메뉴 건너뛰기




Volumn 179, Issue 5, 2014, Pages 497-514

Review of new topical hemostatic dressings for combat casualty care

Author keywords

[No Author keywords available]

Indexed keywords

BIOPOLYMER; CHITOSAN; HEMOSTATIC AGENT;

EID: 84926362549     PISSN: 00264075     EISSN: 1930613X     Source Type: Journal    
DOI: 10.7205/MILMED-D-13-00199     Document Type: Review
Times cited : (143)

References (76)
  • 1
    • 84871233973 scopus 로고    scopus 로고
    • Deaths on the battlefield (2001-2011): Implications for the future combat casualty care
    • Eastridge BJ, Mabry RL, Seguin P, et al: Deaths on the battlefield (2001-2011): implications for the future combat casualty care. J Trauma Acute Care Surg 2012; 73(6 Suppl 5): S431-7.
    • (2012) J Trauma Acute Care Surg , vol.73 , Issue.6 , pp. S431-S437
    • Eastridge, B.J.1    Mabry, R.L.2    Seguin, P.3
  • 2
    • 43349085680 scopus 로고    scopus 로고
    • Practical use of emergency tourniquets to stop bleeding in major limb trauma
    • Kragh JF Jr, Walters TJ, Baer DG, et al: Practical use of emergency tourniquets to stop bleeding in major limb trauma. J Trauma 2008; 64(2 Suppl): S38-49.
    • (2008) J Trauma , vol.64 , Issue.2 , pp. S38-S49
    • Kragh, J.F.1    Walters, T.J.2    Baer, D.G.3
  • 3
    • 58749084700 scopus 로고    scopus 로고
    • Survival with emergency tourniquet use to stop bleeding in major limb trauma
    • Kragh JF Jr, Walters TJ, Baer DG, et al: Survival with emergency tourniquet use to stop bleeding in major limb trauma. Ann Surg 2009; 249: 1-7.
    • (2009) Ann Surg , vol.249 , pp. 1-7
    • Kragh, J.F.1    Walters, T.J.2    Baer, D.G.3
  • 6
    • 84855544504 scopus 로고    scopus 로고
    • Evaluation of topical hemostatic agents for combat wound treatment
    • April–June
    • Kheirabadi B: Evaluation of topical hemostatic agents for combat wound treatment. US Army Med Dep J 2011; April–June: 25-37
    • (2011) US Army Med Dep J , pp. 25-37
    • Kheirabadi, B.1
  • 9
    • 84555187180 scopus 로고    scopus 로고
    • Eliminating preventable death on the battlefield
    • Kotwal RS, Montgomery HR, Kotwal BM, et al: Eliminating preventable death on the battlefield. Arch Surg 2011; 146(12): 1350-8.
    • (2011) Arch Surg , vol.146 , Issue.12 , pp. 1350-1358
    • Kotwal, R.S.1    Montgomery, H.R.2    Kotwal, B.M.3
  • 10
    • 84871239914 scopus 로고    scopus 로고
    • Military medical revolution: Prehospital combat casualty care
    • Blackbourne LH, Baer DG, Eastridge BJ, et al: Military medical revolution: prehospital combat casualty care. J Trauma Acute Care Surg 2012; 73(6 Supp 5): S372-7.
    • (2012) J Trauma Acute Care Surg , vol.73 , Issue.6 , pp. S372-S377
    • Blackbourne, L.H.1    Baer, D.G.2    Eastridge, B.J.3
  • 11
    • 67651160571 scopus 로고    scopus 로고
    • Comparison of new hemostatic granules/powders with currently deployed hemostatic products in a lethal model of extremity arterial hemorrhage in swine
    • Kheirabadi BS, Edens JW, Terrazas IB, et al: Comparison of new hemostatic granules/powders with currently deployed hemostatic products in a lethal model of extremity arterial hemorrhage in swine. J Trauma 2009; 66: 316-26.
    • (2009) J Trauma , vol.66 , pp. 316-326
    • Kheirabadi, B.S.1    Edens, J.W.2    Terrazas, I.B.3
  • 12
    • 70449103350 scopus 로고    scopus 로고
    • Determination of efficacy of new hemostatic dressings in a model of extremity arterial hemorrhage in swine
    • Kheirabadi BS, Scherer MR, Estep JS, Dubick MA, Holcomb JB: Determination of efficacy of new hemostatic dressings in a model of extremity arterial hemorrhage in swine. J Trauma 2009; 67: 450-9.
