Intraoperative navigation of patient-specific instrumentation does not predict final implant position

Author keywords

Femoral rotation; Intraoperative navigation; Mechanical axis; Patient specific instrumentation (PSI); Total knee arthroplasty (TKA)

Indexed keywords

ARTICLE; BONE IMPLANT; BONE RADIOGRAPHY; COMPUTER ASSISTED TOMOGRAPHY; HUMAN; INTRAOPERATIVE PERIOD; MAJOR CLINICAL STUDY; MEDICAL DEVICE; NUCLEAR MAGNETIC RESONANCE IMAGING; PATIENT SPECIFIC INSTRUMENTATION; POSTOPERATIVE PERIOD; PREDICTION; RETROSPECTIVE STUDY; ROTATION; SURGICAL NAVIGATION SYSTEM; TOTAL KNEE REPLACEMENT; AGED; COMPUTER ASSISTED SURGERY; DEVICES; FEMALE; FEMUR; KNEE ARTHROPLASTY; KNEE PROSTHESIS; MALE; MIDDLE AGED; PROCEDURES; SURGERY; TIBIA;

EID: 84928349176     PISSN: 08835403     EISSN: 15328406     Source Type: Journal    
DOI: 10.1016/j.arth.2014.11.005     Document Type: Article
Times cited : (10)

