen-printed carbon electrode containing Meldola's Blue-Reinecke salt coated with glucose dehydrogenase, for the measurement of glucose
    • M. Piano, S. Serban, N. Biddle, R. Pittson, G.A. Drago, and J.P. Hart A flow injection system, comprising a biosensor based on a screen-printed carbon electrode containing Meldola's Blue-Reinecke salt coated with glucose dehydrogenase, for the measurement of glucose Anal. Biochem. 396 2010 269 274 10.1016/j.ab.2009.09.028
    • (2010) Anal. Biochem. , vol.396 , pp. 269-274
    • Piano, M.1    Serban, S.2    Biddle, N.3    Pittson, R.4    Drago, G.A.5    Hart, J.P.6
  • 27
    • 84856218784 scopus 로고    scopus 로고
    • Optical biosensor test strip for the screening and direct determination of l-glutamate in food samples
    • N.Z. Md Muslim, M. Ahmad, L.Y. Heng, and B. Saad Optical biosensor test strip for the screening and direct determination of l-glutamate in food samples Sens. Actuators B: Chem. 161 2012 493 497 10.1016/j.snb.2011.10.066
    • (2012) Sens. Actuators B: Chem. , vol.161 , pp. 493-497
    • Md Muslim, N.Z.1    Ahmad, M.2    Heng, L.Y.3    Saad, B.4
  • 28
    • 77955887323 scopus 로고    scopus 로고
    • Analysis of monosodium l-glutamate in food products by high-performance thin layer chromatography
    • V.N. Krishna, D. Karthika, D.M. Surya, M. Rubini, M. Vishalini, and Y. Pradeepa Analysis of monosodium l-glutamate in food products by high-performance thin layer chromatography J. Young Pharm. 2 2010 297 300 10.4103/0975-1483.66795
    • (2010) J. Young Pharm. , vol.2 , pp. 297-300
    • Krishna, V.N.1    Karthika, D.2    Surya, D.M.3    Rubini, M.4    Vishalini, M.5    Pradeepa, Y.6
  • 29
    • 0032032480 scopus 로고    scopus 로고
    • Astrocytes protect neurons from neurotoxic injury by serum glutamate
    • Z.C. Ye, and H. Sontheimer Astrocytes protect neurons from neurotoxic injury by serum glutamate Glia 22 1998 237 248
    • (1998) Glia , vol.22 , pp. 237-248
    • Ye, Z.C.1    Sontheimer, H.2
  • 30
    • 0031440427 scopus 로고    scopus 로고
    • Amperometric glutamate biosensor based on poly(o-phenylenediamine) film electrogenerated onto modified carbon paste electrodes
    • S.L. Alvarez-Crespo, M.J. Lobo-Castañón, A.J. Miranda-Ordieres, and P. Tuñón-Blanco Amperometric glutamate biosensor based on poly(o-phenylenediamine) film electrogenerated onto modified carbon paste electrodes Biosens. Bioelectron. 12 1997 739 747 10.1016/S0956-5663(97)00041-9
    • (1997) Biosens. Bioelectron. , vol.12 , pp. 739-747
    • Alvarez-Crespo, S.L.1    Lobo-Castañón, M.J.2    Miranda-Ordieres, A.J.3    Tuñón-Blanco, P.4
  • 31
    • 0032191658 scopus 로고    scopus 로고
    • High-throughput flow-injection analysis of glucose and glutamate in food and biological samples by using enzyme/polyion complex-bilayer membrane-based electrodes as the detectors
    • F. Mizutani, Y. Sato, Y. Hirata, and S. Yabuki High-throughput flow-injection analysis of glucose and glutamate in food and biological samples by using enzyme/polyion complex-bilayer membrane-based electrodes as the detectors Biosens. Bioelectron. 13 1998 809 815 10.1016/S0956-5663(98)00046-3
    • (1998) Biosens. Bioelectron. , vol.13 , pp. 809-815
    • Mizutani, F.1    Sato, Y.2    Hirata, Y.3    Yabuki, S.4
  • 32
    • 0033068168 scopus 로고    scopus 로고
    • Characterisation of a thermophilic l-glutamate dehydrogenase biosensor for amperometric determination of l-glutamate by flow injection analysis
    • N. Pasco, C. Jeffries, Q. Davies, A.J. Downard, A.D. Roddick-Lanzilotta, and L. Gorton Characterisation of a thermophilic l-glutamate dehydrogenase biosensor for amperometric determination of l-glutamate by flow injection analysis Biosens. Bioelectron. 14 1999 171 178 10.1016/S0956-5663(98)00120-1
    • (1999) Biosens. Bioelectron. , vol.14 , pp. 171-178
    • Pasco, N.1    Jeffries, C.2    Davies, Q.3    Downard, A.J.4    Roddick-Lanzilotta, A.D.5    Gorton, L.6
  • 33
    • 33846442796 scopus 로고    scopus 로고
    • Ultramicrobiosensor for the selective detection of glutamate
    • O.M. Schuvailo, S. Gáspár, A.P. Soldatkin, and E. Csöregi Ultramicrobiosensor for the selective detection of glutamate Electroanalysis 19 2007 71 78 10.1002/elan.200603707
    • (2007) Electroanalysis , vol.19 , pp. 71-78
    • Schuvailo, O.M.1    Gáspár, S.2    Soldatkin, A.P.3    Csöregi, E.4
  • 34
    • 22044446984 scopus 로고    scopus 로고
    • Sequential fluorometric quantification of γ-aminobutyrate and l-glutamate using a single line flow-injection system with immobilized-enzyme reactors