    • (2009) J Trauma , vol.67 , pp. 450-459
    • Kheirabadi, B.S.1    Scherer, M.R.2    Estep, J.S.3    Dubick, M.A.4    Holcomb, J.B.5
  • 13
    • 72449132894 scopus 로고    scopus 로고
    • Comparison of 10 hemostaticdressings in a groin transection model in swine
    • Arnaud F, Parreno-Sadalan D, Tomori T, et al: Comparison of 10 hemostaticdressings in a groin transection model in swine. J Trauma 2009; 67: 848-55.
    • (2009) J Trauma , vol.67 , pp. 848-855
    • Arnaud, F.1    Parreno-Sadalan, D.2    Tomori, T.3
  • 14
    • 68849126226 scopus 로고    scopus 로고
    • Comparison of10 hemostatic dressings in agroin puncture model in swine
    • Arnaud F, Teranishi K, Tomori T, Carr W, McCarron R: Comparison of10 hemostatic dressings in agroin puncture model in swine. J Vasc Surg 2009; 50: 632-9.
    • (2009) J Vasc Surg , vol.50 , pp. 632-639
    • Arnaud, F.1    Teranishi, K.2    Tomori, T.3    Carr, W.4    McCarron, R.5
  • 16
    • 77249170881 scopus 로고    scopus 로고
    • Safety evaluation of new hemostatic agents, smectite granules, and kaolin-coated gauze in a vascular injury wound model in swine
    • Kheirabadi BS, Mac EJE, Terrazas IB, et al: Safety evaluation of new hemostatic agents, smectite granules, and kaolin-coated gauze in a vascular injury wound model in swine. J Trauma 2010; 68: 269-78.
    • (2010) J Trauma , vol.68 , pp. 269-278
    • Kheirabadi, B.S.1    Mac, E.2    Terrazas, I.B.3
  • 17
    • 84929184262 scopus 로고    scopus 로고
    • August 03, accessed April 9, 2013
    • Schwartz R: CoTCCC meeting minutes, August 03, 2012. Available at http://www.naemt.org/education/TCCC/guidelines_curriculum.aspx; accessed April 9, 2013
    • (2012) Cotccc Meeting Minutes
    • Schwartz, R.1
  • 18
    • 79960392769 scopus 로고    scopus 로고
    • Development of a standard swine hemorrhage model for efficacy assessment of topical hemostatic agents
    • Kheirabadi BS, Arnaud F, McCarron R, et al: Development of a standard swine hemorrhage model for efficacy assessment of topical hemostatic agents. J Trauma 2011; 71: S139–46.
    • (2011) J Trauma , vol.71 , pp. S139-S146
    • Kheirabadi, B.S.1    Arnaud, F.2    McCarron, R.3
  • 19
    • 79953667794 scopus 로고    scopus 로고
    • Pre-hospital haemostatic dressings: A systematic review
    • Granville-Chapman J, Jacobs N, Midwinter MJ: Pre-hospital haemostatic dressings: a systematic review. Injury 2011; 42: 447-59
    • (2011) Injury , vol.42 , pp. 447-459
    • Granville-Chapman, J.1    Jacobs, N.2    Midwinter, M.J.3
  • 20
    • 84863708243 scopus 로고    scopus 로고
    • MRDH bandage for surgery and trauma: Data summary and comparative review
    • Valeri CR, Vournakis JN: mRDH bandage for surgery and trauma: data summary and comparative review. J Trauma 2011; 71: S162-6.
    • (2011) J Trauma , vol.71 , pp. S162-S166
    • Valeri, C.R.1    Vournakis, J.N.2
  • 21
    • 80052294682 scopus 로고    scopus 로고
    • Comparison of two packable hemostatic Gauze dressings in a porcine hemorrhage model
    • Schwartz RB, Reynolds BZ, Shiver SA, et al: Comparison of two packable hemostatic Gauze dressings in a porcine hemorrhage model. Prehosp Emerg Care 2011; 15: 477–82.
    • (2011) Prehosp Emerg Care , vol.15 , pp. 477-482
    • Schwartz, R.B.1    Reynolds, B.Z.2    Shiver, S.A.3
  • 22
    • 84989768841 scopus 로고    scopus 로고
    • A salmon thrombin-fibrinogen dressing controls hemorrhage in a swine model compared to standard kaolin-coated gauze
    • Floyd CT, Rothwell SW, Martin R, Risdahl J, Olson CE: A salmon thrombin-fibrinogen dressing controls hemorrhage in a swine model compared to standard kaolin-coated gauze. J Spec Oper Med 2012; 12(1): 49-55.
