메뉴 건너뛰기




Volumn 15, Issue 5-6, 2000, Pages 257-263

Development of a disposable ethanol biosensor based on a chemically modified screen-printed electrode coated with alcohol oxidase for the analysis of beer

Author keywords

Amperometry; Beer; Biosensor; Chronoamperometry; Ethanol; Screen printed

Indexed keywords

AMPEROMETRIC SENSORS; ELECTRODES; ENZYME KINETICS; ETHANOL; GAS PERMEABLE MEMBRANES;

EID: 0034253374     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(00)00075-0     Document Type: Article
Times cited : (116)

References (30)
  • 1
    • 0029161190 scopus 로고
    • Biosensors for analysis of ethanol in food
    • Boujtita M., El Murr N. Biosensors for analysis of ethanol in food. J. Food Sci. 60:1995;201-204.
    • (1995) J. Food Sci. , vol.60 , pp. 201-204
    • Boujtita, M.1    El Murr, N.2
  • 2
    • 0030051157 scopus 로고    scopus 로고
    • Biosensors for analysis of ethanol in food: Effect of the pasting liquid
    • Boujtita M., El Murr N. Biosensors for analysis of ethanol in food: effect of the pasting liquid. Anal. Chim. Acta. 319:1996;91-96.
    • (1996) Anal. Chim. Acta , vol.319 , pp. 91-96
    • Boujtita, M.1    El Murr, N.2
  • 3
    • 0030992998 scopus 로고    scopus 로고
    • Amperometric biosensor for ethanol based on immobilisation of alcohol dehydrogenase on a nickel hexacyanoferrate modified microband gold electrode
    • Cai C.X., Xue K.H., Zhou Y.M., Yang H. Amperometric biosensor for ethanol based on immobilisation of alcohol dehydrogenase on a nickel hexacyanoferrate modified microband gold electrode. Talanta. 44:1997;339-347.
    • (1997) Talanta , vol.44 , pp. 339-347
    • Cai, C.X.1    Xue, K.H.2    Zhou, Y.M.3    Yang, H.4
  • 4
    • 0030871664 scopus 로고    scopus 로고
    • Amperometric detection of ethanol with poly-(o-phenylenediamine)-modified enzyme electrodes
    • Castanon M.J.L., Ordieres A.J.M., Blanco P.T. Amperometric detection of ethanol with poly-(o-phenylenediamine)-modified enzyme electrodes. Biosens. Bioelectr. 12:1997;511-520.
    • (1997) Biosens. Bioelectr. , vol.12 , pp. 511-520
    • Castanon, M.J.L.1    Ordieres, A.J.M.2    Blanco, P.T.3
  • 5
    • 84987277560 scopus 로고
    • Determination of ethanol in beer by direct injection gas chromatography. A comparison of 6 identical systems
    • Clarkson S.P., Onnrod I.H.L., Sharpe F.R. Determination of ethanol in beer by direct injection gas chromatography. A comparison of 6 identical systems. J. Inst. Brew. 101:1995;191-193.
    • (1995) J. Inst. Brew. , vol.101 , pp. 191-193
    • Clarkson, S.P.1    Onnrod, I.H.L.2    Sharpe, F.R.3
  • 6
    • 0030480210 scopus 로고    scopus 로고
    • Direct monitoring of formaldehyde vapour and detection of ethanol vapour by using dehydrogenase-based biosensors
    • Dennison M.J., Hall J.M., Turner A.P.F. Direct monitoring of formaldehyde vapour and detection of ethanol vapour by using dehydrogenase-based biosensors. Analyst. 121:1996;1769-1773.
    • (1996) Analyst , vol.121 , pp. 1769-1773
    • Dennison, M.J.1    Hall, J.M.2    Turner, A.P.F.3
  • 7
    • 0027283752 scopus 로고
    • Reagentless chemically modified carbon paste electrodes based on phenazine polymer derivative and yeast alcohol dehydrogenase for the analysis of ethanol
    • Domingues E., Lan H.L., Okamato Y., Hale P.D., Skotheim T.A., Gorton L., Hahn-Hagerdal B. Reagentless chemically modified carbon paste electrodes based on phenazine polymer derivative and yeast alcohol dehydrogenase for the analysis of ethanol. Biosens. Bioelectr. 8:1993;229-237.
    • (1993) Biosens. Bioelectr. , vol.8 , pp. 229-237
    • Domingues, E.1    Lan, H.L.2    Okamato, Y.3    Hale, P.D.4    Skotheim, T.A.5    Gorton, L.6    Hahn-Hagerdal, B.7
  • 9
    • 0028313712 scopus 로고
    • Fabrication and characterisation, of a screen-printed, disposable, amperometric cholesterol biosensor