    • T. Tsukatani, and K. Matsumoto Sequential fluorometric quantification of γ-aminobutyrate and l-glutamate using a single line flow-injection system with immobilized-enzyme reactors Anal. Chim. Acta 546 2005 154 160 10.1016/j.aca.2005.05.053
    • (2005) Anal. Chim. Acta , vol.546 , pp. 154-160
    • Tsukatani, T.1    Matsumoto, K.2
  • 35
    • 0028977920 scopus 로고
    • l-Glutamate biosensor using a novel l-glutamate oxidase and its application to flow injection analysis system
    • B.-C. Ye, Q.-S. Li, Y.-R. Li, X.-B. Li, and J.-T. Yu l-Glutamate biosensor using a novel l-glutamate oxidase and its application to flow injection analysis system J. Biotechnol. 42 1995 45 52 10.1016/0168-1656(95)00058-X
    • (1995) J. Biotechnol. , vol.42 , pp. 45-52
    • Ye, B.-C.1    Li, Q.-S.2    Li, Y.-R.3    Li, X.-B.4    Yu, J.-T.5
  • 36
    • 84875050881 scopus 로고    scopus 로고
    • A biosensor utilizing l-glutamate dehydrogenase and diaphorase immobilized on nanocomposite electrode for determination of l-glutamate in food samples
    • R. Monošík, M. Stread'anský, E. Šturdík, A biosensor utilizing l-glutamate dehydrogenase and diaphorase immobilized on nanocomposite electrode for determination of l-glutamate in food samples Food Anal. Methods 6 2013 521 527 10.1007/s12161-012-9468-5
    • (2013) Food Anal. Methods , vol.6 , pp. 521-527
    • Monošík, R.1    Stread'anský, M.2    Šturdík, E.3
  • 37
    • 70349847690 scopus 로고    scopus 로고
    • Electrochemical sensing of NADH and glutamate based on Meldola Blue in 1,2-diaminobenzene and 3,4-ethylenedioxythiophene polymer films
    • R. Doaga, T. McCormac, and E. Dempsey Electrochemical sensing of NADH and glutamate based on Meldola Blue in 1,2-diaminobenzene and 3,4-ethylenedioxythiophene polymer films Electroanalysis 21 2009 2099 2108 10.1002/elan.200904627
    • (2009) Electroanalysis , vol.21 , pp. 2099-2108
    • Doaga, R.1    McCormac, T.2    Dempsey, E.3
  • 38
    • 0041878432 scopus 로고    scopus 로고
    • Ceramic-based multisite microelectrode arrays for in vivo electrochemical recordings of glutamate and other neurochemicals
    • J.J. Burmeister, and G.A. Gerhardt Ceramic-based multisite microelectrode arrays for in vivo electrochemical recordings of glutamate and other neurochemicals TrAC Trends Anal. Chem. 22 2003 498 502 10.1016/S0165-9936(03)00904-X
    • (2003) TrAC Trends Anal. Chem. , vol.22 , pp. 498-502
    • Burmeister, J.J.1    Gerhardt, G.A.2
  • 40
    • 0028070195 scopus 로고
    • Direct measurement of glutamate release in the brain using a dual enzyme-based electrochemical sensor
    • Y. Hu, K.M. Mitchell, F.N. Albahadily, E.K. Michaelis, and G.S. Wilson Direct measurement of glutamate release in the brain using a dual enzyme-based electrochemical sensor Brain Res. 659 1994 117 125 10.1016/0006-8993(94)90870-2
    • (1994) Brain Res. , vol.659 , pp. 117-125
    • Hu, Y.1    Mitchell, K.M.2    Albahadily, F.N.3    Michaelis, E.K.4    Wilson, G.S.5
  • 43
    • 65749098398 scopus 로고    scopus 로고
    • A microelectrode biosensor for real time monitoring of l-glutamate release
    • F. Tian, A.V. Gourine, R.T.R. Huckstepp, and N. Dale A microelectrode biosensor for real time monitoring of l-glutamate release Anal. Chim. Acta 645 2009 86 91 10.1016/j.aca.2009.04.048
    • (2009) Anal. Chim. Acta , vol.645 , pp. 86-91
    • Tian, F.1    Gourine, A.V.2    Huckstepp, R.T.R.3    Dale, N.4
  • 44
    • 50849131951 scopus 로고    scopus 로고
    • Silicon wafer-based platinum microelectrode array biosensor for near real-time measurement of glutamate in vivo
    • K.M. Wassum, V.M. Tolosa, J. Wang, E. Walker, H.G. Monbouquette, and N.T. Maidment Silicon wafer-based platinum microelectrode array biosensor for near real-time measurement of glutamate in vivo Sensors 8 2008 5023 5036 10.3390/s8085023
    • (2008) Sensors , vol.8 , pp. 5023-5036
    • Wassum, K.M.1    Tolosa, V.M.2    Wang, J.3    Walker, E.4    Monbouquette, H.G.5    Maidment, N.T.6
  • 45
    • 33750286984 scopus 로고    scopus 로고
    • In vivo monitoring of extracellular glutamate in the brain with a microsensor
    • W.H. Oldenziel, G. Dijkstra, T.I.F.H. Cremers, and B.H.C. Westerink In vivo monitoring of extracellular glutamate in the brain with a microsensor Brain Res. 1118 2006 34 42 10.1016/j.brainres.2006.08.015
    • (2006) Brain Res. , vol.1118 , pp. 34-42
    • Oldenziel, W.H.1    Dijkstra, G.2    Cremers, T.I.F.H.3    Westerink, B.H.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.