    • (2012) J Spec Oper Med , vol.12 , Issue.1 , pp. 49-55
    • Floyd, C.T.1    Rothwell, S.W.2    Martin, R.3    Risdahl, J.4    Olson, C.E.5
  • 23
    • 84926363369 scopus 로고    scopus 로고
    • Salmon thrombin-fibrinogen dressing allows greater survival and preserves distal blood flow compared to standard kaolin gauze in coagulopathic swine with a standardized lethal femoral artery injury
    • Floyd CT, Rothwell SW, Risdahl J, Martin R, Olson C, Rose N: Salmon thrombin-fibrinogen dressing allows greater survival and preserves distal blood flow compared to standard kaolin gauze in coagulopathic swine with a standardized lethal femoral artery injury. J Spec Oper Med 2012; 12(2): 16-26.
    • (2012) J Spec Oper Med , vol.12 , Issue.2 , pp. 16-26
    • Floyd, C.T.1    Rothwell, S.W.2    Risdahl, J.3    Martin, R.4    Olson, C.5    Rose, N.6
  • 24
    • 24644457287 scopus 로고    scopus 로고
    • A salmon thrombin-fibrin bandage controls arterial bleeding in a swine aortotomy model
    • Rothwell SW, Reid TJ, Dorsey J, et al: A salmon thrombin-fibrin bandage controls arterial bleeding in a swine aortotomy model. J Trauma 2005; 59(1): 143–9.
    • (2005) J Trauma , vol.59 , Issue.1 , pp. 143-149
    • Rothwell, S.W.1    Reid, T.J.2    Dorsey, J.3
  • 25
    • 20744451317 scopus 로고    scopus 로고
    • Biomedical application of chitin, chitosan, and their derivatives
    • Singh DK, Ray AR: Biomedical application of chitin, chitosan, and their derivatives. Polymer Rev 2000; 40: 69-83.
    • (2000) Polymer Rev , vol.40 , pp. 69-83
    • Singh, D.K.1    Ray, A.R.2
  • 27
    • 68449083191 scopus 로고    scopus 로고
    • Functional characterization of chitin and chitosan
    • Aranaz I, Mengibar N, Harris R, et al: Functional characterization of chitin and chitosan. Curr Chem Biol 2009; 3: 203–30.
    • (2009) Curr Chem Biol , vol.3 , pp. 203-230
    • Aranaz, I.1    Mengibar, N.2    Harris, R.3
  • 28
    • 0026749078 scopus 로고
    • Studies on chitosan: 4. Lysozymic hydrolysis of partially N-acetylated chitosans
    • Aiba S: Studies on chitosan: 4. Lysozymic hydrolysis of partially N-acetylated chitosans. Int J Biol Macromol 1992; 14: 225-28
    • (1992) Int J Biol Macromol , vol.14 , pp. 225-228
    • Aiba, S.1
  • 29
    • 77249111686 scopus 로고    scopus 로고
    • The safety of chitosan as a pharmaceutical excipient
    • Baldrick P: The safety of chitosan as a pharmaceutical excipient. Regul Toxicol Pharmacol 2010; 56(3): 290-9.
    • (2010) Regul Toxicol Pharmacol , vol.56 , Issue.3 , pp. 290-299
    • Baldrick, P.1
  • 30
    • 77958184731 scopus 로고    scopus 로고
    • Chitosan arrests bleeding in major hepatic injuries with clotting dysfunction: An in vivo experimental study in a model of hepatic injury in the presence of moderate systemic heparinisation
    • Millner R, Lockhart AS, Marr R: Chitosan arrests bleeding in major hepatic injuries with clotting dysfunction: an in vivo experimental study in a model of hepatic injury in the presence of moderate systemic heparinisation. Ann R Coll Surg Engl 2010; 92: 559-61.
    • (2010) Ann R Coll Surg Engl , vol.92 , pp. 559-561
    • Millner, R.1    Lockhart, A.S.2    Marr, R.3
  • 31
    • 0031014576 scopus 로고    scopus 로고
    • Use of chitosan as a biomaterial: Studies on its safety and hemostatic potential
    • Rao SB, Sharma CP: Use of chitosan as a biomaterial: studies on its safety and hemostatic potential. J Biomed Mater Res 1997; 34(1): 21-8.