    • Gilmartin M.A.T., Hart J.P. Fabrication and characterisation, of a screen-printed, disposable, amperometric cholesterol biosensor. Analyst. 119:1994;2331-2336.
    • (1994) Analyst , vol.119 , pp. 2331-2336
    • Gilmartin, M.A.T.1    Hart, J.P.2
  • 10
    • 0028891593 scopus 로고
    • Prototype, solid-phase, glucose biosensor
    • Gilmartin M.A.T., Hart J.P., Patton D.T. Prototype, solid-phase, glucose biosensor. Analyst. 120:1995;1973-1981.
    • (1995) Analyst , vol.120 , pp. 1973-1981
    • Gilmartin, M.A.T.1    Hart, J.P.2    Patton, D.T.3
  • 11
    • 0001149614 scopus 로고
    • Development of an amperometric sensor for uric acid based on chemically modified graphite-epoxy resin and screen-printed electrodes containing cobalt phthalocyanine
    • Gilmartin M.A.T., Birch B.J., Hart J.P. Development of an amperometric sensor for uric acid based on chemically modified graphite-epoxy resin and screen-printed electrodes containing cobalt phthalocyanine. Analyst. 119:1994;243-252.
    • (1994) Analyst , vol.119 , pp. 243-252
    • Gilmartin, M.A.T.1    Birch, B.J.2    Hart, J.P.3
  • 12
    • 84988080206 scopus 로고
    • Volametric and Photoelectron spectral elucidation of the electrocatalytic oxidation of hydrogen peroxide at screen-printed carbon electrodes chemically modified with cobalt phthalocyanine
    • Gilmartin M.A.T., Ewen R.J, Hart J.P., Honeybourne C.L. Volametric and Photoelectron spectral elucidation of the electrocatalytic oxidation of hydrogen peroxide at screen-printed carbon electrodes chemically modified with cobalt phthalocyanine. Electroanalysis. 7:1994;547-555.
    • (1994) Electroanalysis , vol.7 , pp. 547-555
    • Gilmartin, M.A.T.1    Ewen, R.J.2    Hart, J.P.3    Honeybourne, C.L.4
  • 13
    • 84987486818 scopus 로고
    • New amperometric dehydrogenase electrodes based on electrocatalytic NADH-oxidation at polymethylene blue-modified electrodes
    • Karyakin A.A., Katyakina E.E., Schuhmann W., Schmidt H.L., Varfolomeyev E.D. New amperometric dehydrogenase electrodes based on electrocatalytic NADH-oxidation at polymethylene blue-modified electrodes. Electroanalysis. 6:1994;821-829.
    • (1994) Electroanalysis , vol.6 , pp. 821-829
    • Karyakin, A.A.1    Katyakina, E.E.2    Schuhmann, W.3    Schmidt, H.L.4    Varfolomeyev, E.D.5
  • 15
    • 84963154768 scopus 로고
    • Reagentless biosensors for substrates of dehydrogenases
    • Kulis J.J., Bilitewski U., Schmid R.D. Reagentless biosensors for substrates of dehydrogenases. Anal. Lett. 24:1991;181-189.
    • (1991) Anal. Lett. , vol.24 , pp. 181-189
    • Kulis, J.J.1    Bilitewski, U.2    Schmid, R.D.3
  • 16
    • 0031459666 scopus 로고    scopus 로고
    • Reagentless ethanol sensor based on a NAD-dependent dehydrogenase
    • Leca B., Marty J.L.S. Reagentless ethanol sensor based on a NAD-dependent dehydrogenase. Biosens. Bioelectr. 12:1997;1083-1088.
    • (1997) Biosens. Bioelectr. , vol.12 , pp. 1083-1088
    • Leca, B.1    Marty, J.L.S.2
  • 17
    • 0030979101 scopus 로고    scopus 로고
    • Reusable ethanol sensor based on NAD(+)-dependent dehydrogenase without coenzyme addition
    • Leca B., Marty J.L.S. Reusable ethanol sensor based on NAD(+)-dependent dehydrogenase without coenzyme addition. Anal. Chim. Acta. 340:1997;143148.
    • (1997) Anal. Chim. Acta , vol.340 , pp. 143148
    • Leca, B.1    Marty, J.L.S.2
  • 18
    • 0032422809 scopus 로고    scopus 로고
    • Rapid alcohol determination in plasma and urine by column liquid chromatography with biosensor detection
    • Liden H., Vijayakumar A.R., Gorton L., Marko Varga G. Rapid alcohol determination in plasma and urine by column liquid chromatography with biosensor detection. J. Pharm. Biomed. Anal. 17:1998;1111-1128.
    • (1998) J. Pharm. Biomed. Anal. , vol.17 , pp. 1111-1128
    • Liden, H.1    Vijayakumar, A.R.2    Gorton, L.3    Marko Varga, G.4
  • 19
    • 0010591895 scopus 로고    scopus 로고
    • Flow injection analysis of ethanol with alcohol dehydrogenase-modified carbon paste electrode