References (17)
  • 1
    • 84893962562 scopus 로고    scopus 로고
    • The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty
    • Chen J.Y., Yeo S.J., Yew A.K., et al. The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2014, 22(3):630.
    • (2014) Knee Surg Sports Traumatol Arthrosc , vol.22 , Issue.3 , pp. 630
    • Chen, J.Y.1    Yeo, S.J.2    Yew, A.K.3
  • 2
    • 84872051479 scopus 로고    scopus 로고
    • Patient-specific instrumentation in total knee arthroplasty: a review
    • Nam D., McArthur B.A., Cross M.B., et al. Patient-specific instrumentation in total knee arthroplasty: a review. J Knee Surg 2012, 25(3):213.
    • (2012) J Knee Surg , vol.25 , Issue.3 , pp. 213
    • Nam, D.1    McArthur, B.A.2    Cross, M.B.3
  • 3
    • 84893966138 scopus 로고    scopus 로고
    • Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement
    • Ensini A., Timoncini A., Cenni F., et al. Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement. Knee Surg Sports Traumatol Arthrosc 2014, 22(3):621.
    • (2014) Knee Surg Sports Traumatol Arthrosc , vol.22 , Issue.3 , pp. 621
    • Ensini, A.1    Timoncini, A.2    Cenni, F.3
  • 4
    • 84893979038 scopus 로고    scopus 로고
    • Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation
    • Scholes C., Sahni V., Lustig S., et al. Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation. Knee Surg Sports Traumatol Arthrosc 2014, 22(3):660.
    • (2014) Knee Surg Sports Traumatol Arthrosc , vol.22 , Issue.3 , pp. 660
    • Scholes, C.1    Sahni, V.2    Lustig, S.3
  • 5
    • 84892554100 scopus 로고    scopus 로고
    • In-vivo alignment comparing patient specific instrumentation with both conventional and computer assisted surgery (CAS) instrumentation in total knee arthroplasty
    • Barrett W., Hoeffel D., Dalury D., et al. In-vivo alignment comparing patient specific instrumentation with both conventional and computer assisted surgery (CAS) instrumentation in total knee arthroplasty. J Arthroplast 2014, 29(2):343.
    • (2014) J Arthroplast , vol.29 , Issue.2 , pp. 343
    • Barrett, W.1    Hoeffel, D.2    Dalury, D.3
  • 6
    • 84884531175 scopus 로고    scopus 로고
    • Radiographic accuracy in TKA with a CT-based patient-specific cutting block technique
    • Koch P.P., Muller D., Pisan M., et al. Radiographic accuracy in TKA with a CT-based patient-specific cutting block technique. Knee Surg Sports Traumatol Arthrosc 2013, 21(10):2200.
    • (2013) Knee Surg Sports Traumatol Arthrosc , vol.21 , Issue.10 , pp. 2200
    • Koch, P.P.1    Muller, D.2    Pisan, M.3
  • 7
    • 84874562813 scopus 로고    scopus 로고
    • Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patient-specific instrumentation for total knee arthroplasty
    • Lustig S., Scholes C.J., Oussedik S.I., et al. Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patient-specific instrumentation for total knee arthroplasty. J Arthroplast 2013, 28(3):469.
    • (2013) J Arthroplast , vol.28 , Issue.3 , pp. 469
    • Lustig, S.1    Scholes, C.J.2    Oussedik, S.I.3
  • 8
    • 84856954337 scopus 로고    scopus 로고
    • Are patient-specific cutting blocks cost-effective for total knee arthroplasty?
    • Nunley R.M., Ellison B.S., Ruh E.L., et al. Are patient-specific cutting blocks cost-effective for total knee arthroplasty?. Clin Orthop Relat Res 2012, 470(3):889.
    • (2012) Clin Orthop Relat Res , vol.470 , Issue.3 , pp. 889
    • Nunley, R.M.1    Ellison, B.S.2    Ruh, E.L.3
  • 9
    • 84856958576 scopus 로고    scopus 로고
    • Do patient-specific guides improve coronal alignment in total knee arthroplasty?
    • Nunley R.M., Ellison B.S., Zhu J., et al. Do patient-specific guides improve coronal alignment in total knee arthroplasty?. Clin Orthop Relat Res 2012, 470(3):895.
    • (2012) Clin Orthop Relat Res , vol.470 , Issue.3 , pp. 895
    • Nunley, R.M.1    Ellison, B.S.2    Zhu, J.3
  • 10
    • 84891747010 scopus 로고    scopus 로고
    • Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial
    • Victor J., Dujardin J., Vandenneucker H., et al. Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial. Clin Orthop Relat Res 2014, 472(1):263.
    • (2014) Clin Orthop Relat Res , vol.472 , Issue.1 , pp. 263
    • Victor, J.1    Dujardin, J.2    Vandenneucker, H.3
  • 11
    • 84884532902 scopus 로고    scopus 로고
    • Evaluation of the accuracy of a patient-specific instrumentation by navigation
    • Conteduca F., Iorio R., Mazza D., et al. Evaluation of the accuracy of a patient-specific instrumentation by navigation. Knee Surg Sports Traumatol Arthrosc 2013, 21(10):2194.
    • (2013) Knee Surg Sports Traumatol Arthrosc , vol.21 , Issue.10 , pp. 2194
    • Conteduca, F.1    Iorio, R.2    Mazza, D.3
  • 12
    • 37349078592 scopus 로고    scopus 로고
    • Custom-fit total knee arthroplasty (OtisKnee) results in malalignment
    • Klatt B.A., Goyal N., Austin M.S., et al. Custom-fit total knee arthroplasty (OtisKnee) results in malalignment. J Arthroplast 2008, 23(1):26.
    • (2008) J Arthroplast , vol.23 , Issue.1 , pp. 26
    • Klatt, B.A.1    Goyal, N.2    Austin, M.S.3
  • 13
    • 84908609300 scopus 로고    scopus 로고
    • Small improvements in mechanical axis alignment achieved with MRI versus CT-based patient-specific instruments in TKA: a randomized clinical trial
    • BLINDED FOR REVIEW PURPOSES ONLY
    • Pfitzner T., Abdel M.P., von Roth P., et al. Small improvements in mechanical axis alignment achieved with MRI versus CT-based patient-specific instruments in TKA: a randomized clinical trial. Clin Orthop Relat Res 2014, 472(10):2913. BLINDED FOR REVIEW PURPOSES ONLY.
    • (2014) Clin Orthop Relat Res , vol.472 , Issue.10 , pp. 2913
    • Pfitzner, T.1    Abdel, M.P.2    von Roth, P.3
  • 14
    • 0032418168 scopus 로고    scopus 로고
    • Malrotation causing patellofemoral complications after total knee arthroplasty
    • Berger R.A., Crossett L.S., Jacobs J.J., et al. Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 1998, (356):144.
    • (1998) Clin Orthop Relat Res , Issue.356 , pp. 144
    • Berger, R.A.1    Crossett, L.S.2    Jacobs, J.J.3
  • 15
    • 77956999796 scopus 로고    scopus 로고
    • Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements
    • BLINDED FOR REVIEW PURPOSES ONLY
    • Parratte S., Pagnano M.W., Trousdale R.T., et al. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg 2010, 92A:43. BLINDED FOR REVIEW PURPOSES ONLY.
    • (2010) J Bone Joint Surg , vol.92 A , pp. 43
    • Parratte, S.1    Pagnano, M.W.2    Trousdale, R.T.3
  • 16
    • 84904117420 scopus 로고    scopus 로고
    • No benefit of patient-specific instrumentation in TKA on functional and gait outcomes: a randomized clinical trial
    • BLINDED FOR REVIEW PURPOSES ONLY
    • Abdel M.P., Parratte S., Blanc G., et al. No benefit of patient-specific instrumentation in TKA on functional and gait outcomes: a randomized clinical trial. Clin Orthop Relat Res 2014, 472(8):2468. BLINDED FOR REVIEW PURPOSES ONLY.
    • (2014) Clin Orthop Relat Res , vol.472 , Issue.8 , pp. 2468
    • Abdel, M.P.1    Parratte, S.2    Blanc, G.3
  • 17
    • 85047688420 scopus 로고    scopus 로고
    • Coronal alignment in total knee replacement: historical review, contemporary analysis, and future direction
    • BLINDED FOR REVIEW PURPOSES ONLY
    • Abdel M.P., Oussedik S.I., Parratte S., et al. Coronal alignment in total knee replacement: historical review, contemporary analysis, and future direction. Bone Joint J 2014, 96B(7):857. BLINDED FOR REVIEW PURPOSES ONLY.
    • (2014) Bone Joint J , vol.96 B , Issue.7 , pp. 857
    • Abdel, M.P.1    Oussedik, S.I.2    Parratte, S.3