    • (1997) J Biomed Mater Res , vol.34 , Issue.1 , pp. 21-28
    • Rao, S.B.1    Sharma, C.P.2
  • 33
    • 33645549194 scopus 로고    scopus 로고
    • A special report on the chitosan-based hemostatic dressing: Experience in current combat operations
    • Wedmore I, McManus JG, Pusateri AE, Holcomb JB: A special report on the chitosan-based hemostatic dressing: experience in current combat operations. J Trauma 2006; 60: 655-8.
    • (2006) J Trauma , vol.60 , pp. 655-658
    • Wedmore, I.1    McManus, J.G.2    Pusateri, A.E.3    Holcomb, J.B.4
  • 34
    • 79952901441 scopus 로고    scopus 로고
    • Celox (Chitosan) for haemostasis in massive traumatic bleeding: Experience in Afghanistan
    • Pozza M, Millner RW: Celox (chitosan) for haemostasis in massive traumatic bleeding: experience in Afghanistan. Eur J Emerg Med 2011; 18: 31-3.
    • (2011) Eur J Emerg Med , vol.18 , pp. 31-33
    • Pozza, M.1    Millner, R.W.2
  • 35
    • 84926322057 scopus 로고    scopus 로고
    • Field experience with a chitosan-based haemostatic dressing
    • Tan ECTH, Bleeker CP: Field experience with a chitosan-based haemostatic dressing. Med Corps Int Forum 2011; 3(4): 11-5.
    • (2011) Med Corps Int Forum , vol.3 , Issue.4 , pp. 11-15
    • Tan, E.1    Bleeker, C.P.2
  • 36
    • 67349139185 scopus 로고    scopus 로고
    • Efficacy of three topical hemostatic agents applied by medics in a lethal groin injury model
    • Sohn VY, Eckert MJ, Martin MJ, et al: Efficacy of three topical hemostatic agents applied by medics in a lethal groin injury model. J Surg Res 2009; 154: 258-61.
    • (2009) J Surg Res , vol.154 , pp. 258-261
    • Sohn, V.Y.1    Eckert, M.J.2    Martin, M.J.3
  • 37
    • 64749105166 scopus 로고    scopus 로고
    • A highly porous silica and chitosan-based hemostatic dressing is superior in controlling hemorrhage in a severe groin injury model in swine
    • Sambasivan CN, Cho SD, Zink KA, Differding JA, Schreiber MA: A highly porous silica and chitosan-based hemostatic dressing is superior in controlling hemorrhage in a severe groin injury model in swine. Am J Surg 2009; 197(5): 576-80.
    • (2009) Am J Surg , vol.197 , Issue.5 , pp. 576-580
    • Sambasivan, C.N.1    Cho, S.D.2    Zink, K.A.3    Differding, J.A.4    Schreiber, M.A.5
  • 39
    • 44449116313 scopus 로고    scopus 로고
    • An alternative hemostatic dressing: Comparison of CELOX, HemCon, and QuikClot
    • Kozen BG, Kircher SJ, Henao J, Godinez FS, Johnson AS: An alternative hemostatic dressing: comparison of CELOX, HemCon, and QuikClot. Acad Emerg Med 2008; 15(1): 74-81.
    • (2008) Acad Emerg Med , vol.15 , Issue.1 , pp. 74-81
    • Kozen, B.G.1    Kircher, S.J.2    Henao, J.3    Godinez, F.S.4    Johnson, A.S.5
  • 40
    • 77953307878 scopus 로고    scopus 로고
    • Comparative testing of new hemostatic agents in a swine model of extremity arterial and venous hemorrhage
    • Clay JG, Grayson JK, Zierold D: Comparative testing of new hemostatic agents in a swine model of extremity arterial and venous hemorrhage. Mil Med 2010; 175: 280-4.