    • Lobo M.J., Miranda A.J., Tunob P. Flow injection analysis of ethanol with alcohol dehydrogenase-modified carbon paste electrode. Electroanalysis. 8:1996;932-937.
    • (1996) Electroanalysis , vol.8 , pp. 932-937
    • Lobo, M.J.1    Miranda, A.J.2    Tunob, P.3
  • 20
    • 0028031787 scopus 로고
    • Enzyme-based biosensor as a selective detection unit in column liquid-chromatography
    • Markovarga G., Johansson K., Gorton L. Enzyme-based biosensor as a selective detection unit in column liquid-chromatography. J. Chromatogr. 660:1994;153-167.
    • (1994) J. Chromatogr. , vol.660 , pp. 153-167
    • Markovarga, G.1    Johansson, K.2    Gorton, L.3
  • 22
    • 0030595014 scopus 로고    scopus 로고
    • A disposable reagent-less screen-printed amperometric biosensor for measurement of alcohol in beverages
    • Sprules S.D., Hartley I.C., Wedge R., Hart J.P., Pittson R. A disposable reagent-less screen-printed amperometric biosensor for measurement of alcohol in beverages. Anal. Chim. Acta. 329:1996;215-221.
    • (1996) Anal. Chim. Acta , vol.329 , pp. 215-221
    • Sprules, S.D.1    Hartley, I.C.2    Wedge, R.3    Hart, J.P.4    Pittson, R.5
  • 23
    • 0031172550 scopus 로고    scopus 로고
    • Monitoring of the glucose concentration during microbial fermentation using a novel mass-producible biosensor suitable
    • Tothill I.E., Newman J.D., White S.F., Turner A.P.F. Monitoring of the glucose concentration during microbial fermentation using a novel mass-producible biosensor suitable. Enzyme Microb. Technol. 20:1997;590-596.
    • (1997) Enzyme Microb. Technol. , vol.20 , pp. 590-596
    • Tothill, I.E.1    Newman, J.D.2    White, S.F.3    Turner, A.P.F.4
  • 24
    • 0342569274 scopus 로고    scopus 로고
    • Biosensors: Realities and aspirations
    • Turner A.P.F. Biosensors: realities and aspirations. Annali di. 87:1997;255-260.
    • (1997) Annali di , vol.87 , pp. 255-260
    • Turner, A.P.F.1
  • 25
    • 0030578372 scopus 로고    scopus 로고
    • Alcohol biosensors based on coupled oxidase-peroxidase systems
    • Vijayakumar A.R., Csoregi E., Heller A., Gorton L. Alcohol biosensors based on coupled oxidase-peroxidase systems. Anal. Chim. Acta. 327:1996;223-234.
    • (1996) Anal. Chim. Acta , vol.327 , pp. 223-234
    • Vijayakumar, A.R.1    Csoregi, E.2    Heller, A.3    Gorton, L.4
  • 26
    • 0002224569 scopus 로고    scopus 로고
    • Sol-gel-derived metal dispersed carbon composite amperometric
    • Wang J., Pamidi P.V.A., Park D.S. Sol-gel-derived metal dispersed carbon composite amperometric. Electroanalysis. 9:1997;52-55.
    • (1997) Electroanalysis , vol.9 , pp. 52-55
    • Wang, J.1    Pamidi, P.V.A.2    Park, D.S.3
  • 28
    • 0024990065 scopus 로고
    • Development of screen-printed carbon electrodes, chemically modified with cobalt phthalocyanine, for electrochemical sensor applications
    • Wring S.A., Hart J.P. Development of screen-printed carbon electrodes, chemically modified with cobalt phthalocyanine, for electrochemical sensor applications. Anal. Chim. Acta. 231:1990;203-212.
    • (1990) Anal. Chim. Acta , vol.231 , pp. 203-212
    • Wring, S.A.1    Hart, J.P.2
  • 29
    • 37049072577 scopus 로고
    • Chemically modified, screen-printed carbon electrodes
    • Wring S.A., Hart J.P. Chemically modified, screen-printed carbon electrodes. Analyst. 117:1992;1281-1285.
    • (1992) Analyst , vol.117 , pp. 1281-1285
    • Wring, S.A.1    Hart, J.P.2
  • 30
    • 0030607676 scopus 로고    scopus 로고
    • Electrochemical characteristics of carbon-based thick-film L-lactate biosensor using L-lactate dehydrogenase
    • Yoon H.C., Kim H.S. Electrochemical characteristics of carbon-based thick-film L-lactate biosensor using L-lactate dehydrogenase. Anal. Chim. Acta. 336:1996;57-65.
    • (1996) Anal. Chim. Acta , vol.336 , pp. 57-65
    • Yoon, H.C.1    Kim, H.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.