    • (2010) Mil Med , vol.175 , pp. 280-284
    • Clay, J.G.1    Grayson, J.K.2    Zierold, D.3
  • 41
    • 79954622949 scopus 로고    scopus 로고
    • Comparison of Celox-A, Chitoflex, WoundStat, and combat gauze hemostatic agents versus standard gauze dressing in control of hemorrhage in a swine model of penetrating trauma
    • Littlejohn LF, Devlin JJ, Kircher SS, Lueken R, Melia MR, Johnson AS: Comparison of Celox-A, Chitoflex, WoundStat, and combat gauze hemostatic agents versus standard gauze dressing in control of hemorrhage in a swine model of penetrating trauma. Acad Emerg Med 2011; 18: 340–50
    • (2011) Acad Emerg Med , vol.18 , pp. 340-350
    • Littlejohn, L.F.1    Devlin, J.J.2    Kircher, S.S.3    Lueken, R.4    Melia, M.R.5    Johnson, A.S.6
  • 42
    • 79952402858 scopus 로고    scopus 로고
    • Hemostatic dressings reduce tourniquet time
    • Macintyre AD, Quick JA, Barnes SL: Hemostatic dressings reduce tourniquet time. Am Surg 2011; 77: 162–5
    • (2011) Am Surg , vol.77 , pp. 162-165
    • Macintyre, A.D.1    Quick, J.A.2    Barnes, S.L.3
  • 43
    • 84929155997 scopus 로고    scopus 로고
    • A Joint Trauma System Review of Pre-Hospital Trauma Care in Combined Joint Operating Area-Afghanistan (CJOA-A) Mac Dill AFB, FL, U.S. Central Command, January 30, accessed May 2, 2013
    • Kotwal RS, Butler FK, Edgar EP, Shackelford SA, Bennett DR, Bailey JA: Saving Lives on the Battlefield. A Joint Trauma System Review of Pre-Hospital Trauma Care in Combined Joint Operating Area-Afghanistan (CJOA-A) Mac Dill AFB, FL, U.S. Central Command, January 30, 2013. Available at http://www.jsomonline.org/PDFs/CENTCOM%20Prehospital%20Final%20Report%20130130.pdf; accessed May 2, 2013
    • (2013) Saving Lives on the Battlefield
    • Kotwal, R.S.1    Butler, F.K.2    Edgar, E.P.3    Shackelford, S.A.4    Bennett, D.R.5    Bailey, J.A.6
  • 44
    • 84864628538 scopus 로고    scopus 로고
    • A novel sponge-based wound stasis dressing to treat lethal noncompressible hemorrhage
    • Mueller GR, Pineda TJ, Xie HX, et al: A novel sponge-based wound stasis dressing to treat lethal noncompressible hemorrhage. J Trauma Acute Care Surg 2012; 73: S134–9.
    • (2012) J Trauma Acute Care Surg , vol.73 , pp. S134-S139
    • Mueller, G.R.1    Pineda, T.J.2    Xie, H.X.3
  • 45
    • 0032944682 scopus 로고    scopus 로고
    • Effect of dry fibrin sealant dressings versus gauze packing on blood loss in grade V liver injuries in resuscitated swine
    • Holcomb JB, Pusateri AE, Harris RA, et al: Effect of dry fibrin sealant dressings versus gauze packing on blood loss in grade V liver injuries in resuscitated swine. J Trauma 1999; 46(1): 49–57.
    • (1999) J Trauma , vol.46 , Issue.1 , pp. 49-57
    • Holcomb, J.B.1    Pusateri, A.E.2    Harris, R.A.3
  • 46
    • 0032793270 scopus 로고    scopus 로고
    • Dry fibrin sealant dressings reduce blood loss, resuscitation volume, and improve survival in hypothermic coagulopathic swine with grade V liver injuries
    • Holcomb JB, Pusateri AE, Harris RA, et al: Dry fibrin sealant dressings reduce blood loss, resuscitation volume, and improve survival in hypothermic coagulopathic swine with grade V liver injuries. J Trauma 1999; 47(2): 233–40.
    • (1999) J Trauma , vol.47 , Issue.2 , pp. 233-240
    • Holcomb, J.B.1    Pusateri, A.E.2    Harris, R.A.3
  • 47
    • 30044437888 scopus 로고    scopus 로고
    • Comparison of hemorrhage control agents applied to lethal extremity arterial hemorrhages in swine
    • Acheson EM, Kheirabadi BS, Deguzman R, Dick EJ Jr, Holcomb JB: Comparison of hemorrhage control agents applied to lethal extremity arterial hemorrhages in swine. J Trauma 2005; 59(4): 865–74.
    • (2005) J Trauma , vol.59 , Issue.4 , pp. 865-874
    • Acheson, E.M.1    Kheirabadi, B.S.2    Deguzman, R.3    Dick, E.J.4    Holcomb, J.B.5
  • 48
    • 0037803489 scopus 로고    scopus 로고
    • Comparative analysis of hemostatic agents in a swine model of lethal groin injury
    • Alam HB, Uy GB, Miller D, et al: Comparative analysis of hemostatic agents in a swine model of lethal groin injury. J Trauma 2003; 54: 1077–82.
    • (2003) J Trauma , vol.54 , pp. 1077-1082
    • Alam, H.B.1    Uy, G.B.2    Miller, D.3
  • 49
    • 42049102366 scopus 로고    scopus 로고
    • QuikClot use in trauma for hemorrhage control: Case series of 103 documented uses
    • Rhee P, Brown C, Martin M, et al: QuikClot use in trauma for hemorrhage control: case series of 103 documented uses. J Trauma 2008; 64(4): 1093–9.
    • (2008) J Trauma , vol.64 , Issue.4 , pp. 1093-1099
    • Rhee, P.1    Brown, C.2    Martin, M.3
  • 50
    • 70449090425 scopus 로고    scopus 로고
    • Models for hemostatic agent testing: Control versus fidelity
    • Devlin JJ, Kircher SJ, Littlejohn LF: Models for hemostatic agent testing: control versus fidelity. J Trauma 2009; 67(3): 677–8.
    • (2009) J Trauma , vol.67 , Issue.3 , pp. 677-678
    • Devlin, J.J.1    Kircher, S.J.2    Littlejohn, L.F.3
  • 52
    • 0031983293 scopus 로고    scopus 로고
    • Efficacy of a dry fibrin sealant dressing for hemorrhage control after ballistic injury
    • Holcomb J, MacPhee M, Hetz S, Harris R, Pusateri A, Hess J: Efficacy of a dry fibrin sealant dressing for hemorrhage control after ballistic injury. Arch Surg 1998; 133: 32–5
    • (1998) Arch Surg , vol.133 , pp. 32-35
    • Holcomb, J.1    Macphee, M.2    Hetz, S.3    Harris, R.4    Pusateri, A.5    Hess, J.6
  • 53
    • 84881435375 scopus 로고    scopus 로고
    • Comparison of novel hemostatic dressings with QuikClot Combat Gauze in a standardized swine model of uncontrolled hemorrhage
    • Rall JM, Cox JM, Songer AG, Cestero RF, Ross JD: Comparison of novel hemostatic dressings with QuikClot Combat Gauze in a standardized swine model of uncontrolled hemorrhage. J Trauma Acute Care Surg 2013; 75(2 Suppl 2): S150–6.
    • (2013) J Trauma Acute Care Surg , vol.75 , Issue.2 , pp. S150-S156
    • Rall, J.M.1    Cox, J.M.2    Songer, A.G.3    Cestero, R.F.4    Ross, J.D.5
  • 56
    • 67650289742 scopus 로고    scopus 로고
    • Increased mortality associated with the early coagulopathy of trauma in combat casualties
    • Niles SE, McLaughlin DF, Perkins JF, et al: Increased mortality associated with the early coagulopathy of trauma in combat casualties. J Trauma 2008; 64: 1459–65.
    • (2008) J Trauma , vol.64 , pp. 1459-1465
    • Niles, S.E.1    McLaughlin, D.F.2    Perkins, J.F.3
  • 57
    • 84871889741 scopus 로고    scopus 로고
    • The effects of QuikClot Combat Gauze on hemorrhage control in the presence of hemodilution
    • October–December
    • Johnson D, Agee S, Reed A, et al: The effects of QuikClot Combat Gauze on hemorrhage control in the presence of hemodilution. US Army Med Dep J 2012 October–December: 36–9.
    • (2012) US Army Med Dep J , pp. 36-39
    • Johnson, D.1    Agee, S.2    Reed, A.3
  • 58
    • 84866024908 scopus 로고    scopus 로고
    • The efficacy of Combat Gauze in extreme physiologic conditions
    • Causey MW, McVay DP, Miller S, Beekley A, Martin M: The efficacy of Combat Gauze in extreme physiologic conditions. J Surg Res 2012; 177(2): 301–5.
    • (2012) J Surg Res , vol.177 , Issue.2 , pp. 301-305
    • Causey, M.W.1    McVay, D.P.2    Miller, S.3    Beekley, A.4    Martin, M.5
  • 59
    • 84929184264 scopus 로고    scopus 로고
    • Advanced Technology Applications for Combat Casualty Care Conference 2011, accessed on May 2
    • Hoggarth A., Hardy C., Lyon A.: Testing a new gauze hemostat with reduced treatment time. Advanced Technology Applications for Combat Casualty Care Conference 2011, abstract Available at http://www.celoxmedical.com/docs/Celox%20Rapid%20reduced%20compression%20time%20poster.pdf; accessed on May 2, 2013.
    • (2013) Testing a New Gauze Hemostat with Reduced Treatment Time
    • Hoggarth, A.1    Hardy, C.2    Lyon, A.3
  • 61
    • 84876297695 scopus 로고    scopus 로고
    • Chitosan based hemostatic dressing is associated with decreased blood loss in a swine uncontrolled hemorrhage model
    • Kunio N, Riha GM, Watson KM, Differding JA, Schreiber MA, Watters JM: Chitosan based hemostatic dressing is associated with decreased blood loss in a swine uncontrolled hemorrhage model. Am J Surg 2013; 205(5): 505–10.
    • (2013) Am J Surg , vol.205 , Issue.5 , pp. 505-510
    • Kunio, N.1    Riha, G.M.2    Watson, K.M.3    Differding, J.A.4    Schreiber, M.A.5    Watters, J.M.6
  • 62
    • 58449100027 scopus 로고    scopus 로고
    • Case report of uncontrollable pelvic bleeding—managed by a previously unreported method (Quikclot)
    • Shanmugam V, Robinson MH: Case report of uncontrollable pelvic bleeding—managed by a previously unreported method (Quikclot). Colorectal Dis 2009; 11(2): 221–2
    • (2009) Colorectal Dis , vol.11 , Issue.2 , pp. 221-222
    • Shanmugam, V.1    Robinson, M.H.2
  • 63
    • 67249113485 scopus 로고    scopus 로고
    • Experience with chitosan dressings in a civilian EMS system
    • Brown MA, Daya MR, Worley JA: Experience with chitosan dressings in a civilian EMS system. J Emerg Med 2009; 37(1): 1–7
    • (2009) J Emerg Med , vol.37 , Issue.1 , pp. 1-7
    • Brown, M.A.1    Daya, M.R.2    Worley, J.A.3
  • 65
    • 58249132314 scopus 로고    scopus 로고
    • A new hemostatic agent: Initial life-saving experience with Celox (chitosan) in cardiothoracic surgery
    • Millner RWJ, Lockhart AS, Bird H, Alexiou C: A new hemostatic agent: initial life-saving experience with Celox (chitosan) in cardiothoracic surgery. Ann Thorac Surg 2009; 87: e13–4.
    • (2009) Ann Thorac Surg , vol.87 , pp. e13-e14
    • Millner, R.1    Lockhart, A.S.2    Bird, H.3    Alexiou, C.4
  • 66
    • 84863424795 scopus 로고    scopus 로고
    • Successful use of a military haemostatic agent in patients undergoing extracorporeal circulatory assistance and delayed sternal closure
    • Muzzi L, Tommasino G, Tucci E, Neri E: Successful use of a military haemostatic agent in patients undergoing extracorporeal circulatory assistance and delayed sternal closure. Interact Cardiovasc Thorac Surg 2012; 14: 695–8.
    • (2012) Interact Cardiovasc Thorac Surg , vol.14 , pp. 695-698
    • Muzzi, L.1    Tommasino, G.2    Tucci, E.3    Neri, E.4
  • 67
    • 84863692325 scopus 로고    scopus 로고
    • The mRDH bandage provides effective hemostasis in trauma and surgical hemorrhage
    • King DR, Schreiber M: The mRDH bandage provides effective hemostasis in trauma and surgical hemorrhage. J Trauma 2011; 71(2 Suppl 1): S167–70.
    • (2011) J Trauma , vol.71 , Issue.2 , pp. S167-S170
    • King, D.R.1    Schreiber, M.2
  • 68
    • 84255170064 scopus 로고    scopus 로고
    • Thirty consecutive uses of a hemostatic bandage at a US Army Combat Support Hospital and Forward Surgical Team in Operation Iraqi Freedom
    • King DR: Thirty consecutive uses of a hemostatic bandage at a US Army Combat Support Hospital and Forward Surgical Team in Operation Iraqi Freedom. J Trauma 2011; 71: 1775–8.
    • (2011) J Trauma , vol.71 , pp. 1775-1778
    • King, D.R.1
  • 69
    • 70449474477 scopus 로고    scopus 로고
    • Control of troublesome bleeding during repair of acute type A dissection with use of modified rapid deployment hemostat (MRDH)
    • Salerno TA, Gaughan C, Suarez M, Panos AL: Control of troublesome bleeding during repair of acute type A dissection with use of modified rapid deployment hemostat (MRDH). J Card Surg 2009; 24: 722–4.
    • (2009) J Card Surg , vol.24 , pp. 722-724
    • Salerno, T.A.1    Gaughan, C.2    Suarez, M.3    Panos, A.L.4
  • 70
    • 84857975521 scopus 로고    scopus 로고
    • A pre-hospital technique for controlling haemorrhage from traumatic perineal and high amputation injuries
    • Quayle JM, Thomas GOR: A pre-hospital technique for controlling haemorrhage from traumatic perineal and high amputation injuries. J R Army Med Corps 2011; 157(4): 419–20
    • (2011) J R Army Med Corps , vol.157 , Issue.4 , pp. 419-420
    • Quayle, J.M.1    Thomas, G.2
  • 71
    • 84888880492 scopus 로고    scopus 로고
    • The use of Celox gauze as an adjunct to pelvic Packing in otherwise uncontrollable pelvic haemorrhage secondary to penetrating trauma
    • Arul GS, Bowley DM, DiRusso S: The use of Celox gauze as an adjunct to pelvic Packing in otherwise uncontrollable pelvic haemorrhage secondary to penetrating trauma. J R Army Med Corps 2012; 158(4): 331–3.
    • (2012) J R Army Med Corps , vol.158 , Issue.4 , pp. 331-333
    • Arul, G.S.1    Bowley, D.M.2    Dirusso, S.3
  • 72
    • 78549253467 scopus 로고    scopus 로고
    • Preliminary study of the effects of smectite granules (WoundStat) on vascular repair and wound healing in a swine survival model
    • Gerlach T, Grayson JK, Pichakron KO, et al: Preliminary study of the effects of smectite granules (WoundStat) on vascular repair and wound healing in a swine survival model. J Trauma 2010; 69: 1203–9.
    • (2010) J Trauma , vol.69 , pp. 1203-1209
    • Gerlach, T.1    Grayson, J.K.2    Pichakron, K.O.3
  • 73
    • 84875275768 scopus 로고    scopus 로고
    • Long-term preclinical evaluation of the intracorporeal use of advanced local hemostatics in a damage-control swine model of grade IV liver injury
    • Inaba K, Branco BC, Rhee P, et al: Long-term preclinical evaluation of the intracorporeal use of advanced local hemostatics in a damage-control swine model of grade IV liver injury. J TraumaAcuteCare Surg 2013; 74(2): 538–45.
    • (2013) J Traumaacutecare Surg , vol.74 , Issue.2 , pp. 538-545
    • Inaba, K.1    Branco, B.C.2    Rhee, P.3
  • 74
    • 78650232269 scopus 로고    scopus 로고
    • The long term immunological response of swine after two exposures to a salmon thrombin and fibrinogen hemostatic bandage
    • Rothwell SW, Settle T, Wallace S, et al: The long term immunological response of swine after two exposures to a salmon thrombin and fibrinogen hemostatic bandage. Biologicals 2010; 38: 619–28.
    • (2010) Biologicals , vol.38 , pp. 619-628
    • Rothwell, S.W.1    Settle, T.2    Wallace, S.3
  • 75
    • 63449142315 scopus 로고    scopus 로고
    • In vitro models in biocompatibility assessment for biomedical-grade chitosan derivatives in wound management
    • Keong LC, Halim AS: In vitro models in biocompatibility assessment for biomedical-grade chitosan derivatives in wound management. Int J Mol Sci 2009; 10: 1300–13.
    • (2009) Int J Mol Sci , vol.10 , pp. 1300-1313
    • Keong, L.C.1    Halim, A.S.2
  • 76
    • 80053500122 scopus 로고    scopus 로고
    • Safety of chitosan bandages in shellfish allergic patients
    • Waibel KH, Haney B, Moore M, Whisman B, Gomez R: Safety of chitosan bandages in shellfish allergic patients. Mil Med 2011; 176: 1153–6.
    • (2011) Mil Med , vol.176 , pp. 1153-1156
    • Waibel, K.H.1    Haney, B.2    Moore, M.3    Whisman, B.4    Gomez, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.